PubMed Health⌕ Search

Biomedical subjects

F Keplinger

Publications and source records attributed to F Keplinger.

4 recordsLinked to original sources

A new floating sensor array to detect electric near fields of beating heart preparations.

A new flexible sensor for in vitro experiments was developed to measure the surface potential, Phi, and its gradient, E (electric near field), at given sites of the heart. During depolarisation, E describes a vector loop from which direction and magnitude of local conduction velocity theta can be computed. Four recording silver electrodes (14 microm x 14 microm) separated by 50 microm, conducting leads, and solderable pads were patterned on a 50 microm thick polyimide film. The conductive structures, except the electrodes, were isolated with polyimide, and electrodes were chlorided. Spacer pillars mounted on the tip fulfil two functions: they keep the electrodes 70 microm from the tissue allowing non-contact recording of Phi and prevent lateral slipping. The low mass (9.1 mg) and flexibility (6.33 N/m) of the sensor let it easily follow the movement of the beating heart without notable displacement. We examined the electrodes on criteria like rms-noise of Phi, signal-to-noise ratio of Phi and E, maximum peak-slope recording dPhi/dt, and deviation of local activation time (LAT) from a common signal and obtained values of 24-28 microV, 46 and 41 dB, 497-561 V/s and no differences, respectively. With appropriate data acquisition (sampling rate 100 kHz, 24-bit), we were able to record Phi and to monitor E and theta on-line from beat-to-beat even at heart rates of 600 beats/min. Moreover, this technique can discriminate between uncoupled cardiac activations (as occur in fibrotic tissue) separated by less than 1 mm and 1 ms.

Animals↗

The role of intra-abdominal pressure on splanchnic and pulmonary hemodynamic and metabolic changes during carbon dioxide pneumoperitoneum.

BACKGROUND AND METHODS: To find an intra-abdominal pressure (IAP) range for laparoscopic procedures that elicits only moderate splanchnic and pulmonary hemodynamic and metabolic changes, including hepatic and intestinal tissue pH and superficial hepatic blood flow, we installed an IAP of 7 and 14 mm Hg each for 30 minutes in 10 healthy pigs (30 +/- 4 kg). RESULTS: In parallel with the increase of IAP, the mean transmural pulmonary artery pressure increased (from 25 +/- 3 to 27 +/- 4 at 7 mm Hg IAP and 30 +/- 6 mm Hg at 14 mm Hg IAP, p < 0.05); the pulmonary artery-to-pulmonary capillary wedge pressure gradient also increased (from 17 +/- 2.7 to 21 +/- 3 mm Hg at 7 mm Hg IAP and 24 +/- 4.2 mm Hg at 14 mm Hg IAP, p < 0.01), and the arterial oxygenation decreased (p < 0.005). Relevant changes at an IAP of 14 mm Hg were observed in right atrial pressure during inspiration (from 7 +/- 2 to 12 +/- 3 mm Hg, p < 0. 0001) and in abdominal aortic flow (from 1.43 +/- 0.4 to 1.19 +/- 0. 3 L/min, p < 0.01). However, transmural right atrial pressure and cardiac output remained essentially unchanged. Portal and hepatic venous pressure increased in parallel with the IAP (portal: from 12 +/- 3 to 17 +/- 3 at 7 mm Hg IAP and 22 +/- 3 mm Hg at 14 mm Hg IAP, p < 0.01; hepatic venous: from 8 +/- 3 to 14 +/- 6 at 7 mm Hg IAP and 19 +/- 6 mm Hg at 14 mm Hg IAP, p < 0.005), but the transmural portal and hepatic venous pressures decreased (p < 0.01), indicating decreased venous filling. Portal flow was maintained at 7 mm Hg but decreased at 14 mm Hg from 474 +/- 199 to 395 +/- 175 mL/min (p < 0. 01), whereas hepatic arterial flow remained stable. Hepatic superficial blood flow decreased during insufflation and increased after desufflation. Tissue pH fell together with portal and hepatic venous pH (intestinal: from 7.323 +/- 0.05 to 7.217 +/- 0.04; hepatic: from 7.259 +/- 0.04 to 7.125 +/- 0.06, both p < 0.01) at 14 mm Hg. CONCLUSION: The hemodynamic and metabolic derangement in the pulmonary and splanchnic compartments are dependent on the extent of carbon dioxide pneumoperitoneum. The effect of low IAP (7 mm Hg) on splanchnic perfusion is minimal. However, higher IAPs (14 mm Hg) decrease portal and superficial hepatic blood flow and hepatic and intestinal tissue pH.

Abdomen↗