PubMed Health⌕ Search

Biomedical subjects

F Knebel

Publications and source records attributed to F Knebel.

5 recordsLinked to original sources

[Echocardiographic evaluation to select patients for cardiac resynchronization therapy].

Wide QRS complex and asynchronous myocardial contraction in heart failure are associated with poor prognosis. Resynchronization can be achieved by biventricular pacing (BVP), which leads to hemodynamic and clinical improvement and reverse remodeling, and may improve survival. However, there is a substantial subset of patients with wide QRS complexes in the electrocardiogram who does not improve despite BVP, and there are findings which suggest that resynchronization therapy may be also beneficial for heart failure patients with normal QRS duration. QRS width predicts the benefit of BVP only with limitation and only correlates weakly with echocardiographically determined myocardial asynchrony. Determination of asynchrony by tissue Doppler echocardiography seems to be the best predictor for improvement after BVP, although no consensus on the optimal method to assess asynchrony has yet been achieved. To date, most studies evaluating tissue Doppler echo in BVP were performed retrospectively and only one prospective study with patient selection for BVP according to echocardiography and electrocardiography criteria of asynchrony has been published. These new echocardiographic tools will help to prospectively select patients for BVP, help to guide implantation and to optimize device programming.

Arrhythmias, Cardiac↗

Echocardiographic AV-interval optimization in patients with reduced left ventricular function.

BACKGROUND: Ritter's method is a tool used to optimize AV delay in DDD pacemaker patients with normal left ventricular function only. The goal of our study was to evaluate Ritter's method in AV delay-interval optimization in patients with reduced left ventricular function. METHODS: Patients with implanted DDD pacemakers and AVB III degrees were assigned to one of two groups according to ejection fraction (EF): Group 1 (EF > 35%) and Group 2 (EF < 35%). AV delay optimization was performed by means of radionuclide ventriculography (RNV) and application of Ritter's method. RESULTS: For each of the patients examined, we succeeded in defining an optimal AV interval by means of both RNV and Ritter's method. The optimal AV delay determined by RNV correlated well with the delay found by Ritter's method, especially among those patients with reduced EF. The intra-class correlation coefficient was 0.8965 in Group 1 and 0.9228 in Group 2. The optimal AV interval in Group 1 was 190 +/- 28.5 ms, and 180 +/- 35 ms in Group 2. CONCLUSION: Ritter's method is also effective for optimization of AV intervals among patients with reduced left ventricular function (EF < 35%). The results obtained by RNV correlate well with those from Ritter's method. Individual programming of the AV interval is fundamentally essential in all cases.

Aged↗

Heart failure: state-of-the-art treatment and new therapeutic options.

Heart failure is one of the most common health problems in Western countries. Untreated, the prognosis is very poor and there is no curative therapeutic approach yet. The gold standard for final stage congestive heart failure (CHF) is still heart transplantation. In recent years the medical therapy of heart failure has improved significantly. But still, beta-blockers, ACE inhibitors and diuretics are not offered to every patient with chronic heart failure. Currently, new therapeutic approaches are being evaluated: immunoadsorption and biventricular pacing. This article summarizes the latest recommendations for medical therapy of heart failure and will explain the mechanisms and clinical results of these new therapeutic options.

Heart Failure↗

[Connector for double-lumen tubes in thoracic surgery interventions].

The junction between double-lumen endotracheal tube (DLT) and anaesthetic circuit is of crucial importance to modern anaesthesiological management in thoracic surgery. We present a connector which allows for all the essential procedures, such as clinical control of DLT position, use of fiberoptic bronchoscope (FOB) to control or correct DLT position, application of differential lung ventilation patterns or simple suction manoeuvres by easy handling, minimal interference, and avoidance of disconnection or clamping.

Bronchoscopes↗