PubMed Health⌕ Search

Biomedical subjects

F L Vicente

Publications and source records attributed to F L Vicente.

4 recordsLinked to original sources

Development and validation of limited-sampling strategies for predicting amoxicillin pharmacokinetic and pharmacodynamic parameters.

Amoxicillin plasma concentrations (n = 1,152) obtained from 48 healthy subjects in two bioequivalence studies were used to develop limited-sampling strategy (LSS) models for estimating the area under the concentration-time curve (AUC), the maximum concentration of drug in plasma (C(max)), and the time interval of concentration above MIC susceptibility breakpoints in plasma (T>MIC). Each subject received 500-mg amoxicillin, as reference and test capsules or suspensions, and plasma concentrations were measured by a validated microbiological assay. Linear regression analysis and a "jack-knife" procedure revealed that three-point LSS models accurately estimated (R(2), 0.92; precision, <5.8%) the AUC from 0 h to infinity (AUC(0-infinity)) of amoxicillin for the four formulations tested. Validation tests indicated that a three-point LSS model (1, 2, and 5 h) developed for the reference capsule formulation predicts the following accurately (R(2), 0.94 to 0.99): (i) the individual AUC(0-infinity) for the test capsule formulation in the same subjects, (ii) the individual AUC(0-infinity) for both reference and test suspensions in 24 other subjects, and (iii) the average AUC(0-infinity) following single oral doses (250 to 1,000 mg) of various amoxicillin formulations in 11 previously published studies. A linear regression equation was derived, using the same sampling time points of the LSS model for the AUC(0-infinity), but using different coefficients and intercept, for estimating C(max). Bioequivalence assessments based on LSS-derived AUC(0-infinity)'s and C(max)'s provided results similar to those obtained using the original values for these parameters. Finally, two-point LSS models (R(2) = 0.86 to 0.95) were developed for T>MICs of 0.25 or 2.0 microg/ml, which are representative of microorganisms susceptible and resistant to amoxicillin.

Adult↗

Limited-sampling strategy models for estimating the pharmacokinetic parameters of 4-methylaminoantipyrine, an active metabolite of dipyrone.

Bioanalytical data from a bioequivalence study were used to develop limited-sampling strategy (LSS) models for estimating the area under the plasma concentration versus time curve (AUC) and the peak plasma concentration (Cmax) of 4-methylaminoantipyrine (MAA), an active metabolite of dipyrone. Twelve healthy adult male volunteers received single 600 mg oral doses of dipyrone in two formulations at a 7-day interval in a randomized, crossover protocol. Plasma concentrations of MAA (N = 336), measured by HPLC, were used to develop LSS models. Linear regression analysis and a "jack-knife" validation procedure revealed that the AUC(0-infinity) and the Cmax of MAA can be accurately predicted (R2>0.95, bias <1.5%, precision between 3.1 and 8.3%) by LSS models based on two sampling times. Validation tests indicate that the most informative 2-point LSS models developed for one formulation provide good estimates (R2>0.85) of the AUC(0-infinity) or Cmax for the other formulation. LSS models based on three sampling points (1.5, 4 and 24 h), but using different coefficients for AUC(0-infinity) and Cmax, predicted the individual values of both parameters for the enrolled volunteers (R2>0.88, bias = -0.65 and -0.37%, precision = 4.3 and 7.4%) as well as for plasma concentration data sets generated by simulation (R2>0.88, bias = -1.9 and 8.5%, precision = 5.2 and 8.7%). Bioequivalence assessment of the dipyrone formulations based on the 90% confidence interval of log-transformed AUC(0-infinity) and Cmax provided similar results when either the best-estimated or the LSS-derived metrics were used.

Adult↗

Limited-sampling strategy models for estimating the area under the plasma concentration-time curve for amlodipine.

OBJECTIVE: Develop and validate limited-sampling strategy (LSS) models for estimating the area under the plasma concentration versus time curve (AUC) of amlodipine, using data from a bioequivalence study. METHODS: Sixteen healthy volunteers received single 5-mg oral doses of amlodipine, as reference or test formulation, at a 14-day interval, in a randomized, crossover protocol. Plasma concentrations of amlodipine (n = 288), measured by mass spectrometry, were used to develop LSS models. RESULTS: Linear regression analysis of the AUC0-72 and a "jack-knife" validation procedure revealed that LSS models based on two sampling times (12 h and 48 h) predict accurately (R2 = 0.99; bias < 0.01%; precision = 0.03%) the AUC0-72 of amlodipine for each formulation. Validation tests indicate that the 2-point LSS model developed for the reference formulation predicts accurately (R2 > 0.90): (a) the individual AUC0-72 for the test formulation in the same group of volunteers; (b) the individual AUC0-72 for the same reference formulation in another bioequivalence study in Brazilian volunteers; (c) the average AUC0-72 reported in seven additional international studies performed under protocols similar to the present investigation; (d) the individual AUC0-72 corresponding to concentration data points provided by a first-order compartmental pharmacokinetic model, when the relative values of either the absorption rate (Kabs) or the bioavailability (F) model parameters were set at 0.85 or 0.6, of their respective original values. CONCLUSIONS: The 2-point LSS models developed in the current study predict accurately the AUC of amlodipine under a variety of experimental conditions and, thus, may be valuable for exploring the relationships between the pharmacokinetics and pharmacodynamics of this calcium antagonist, at reduced costs of sample acquisition and analysis, and avoiding sampling at "unsociable" hours.

Administration, Oral↗

Limited-sampling strategy models for itraconazole and hydroxy-itraconazole based on data from a bioequivalence study.

The extensive interindividual variability in oral bioavailability of itraconazole prompted an assessment of the bioequivalence of two formulations marketed in Brazil, namely, Sporanox (reference) and Traconal (test). Eighteen healthy volunteers received single 200-mg oral doses of each formulation at 2-week intervals in a randomized, crossover protocol. The concentrations of itraconazole and hydroxy-itraconazole in plasma were measured by high-performance liquid chromatography, and the datum points (n = 396) were subsequently used to develop limited-sampling strategy models for estimation of the areas under the curve (AUCs) for both compounds. The 90% confidence intervals for individual percent ratios (test/reference formulations) of the maximum concentration of drug in serum, the AUC from 0 to 48 h and the AUC from time zero to infinity (AUC0-infinity) for itraconazole and hydoxy-itraconazole were below the range of 80 to 125%, suggesting that these formulations are not bioequivalent. Linear regression analysis of the AUC0-infinity against time and a "jackknife" validation procedure revealed that models based on three sampling times accurately predict (R2, >0.98; bias, <3%; precision, 3 to 7%) the AUC0-infinity for each of the four formulation-compound pairs tested. Increasing the number of sampling points to more than three adds little to the accuracy of the estimates of AUC0-infinity. The three-point models developed for the reference formulation were validated retrospectively and were found to predict within 2% the AUC0-infinity reported in previous studies performed under similar protocols. In conclusion, the data in this study indicate (i) that the tested formulations are not bioequivalent when single doses are compared and (ii) that limited-sampling strategy models based on three points predict accurately the AUC0-infinitys for itraconazole and hydroxy-itraconazole and could be a valuable tool in pharmacokinetic and bioequivalence studies of single oral doses of itraconazole.

Adult↗