A model of head-related transfer functions based on principal components analysis and minimum-phase reconstruction.

Free-field to eardrum transfer functions (HRTFs) were measured from both ears of 10 subjects with sound sources at 265 different positions. A principal components analysis of the resulting 5300 HRTF magnitude functions revealed that the HRTFs can be modeled as a linear combination of five basic spectral shapes (basis functions), and that this representation accounts for approximately 90% of the variance in the original HRTF magnitude functions. HRTF phase was modeled by assuming that HRTFs are minimum-phase functions and that interaural phase differences can be approximated by a simple time delay. Subjects' judgments of the apparent directions of headphone-presented sounds that had been synthesized from the modeled HRTFs were nearly identical to their judgments of sounds synthesized from measured HRTFs. With fewer than five basis functions used in the model, a less faithful reconstruction of the HRTF was produced, and the frequency of large localization errors increased dramatically.

Attention

The dominant role of low-frequency interaural time differences in sound localization.

Two experiments are described in which listeners judge the apparent directions of virtual sound sources-headphone-presented sounds that are processed in order to simulate free-field sounds. Previous results suggest that when the cues to sound direction are preserved by the simulation, the apparent directions of virtual sources are nearly the same as the apparent directions of real free-field sources. In the experiments reported here, the interaural phase relations in the processing algorithms are manipulated in order to produce stimuli in which the interaural time difference cues signal one direction and interaural intensity and pinna cues signal another direction. The apparent directions of these conflicting cue stimuli almost always follow the interaural time cue, as long as the wideband stimuli include low frequencies. With low frequencies removed from the stimuli, the dominance of interaural time difference disappears, and apparent direction is determined primarily by interaural intensity difference and pinna cues.

Adult

Headphone simulation of free-field listening. I: Stimulus synthesis.

This article describes techniques used to synthesize headphone-presented stimuli that simulate the ear-canal waveforms produced by free-field sources. The stimulus synthesis techniques involve measurement of each subject's free-field-to-eardrum transfer functions for sources at a large number of locations in free field, and measurement of headphone-to-eardrum transfer functions with the subject wearing headphones. Digital filters are then constructed from the transfer function measurements, and stimuli are passed through these digital filters. Transfer function data from ten subjects and 144 source positions are described in this article, along with estimates of the various sources of error in the measurements. The free-field-to-eardrum transfer function data are consistent with comparable data reported elsewhere in the literature. A comparison of ear-canal waveforms produced by free-field sources with ear-canal waveforms produced by headphone-presented simulations shows that the simulations duplicate free-field waveforms within a few dB of magnitude and a few degrees of phase at frequencies up to 14 kHz.

Acoustic Stimulation

Headphone simulation of free-field listening. II: Psychophysical validation.

Listeners reported the apparent spatial positions of wideband noise bursts that were presented either by loudspeakers in free field or by headphones. The headphone stimuli were digitally processed with the aim of duplicating, at a listener's eardrums, the waveforms that were produced by the free-field stimuli. The processing algorithms were based on each subject's free-field-to-eardrum transfer functions that had been measured at 144 free-field source locations. The headphone stimuli were localized by eight subjects in virtually the same positions as the corresponding free-field stimuli. However, with headphone stimuli, there were more front-back confusions, and source elevation seemed slightly less well defined. One subject's difficulty with elevation judgments, which was observed both with free-field and with headphone stimuli, was traced to distorted features of the free-field-to-eardrum transfer function.

Acoustic Stimulation

Detectability of a pulsed tone in the presence of a masker with time-varying interaural correlation.

Detectability of a filtered probe tone (250, 500, or 1000 Hz) was measured in the presence of a narrow-band Gaussian masker centered at the signal frequency. The signal was interaurally phase-reversed (Spi), and the masker's interaural correlation varied sinusoidally between +1.00 (NO) and -1.00 (Npi) at a varaible rate (fm = 0--4 Hz). The signal was presented at various points on the masker's modulation cycle. For 0-Hz modulation (fixed interaural correlation) signal threshold decreased monotonically as the masker's interaural correlation was changed from -1.00 to +1.00 (by a total of about 20, 16, and 8 dB, respectively, for 250-, 500-, and 1000-Hz signals). For fm greater than 0 the function relating signal threshold to the masker's interaural correlation at the moment of signal presentation became progressively flatter with increasing fm for all signal frequencies. For fm = 4 Hz the function was flat; there was no measurable effect of masker interaural correlation on signal detectability. Estimates of minimum binaural integration time based on these data ranged from 44--243 ms, supporting previous studies which have noted the binaural system's relative insensitivity to dynamic stimulation. Additionally, the estimated time constants were approximately twice as large at 250 Hz as at 500 Hz, indicating observers could follow binaural fluctuations better at 500 Hz. The time-constant estimates at 1000 Hz were not suggiciently reliable to permit comparisons with the lower-frequency data.

Acoustic Impedance Tests

Detectability of varying interaural temporal differences.

Detectability and salience of time-varying interaural temporal differences (IATD's) were measured in three experiments by determining observers' ability to follow the temporal fluctuations of a "moving stimulus"--a 3000-Hz low-pass computer-generated noise presented binaurally with a sinusoidally varying IATD. In the first two experiments the peak IATD (deltat the "extent of movement") was manipulated to determine, for different rates of interaural variation (fm), threshold discriminability of the "moving" stimulus from a reference (two-interval forced-choice paradigm). The nonmoving reference was either a dichotic noise stimulus (experiment 1) or a dichotic noise stimulus whose "image width" matched that of the excursions traced by the "moving stimulus" (experiment 2). Threshold deltat's in the two experiments were similar, increasing from 30 microns at fm = 0 Hz to 90 microns at fm = 20 Hz, indicating a "low-pass characteristic" for the binaural system. Thresholds decreased again for fm = 50 Hz, apparently because at these high rates of "movement" observers used other cues than the varying IATD's to perform the task. The third experiment measured the threshold of a binaural click in the presence of a "moving noise" masker as a function of fm and of the instantaneous IATD of the masker when the click was presented. As fm increased, click threshold gradually became independent of the masker's instantaneous IATD, again suggesting a "low-pass" characteristic for the binaural system; additionally, there was some evidence for a lag in the system's response for fm greater than 5 Hz. The data from the three experiments are discussed in terms of results from other studies which have investigated temporal aspects of the binaural system. The possible existence of movement detectors in the auditory system is discussed.