Characteristics of sensitometric curves of radiographic films.

A new type of radiographic film, EDR (extended dose range) film, has been recently become available for film dosimetry. It is particularly attractive for composite isodose verification of intensity modulated radiation therapy because of its low sensitivity relative to the more common Kodak XV film. For XV film, the relationship between optical density and dose, commonly known as the sensitometric curve, depends linearly on the dose at low densities. Unlike XV film, the sensitometric curve of EDR film irradiated by megavoltage x rays is not linearly dependent on the dose at low densities. In this work, to understand the mechanisms governing the shape of the sensitometric curves, EDR film was studied with kilovoltage x rays, 60Co gamma rays, megavoltage x rays, and electron beams. As a comparison, XV film was also studied with the same beams mentioned above. The model originally developed by Silberstein [J. Opt. Soc. Am. 35, 93-107, 1945)] is used to fit experimental data. It is found that the single hit model can be used to predict the sensitometric curve for XV films irradiated by all beams used in this work and for EDR films exposed to kilovoltage x rays. For EDR film irradiated by 60Co gamma rays, megavoltage x rays, and electron beams, the double hit model is used to fit the sensitometric curves. For doses less than 100 cGy, a systematic difference between measured densities and that predicted by the double hit model is observed. Possible causes of the observed differences are discussed. The results of this work provide a theoretical explanation of the sensitometric behavior of EDR film.

Dose-Response Relationship, Radiation↗

Observation of the decay K- --> pi(-)mu(+)mu(-) and measurements of the branching ratios for K+/- --> pi(+/-)mu(+)mu(-).

Using data collected with the HyperCP (E871) spectrometer during the 1997 fixed-target run at Fermilab, we report the first observation of the decay K--->pi(-)mu(+)mu(-) and new measurements of the branching ratios for K+/--->pi(+/-)mu(+)mu(-). By combining the branching ratios for the decays K+-->pi(+)mu(+)mu(-) and K--->pi(-)mu(+)mu(-), we measure Gamma(K+/--->pi(+/-)mu(+)mu(-))/Gamma(K+/--->all) = (9.8+/-1.0+/-0.5)x10(-8). The CP asymmetry between the rates of the two decay modes is [Gamma(K+-->pi(+)mu(+)mu(-))-Gamma(K--->pi(-)mu(+)mu(-))]/[Gamma(K+-->pi(+)mu(+)mu(-))+Gamma(K--->pi(-)mu(+)mu(-))] = -0.02+/-0.11+/-0.04.

Journal Article↗

Epidural analgesia with 0.15% ropivacaine plus sufentanil 0.5 microgram ml-1 versus 0.10% bupivacaine plus sufentanil 0.5 microgram ml-1: a double-blind comparison during labour.

BACKGROUND: Ropivacaine has been claimed to produce less motor block than bupivacaine during epidural analgesia. However, this advantage has not been clearly confirmed in obstetric studies using low analgesic concentrations in a ratio close to that suggested to be equianalgesic. METHODS: This double-blind, randomized, prospective study was performed in 140 parturients who requested epidural analgesia. After a lumbar epidural catheter had been placed, patients received either 0.10% bupivacaine plus sufentanil 0.5 microgram ml-1 or 0.15% ropivacaine plus sufentanil 0.5 microgram ml-1 followed by a continuous infusion. Additional boluses were used for inadequate levels of analgesia. Visual analogue pain scores, motor block, level of sensory block, supplementary boluses and main characteristics of labour were recorded. RESULTS: No differences were observed between the two groups for pain scores, total volume of anaesthetic solution used [59 (23) and 57 (24) ml in the bupivacaine and ropivacaine groups respectively], duration of labour, mode of delivery, side-effects or satisfaction score. The incidence of motor block was not statistically different between the groups (54 and 69% in the bupivacaine and ropivacaine groups respectively, P = 0.07). However, when motor block occurred, survival analysis showed that it occurred sooner in the course of labour with ropivacaine compared with bupivacaine (log rank test, P = 0.012). CONCLUSION: Combined with sufentanil 0.5 microgram ml-1, 0.10% bupivacaine and 0.15% ropivacaine produce effective and equivalent analgesia during labour, with similar incidences of motor block.

Adult↗

Evaluation of Kodak EDR2 film for dose verification of intensity modulated radiation therapy delivered by a static multileaf collimator.

A new type of radiographic film, Kodak EDR2 film, was evaluated for dose verification of intensity modulated radiation therapy (IMRT) delivered by a static multileaf collimator (SMLC). A sensitometric curve of EDR2 film irradiated by a 6 MV x-ray beam was compared with that of Kodak X-OMAT V (XV) film. The effects of field size, depth and dose rate on the sensitometric curve were also studied. It is found that EDR2 film is much less sensitive than XV film. In high-energy x-ray beams, the double hit process is the dominant mechanism that renders the grains on EDR2 films developable. As a result, in the dose range that is commonly used for film dosimetry for IMRT and conventional external beam therapy, the sensitometric curves of EDR2 films cannot be approximated as a linear function, OD = c * D. Within experimental uncertainty, the film sensitivity does not depend on the dose rate (50 vs 300 MU/min) or dose per pulse (from 1.0 x 10(-4) to 4.21 x 10(-4) Gy/pulse). Field sizes and depths (up to field size of 10 x 10 cm2 and depth = 10 cm) have little effect on the sensitometric curves. Percent depth doses (PDDs) for both 6 and 23 MV x rays were measured with both EDR2 and XV films and compared with ion chamber data. Film data are within 2.5% of the ion chamber results. Dose profiles measured with EDR2 film are consistent with those measured with an ion chamber. Examples of measured IMRT isodose distributions versus calculated isodoses are presented. We have used EDR2 films for verification of all IMRT patients treated by SMLC in our clinic. In most cases, with EDR2 film, actual clinical daily fraction doses can be used for verification of composite isodose distributions of SMLC-based IMRT.

Adult↗

Neuronal nitric oxide synthase: a substrate for SHP-1 involved in sst2 somatostatin receptor growth inhibitory signaling.

Somatostatin receptor sst2 is an inhibitory G protein-coupled receptor, which inhibits normal and tumor cell growth by a mechanism involving the tyrosine phosphatase SHP-1. We reported previously that SHP-1 associates transiently with and is activated by sst2 and is a critical component for sst2 growth inhibitory signaling. Here, we demonstrate that in Chinese hamster ovary cells expressing sst2, SHP-1 is associated at the basal level with the neuronal nitric oxide synthase (nNOS). Following sst2 activation by the somatostatin analog RC-160, SHP-1 rapidly recruits nNOS tyrosine dephosphorylates and activates it. The resulting NO activates guanylate cyclase and inhibits cell proliferation. Coexpression of a catalytically inactive SHP-1 mutant with sst2 blocks RC-160-induced nNOS dephosphorylation and activation, as well as guanylate cyclase activation. In mouse pancreatic acini, RC-160 treatment reduces nNOS tyrosine phosphorylation accompanied by an increase of its activity. By opposition, in acini from viable motheaten (mev/mev) mice, which express a markedly inactive SHP-1, RC-160 has no effect on nNOS activity. Finally, expression of a dominant-negative form of nNOS prevents both RC-160-induced p27 up-regulation and cell proliferation inhibition. We therefore identified nNOS as a novel SHP-1 substrate critical for sst2-induced cell-growth arrest.

Animals↗

Multinodular polymyositis in a patient with human immunodeficiency and hepatitis C virus coinfection.

We report a patient who developed multiple inflammatory muscle masses and generalized polymyositis in the setting of combined human immunodeficiency virus (HIV) and hepatitis C virus (HCV) infection. Magnetic resonance imaging (MRI) of muscles showed patchy edema which was particularly intense within the nodular masses. Polymerase chain reaction (PCR) showed no evidence of either virus within muscle. This report reviews earlier literature on muscle nodules associated with myositis and discusses the differential diagnosis of muscle masses in HIV infection.

Adult↗

Somatostatin inhibits stem cell factor messenger RNA expression by Sertoli cells and stem cell factor-induced DNA synthesis in isolated seminiferous tubules.

Immature porcine Sertoli cells have been reported to be targets for the regulatory peptide somatostatin (SRIF), which inhibits the basal and FSH-induced proliferation of Sertoli cells through a decrease of cAMP production. In the present study, we show that SRIF inhibits both basal and FSH-stimulated expression of the stem cell factor (SCF), a Sertoli cell-specific gene. The SRIF-mediated inhibition of forskolin-triggered, but not of 8-bromoadenosine-cAMP-triggered, SCF mRNA expression demonstrates the involvement of adenylyl cyclase in underlying peptide actions. Moreover, these effects require functional coupling of specific plasma membrane receptors to adenylyl cyclase via inhibitory G proteins, because pertussis toxin prevents SRIF-mediated inhibition of SCF mRNA expression. Reverse transcription-polymerase chain reaction (RT-PCR) and Western blot assays suggest the involvement of sst2 receptors in SRIF actions on Sertoli cells. The biological relevance of these data is supported by an SRIF-mediated decrease in SCF-induced incorporation of [(3)H]thymidine in isolated seminiferous tubules. In situ hybridization and confocal microscopy show that, in seminiferous tubules only, spermatogonia display both c-kit and sst2 receptors. Taken together, these results suggest that SCF-stimulated DNA synthesis can be inhibited by SRIF in spermatogonia, but not in Sertoli and peritubular cells. Combined RT-PCR and immunohistochemical approaches point toward spermatogonia and Leydig cells as the source of testicular SRIF. These data argue in favor of paracrine/autocrine SRIF actions in testis.

8-Bromo Cyclic Adenosine Monophosphate↗

Dependence of virtual wedge factor on dose calibration and monitor units.

One of the important features of the Siemens Virtual Wedge (VW) is that the VW factor (VWF) is approximately equal to unity for all beams with a total deviation for a given wedge no greater than 0.05, as specified by Siemens. In this note we report the observed dependence of VWF on dose calibration (cGy/MU), monitor units (MU), and beam tuning for a Primus, a linear accelerator with two dose-rate ranges available for VW operation. The VWF is defined as the ratio of doses measured on the beam central axis for the wedge field to the open field; the open field dose is always measured with the nominal high dose-rate beam. When VW operates in the high dose-rate range, the VWF is independent of calibration (cGy/MU). When VW works in the low dose-rate range, the VWF varies linearly with the calibration of the low dose-rate mode. For a linear accelerator that has only one dose-rate range for VW, there is no observable dependence of VWF on the calibration. We also studied the monitor unit dependence of VWF. A discontinuity in VWF was observed at the switching point between the high and low dose-rate ranges. Working with Siemens, we have investigated causes of this discontinuity. As a result of this investigation, the discontinuity in VWF as a function monitor unit is practically removed.

Biophysical Phenomena↗

Sulfinyl-directed diastereoselective

Introduction of a homochiral p-tolylsulfinyl group at an appropriate position in the alkene accelerates the thermal [5C + 2C] intramolecular cycloaddition to beta-silyloxy-gamma-pyrones and, most importantly, leads to excellent levels of diastereodifferentiation. The resulting adducts can be easily desulfinylated to give optically active 8-oxabicyclic[3.2.1]octane intermediates which by virtue of their rich functionalization might be susceptible to elaboration into enantiomerically pure natural products containing seven-membered carbocycles and tetrahydrofurans.

Journal Article↗

Effect of inhaled nitric oxide in combination with almitrine on ventilation-perfusion distributions in experimental lung injury.

OBJECTIVE: To investigate a possible additive effect of combined nitric oxide (NO) and almitrine bismesylate (ALM) on pulmonary ventilation-perfusion (V(A)/Q) ratio. DESIGN: Prospective, controlled animal study. SETTING: Animal research facility of a university hospital. INTERVENTIONS: Three conditions were studied in ten female pigs with experimental acute lung injury (ALI) induced by repeated lung lavage: 1) 10 ppm NO, 2) 10 ppm NO with 1 microg/kg per min ALM, 3) 1 microg/ kg per min ALM. For each condition, gas exchange, hemodynamics and V(A)/Q distributions were analyzed using the multiple inert gas elimination technique (MIGET). MEASUREMENT AND RESULTS: With NO + ALM, arterial oxygen partial pressure (PaO2) increased from 63 +/- 18 mmHg to 202 +/- 97 mmHg while intrapulmonary shunt decreased from 50 +/- 15 % to 26 +/- 12% and blood flow to regions with a normal V(A)/Q ratio increased from 49 +/- 16 % to 72 +/- 15 %. These changes were significant when compared to untreated ALI (p < 0.05) and NO or ALM alone (p < 0.05), although improvements due to NO or ALM also reached statistical significance compared to ALI values (p < 0.05). CONCLUSIONS: We conclude that NO + ALM results in an additive improvement of pulmonary gas exchange in an experimental model of ALI by diverting additional blood flow from non-ventilated lung regions towards those with normal V(A)/Q relationships.

Administration, Inhalation↗

L-Carnitine effects on chemical composition of plasma lipoproteins of rabbits fed with normal and high cholesterol diets.

L-Carnitine plays an important role in the mitochondrial uptake of long-chain fatty acids in mammals. It has recently been shown that this compound has a marked hypo-cholesterolemic effect when used in conjunction with lipid-rich diets. The aim of this study was to investigate the effects of L-carnitine on the fatty acid composition of plasma lipoproteins in rabbits fed with different diets. Four different groups were investigated: group I (standard diet), group II (standard diet supplemented with L-carnitine at 80 mg/kg), group III (standard diet supplemented with 0.5% cholesterol), and group IV (standard diet supplemented with 0.5% cholesterol plus L-carnitine at 80 mg/kg). The feeding period was 126 d. Total plasma cholesterol was indistinguishable in groups I and II, but increased nearly 40-fold in group III. This increment was reduced by 50% in group IV. Correspondingly, total cholesterol content in lipoprotein fractions [very low density lipoprotein (VLDL), low density lipoprotein (LDL), high density lipoprotein (HDL) separated by agarose gel chromatography was the same for groups I and II, while for animals fed a cholesterol-rich diet (III) total cholesterol in VLDL + LDL increased nearly 100-fold when compared with groups I and II but, again, the increment was reduced by 50% in group IV. In contrast, total cholesterol in HDL increased only fivefold for both groups III and IV when compared with groups I and II, indicating no effects of L-carnitine on this parameter. The reduction of total cholesterol in VLDL + LDL particles in animals fed a cholesterol-rich diet plus L-carnitine was associated with a marked decrease in the ratio of cholesteryl ester to free cholesterol and a dramatic increase in their phospholipid content; opposite effects were observed for HDL. L-Carnitine induced a marked decrease in the saturated to unsaturated C16 + C18 fatty acid ratio in cholesteryl esters associated with VLDL and LDL from animals fed with both normal and cholesterol-rich diets. The opposite effect (a large increase in the saturated to unsaturated fatty acid ratio) was observed for both cholesteryl esters and phospholipids associated with HDL in animals fed with both diets. The results suggested that the hypocholesterolemic effects of L-carnitine could be associated with increased systemic breakdown of cholesteryl esters, a probable increase in reverse cholesterol transport, and the stabilization of a phospholipid-based structure of VLDL + LDL particles.

Animals↗

Transplantation with selected autologous peripheral blood CD34+Thy1+ hematopoietic stem cells (HSCs) in multiple myeloma: impact of HSC dose on engraftment, safety, and immune reconstitution.

OBJECTIVE: The aims of our study performed in myeloma were to evaluate the performance and the safety of Systemix's high-speed clinical cell sorter, to assess the safety and efficacy of deescalating cell dose cohorts of CD34+Thyl+ hematopoietic stem cells (HSCs) as autologous grafts by determining engraftment, and to assess the residual tumor cell contamination using polymerase chain reaction (PCR) amplification assays of patient-specific complementarity determining region III (CDR III) analysis for residual myeloma cells. MATERIALS AND METHODS: The clinical trial was performed in 31 multiple myeloma patients, using purified human CD34+Thyl+ HSCs mobilized from peripheral blood with cyclosphosphamide and granulocyte-macrophage colony-stimulating factor to support a single transplant after high-dose melphalan 140 mg/m2 alone (cohort 1) and with total body irradiation (TBI) (cohorts 2-5) after an HSC transplant cell dose de-escalation/escalation design. RESULTS: Twenty-three patients were transplanted. Engraftment data in the melphalan + TBI cohorts confirmed that HSC doses above the threshold dose of 0.8 x 10(6) CD34+Thy1+ HSCs/ kg provided prompt engraftment (absolute neutrophil count >0.5 x 10(9)/L day 10; platelet count >50 x 10(9)/L day 13). A higher rate of infections was observed in the early and late follow-up phases than usually reported after CD34+ selected or unselected autologous transplantation, which did not correlate with the CD34+Thy1+ HSC dose infused. Successful PCR for CDR III could only be performed in five patients on initial apheresis product and final CD34+Thy1+ HSC product and showed a median tumor log reduction >3.12. CONCLUSIONS: CD34+Thy1+ HSCs are markedly depleted or free of detectable tumor cells in multiple myeloma and are capable of producing fast and durable hematopoietic reconstitution at cell doses >0.8 x 10(6) CD34+Thy1+ HSCs/kg. The delayed immune reconstitution observed is not different from that described in unselected autologous bone marrow and peripheral blood mononucleated cells transplants in multiple myeloma and may be corrected by addition of T cells either to the graft or to the patient in the posttransplant phase.

Adult↗

Reverse transcriptase-polymerase chain reaction validation of 25 "orphan" genes from Escherichia coli K-12 MG1655.

Despite the accumulation of sequence information sampling from a broad spectrum of phyla, newly sequenced genomes continue to reveal a high proportion (50%-30%) of "uncharacterized" genes, including a significant number of strictly "orphan" genes, i.e., putative open reading frames (ORFs) without any resemblance to previously determined protein-coding sequences. Most genes found in databases have only been predicted by computer methods and have never been experimentally validated. Although theoretical evolutionary arguments support the reality of genes when homologs are found in a variety of distant species, this is not the case for orphan genes. Here, we report the direct reverse transcriptase-polymerase chain reaction assay of 25 strictly orphan ORFs of Escherichia coli. Two growth conditions, exponential and stationary phases, were tested. Transcripts were identified for a total of 19 orphan genes, with 2 genes found to be expressed in only one of the two growth conditions. Our results suggest that a vast majority of E. coli ORFs presently annotated as "hypothetical" correspond to bona fide genes. By extension, this implies that randomly occurring "junk" ORFs have been actively counter selected during the evolution of the dense E. coli genome.

Escherichia coli↗

Comparison of dosimetric characteristics of Siemens virtual and physical wedges.

Dosimetric properties of Virtual Wedge (VW) and physical wedge (PW) in 6 and 23 MV photon beams from a Siemens Primus linear accelerator, including wedge factors, depth doses, dose profiles, peripheral doses and surface doses, are compared. While there is a great difference in absolute values of wedge factors, VW factors (VWFs) and PW factors (PWFs) have a similar trend as a function of field size. PWFs have a stronger depth dependence than VWF due to beam hardening in PW fields. VW dose profiles in the wedge direction, in general, match very well with PW, except in the toe area of large wedge angles with large field sizes. Dose profiles in the nonwedge direction show a significant reduction in PW fields due to off-axis beam softening and oblique filtration. PW fields have significantly higher peripheral doses than open and VW fields. VW fields have similar surface doses as the open fields while PW fields have lower surface doses. Surface doses for both VW and PW increase with field size and slightly with wedge angle. For VW fields with wedge angles 45 degrees and less, the initial gap up to 3 cm is dosimetrically acceptable when compared to dose profiles of PW. VW fields in general use less monitor units than PW fields.

Humans↗

Implementation and verification of virtual wedge in a three-dimensional radiotherapy planning system.

Virtual Wedge (VW) is a Siemens treatment modality which generates wedge-shaped dose distributions by moving a collimator jaw from closed to open at a constant speed while varying the dose rate in every 2 mm jaw position. In this work, the implementation and verification of VW in a radiotherapy treatment planning (RTP) system is presented. The VW implementation models the dose delivered by VW using the Siemens monitor units (MU) analytic formalism which determines the number of MU required to generate a wedge-fluence profile at points across the VW beam. For any set of treatment parameters, the VW algorithm generates an "intensity map" that is used to model the modification of fluence emanating from the collimator. The intensity map is calculated as the ratio of MU delivered on an axis point, divided by the monitor units delivered on the central-axis MU(0). The dose calculation is then performed using either the Clarkson or Convolution/ Superposition algorithms. The VW implementation also models the operational constraints for the delivery of VW due to dose rate and jaw speed limits. Dose verifications with measured profiles were performed using both the Clarkson and Convolution/Superposition algorithms for three photon beams; Siemens Primus 6 and 23 MV, and Mevatron MD 15 MV. Agreement within 2% or 2 mm was found between calculated and measured doses, over a large set of test cases, for 15, 30, 45, and 60 degree symmetric and asymmetric VW fields, using the manufacturer's supplied mu and c values for each beam.