PubMed HealthSearch

Biomedical subjects

F M Montevecchi

Publications and source records attributed to F M Montevecchi.

14 recordsLinked to original sources

Poroelastic finite element analysis of a bone specimen under cyclic loading.

It had been suggested that the fluid embodied in bone lacunar-canalicular porosity may play an important role in bone remodelling [Weinbaum et al., 1994. Journal of Biomechanics 27, 339-360]. In this paper a finite element model of a poroelastic prismatic solid of rectangular cross-section is considered to simulate bone behaviour, precisely as in the previous work by Zhang and Cowin [Zhang and Cowin, 1994. Journal of Mechanical Physics of Solids 42, 1575-1599]. This solid is subject to combined cyclic axial and bending loads at its end. The objectives of the study are: (1) to verify the accuracy of the simplifying hypotheses underlying the analytical solutions established by the above authors; (2) to provide further insight into the behaviour of that solid; (3) to test the advantages in generality and versatility and the computing costs of general-purpose finite element codes in poroelastic analysis. The study is parametric with respect to the fluid leakage coefficient, to the ratio of the bending moment and axial load, and to the ratio of the characteristic relaxation time of the pore pressure over the excitation period. Results show that, for all the cases considered, the pore pressure distribution along the section height of the poroelastic beam exhibits a very good matching with previous analytical results. Stresses transversal with respect to the beam axis (assumed as constant or zero in previous analytical solutions) are evaluated. The analysis pointed out that: (1) the effects due to end-loads with zero resultants practically extinguish within a distance from the beam end almost equal to a typical length of the cross-section; (2) cross-sections remain plane above that distance; (3) the transversal total stresses are three orders of magnitude lower than axial stress.

Adaptation, Physiological

Intraventricular pressure drop and aortic blood acceleration as indices of cardiac inotropy: a comparison with the first derivative of aortic pressure based on computer fluid dynamics.

This paper presents a computational approach to ventricular fluid mechanics to evaluate three inotropic indices of early ejection: the intraventricular pressure drop (deltap). the first derivative of aortic flow rate (df/dt) and the first derivative of aortic pressure dp/dt. dp/dt is one of the most frequently used indices for assessing myocardial inotropy. Deltap and df/dt are characteristic of inertia driven flows and reflect the impulsive nature of the flow inside the ventricle during the ejection phase. The study is based on an axisymmetric fluid dynamics model of the left ventricle, developed according to the finite element approach. The fluid cavity is bounded by a shell containing two sets of counter-rotating contractile fibres. Two simulation sets were performed: the former to investigate the sensitivity of deltap and df/dt peaks (deltap(max) and df/dt(max)) with respect to changes in the inotropic state of the fibre. The latter allows the evaluation of the dependency of deltap(max) and df/dt(max) on afterload by means of two supravalvular stenoses of 50% and 70%. The model simulates the inertial features of ventricle behaviour. The calculated values of the indices investigated are in close agreement with those reported in the literature. The sensitivities of deltap(max) df/dt(max) and dp/dt(max) are calculated for the two simulation sets. Data are normalised with respect to the maximum values reached in the simulation set. The comparison indicates that deltap(max) has a greater sensitivity (3.4 vs. 3.1 ) and a more linear pattern than dp/dt(max) for changes in the inotropic state of the fibre. df/dt(max), shows a sensitivity close to dp/dt(max). Results confirm that the afterload does not affect dp/dt(max), in accordance with experimental observations, while deltap(max) and, to a major degree, df/dt(max) decrease when the afterload is increased.

Acceleration

Factors affecting the respiratory ratio during cardiopulmonary by-pass.

Despite the wide use of hypothermic cardiopulmonary bypass (CPB) during open heart surgery there is little information about the patient metabolism. In particular no complete studies addressed the assessment of the respiratory ratio (RR) during CPB at different core temperatures. Therefore a clinical study was performed in order to evaluate the oxygen consumption (VO2) and carbon dioxide production (VCO2) in adult patients with valvular or coronary heart disease undergoing CPB. Twenty-five patients (16 male, 9 female) aged between 26 and 76 (54.2+/-12.4 mean +/- SD) were the subjects of this study. Measurements (102) were taken at various perfusion flow rates (from 1.6 to 2.9 L/min(-1) x m(-2)) and temperatures (from 24 to 37 degrees C). Arterial and mixed venous gas analyses were performed and O2 and CO2 concentrations were calculated, including the carbamate contribute. We calculated VO2, VCO2 and then RR from artero-venous differences in O2 and CO2 contents. Both VO2 and VCO2 showed a positive linear correlation with temperature (r = 0.82 and r = 0.59 respectively) and with blood flow rate (r = 0.61 and r = 0.29 respectively). The mean RR was 0.78+/-0.28 and more than 84% of RR values fell in the range 0.5-1.2. No significant correlation between RR and temperature and blood flow rate was observed. VCO2 and RR showed a positive linear correlation with the gas to blood flow rate ratio (r = 0.37 and r = 0.49 respectively).

Adult

Virtual extracorporeal circulation process.

Virtual instruments for an extracorporeal circulation (ECC) process were developed to simulate the reactions of a patient to different artificial perfusion conditions. The computer simulation of the patient takes into account the hydraulic, volume, thermal and biochemical phenomena and their interaction with the devices involved in ECC (cannulae dimensions, oxygenator and filter types, pulsatile or continuous pump and thermal exchangers). On the basis of the patient's initialisation data (height, weight, Ht) and perfusion variables (pump flow rate, water temperature, gas flow rate and composition) imposed by the operator, the virtual ECC monitors simulated arterial and venous pressure tracings in real time, along with arterial and venous flow rate tracings, urine production tracing and temperature levels. Oxyhemoglobin arterial and venous blood saturation together with other related variables (pO2, pCO2, pH, HCO3 are also monitored. A drug model which allows the simulation of the effect of vasodilator and diuretic drugs is also implemented. Alarms are provided in order to check which variables (pressure, saturation, pH, urine flow) are out of the expected ranges during the ECC simulation. Consequently the possibility of modifying the control parameters of the virtual devices of the ECC in run-time mode offers an interaction mode between the operator and the virtual environment.

Blood Gas Analysis

A numerical fluid mechanical study of repaired congenital heart defects. Application to the total cavopulmonary connection.

A computational fluid dynamics study based on the application of the finite element method has been performed to investigate the local hemodynamics of the total cavopulmonary connection. This operation is used to treat congenital malformations of the right heart and consists of a by-pass of the right ventricle. In this paper the adopted methodology is presented, together with some of the preliminary results. A three-dimensional parametric model of the connection and a lumped-parameter mechanical model of the pulmonary circulation have been developed. The three-dimensional model has been used to simulate the local fluid dynamics for different designs of the connection, allowing a quantitative evaluation of the dissipated energy in each of the examined configurations. The pulmonary afterload of the three-dimensional model has been reproduced by coupling it with the pulmonary mechanical model. The results show that, from a comparative point of view, the energetic losses can be greatly reduced if a proper hydraulic design of the connection is adopted, which also allows control of the blood flow distribution into the lungs.

Algorithms

Computational evaluation of intraventricular pressure gradients based on a fluid-structure approach.

The dynamics of intraventricular blood flow, i.e. its rapid evolution, implies the rise of intraventricular pressure gradients (IPGs) characteristic of the inertia-driven events as experimentally observed by Pasipoularides (1987, 1990) and by Falsetti et al. (1986). The IPG time course is determined by the wall contraction which, in turn, depends on the load applied, namely the intraventricular pressure which is the sum of the aortic pressure (i.e., the systemic net response) and the IPG. Hence the IPGs account, at least in part, for the wall movement. These considerations suggest the necessity of a comprehensive analysis of the ventricular mechanics involving both ventricular wall mechanics and intraventricular fluid dynamics as each domain determines the boundary conditions of the other. This paper presents a computational approach to ventricular ejection mechanics based on a fluid-structure interaction calculation for the evaluation of the IPG time course. An axisymmetric model of the left ventricle is utilized. The intraventricular fluid is assumed to be Newtonian. The ventricle wall is thin and is composed of two sets of counter-rotating fibres which behave according to the modified version of Wong's sarcomere model proposed by Montevecchi and Pietrabissa and Pietrabissa et al. (1987, 1991). The full Navier-Stokes equations describing the fluid domain are solved using Galerkin's weighted residual approach in conjunction with finite element approximation (FIDAP). The wall displacement is solved using the multiplane quasi-Newton method proposed by Buzzi Ferraris and Tronconi (1985). The interaction procedure is performed by means of an external macro which compares the flow fields and the wall displacement and appropriately modifies the boundary conditions to reach the simultaneous and congruous convergence of the two problems. The results refer to a simulation of the ventricular ejection with a heart rate of 72 bpm. In this phase the ventricle ejects 61 cm3 (ejection fraction equal to 54 percent) and the ventricular pressure varies from 78 mmHg to 140 mmHg. The IPG show an oscillating behaviour with two major peaks at the beginning (11.09 mmHg) and at the end (4.32 mmHg) of the ejection phase, when the flow rate hardly changes, according to the experimental data. Furthermore the wall displacement, the wall stress and strain, the pressure and velocity fields are calculated and reported.

Blood Flow Velocity

Fluid-structure interaction problems in bio-fluid mechanics: a numerical study of the motion of an isolated particle freely suspended in channel flow.

In this paper a problem belonging to the moving boundary class is tackled with a 2-D application of computational fluid dynamics techniques. The motion of an isolated rigid particle freely suspended in an incompressible Newtonian fluid in a narrow channel is studied numerically at a low Reynolds number, yet different from zero. The actual problem consists of two coupled problems: the motion of the viscous fluid and that of the rigid particle suspended and convected with the fluid. The full Navier-Stokes equations (i.e. both transient and convective terms are included) are solved in the fluid domain by means of the finite element method, while the motion of the particle is determined on the basis of a rigid act of motion. Results from simulations corresponding to differential initial positions of the particle are shown in this paper: they allow one to study the rotational motions of the particle as well as its displacements. The goal of the paper is to analyse the lateral displacement behaviour of the particle, already observed in experimental studies in microcirculation. In particular, lateral migrations are supposed to be due to inertial forces acting in the fluid around the moving particle combined with the proximity of the resting wall (wall effect). Preliminary results are in fairly good agreement with those available in the literature.

Algorithms

Preliminary design and optimization of an ECC blood pump by means of a parametric approach.

This study concerns the development of an analytical parametric model of a centrifugal disk pump. The advantage of this kind of approach is to have an adaptable tool as a first step for the design of a pump device. The method allows the evaluation of the velocity profiles and the shear stresses within the impeller disks in the flow domain along with the performance of the device in terms of torque, mechanical power, power loss, head-flow performance, pump efficiency, and hemolytic index. Some simplifying hypotheses are assumed: steady state condition, laminar flow, Newtonian and incompressible fluid. The radial velocity profiles are assumed to be uniform and the flow cross-sectional area is assumed to be constant along the radius. The influence of the housing and secondary flows caused by recirculation are neglected. To test the approach reliability, the model was used to simulate a pump with the following characteristics: an external and internal radius of 50 mm and 5 mm, respectively, and a channel height of 2.5-0.25 mm (h) from inlet to outlet section. The angular velocity omega was varied in the range 500-3,000 rpm. The flow rate has been varied from 1 to 5 L/min. The results show that when the flow rate is increased, head performances obtained using this pump model vary from 411 to 100 mm Hg, and its efficiency varies from 48 to 15%. A parallel simulation has been carried out by means of a Finite Element Method model with an angular velocity equal to 2,000 rpm.(ABSTRACT TRUNCATED AT 250 WORDS)

Blood Flow Velocity

Mechanical characterization of a model of a multicomponent cardiac fibre.

We have developed a model of a cardiac fibre composed of several contractile units in series and activated in succession; each unit behaves according to Wong's model. The main difference between the multicomponent model and the classic monocomponent model is that it is possible to take into account both the dynamic phenomena due to the propagation of the activation signal along the fibre and the contractility of each unit from which the fibre is constructed. Isometric and isotonic contractions have been simulated under different conditions in terms of preload, afterload, frequency and number of inhibited units. The analysis of the results allows us to assert that the multicomponent fibre behaviour is in good agreement with experimental results from the literature. We believe that the multicomponent cardiac fibre should be regarded as a powerful tool linking the sarcomere contraction with that of the whole ventricle.

Biomechanical Phenomena

Clinical experience with a new pulsatile pump for infant and pediatric cardiopulmonary bypass.

A pulsatile pump of new concept has been developed for infant and pediatric cardiopulmonary bypass (cpb) (Parenzan-Fumero pump). A segment of elastic tubing is compressed by a pneumatically driven pushing plate under control of a microprocessor. Flow parameters such as pulse rate and stroke volume can be set. The pump can be synchronized with the patient's ECG for counterpulsation heart assist. A total of 87 open-heart procedures were performed using randomly either a conventional roller pump or the Parenzan-Fumero pump (respectively 39 and 48 patients). A previously published cpb protocol and anesthetic regimen were adopted in all cases. The results show increased cooling and rewarming rate (p less than 0.05) and urinary output, decreased vascular resistance, intensive care unit time and need for blood transfusion in the pulsatile group compared to the continuous perfusion group. In the pulsatile group, mortality was significantly lower (10.4% vs 25.6%) and low cardiac output syndrome was less frequent in the post-operative course.

Cardiopulmonary Bypass

A model of multicomponent cardiac fibre.

In order to simulate the contraction of a cardiac myofibre, a multicomponent fibre model has been developed. This model is composed of a series of segments which are activated in succession. Each segment is represented by the Hill's three component model of the sarcomere. The contractile element behaviour is described by the Huxley's theory and the time dependence agrees with the activation factor proposed by Julian for skeletal muscle, and modified by Wong for cardiac muscle. The two elastic elements have non-linear exponential characteristics. The isometric contraction of the multicomponent fibre has been simulated by means of a computer program. The results show the tension generated by the fibre, the propagation of the contraction along the fibre and the different contribution of each segment depending on its position inside the fibre.

Biomechanical Phenomena