PubMed Health⌕ Search

Biomedical subjects

F M Sandiford

Publications and source records attributed to F M Sandiford.

At least 37 records · Page 2Linked to original sources

Resection of left ventricular aneurysm. Report of 277 patients.

The prognosis of patients with LVA (left ventricular aneurysm) treated medically has been uniformly poor. Surgical resection of the ventricular aneurysm has been the treatment of choice at the Texas Heart Institute since 1958. A more accurate evaluation of patients with LVA by selective coronary arteriography has demonstrated significant associated CAD in over 75 percent of these patients. Since 1969, 125 patients with at lease one vessel suitable for bypass (group II) have undergone single, double or triple ACB in association with LVA resection; and 51 patients (group III) without significant conc-omitant CAD underwent LVA resection alone. To evaluate the efficacy of combined ACB and LVA resection, patients in group II and group III were compared to a third group of 101 patients who underwent LVA resection alone from 1958 to 1969 (group I). Operative mortality was higher in group I (19.8%) as compared to group II (12.8%) and group III (9.5%). Higher mortality was found to be related to a coronary artery score above 8.9, presence of left main coronary lesion, posterior or inferior location of the LVA, severe concomitant mitral valve insufficiency and incomplete revascularization of the remaining ventricular myocardium after LVA resection. Lower mortality and improved long-term results found in groups II and III as compared to group I appear to justify our choice of a "complete operation" in patients with LVA.

Coronary Artery Bypass↗

Complications of cloth-covered prosthetic valves: results with a new mitral prosthesis.

During a 12 year period 5,103 cardiac prosthetic valves in 4,193 patients have been evaluated for performance and incidence of complications. As a result of our experience, the advantages of fewer embolic phenomena, associated with epithelialization in completely cloth-covered valves and those with cloth-covered seating rings, are outweighed by the problems of cloth wear, hemolysis, and hemodynamic obstruction from tissue overgrowth. A valve has been designed which incorporates the desirable features of full-flow orifice, low-profile, self-washing principle, polished contact surfaces, durable materials, and a large eccentric sewing ring into a new mitral prosthesis. Clinical evaluation in 394 patients from Aug. 1, 1971, through Dec. 31, 1973, has demonstrated excellent hemodynamic function and a low incidence of thromboembolic phenomenon.

Heart Valve Prosthesis↗