PubMed Health⌕ Search

Biomedical subjects

F M Vogt

Publications and source records attributed to F M Vogt.

9 recordsLinked to original sources

[Whole-body tumor staging: MRI or FDG-PET/CT?].

Technical innovations such as the availability of movable patient platforms and the introduction of 32-channel systems have made whole-body MRI for tumor staging feasible. In addition, the development of dual-modality PET/CT systems offers the opportunity to perform anatometabolic tumor staging with whole-body coverage in a single session. Based on an increase in patient survival when applying a stage-adapted therapy in different malignant diseases the relevant question relates to the accuracies of whole-body MRI and whole-body PET/CT for TNM staging. This review article addresses whole-body tumor staging with MRI and FDG-PET/CT with special emphasis on diagnostic accuracies for staging different malignant diseases.

Aged↗

[Cardiovascular whole-body MRI: possibilities and limitations in prevention].

Cardiovascular disease is a major challenge to the healthcare with increasing prevalence in western societies. Hence, early detection of cardiovascular pathologies and preventative strategies will experience growing relevance in the future. Magnetic resonance imaging (MRI) nowadays allows a comprehensive analysis of the cardiovascular system. By combining separate examinations of brain, arterial vasculature, and heart the technique permits early detection of pathological changes with high diagnostic accuracy void of adverse events. Such a protocol has been proven feasible and technically robust and can be performed within 45 min. Inherent limitations are low spatial resolution of whole-body MR angiography and lack of functional stress testing of the heart. However, while being suitable as a fast and comprehensive imaging technique for cardiovascular screening purposes, medical consequences and socioeconomic relevance must further be elucidated.

Adult↗

Optimization of contrast-enhanced peripheral MR angiography with mid-femoral venous compression (VENCO).

PURPOSE: To compare a standard protocol for contrast-enhanced three-dimensional magnetic resonance angiography (3D CE-MRA) of the lower extremities to a high spatial resolution protocol with venous compression (VENCO) at the mid-femoral level. MATERIAL AND METHODS: 12 patients with peripheral arterial occlusive disease (8-males; age range, 52 - 74 years; mean 67.1 years; 4 females; age range, 57 - 71 years; mean 62.1 years) were examined once with a standard MR angiography (MRA) protocol, and a second time with a high spatial resolution protocol in combination with mid-femoral venous compression (60 mm Hg) for the last two stations. All imaging was performed on a 1.5 T whole-body MR scanner (Magnetom Sonata, Siemens Medical Solutions, Erlangen, Germany) using a dedicated coil and paramagnetic contrast agent (gadodiamide, Omniscan, Amersham, Oslo, Norway). Signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNR) were calculated and image quality as well as venous overlay were assessed on a five-point scale for both examinations. Statistical significance was established at p < 0.05. RESULTS: Mean SNR and CNR values of the two lower stations with VENCO were statistically significantly higher in comparison to the standard protocol (66 +/- 8 vs. 52 +/- 11 and 53 +/- 9 vs. 41 +/- 8, respectively; p < 0.01). The same was true for overall image quality with VENCO (4.0 +/- 0.2 vs. 3.4 +/- 0.8; p < 0.05) and presence of venous overlay (3.5 +/- 0.4 vs. 4.1 +/- 0.9; p < 0.05), respectively. CONCLUSION: VENCO 3D CE-MRA is simple to put into practice and advances the performance of multi-station MRA strategies for assessment of the peripheral arterial vasculature.

Aged↗

High spatial resolution whole-body MR angiography featuring parallel imaging: initial experience.

PURPOSE: To combine whole-body multi-station three-dimensional contrast enhanced magnetic resonance angiography (3D CE MRA) using a self-developed rolling table platform with parallel imaging strategies (PAT) in order to increase the spatial resolution of the 3D MRA data sets. MATERIALS AND METHODS: Whole-body multi-station MRA was performed with a rolling table platform (AngioSURF) on 5 volunteers in two imaging series: 1) standard imaging protocol, 2) modified high-resolution protocol employing PAT using the generalized autocalibrating partially parallel acquisitions (GRAPPA) algorithm with an acceleration factor of 3. For an intra-individual comparison of the two MR examinations, the arterial vasculature was divided into 30 segments. Signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNR) were calculated for all 30 arterial segments of each subject. Vessel segment depiction was qualitatively assessed applying a 5-point scale to each of the segments. Image reconstruction times were recorded for the standard as well as the PAT protocol. RESULTS: Compared to the standard protocol, PAT allowed for increased spatial resolution through a 3-fold reduction in mean voxel size for each of the 5 stations. Mean SNR and CNR values over all specified vessel segments decreased by a factor of 1.58 and 1.56, respectively. Despite the reduced SNR and CNR, the depiction of all specified vessel segments increased in PAT images, reflecting the increased spatial resolution. Qualitative comparison of standard and PAT images showed an increase in vessel segment conspicuity with more detailed depiction of intramuscular arterial branches in all volunteers. The time for image data reconstruction of all 5 stations was significantly increased from about 10 minutes to 40 minutes when using the PAT acquisition. CONCLUSION: The implementation of PAT into the concept of whole-body MRA enabled to increase the spatial resolution in all examined territories, which resulted in more detailed MR angiograms.

Adult↗

Dark lumen magnetic resonance colonography: comparison with conventional colonoscopy for the detection of colorectal pathology.

BACKGROUND: The purpose of this study was to assess the feasibility and usefulness of a new magnetic resonance (MR) colonography technique for the detection of colorectal pathology in comparison with conventional colonoscopy as the standard of reference. PATIENTS AND METHODS: A total of 122 subjects with suspected colorectal disease underwent "dark lumen" MR colonography. A contrast enhanced T1w three dimensional VIBE sequence was collected after rectal administration of water. The presence of colorectal masses and inflammatory lesions were documented. Results were compared with those of a subsequently performed colonoscopy. RESULTS: MR colonography was found to be accurate regarding detection of clinically relevant colonic lesions exceeding 5 mm in size, with sensitivity and specificity values of 93%/100%. CONCLUSION: Dark lumen MR colonography can be considered as a promising alternative method for the detection of colorectal disease. In addition, it allows assessment of extraluminal organs.

Adolescent↗

[Evaluation of myocardial viability with contrast-enhanced magnetic resonance imaging--comparison of the late enhancement technique with positronemission tomography].

PURPOSE: To compare contrast-enhanced magnetic resonance imaging (MRI) and positron emission tomography (PET) in the evaluation of myocardial viability. METHODS: [ (18)F]-FDG-PET, [ (201)Tl]-TlCl-SPECT and contrast-enhanced MRI were performed in 29 patients with proven coronary artery disease and impaired left ventricular function to assess myocardial viability. MRI scans were done on a 1.5 T scanner (Magnetom Sonata, Siemens, Germany). After the steady-state free precession cine study, 0.2 mmol/kg BW of Gd-DPTA (Magnevist(R), Schering, Germany) were administered i. v. For the detection of "late enhancement" (LE) indicating scar, left ventricular long axes and contiguous short axis slices of 8 mm thickness were scanned using an inversion recovery turbo gradient echo sequence (TR 8.0 ms; TE 4.0 ms; TI 180 - 240 ms; FA 20 degrees ). The evaluation of LE and FDG uptake in PET with perfusion defect in SPECT was done using an 8 (basal, mid) and 4 (apical) segment model in all short axes to cover the entire ventricle. The transmural extent of LE was assessed using a 4-point score system. Comparison between the two modalities was performed on a segmental basis. RESULTS: A total of 1753 segments were assessed. In MRI, 40 % of the segments showed myocardial scar, whereas PET revealed impaired uptake in 25 %. MRI obtained a very low interobserver variability in detecting myocardial scar (kappa 0.92). Using PET as the standard of reference in the segmental comparison, contrast-enhanced MRI yielded a sensitivity of 84 % and a specificity of 76 % for the detection of scar. 18 % of all segments showed LE but normal FDG uptake, 83 % of them referred to subendocardial scars. CONCLUSIONS: There is close agreement between contrast-enhanced MRI and PET in detecting transmural myocardial scars. Superior spatial resolution enables MRI to detect and quantify even subendocardial scar. Therefore, larger studies using functional recovery after revascularisation as an endpoint have to prove whether MRI might replace PET as the standard of reference in the assessment of myocardial viability.

Aged↗

[Modern diagnostic concepts in dissection and aortic occlusion].

For the diagnostic work-up of the aorta, non-invasive cross-sectional imaging techniques have almost replaced invasive catheter angiography. CT- and MR-angiography are supplemented by sonography which is used predominantly for the assessment of abdominal aortic aneurysm and dissections of the thoracic aorta. This review deals with the diagnostic approach to two disease entities involving the aorta: aortic dissection and aortic occlusion. Transoesophageal echocardiography (TEE), CT- and MR-angiography (MRA) are used in the assessment of aortic dissection. Published sensitivity and specificity values regarding the detection and classification of dissections into Stanford A and Stanford B range between 96-100% for all three modalities. Results for multislice CTA have not yet been reported, but can be expected to be at least as good. The ability to delineate additional information regarding the precise morphology of true and false lumen, entry and reentry-sites, the development of thrombus or paraaortic hematomas, as well as the assessment of aortic regurgitation or involvement of coronary arteries depend on the chosen technique. Reflecting the ability to collect functional imaging data, both TEE and MRA are superior to CTA in the assessment of aortic valve involvement, while TEE is the modality of choice for evaluation of coronary arteries. Sonography is of limited use in the assessment of abdominal dissections. For the evaluation of patients with suspected aortic occlusion both CTA and MRA represent the imaging modalities of choice. Both provide for a comprehensive and precise depiction of the underlying aortic morphology, the extent of collateral flow as well as delineation of distal run-off vessels. MRA should be employed in patients with impaired renal function as paramagnetic contrast agents are not nephrotoxic.

Aged↗

Dark lumen MR-colonography: initial experience.

PURPOSE: The aim of this study was to assess a new strategy of MR colonography for the detection of colonic polyps/malignancy. The technique is based on a rectal enema with water in combination with the intravenous application of a paramagnetic contrast agent. METHODS: Twelve subjects were included in this study either due to suspected colorectal tumors or for screening purposes. For MR colonography the colon was filled with approximately 3000 ml of tap water while Gadobenate dimeglumine (0.2 mmol/kg) was injected intravenously. A T1w GRE sequence was acquired before and 75 sec after the contrast administration only in prone position. Three patient underwent the "bright lumen" MRC as well. All MR examinations were performed at least five days prior to conventional colonoscopy and the results of both modalities were compared. RESULTS: The colonic filling with water resulted in a homogeneously low signal throughout the colonic lumen in all twelve subjects. Intravenous injection of gadolinium caused avid enhancement of the colonic wall. Similarly lesions arising from the colonic wall enhanced avidly. Dark lumen MR colonography correctly identified five polyps in four patients. Bright lumen MRC showed in one patient false positive results. CONCLUSION: The new MR colonography concept based on a dark colonic lumen and a bright, contrast enhanced colonic wall turned out to be a promising alternative to the traditional MRC based on a bright lumen concept. The new technique suggests a higher accuracy in detecting polyps, a better evaluation of other parenchymal organs as well as a reduced time needed for data acquisition and analysis.

Adult↗