Surface treatment of titanium for RD immobilization.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to F Mante.
Explore the source record for details and available documents.
In an attempt to increase retention of orthodontic bands, orthodontic companies market bands with surfaces prepared to increase roughness. A comparison of six groups of bands, including two with untreated surfaces, revealed a wide range of variation in shear forces. Three classes of retention may be differentiated on the basis of non-statistically significantly different mean shear forces in each category: high (Unitek, treated), moderate (Unitek, untreated; A Co., treated; GAC, treated), and low (A Co., untreated; Dentaurum, treated). Surface roughness, as evaluated through atomic force microscopy, correlated moderately with shear force (r = 0.61; p < 0.05). This method is examined and compared with the qualitative profiles of the orthodontic band surfaces provided by optical micrography.
Finite element analysis (FEA) has been proven to be a precise and applicable method for evaluating dental implant systems. By means of FEA, a parasaggital model was digitized from a computed tomography (CT)-generated patient data set, and various single-tooth, osseointegrated, two-dimensional dental implant models were simulated. The specific aims of the study were to: (1) examine the effect of implant diameter variation (3.8 mm-6.5 mm) of both a press-fit, stepped cylindrical implant type and a press-fit, straight cylindrical implant type as osseointegrated in the posterior mandible; (2) compare the stress-dissipating characteristics of the stepped implant versus the straight implant design; and (3) analyze the significance of bite force direction (vertical, horizontal, and oblique 45 degrees) on both implant types. The results of the FEA suggested that (1) using the widest diameter implant is not necessarily the best choice when considering stress distribution to surrounding bone, but within certain morphological limits, for both implant types, an optimum dental implant exists for decreasing the stress magnitudes at the bone-implant interface; (2) stress is more evenly dissipated throughout the stepped cylindrical implant when compared to the straight implant type; and (3) it is important in FEA of dental implants to consider not only axial forces (vertical loading) and horizontal forces (moment-causing loads), but also to consider a combined load (oblique bite force), since these are more realistic bite directions and for a given force will cause the highest localized stress in cortical bone. The theoretical analysis performed implies that clinically, whenever possible, an optimum, not necessarily larger, dental implant should be used based on the specific morphological limitations of the mandible and that a stepped cylindrical design for press-fit situations is most desirable from the standpoint of stress distribution to surrounding bone.
Four methods of enamel preparation before orthodontic bonding that are currently in use or proposed for use were investigated. The study consisted of two parts. Part one evaluated the roughness of the prepared enamel surfaces by using optical profilometry and scanning electron microscopy (SEM). Part two compared the debonding force for the prepared enamel surfaces by using a mechanical testing machine. The teeth were divided into four groups as follows: In group A, the surfaces were only sandblasted. In group B, the surfaces were sandblasted and acid etched. In group C, the surfaces were buffed with an 1172 fluted bur and acid etched. In group D, the surfaces were pumiced and acid etched. There was no statistical difference in surface roughness among the four groups at p < 0.05, nor was there any statistical difference in bond strength among the three groups that were acid etched. However, there was a significant difference in bond strength between these groups and the group that received only sandblasting (no acid etching). Thus, in this preliminary study, sandblasting does not appear to damage the enamel surface and can therefore be used as a substitute for polishing with pumice. It should be followed by acid etching to produce enamel surfaces with comparable bond strengths.
The role of the Periotest in the clinical evaluation of osseointegration has been well documented. Some clinicians have used the initial Periotest values at second-stage surgery as a baseline to measure changes in integration at the bone-implant interface over time. The purpose of this pilot study was to compare Periotest values made with and without healing abutments in place. A statistically significant difference was found between the Periotest values that were recorded with and without healing abutments, with the values without the healing abutments being more negative and suggestive of greater osseointegration.
The effect of an Ag-Cu-Pd dispersant alloy on the structure of amalgams fabricated with two different particle types of low-copper amalgam matrices was investigated. In amalgams L and L (0), a low-copper lathe-cut amalgam Aristalloy was used as the matrix. In amalgams S and S(0), the matrix used was Spheralloy, a low-copper spherical amalgam. X-ray diffraction was used to analyse the relative content of the phases in the amalgams. The presence of Pd in the dispersant of amalgams L and S resulted in a decrease in the amount of eta' (Cu6Sn5) and an increase in the amount of unreacted particles when compared to the controls L(0) and S(0). Amalgams fabricated with a spherical alloy matrix (S and S(0)) showed a greater effect than amalgams fabricated with a lathe-cut matrix alloy (L and L(0)).
The softening of post-cure, heat-treated dental composites in various solutions was evaluated by Knoop hardness measurements. The samples were heated at 120 degrees C for 7 min immediately after curing and immersed in various solutions, water, ethanol, heptane and 0.1 N NaOH. Significant increases in hardness were observed for heated samples when compared to unheated samples. The various solutions softened both heated and unheated composites but heated samples were softened to a lesser degree. Plots of hardness of heated and unheated samples were nearly parallel, indicating that mechanisms such as penetration of the resin matrix, degradation of the silane coupling agent and fillers may be involved in the softening of both heated and unheated composites. Post-cure heat treatment improved the resistance to softening of dental composites.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.