[Comparative evaluation of different kits for serum digoxin determination (author's transl)].

In the last years the determination of serum digoxin levels has become absolutely necessary not only in specialized centers but also in all medical departments for its pharmacological and clinical implications. In order to verify the reproducibility, accurateness and sensibility of the techniques currently employed we performed a comparative analysis of the serum digoxin levels obtained by using one immuno-enzymatic and four different radio-immuno-assay kits. The first in vitro trial was performed by evaluating serum digitalis on blood specimens from eight healthy human donors to which known doses of digoxin and beta-methyl-digoxin had been added. The second in vivo trial was performed by giving for three days to sixteen cardiac patients, previously off any digitalis treatment, only one oral morning dose of 0.125 mg of digoxin (8 patients), and 0.135 mg of beta-methyl-digoxin (8 patients). A monoexponential decay constant was calculated on the curves of serum digitalis levels, measured in the third day of treatment by means of the five different techniques. The statistical analysis, performed on the results we obtained, demonstrates a satisfying degree of reproducibility and accurateness only for some of the kits used. This is due to a poor sensibility of some kits in the presence of low digitalis levels, which can produce significantly different value for the decay constant (p < 0.02). Such a behaviour possibly due to different manufacturing processes of the kits raises some questions on the validity in comparing results from various laboratories when different testing procedures are employed.

Digoxin

[Kinetics of beta-methyl-digoxin in different degrees of renal function (author's transl)].

Creatinine clearance was evaluated in individuals with varying degrees of renal function following the administration of beta-methyl-digoxin. From the results of the experiment it can be deduced that significantly increased hematic values and renal clearance values definitely lower than normal appear only in patients of a creatinine clearance of less than 50 ml/min. Furthermore, a positive correlation between creatinine clearance values and beta-methyl-digoxin levels was noticed. This correlation was in proportion to the amount of serum albumin. The degree of distribution of free digitalis and digitalis bound to proteins within the vascular system played an important role in the complex kinetics of digoxin. This relationship is suggested as an indirect index of the proportions of free beta-methyl-digoxin and of beta-methyl-digoxin bound to plasma proteins.

Creatinine

[Kinetics of beta-methyl-digoxin in various degrees of renal function].

A radioimmunologic assay method was employed for assessing the hematic and urinary levels of beta methyl-digoxin in patients with various degrees of renal function, evaluated by creatinine clearance test. Significantly elevated hematic values and reduced clearance rates of MD were observed only in patients whose creatinine clearance values were below 50 cc/min. A good correlation between values of creatinine and MD clearances and between their ratio and serum albumin levels was verified. The authors stress the usefulness of this ratio as an indirect index for the plasmatic percentage of the free and of the protein- bound fractions of MD.

Adolescent