PubMed Health⌕ Search

Biomedical subjects

F Migliavacca

Publications and source records attributed to F Migliavacca.

At least 19 recordsLinked to original sources

Multiscale modelling as a tool to prescribe realistic boundary conditions for the study of surgical procedures.

This work was motivated by the problems of analysing detailed 3D models of vascular districts with complex anatomy. It suggests an approach to prescribing realistic boundary conditions to use in order to obtain information on local as well as global haemodynamics. A method was developed which simultaneously solves Navier-Stokes equations for local information and a non-linear system of ordinary differential equations for global information. This is based on the principle that an anatomically detailed 3D model of a cardiovascular district can be achieved by using the finite element method. In turn the finite element method requires a specific boundary condition set. The approach outlined in this work is to include the system of ordinary differential equations in the boundary condition set. Such a multiscale approach was first applied to two controls: (i) a 3D model of a straight tube in a simple hydraulic network and (ii) a 3D model of a straight coronary vessel in a lumped-parameter model of the cardiovascular system. The results obtained are very close to the solutions available for the pipe geometry. This paper also presents preliminary results from the application of the methodology to a particular haemodynamic problem: namely the fluid dynamics of a systemic-to-pulmonary shunt in paediatric cardiac surgery.

Arteriovenous Shunt, Surgical↗

In vitro steady-flow analysis of systemic-to-pulmonary shunt haemodynamics.

A modified Blalock-Taussig shunt is a connection created between the systemic and pulmonary arterial circulations to improve pulmonary perfusion in children with congenital heart diseases. Survival of these patients is critically dependent on blood flow distribution between the pulmonary and systemic circulations which in turn depends upon the flow resistance of the shunt. Previously, we investigated the pressure-flow relationship in rigid shunts with a computational approach. to estimate the pulmonary blood flow rate on the basis of the in vivo measured pressure drop. The present study aims at evaluating, in vitro how the anastomotic distensibility and restrictions due to suture presence affect the shunt pressure-flow relationship. Two actual Gore-Tex shunts (3 and 4 mm diameters) were sutured to compliant conduits by a surgeon and tested at different steady flow rates (0.25-11 min(-1)) and pulmonary pressures (3-34 mmHg). Corresponding computational models were also created to investigate the role of the anastomotic restrictions due to sutures. In vitro experiments showed that pulmonary artery pressure affects the pressure-flow relationship of the anastomoses. particularly at the distal site. However, this occurrence scarcely influences the total shunt pressure drop. Comparisons between in vitro and computational models without anastomotic restrictions show that the latter underestimates the in vitro pressure drops at any flow rate. The addition of the anastomotic restrictions (31 and 47% of the original area of 3 and 4 mm shunts, respectively) to the computational models reduces the gap, especially at high shunt flow rate and high pulmonary pressure.

Anastomosis, Surgical↗

Effects of pulmonary afterload on the hemodynamics after the hemi-Fontan procedure.

A computational fluid dynamics study based on the application of the finite volume method has been performed to investigate the effects of the pulmonary afterload on the hemodynamics after the hemi-Fontan procedure. This operation is generally used as part of a series of staged procedures to treat complex congenital malformations of the heart. It consists of re-directing the superior vena caval flow from the right atrium into the pulmonary arteries, by-passing the right ventricle while excluding the inferior caval flow from the lungs. To reproduce correctly the pulmonary afterload conditions, a simplified lumped-parameter mechanical model of the pulmonary circulation has been developed and linked to the finite volume solver. In addition, the effect of a stenosis in the left pulmonary artery was also examined. In this paper the adopted methodology is presented, together with some of the preliminary results. The model has been used to simulate the local fluid dynamics for different values of the pulmonary arteriolar resistance and lung resistances, allowing a quantitative evaluation of the dissipated energy and the flow distribution into the lungs. The results show that both flow distribution into the lungs and energy dissipation after the hemi-Fontan procedure are only minimally affected by the pulmonary arteriolar resistance.

Biomedical Engineering↗

Subdiaphragmatic venous hemodynamics in the Fontan circulation.

OBJECTIVE: We investigated the subdiaphragmatic venous physiology in patients subjected to the Fontan operation to understand some of the early and late problems of this circulation. METHODS: Flows were evaluated by Doppler ultrasonography in the subhepatic inferior vena cava, hepatic vein, and portal vein during respiratory monitoring and with a tilt table. Twenty control subjects (group A) and 56 patients who had the Fontan operation, 27 in functional class I (group B) and 29 in class III or IV (group C), were studied. Inspiratory/expiratory flow ratio was calculated to reflect respiratory effects, and upright/supine flow ratio was calculated to assess gravity effects. Inferior vena caval, hepatic venous, and wedged hepatic venous pressures were measured during catheterization in 21 control subjects and 25 Fontan patients. The difference between wedged and hepatic venous pressures represents the transhepatic venous pressure gradient. RESULTS: Fontan hepatic venous flow depended more on inspiration than control, but without difference between groups B and C (inspiratory/expiratory flow ratios: 1.7, 2.9, and 2.9, respectively; P <.02). Normal portal venous flow was higher in expiration; this effect was lost in group B and reversed in group C (inspiratory/expiratory flow ratios: 0.8, 1.0, and 1.3; P <.0005). Gravity reduced portal venous flow in groups A and B, but progression to functional class III or IV (group C) exacerbated this effect (upright/supine flow ratios: 0.8, 0.7, and 0.5; P <.01). Inferior vena caval, hepatic venous, and wedged hepatic venous pressures (in millimeters of mercury) in the Fontan groups were all elevated compared with the control group (inferior vena cava, 14.4 +/- 4.4 vs 5.9 +/- 2.3; hepatic vein, 14.7 +/- 4.5 vs 5.9 +/- 1.9; wedged hepatic vein, 14.7 +/- 4.0 vs 8.3 +/- 2.6; P <.0001). However, transhepatic venous pressure gradient in the Fontan group was lower than in the control group (0.5 +/- 0.5 vs 2.4 +/- 2.0; P <.001). Univariate analysis of inferior vena caval pressure and transhepatic venous pressure gradient showed significant inverse correlation (r = 0.6, P <.002). CONCLUSIONS: In patients who are in functionally poorer condition after the Fontan operation, portal venous flow loses normal expiratory augmentation and adverse gravity influence is enhanced. These suboptimal flow dynamics, coupled with higher splanchnic venous pressures and lower transhepatic venous pressure gradients, suggest that hepatic sinusoids are congested, acting as "open tubes." Transhepatic gradient loss is incrementally worse with higher caval pressures. These observations may be responsible for late gastrointestinal problems in patients who have had the Fontan operation.

Adolescent↗

Modeling of the Norwood circulation: effects of shunt size, vascular resistances, and heart rate.

Hypoplastic left heart syndrome is the most common lethal cardiac malformation of the newborn. Its treatment, apart from heart transplantation, is the Norwood operation. The initial procedure for this staged repair consists of reconstructing a circulation where a single outlet from the heart provides systemic perfusion and an interpositioning shunt contributes blood flow to the lungs. To better understand this unique physiology, a computational model of the Norwood circulation was constructed on the basis of compartmental analysis. Influences of shunt diameter, systemic and pulmonary vascular resistance, and heart rate on the cardiovascular dynamics and oxygenation were studied. Simulations showed that 1) larger shunts diverted an increased proportion of cardiac output to the lungs, away from systemic perfusion, resulting in poorer O2 delivery, 2) systemic vascular resistance exerted more effect on hemodynamics than pulmonary vascular resistance, 3) systemic arterial oxygenation was minimally influenced by heart rate changes, 4) there was a better correlation between venous O2 saturation and O2 delivery than between arterial O2 saturation and O2 delivery, and 5) a pulmonary-to-systemic blood flow ratio of 1 resulted in optimal O2 delivery in all physiological states and shunt sizes.

Computer Simulation↗

Effects of respiration and gravity on infradiaphragmatic venous flow in normal and Fontan patients.

BACKGROUND: In the Fontan circulation, pulmonary and systemic vascular resistances are in series. The implications of this unique arrangement on infradiaphragmatic venous physiology are poorly understood. METHODS AND RESULTS: We studied the effects of respiration and gravity on infradiaphragmatic venous flows in 20 normal healthy volunteers (control) and 48 Fontan patients (atriopulmonary connection [APC] n=15, total cavopulmonary connection [TCPC] n=30). Hepatic venous (HV), subhepatic inferior vena caval (IVC), and portal venous (PV) flow rates were measured with Doppler ultrasonography during inspiration and expiration in both the supine and upright positions. The inspiratory-to-expiratory flow rate ratio was calculated to reflect the effect of respiration, and the supine-to-upright flow rate ratio was calculated to assess the effect of gravity. HV flow depended heavily on inspiration in TCPC compared with both control and APC subjects (inspiratory-to-expiratory flow rate ratio 3.4, 1.7, and 1.6, respectively; P:<0.0001). Normal PV flow was higher in expiration, but this effect was lost in TCPC and APC patients (inspiratory-to-expiratory flow rate ratio 0.8, 1.0, and 1.1, respectively; P:=0.01). The respiratory influence on IVC flow was the same in all groups. Gravity decreased HV flow more in APC than in TCPC patients (supine-to-upright flow rate ratio 3.2 versus 2.1, respectively; P:<0.04) but reduced PV flow equally in all groups. CONCLUSIONS: Gravity and respiration have important influences on infradiaphragmatic venous return in Fontan patients. Although gravity exerts a significant detrimental effect on lower body venous return, which is more marked in APC than in TCPC patients, the beneficial effects of respiration in TCPC patients are mediated primarily by an increase in HV flow. These effects may have important short- and long-term implications for the hemodynamics of the Fontan circulation.

Adolescent↗

Use of mathematical model to predict hemodynamics in cavopulmonary anastomosis with persistent forward flow.

BACKGROUND: The bidirectional cavopulmonary anastomosis with additional pulmonary blood flow is used as a staged procedure or a definitive palliation of univentricular hearts. In this paper the flow competition occurring between the caval and the pulmonary flows is investigated. The hemodynamics in the superior vena cava and the blood flow distribution into the lungs, as well as the systemic arterial oxygen availability, are correlated with the severity of the right ventricle outflow tract obstruction and the pulmonary arteriolar resistance. MATERIALS AND METHODS: Computer models of the pre- and postoperative hemodynamics of univentricular hearts were developed. The effects of increasing severity of the right ventricle outflow tract obstruction, with a pulmonary arteriolar resistance ranging from 0.8 to 7.9 nonindexed Woods units, were simulated. RESULTS: The study indicates that the presence of an additional pulmonary blood flow from the native pulmonary artery may be beneficial. Since an excessive additional blood flow may cause central venous hypertension, its optimal value should be chosen according to the value of pulmonary arteriolar resistance. The model was utilized to simulate four clinical cases. CONCLUSIONS: The simulations show that the model can predict the postoperative hemodynamics and could therefore be usefully applied to predict quantitatively the effect of the native pulmonary blood flow following bidirectional cavopulmonary anastomosis.

Anastomosis, Surgical↗

Computational model of the fluid dynamics in systemic-to-pulmonary shunts.

A systemic-to-pulmonary shunt is a connection created between the systemic and pulmonary arterial circulations in order to improve pulmonary perfusion in children with congenital heart diseases. Knowledge of the relationship between pressure and flow in this new, surgically created, cardiovascular district may be helpful in the clinical management of these patients, whose survival is critically dependent on the blood flow distribution between the pulmonary and systemic circulations. In this study a group of three-dimensional computational models of the shunt have been investigated under steady-state and pulsatile conditions by means of a finite element analysis. The model is used to quantify the effects of shunt diameter (D), curvature, angle, and pulsatility on the pressure-flow (DeltaP-Q) relationship of the shunt. Size of the shunt is the main regulator of pressure-flow relationship. Innominate arterial diameter and angles of insertion have less influence. Curvature of the shunt results in lower pressure drops. Inertial effects can be neglected. The following simplified formulae are derived: DeltaP=(0. 097Q+0.521Q(2))/D(4) and DeltaP=(0.096Q+0.393Q(2))/D(4) for the different shunt geometries investigated (straight and curved shunts, respectively).

Blood Circulation↗

Calculating blood flow from Doppler measurements in the systemic-to-pulmonary artery shunt after the Norwood operation: a method based on computational fluid dynamics.

Hypoplastic left heart syndrome is currently the most lethal cardiac malformation of the newborn infant. Survival following a Norwood operation depends on the balance between systemic and pulmonary blood flow, which is highly dependent on the fluid dynamics through the interposition shunt between the two circulations. We used computational fluid dynamic (CFD) models to determine the velocity profile in a systemic-to-pulmonary artery shunt and suggested a simplified method of calculating the blood flow in the shunt based on Doppler measurements. CFD models of systemic-to-pulmonary shunts based on the finite element method were studied. The size of the shunt has been varied from 3 to 5 mm. Velocity profiles at proximal and distal positions were evaluated and correlations between maximum and mean spatial velocity were found. Twenty-one Doppler measurements in the proximal and distal part of the shunt were obtained from six patients with hypoplastic left heart syndrome. Combining Doppler velocities and CFD velocity profiles, blood flow rate in the shunt was calculated. Flow rate evaluated from aortic Doppler and oxygen saturation measurements were performed for comparison. Results showed that proximal shunt Doppler velocities were always greater than the correspondent distal ones (ratio equal to 1.15 +/- 0.11). CFD models showed a similar behaviour (ratio equal to 1.21 +/- 0.03). CFD models gave a V(mean)/V(max) ratio of 0. 480 at the proximal junction and of 0.579 at the distal one. The agreement between the flow evaluated in the proximal and distal areas of the shunt was good (0.576 +/- 0.150 vs. 0.610 +/- 0.166 l/min). Comparison of these data with saturation data and aortic Doppler measurements correlate less well (0.593 +/- 0.156 vs. 1.023 +/- 0.493 l/min). A formula easily to quantify shunt flow rate is proposed. This could be used to evaluate the effects of different therapeutic and pharmacological manoeuvres in this unique circulation.

Anastomosis, Surgical↗

Computational fluid dynamic simulations of cavopulmonary connections with an extracardiac lateral conduit.

Complex congenital heart defects due to the absence of a ventricular chamber can often be treated by the Fontan surgical procedure. The objective of this work was to quantify the haemodynamics in the Fontan operation (cavopulmonary connection) with extracardiac lateral conduit. Four different models based on the finite element method were constructed with different lengths of inferior anastomosis (range 18-25 mm) and inclinations of the conduit (33 and 47.5 degrees). Mass conservation and Navier-Stokes equations were solved by means of the FIDAP code, based on the finite element method. The left-to-right pulmonary flow ratio and percentage inferior caval blood to the left lung were the highest with the smallest anastomosis and highest inclination: 1.35 and 83.26%, respectively. Dissipated power percentage was higher with the largest anastomosis than with the smallest (19.4 vs 15.8%). It was concluded that, when performing a total cavopulmonary connection, an extracardiac lateral conduit: (i) diverts more flow to the left lung, and (ii) shows higher energy losses when compared with a connection with intra-atrial tunnel. This study could be useful to evaluate the incidence of pulmonary arteriovenous malformations.

Arteriovenous Shunt, Surgical↗

Computational fluid dynamic and magnetic resonance analyses of flow distribution between the lungs after total cavopulmonary connection.

Total cavopulmonary connection is a surgical procedure adopted to treat complex congenital malformations of the right heart. It consists basically in a connection of both venae cavae directly to the right pulmonary artery. In this paper a three-dimensional model of this connection is presented, which is based on in vivo measurements performed by means of magnetic resonance. The model was developed by means of computational fluid dynamics techniques, namely the finite element method. The aim of this study was to verify the capability of such a model to predict the distribution of the blood flow into the pulmonary arteries, by comparison with in vivo velocity measurements. Different simulations were performed on a single clinical case to test the sensitivity of the model to different boundary conditions, in terms of inlet velocity profiles as well as outlet pressure levels. Results showed that the flow distribution between the lungs is slightly affected by the shape of inlet velocity profiles, whereas it is influenced by different pressure levels to a greater extent.

Adolescent↗

Computational transient simulations with varying degree and shape of pulmonic stenosis in models of the bidirectional cavopulmonary anastomosis.

The bidirectional cavopulmonary anastomosis is a surgical technique utilized to treat severe congenital malformations of the right part of the heart. It is obtained by anastomosing the superior vena cava to the superior aspect of the undivided right pulmonary artery. Transient simulations with a three-dimensional model of the bidirectional cavopulmonary anastomosis were carried out to evaluate the haemodynamics of different types of pulmonic stenosis (shape and severity of the obstruction). Models with a tunnel-like (supravalvar) or discrete (valvar) pulmonic stenosis with different values of reduction of cross-sectional area (60 and 75%) were investigated and compared to a model without stenosis. Calculations were based on a finite element method analysis. The results showed that a tighter stenosis can lead to a blood volume flow to the left lung reaching 70% of the total pulmonary flow. Moreover, the flow fields are highly influenced by the presence and shape of the pulmonic stenosis; the most intense jets in the left pulmonary artery occur for a discrete pulmonic stenosis of 75%. The flow in the right pulmonary artery is nearly steady because it is damped down by the steady caval flow.

Anastomosis, Surgical↗

A mathematical model of circulation in the presence of the bidirectional cavopulmonary anastomosis in children with a univentricular heart.

The bidirectional cavopulmonary anastomosis is used as a staged procedure or a definitive palliation of univentricular hearts. It is often performed in the presence of an additional blood flow arising from the native pulmonary outflow tract. In this paper, the effects of the severity of the pulmonary outflow obstruction and the pulmonary arteriolar resistance are analysed with regard to the haemodynamics in the superior vena cava and the blood distribution into the lungs. A computer model has been developed, which can represent both the preoperative and the postoperative (systemic and pulmonary) circulations in a patient with a double-outlet univentricular heart. It is particularly detailed in the region of the large vessels and includes components that account for local three-dimensional effects due to the actual shape of the anastomosis. Results have indicated that the mean pressure in the superior vena cava increases from 8.2 to 19.2 mmHg with pulmonary arteriolar resistance ranging from 0.8 to 7.9 Woods units and pulmonary outflow obstruction ranging from 50 to 100%. The percentage flow distribution to the right lung has turned out to be heavily affected by the flow competition and has ranged from 43 to 50% of the total flow to the lungs in the systolic phase, and from 51 to 62% in the diastolic phase. The model allows routinely used clinical indices to be computed, as well as the evaluation of new indices, which is potentially helpful in the clinical assessment of postoperative haemodynamics (e.g. the right-to-left lung flow ratio and the superior vena cava-to-pulmonary flow ratio).

Biophysical Phenomena↗

Use of computational fluid dynamics in the design of surgical procedures: application to the study of competitive flows in cavo-pulmonary connections.

Computational fluid dynamic methods based on a finite-element technique were applied to the study of (1) competition of flows in the inferior and superior venae cavae in total cavopulmonary connection, and (2) competition between flow in the superior vena cava and forward flow from a stenosed pulmonary artery in bidirectional cavopulmonary anastomosis. Models corresponding to various degrees of offsetting and shape of the inferior vena caval anastomosis were simulated to evaluate energy dissipation and flow distribution between the two lungs. A minimal energy loss with optimal flow distribution between the two lungs was obtained by enlarging the inferior vena caval anastomosis toward the right pulmonary artery. This modified technique of total cavopulmonary connection is described. A computational model of the operation was developed in an attempt to understand the mechanisms of postoperative failure. In tight pulmonary artery stenosis (75%), the pulsatile forward flow is primarily directed to the left pulmonary artery, with little influence on superior vena caval pressure and the right pulmonary artery. Pulsatile forward flows corresponding to 15%, 30%, 45%, and 60% of the systemic artery output increased the mean pulmonary artery and superior vena caval pressures by 1, 1.7, 2.4, and 3.6 mm Hg, respectively. Although the modeling studies were not able to determine the cause of postoperative failure, they emphasize the impact of local geometry on flow dynamics. More simulations are required for further investigation of the problem.

Anastomosis, Surgical↗

Numerical analysis of steady flow in aorto-coronary bypass 3-D model.

Intimal hyperplasia and atherosclerosis have a predominant role in the failure of coronary artery bypass procedures. Theoretical studies and in vivo observations have shown that these pathologies are much more likely to occur in the proximity of end-to-side anastomosis, thus indicating that fluid dynamic conditions may be included in the pathogenic causes of the initiation, progression and complication of intimal hyperplasia. In order to study the fluid dynamics at the anastomosis of an aortocoronary bypass, a three-dimensional mathematical model based on a FEM approach was developed. Steady-state simulations were studied in two different geometrical models of anastomosis which differ in their insertion angles (45 and 60 degree). Flow fields with three-dimensional helical patterns, secondary flows, and shear stresses were also investigated. The results show the presence of low shear stresses on the top wall just beyond the toe of the anastomosis and in the region of the coronary artery before the junction. A high wall shear stress region is present on the lateral wall of the coronary artery immediately downstream from the anastomosis. The influence of flow rate distribution on the secondary flows is also illustrated. These results confirm the sensitivity of flow behavior to the model's geometrical parameters and enhance the importance of reproducing the anastomosis junction as closely as possible in order to evaluate the effective shear stress distribution.

Anastomosis, Surgical↗

A computational pulsatile model of the bidirectional cavopulmonary anastomosis: the influence of pulmonary forward flow.

The bidirectional cavopulmonary anastomosis (BCPA or bidirectional Glenn) is an operation to treat congenital heart diseases of the right heart by diverting the systemic venous return from the superior vena cava to both lungs. The main goal is to provide the correct perfusion to both lungs avoiding an excessive increase in systemic venous pressure. One of the factors which can affect the clinical outcome of the surgically reconstructed circulation is the amount of pulsatile blood flow coming from the main pulmonary artery. The purpose of this work is to analyse the influence of this factor on the BCPA hemodynamics. A 3-D finite element model of the BCPA has been developed to reproduce the flow of the surgically reconstructed district. Geometry and hemodynamic data have been taken from angiocardiogram and catheterization reports, respectively. On the basis of the developed 3-D model, four simulations have been performed with increasing pulsatile blood flow rate from the main pulmonary artery. The results show that hemodynamics in the pulmonary arteries are greatly influenced by the amount of flow through the native main pulmonary artery and that the flow from the superior vena cava allows to have a similar distribution of the blood to both lungs, with a little predilection for the left side, in agreement with clinical postoperative data.

Blood Flow Velocity↗

Medulloblastoma. Results of a sequential combined treatment.

Actuarial progression-free survival rate at 5 years of a series of 34 patients with medulloblastoma treated by combined surgery, radiotherapy, and chemotherapy was 71%. No relapses were observed in 14 patients followed for more than 5 years. Treatment consisted of a short postoperative course of vincristine (VCR) and intrathecal (IT) methotrexate (MTX) followed by irradiation to the entire cranio spinal axis. Maintenance chemotherapy (CCNU, VCR, and IT MTX) was then continued to encompass 2 years from surgery. Failure occurred in nine patients: four had local recurrence, four dissemination within the central nervous system, and one widespread skeletal metastases. Poor prognostic factors such as presence of malignant cells in the cerebrospinal fluid, non-radical surgery, young age, and radiation doses less than 50 Gy to the tumor bed, did not adversely affect the outcome of patients in this series. Long-term sequelae from the treatment program could be observed in all patients, and in 58% they were severe enough to interfere with normal, active life.

Adolescent↗