PubMed Health⌕ Search

Biomedical subjects

F Montero de Espinosa

Publications and source records attributed to F Montero de Espinosa.

2 recordsLinked to original sources

Nonlinear characterization with burst excitation of 1-3 piezocomposite transducers.

Ultrasonic transducers made with 1-3 connectivity piezocomposites are frequently used in Medical applications and nondestructive testing. When the transducer is used for special applications as, for instance air-coupled transmission, it is necessary to compensate for the high difference of acoustic impedance between transducer and medium using high amplitude pulses to generate high acoustic signal. Thus, the nonlinear behavior of the transducer must be taken into account in similar application conditions. The newly developed method, which performs the nonlinear characterization with burst signal excitation near the thickness resonance frequency, is based on the measure of the current as well as the vibration velocity of the piezocomposite transducer. The current of the stationary response is measured before the end of the burst signal excitation. Burst excitation enables us to measure the nonlinear characterization without producing overheating in the transducers. The amplitude level dependence of mechanical losses tandelta(m) and the stiffness increases |Deltac/c(0)| have been studied, as well as the velocity dependence of a point of the transducer, measured with a laser vibrometer. In this method, the power level applied to the transducers can be higher than other nonlinear measurement methods, providing measurements of high accuracy.

Equipment Design↗

64 elements two-dimensional piezoelectric array for 3D imaging.

Ultrasound has a large potential on non-invasive inspection with main applications in medical imaging and non-destructive testing (NDT). The increasing interest in 3D imaging applications leads to investigate new solutions for two-dimensional (2D) ultrasonic arrays with an affordable number of electronic channels without resolution degradation. 2D segmented annular arrays (SAAs) are a good compromise between resolution--image quality--and number of electronically active channels. A 1-3 piezoelectric composites are used as basis material to manufacture the array transducers due to their low planar coupling and high electromechanical coupling coefficients. A 1.5 MHz SAA of 64 elements and 20 mm of diameter was designed, manufactured and tested. The design key point is the use of a flexible circuit with electrodes and tracks that define the array geometry. The piezocomposite was used as a monolithic support. Soft backing and one matching layer were used. The array elements have been tested electrically and acoustically showing good agreement with a KLM-based simulation model. Acoustical field measurements in water at different steering angles were made and compared with simulations performed with a model that uses an exact solution of the impulse response approach. Side lobes are important because the array geometry used was designed to work in metals for NDT purposes. Smaller array elements should be made for medical applications.

Imaging, Three-Dimensional↗