Optimization of intensity modulated radiotherapy under constraints for static and dynamic MLC delivery.

Multi-leaf collimators (MLCs) are emerging as the prevalent modality to apply intensity modulated radiotherapy (IMRT). Both the principle and the particular design of MLCs stipulate complex constraints on the practically applicable intensity modulated radiation fields. Most consequentially, the distribution of exposure times across the maximum field outline is either a piecewise constant function in the static mode or a piecewise linear function in the dynamic mode of driving an MLC. In view of clinical utility, the total leaf movement should be minimized, which requires that MLC-related constraints be considered in the dose optimization process. A method is proposed to achieve this for both static MLC fields and dynamic leaf close-in application. The method is an amendment to a generic gradient-based IMRT dose optimization algorithm and solves numerical problems related to the non-convexity of the MLC constraints, which can cause erratic behaviour of a gradient-based algorithm. It employs bistable penalty functions to select preferrable leaf configurations from the configuration space of the MLC, which is limited by specific design features. Together with an 'annealing' escape mechanism from local minima, the algorithm is capable of finding the optimum of an IMRT problem as leaf sequences with minimized leaf travel. In particular, the efficiency of static IMRT can be raised to the levels of unmodulated fields with very few field segments, thereby increasing the utility of IMRT in clinical practice.

Algorithms↗

A representation of an NTCP function for local complication mechanisms.

A mathematical formalism was tailored for the description of mechanisms complicating radiation therapy with a predominantly local component. The functional representation of an NTCP function was developed based on the notion that it has to be robust against population averages in order to be applicable to experimental data. The model was required to be invariant under scaling operations of the dose and the irradiated volume. The NTCP function was derived from the model assumptions that the complication is a consequence of local tissue damage and that the probability of local damage in a small reference volume is independent of the neighbouring volumes. The performance of the model was demonstrated with an animal model which has been published previously (Powers et al 1998 Radiother. Oncol. 46 297-306).

Animals↗

Intensity modulated irradiation of a thorax phantom: comparisons between measurements, Monte Carlo calculations and pencil beam calculations.

The present study investigates the application of compensators for the intensity modulated irradiation of a thorax phantom. Measurements are compared with Monte Carlo and standard pencil beam algorithm dose calculations. Compensators were manufactured to produce the intensity profiles that were generated from the scientific version of the KonRad IMRT treatment-planning system for a given treatment plan. The comparison of dose distributions calculated with a pencil beam algorithm, with the Monte Carlo code EGS4 and with measurements is presented. By measurements in a water phantom it is demonstrated that the method used to manufacture the compensators reproduces the intensity profiles in a suitable manner. Monte Carlo simulations in a water phantom show that the accelerator head model used for simulations is sufficient. No significant overestimations of dose values inside the target volume by the pencil beam algorithm are found in the thorax phantom. An overestimation of dose values in lung by the pencil beam algorithm is also not found. Expected dose calculation errors of the pencil beam algorithm are suppressed, because the dose to the low density region lung is reduced by the use of a non-coplanar beam arrangement and by intensity modulation.

Dose-Response Relationship, Radiation↗

A variable fluence step clustering and segmentation algorithm for step and shoot IMRT.

A step and shoot sequencer was developed that can be integrated into an IMRT optimization algorithm. The method uses non-uniform fluence steps and is adopted to the constraints of an MLC. It consists of a clustering, a smoothing and a segmentation routine. The performance of the algorithm is demonstrated for eight mathematical profiles of differing complexity and two optimized profiles of a clinical prostate case. The results in terms of stability, flexibility, speed and conformity fulfil the criteria for the integration into the optimization concept. The performance of the clustering routine is compared with another previously published one (Bortfeld et al 1994 Int. J. Radiat. Oncol. Biol. Ph.vs. 28 723-30) and yields slightly better results in terms of mean and maximum deviation between the optimized and the clustered protile. We discuss the specific attributes of the algorithm concerning its integration into the optimization concept.

Algorithms↗

Electron dosimetry based on the absorbed dose to water concept: a comparison of the AAPM TG-51 and DIN 6800-2 protocols.

The dosimetry protocols DIN 6800-2 and AAPM TG-51, both based on the absorbed dose to water concept, are compared in their theoretical background and in their application to electron dosimetry. The agreement and disagreement in correction factors and energy parameters used in both protocols will be shown and discussed. Measurements with three different types of ionization chambers were performed and evaluated according to both protocols. As a result the perturbation correction factor P(60Co)wall for the Roos chamber was determined to 1.024 +/- 0.5%.

Algorithms↗

Monte Carlo dose computation for IMRT optimization.

A method which combines the accuracy of Monte Carlo dose calculation with a finite size pencil-beam based intensity modulation optimization is presented. The pencil-beam algorithm is employed to compute the fluence element updates for a converging sequence of Monte Carlo dose distributions. The combination is shown to improve results over the pencil-beam based optimization in a lung tumour case and a head and neck case. Inhomogeneity effects like a broader penumbra and dose build-up regions can be compensated for by intensity modulation.

Algorithms↗

[Emergency rescue in accidents with HDR afterloading units].

PROBLEM: HDR brachyradiotherapy has minimized the exposure to radiation of the personnel working in this field. Nonetheless there are periodically reported troubles with afterloading units concerning the retraction of sources that require immediate action for the limitation of possible damage. LEGAL PRINCIPLES ACCORDING TO THE GERMAN REGULATION CONCERNING PROTECTION AGAINST RADIATION (STRAHLENSCHUTZVERORDNUNG = STRLSCHV): If in afterloading brachyradiotherapy the radiation source remains extended through malfunction we deal with an emergency according to the StrlSchV. The rescue personnel should be chosen in accordance with section 50 StrlSchV (Table 1). ORGANIZATION OF THE RESCUE OF THE PATIENT: The quickest possible rescue of a patient in an emergency demands an unequivocal definition of responsibilities. Our recommendations in this instance: the physicist is responsible for the organization of the emergency rescue. The radiation oncologist in charge informs himself about the necessary emergency measures before starting the treatment and carries out the emergency rescue. If the physicist diagnoses a failure in the retraction of the source he tries to remove the failure. If he doesn't succeed in retracting the source the radiation oncologist carries out the rescue of the patient. The organizational structure of the clinic allowing, the emergency physician should invariably be the physician who placed the applicator. In the emergency rescue the radiation oncologist should be protected by a lead barrier (Figure 1, Table 2) and use manipulators (Figure 1). DOSE ASSESSMENT IN PERSONNEL AND PATIENT: The radiation exposure of the rescue personnel is calculated from the photon-equivalence dose HX with the help of the dose-rate constant of 192Ir (Table 3). According to the same procedure there can be evaluated the local radiation exposure of the patient concerned (Table 3). CONCLUSIONS: Generally speaking, all considerations regarding the topic of emergency rescue should always start out from a worst-case scenario. Of all the people involved the patient is the one who is most exposed if the radiation source is located inside his or her body. If an emergency rescue is necessary the radiation exposure of patient and personnel can only be minimized by a quick rescue. This end requires a properly equipped emergency workplace, good training of all the people concerned, and regular exercises of the rescue procedures. A well-practiced emergency management can be of life-saving importance for the patient.

Brachytherapy↗

[Optimization of numerical measurement parameters for ECG-triggered MRI snapshot-FLASH myocardial perfusion studies].

BACKGROUND AND AIMS: In MR examinations of myocardial perfusion by the use of Snapshot-FLASH sequences it is of major importance that the achievable signal difference between pre- and normal postcontrast myocardium be maximized. METHODS: In ECG-triggered Snapshot-FLASH sequences the signal intensity of the myocardium depends on the flip angle alpha, the inversion time TI and the trigger delay TD (both depending on the cardiac frequency f) for unchanged slice thickness (SL), matrix size (MA), repetition time (TR) and echo time (TE). Therefore a simulation of the signal behavior of pre- and postcontrast myocardium based on Bloch's equations was performed by varying the flip angle alpha, TI and TD for different cardiac frequencies in order to determine an optimized combination of the measurement parameters. RESULTS: In normal heart rates (50-70 beats/min) maximal signal differences between pre- and normal postcontrast myocardium can be reached for inversion times TI = 170-200 ms and a flip angle alpha = 11 degrees. For higher heart rates again alpha = 11 degrees and TI = 200-220 ms with shortened TD (TD = 0 for f > 90 beats/min) were found to be optimal. The calculated values were semiquantitatively confirmed in phantom and volunteer measurements. CONCLUSIONS: The described method allows cardiac frequency dependent optimization of the Snapshot-FLASH measurement parameters alpha, TI and TD in order to reach a maximum in signal contrast between normal and malperfused myocardium.

Computer Graphics↗

Experimental investigation of a fast Monte Carlo photon beam dose calculation algorithm.

An experimental verification of the recently developed XVMC code, a fast Monte Carlo algorithm to calculate dose distributions of photon beams in treatment planning, is presented. The treatment head is modelled by a point source with energy distribution (primary photons) and an additional head scatter contribution. Utility software is presented, allowing the determination of the parameters for this model using a single measured depth dose curve in water. The simple beam model is considered to be a starting point for more complex models being planned for future versions of the code. This paper is mainly focused on the influence of the different techniques on variance reduction and material property determination for dose distributions. It is demonstrated that XVMC and the simple beam model reproduce measured (by a diamond detector) relative dose distributions with an accuracy of better than +/-2% in various homogeneous and inhomogeneous phantoms. Furthermore, relative dose distributions in solid state phantoms have been measured by film. Also for these cases, measured and calculated dose distributions agree within experimental uncertainty. The short calculation time (depending on voxel resolution, statistical accuracy, field size and energy, a span of 1 min to 1 h using a present-day personal computer) and an interface to a commercial planning system will allow the implementation of the code for routine treatment planning of clinical electron and photon beams.

Algorithms↗

An objective function for radiation treatment optimization based on local biological measures.

The implementation of biological optimization of radiation treatment plans is impeded by both computational and modelling problems. We derive an objective function from basic model assumptions which includes the normal tissue constraints as interior penalty functions. For organs that are composed of parallel subunits, a mean response model is proposed which leads to constraints similar to dose-volume constraints. This objective function is convex in the case when no parallel organs lie in the treatment volume. Otherwise, an argument is given to show that a number of local minima may exist which are near degenerate to the global minimum. Thus, together with the measure quality of the objective function, highly efficient gradient algorithms can be used. The number of essential biological model parameters could be reduced to a minimum. However, if the optimization constraints are given as TCP/NTCP values, Lagrange multiplier updates have to be performed by invoking comprehensive biological models.

Humans↗

A diamond detector in the dosimetry of high-energy electron and photon beams.

A diamond detector type 60003 (PTW Freiburg) was examined for the purpose of dosimetry with 4-20 MeV electron beams and 4-25 MV photon beams. Results were compared with those obtained by using a Markus chamber for electron beams and an ionization chamber for photon beams. Dose distributions were measured in a water phantom with the detector connected to a Unidos electrometer (PTW Freiburg). After a pre-irradiation of about 5 Gy the diamond detector shows a stability in response which is better than that of an ionization chamber. The current of the diamond detector was measured under variation of photon beam dose rate between 0.1 and 7 Gy min(-1). Different FSDs were chosen. Furthermore the pulse repetition frequency and the depth of the detector were changed. The electron beam dose rate was varied between 0.23 and 4.6 Gy min(-1) by changing the pulse-repetition frequency. The response shows no energy dependence within the covered photon-beam energy range. Between 4 MeV and 18 MeV electron beam energy it shows only a small energy dependence of about 2%, as expected from theory. For smaller electron energies the response increases significantly and an influence of the contact material used for the diamond detector can be surmised. A slight sublinearity of the current and dose rate was found. Detector current and dose rate are related by the expression i alpha Ddelta, where i is the detector current, D is the dose rate and delta is a correction factor of approximately 0.963. Depth-dose curves of photon beams, measured with the diamond detector, show a slight overestimation compared with measurements with the ionization chamber. This overestimation is compensated for by the above correction term. The superior spatial resolution of the diamond detector leads to minor deviations between depth-dose curves of electron beams measured with a Markus chamber and a diamond detector.

Diamond↗

Startup performance of the traveling wave versus standing wave linear accelerator.

The startup performance of medical linear accelerators is of increasing importance for modern radiotherapy techniques. The traveling wave-type linear accelerator of the SL series of Philips (now Elekta Oncology Systems) has been modified in its flight tube design to meet this goal of a fast rise time of the radiation field. The new slitless flight tube combined with a redesigned gun servo electronic now achieves start up times of the radiation comparable with those of a standing wave linear accelerator (Siemens Mevatron) according to our measurements.

Equipment Design↗

Treatment planning for bicentric stereotactic irradiation.

We have investigated a bicentric stereotactic convergent beam irradiation technique for the treatment of irregularly shaped, especially elongated, target volumes. Depending on the size and shape of the target volume optimum values for the isocenter distance, collimator apertures and dose inhomogeneity have been determined which serve as starting parameters for the interactive optimization of dose distribution. The treatment planning system of the stereotactic unit SRS-200 (Philips) has been used to calculate the parameter tables. However, the presented results are also applicable to other stereotactic systems.

Film Dosimetry↗

Quality assurance in radiotherapy: the importance of medical physics staffing levels. Recommendations from an ESTRO/EFOMP joint task group.

The safe application of ionising radiation for diagnosis and therapy requires a high level of knowledge of the underlying processes and of quality assurance. Sophisticated modern equipment can be used effectively for complicated diagnostic and therapeutic techniques only with adequate physics support. In the light of recent analyses and recommendations by national and international societies a joint working group of representatives from ESTRO (European Society for Therapeutic Radiology and Oncology) and from EFOMP (European Federation of Organisations for Medical Physics) was set up to assess the necessary staffing levels for physics support to radiotherapy. The method used to assess the staffing levels, the resulting recommendations and examples of their practical application are described.

Europe↗