A flattening filter free photon treatment concept evaluation with Monte Carlo.

In principle, the concept of flat initial radiation-dose distribution across the beam is unnecessary for intensity modulated radiation therapy. Dynamic leaf positioning during irradiation could appropriately adjust the fluence distribution of an unflattened beam that is peaked in the center and deliver the desired uniform or nonuniform dose distribution. Removing the flattening filter could lead to reduced treatment time through higher dose rates and reduced scatter, because there would be substantially less material in the beam; and possibly other dosimetric and clinical advantages. This work aims to evaluate the properties of a flattening filter free clinical accelerator and to investigate its possible advantages in clinical intensity modulated radiation therapy applications by simulating a Varian 2100-based treatment delivery system with Monte Carlo techniques. Several depth-dose curves and lateral dose distribution profiles have been created for various field sizes, with and without the flattening filter. Data computed with this model were used to evaluate the overall quality of such a system in terms of changes in dose rate, photon and electron fluence, and reduction in out-of-field stray dose from the scattered components and were compared to the corresponding data for a standard treatment head with a flattening filter. The results of the simulations of the flattening filter free system show that a substantial increase in dose rate can be achieved, which would reduce the beam on time and decrease the out-of-field dose for patients due to reduced head-leakage dose. Also close to the treatment field edge, a significant improvement in out-of-field dose could be observed for small fields, which can be attributed to the change in the photon spectra, when the flattening filter is removed from the beamline.

Journal Article↗

Monte Carlo study of backscatter in a flattening filter free clinical accelerator.

In conventional linear accelerators, the flattening filter provides a uniform lateral dose profile. In intensity modulated radiation therapy applications, however, the flatness of the photon field and hence the presence of a flattening filter, is not necessary. Removing the filter may provide some advantages, such as faster treatments and smaller out-of-field doses to the patients. In clinical accelerators the backscattered radiation dose from the collimators must be taken into account when the dose to the target volume in the patient is being determined. In the case of a conventional machine, this backscatter is known to great precision. In a flattening filter free accelerator, however, the amount of backscatter may be different. In this study we determined the backscatter contribution to the monitor chamber signal in a flattening filter free clinical accelerator (Varian Clinac 21EX) with Monte Carlo simulations. We found that with the exception of very small fields in the 18-MV photon mode, the contribution of backscattered radiation to the monitor signal did not differ from that of conventional machines with a flattening filter. Hence, a flattening filter free clinical accelerator would not necessitate a different backscatter correction.

Computer Simulation↗

Dose quantification from in-beam positron emission tomography.

Positron emission tomography (PET) imaging of the radioactivity distributions induced by therapeutic irradiation is at present the only feasible method for an in situ and non-invasive monitoring of radiooncology treatments with ion beams. The clinical implementation of this imaging technology at the experimental carbon ion therapy facility at the Gesellschaft für Schwerionenforschung (GSI) at Darmstadt, Germany is outlined and an interactive approach for a PET guided quantification of local dose deviations with respect to the treatment plan is presented.

Humans↗