PubMed Health⌕ Search

Biomedical subjects

F Peyrin

Publications and source records attributed to F Peyrin.

At least 19 recordsLinked to original sources

Intrinsic mechanical properties of trabecular calcaneus determined by finite-element models using 3D synchrotron microtomography.

To determine intrinsic mechanical properties (elastic and failure) of trabecular calcaneus bone, chosen as a good predictor of hip fracture, we looked for the influence of image's size on a numerical simulation. One cubic sample of cancellous bone (9 x 9 x 9 mm(3)) was removed from the body of the calcaneus (6 females, 6 males, 79+/-9 yr). These samples were tested under compressive loading. Before compressive testing, these samples were imaged at 10.13 microm resolution using a 3D microcomputed tomography (muCT) (ESRF, France). The muCT images were converted to finite-element models. Depending on the bone density values (BV/TV), we compared two different finite element models: a linear hexahedral and a linear beam finite element models. Apparent experimental Young's modulus (E(app)(exp)) and maximum apparent experimental compressive stress (sigma(max)(exp)) were significantly correlated with bone density obtained by Archimedes's test (E(app)(exp)=236+/-231 MPa [19-742 MPa], sigma(max)(exp)=2.61+/-1.97 MPa [0.28-5.81 MPa], r>0.80, p<0.001). Under threshold at 40 microm, the size of the numerical samples (5.18(3) and 6.68(3)mm(3)) seems to be an important parameter on the accuracy of the results. The numerical trabecular Young's modulus was widely higher (E(trabecular)(num)=34,182+/-22,830 MPa [9700-87,211 MPa]) for the larger numerical samples and high BV/TV than those found classically by other techniques (4700-15,000 MPa). For rod-like bone samples (BV/TV<12%, n=7), Young's modulus, using linear beam element (E(trabecular)(num-skeleton): 10,305+/-5500 MPa), were closer to the Young's modulus found by other techniques. Those results show the limitation of hexahedral finite elements at 40 microm, mostly used, for thin trabecular structures.

Aged↗

Engineering of bone using bone marrow stromal cells and a silicon-stabilized tricalcium phosphate bioceramic: evidence for a coupling between bone formation and scaffold resorption.

Resorbable porous ceramic constructs, based on silicon-stabilized tricalcium phosphate, were implanted in critical-size defects of sheep tibias, either alone or after seeding with bone marrow stromal cells (BMSC). Only BMSC-loaded ceramics displayed a progressive scaffold resorption, coincident with new bone deposition. To investigate the coupled mechanisms of bone formation and scaffold resorption, X-ray computed microtomography (muCT) with synchrotron radiation was performed on BMSC-seeded ceramic cubes. These were analyzed before and after implantation in immunodeficient mice for 2 or 6 months. With increasing implantation time, scaffold thickness significantly decreased while bone thickness increased. The muCT data evidenced that all scaffolds showed a uniform density distribution before implantation. Areas of different segregated densities were instead observed, in the same scaffolds, once seeded with cells and implanted in vivo. A detailed muX-ray diffraction analysis revealed that only in the contact areas between deposited bone and scaffold, the TCP component of the biomaterial decreased much faster than the HA component. This event did not occur at areas away from the bone surface, highlighting coupling and cell-dependency of the resorption and matrix deposition mechanisms. Moreover, in scaffolds implanted without cells, both the ceramic density and the TCP:HA ratio remained unchanged with respect to the pre-implantation analysis.

Animals↗

Subchondral bone micro-architectural alterations in osteoarthritis: a synchrotron micro-computed tomography study.

OBJECTIVES: We evaluated the three-dimensional (3D) micro-architecture of subchondral trabecular (Tb) bone in osteoarthritis (OA). Due to high signal-to-noise ratio and high resolution, micro-computed tomography (micro-CT) by synchrotron radiation is considered as the gold standard for bone micro-architecture imaging. DESIGN: Subchondral bone were extracted from femoral heads in OA cases in areas without cartilage (OAc-; n=6) and in adjacent areas with cartilage (OAc+; n=6) and compared to eight subchondral bone cores from osteoporosis cases (OP). The voxel size of images was 10.13 microm. We measured the bone volume fraction (BV/TV) and morphological parameters: Tb thickness (TbTh), Tb spacing (TbSp), Tb number (TbN), and bone surface/bone volume (BS/BV). The degree of anisotropy (DA), the connectivity by the Euler number and the degree of mineralization (DM) were equally assessed. RESULTS: BV/TV and morphological parameters showed significant differences between OAc- and OP samples (P<0.01 except TbTh: P<0.05) and between OAc- and OAc+ (0.05<P<0.01) but no difference between OAc+ and OP except TbN (P<0.01). The connectivity was higher in OAc- comparatively to OAc+ and OP. The DA were significantly different between OA and OP cases (P<0.01) but not between OAc- and OAc+ specimens. The DMs (mean+/-SD) were 0.817+/-0.142 g/cm(3), 0.873+/-0.161 g/cm(3), 0.906+/-0.156 g/cm(3) for OAc-, OAc+, OP (P<0.01), respectively. CONCLUSION: Subchondral bone changes were mainly observed in advanced OA, when cartilage has been deleted and preserved in adjacent area. These data suggest that subchondral bone changes would be rather secondary to the cartilage deterioration than a primitive mechanism of OA. Nevertheless, longitudinal data could bring more accurate conclusions.

Aged↗

Site-matched assessment of structural and tissue properties of cortical bone using scanning acoustic microscopy and synchrotron radiation muCT.

200 MHz scanning acoustic microscopy (SAM) and synchrotron radiation muCT (SR-muCT) were used to assess microstructural parameters and tissue properties in site-matched regions of interest in cortical bone. Anterior and postero-lateral regions of ten cross sections from human cortical radius were explored. Structural parameters, including diameter and number of Haversian canals per cortical area (Ca.Dm, N.Ca/Ar) and porosity Po were assessed with both methods using a custom-developed image fusion and analysis software. Acoustic impedance Z and degree of mineralization of bone DMB were extracted separately for osteonal and interstitial tissues from the fused images. Structural parameter estimations obtained from radiographic and acoustic images were almost identical. DMB and impedance values were in the range between 0.77 and 1.28 g cm(-3) and 5.13 and 12.1 Mrayl, respectively. Interindividual and regional variations were observed, whereas the strongest difference was found between osteonal and interstitial tissues (Z: 7.2 +/- 1.1 Mrayl versus 9.3 +/- 1.0 Mrayl, DMB: 1.06 +/- 0.07 g cm(-3) versus 1.16 +/- 0.05 g cm(-3), paired t-test, p < 0.05). Weak, but significant correlations between DMB and Z were obtained for the osteonal (R(2) = 0.174, p < 10(-4)) and for the pooled (osteonal and interstitial) data. The regression of the pooled osteonal and interstitial tissue data follows a second-order polynomial (R(2) = 0.39, p < 10(-4)). Both modalities fulfil the requirement for a simultaneous evaluation of cortical bone microstructure and material properties at the tissue level. While SAM inspection is limited to the evaluation of carefully prepared sample surfaces, SR-muCT provides volumetric information on the tissue without substantial preparation requirements. However, SAM provides a quantitative estimate of elastic properties at the tissue level that cannot be captured by SR-muCT.

Aged↗

Relationship between compressive properties of human os calcis cancellous bone and microarchitecture assessed from 2D and 3D synchrotron microtomography.

The aim of this study was to determine the contribution of 2D and 3D microarchitectural characteristics in the assessment of the mechanical strength of os calcis cancellous bone. A sample of cancellous bone was removed in a medio-lateral direction from the posterior body of calcaneus, taken at autopsy in 17 subjects aged 61-91 years. The sample was first used for the assessment of morphological parameters from 2D morphometry and 3D synchrotron microtomography (microCT) (spatial resolution=10 microm). The 2D morphometry was obtained from three slices extracted from the 3D microCT images. Very good concordance was shown between 3D microCT slices and the corresponding physical histologic slices. In 2D, the standard histomorphometric parameters, fractal dimension, mean intercept length, and connectivity were computed. In 3D, histomorphometric parameters were computed using both the 3D mean intercept length method and model-independent techniques. The 3D fractal dimension and the 3D connectivity, assessed by Euler density, were also evaluated. The cubic samples were subjected to elastic compressive tests in three orthogonal directions (X, Y, Z) close to the main natural trabecular network directions. A test was performed until collapse of trabecular network in the main direction (Z). The mechanical properties were significantly correlated to most morphological parameters resulting from 2D and 3D analysis. In 2D, the correlation between the mechanical strength and bone volume/tissue volume was not significantly improved by adding structural parameters or connectivity parameter (nodes number/tissue volume). In 3D, one architectural parameter (the trabecular thickness, Tb.Th) permitted to improve the estimation of the compressive strength from the bone volume/tissue volume alone. However, this improvement was minor since the correlation with the BV/TV alone was high (r=0.96). In conclusion, which is in agreement with the statistic's rules, we found, in this study, that the determination of the os calcis bone compressive strength using the 3D bone volume fraction cannot be improved by adding 3D architectural parameters.

Aged↗

Tissue engineering of bone: search for a better scaffold.

BACKGROUND: Large bone defects still represent a major problem in orthopedics. Traditional bone-repair treatments can be divided into two groups: the bone transport (Ilizarov technology) and the graft transplant (autologous or allogeneic bone grafts). Thus far, none of these strategies have proven to be always resolving. As an alternative, a tissue engineering approach has been proposed where osteogenic cells, bioceramic scaffolds, growth factors and physical forces concur to the bone defect repair. Different sources of osteoprogenitor cells have been suggested, bone marrow stromal cells (BMSC) being in most cases the first choice. METHODS AND RESULTS: In association with mineral tridimensional scaffolds, BMSC form a primary bone tissue which is highly vascularized and colonized by host hemopoietic marrow. The chemical composition of the scaffold is crucial for the osteoconductive properties and the resorbability of the material. In addition, scaffolds should have an internal structure permissive for vascular invasion. Porous bioceramics [hydroxyapatite (HA) and tricalcium phosphate] are osteoconductive and are particularly advantageous for bone tissue engineering application as they induce neither an immune nor an inflammatory response in the implanted host. Earlier, we first reported a cell-based tissue engineering procedure to treat three patients with long bone segmental defects. Cells were loaded on a 100% HA porous ceramic. These scaffolds proved to have good osteoconductive properties resulting in a good functional recovery, but they have not been resorbed after more than 5 years from the implant. In addition, due to the high density of the mineral and the relatively low porosity (50-60%), it was very difficult to monitor the patient recovery during the post-surgery time using X-rays. CONCLUSIONS: We report here some pre-clinical testing of new scaffolds. To compare these second generation ceramic scaffolds more suitable for a tissue engineering approach we had to first establish animal models and analysis procedures including the use of X-ray-computed microtomography associated with X-rays synchroton radiation.

Animals↗

How is the indentation modulus of bone tissue related to its macroscopic elastic response? A validation study.

This work consists of the validation of a novel approach to estimate the local anisotropic elastic constants of the bone extracellular matrix using nanoindentation. For this purpose, nanoindentation on two planes of material symmetry were analyzed and the resulting longitudinal elastic moduli compared to the moduli measured with a macroscopic tensile test. A combined lathe and tensile system was designed that allows machining and testing of cylindrical microspecimens of approximately 4mm in length and 300 microm in diameter. Three bovine specimens were tested in tension and their outer geometry and porosity assessed by synchrotron radiation microtomography. Based on the results of the traction test and the precise outer geometry, an apparent longitudinal Young's modulus was calculated. Results between 20.3 and 27.6 GPa were found that match with previously reported values for bovine compact bone. The same specimens were then characterized by nanoindentation on a transverse and longitudinal plane. A longitudinal Young's modulus for the bone matrix was then derived using the numerical scheme proposed by Swadener and Pharr and the fabric-elasticity relationship by Zysset and Curnier. Based on the matrix modulus and a power law effective volume fraction, an apparent longitudinal Young's modulus was predicted for each microspecimen. This alternative approach provided values between 19.9 and 30.0 GPa, demonstrating differences between 2% and 13% to the values provided by the initial tensile test. This study therefore raises confidence in our nanoindentation protocol of the bone extracellular matrix and supports the underlying hypotheses used to extract the anisotropic elastic constants.

Animals↗

Microarchitectural and physical changes during fetal growth in human vertebral bone.

The ossification process in human vertebra during the early stage of its formation was studied by X-ray diffraction (XRD) and X-ray microtomography (microCT) at the European Synchrotron Radiation Facility (ESRF), Grenoble, France. Twenty-two samples taken from vertebral ossification centers of human fetal bone (gestational age ranging between 16 and 26 weeks) were investigated. The analysis of three-dimensional images at high spatial resolution (approximately 10 and approximately 2 microm) allows a detailed quantitative description of bone microarchitecture. A denser trabecular network was found in fetal bone compared with that of adult bone. The images evidenced a global isotropic structure clearly composed of two regions: a central region (trabecular bone) and a peripheral region (immature bone). XRD experiments evidenced hydroxyapatite-like crystalline structure in the mineral phase at any fetal age after 16 weeks. Interestingly, the analysis of XRD patterns highlighted the evolution of crystalline structure of mineralized bone as a function of age involving the growth of the hydroxyapatite crystallites.

Adult↗

Ultrasonic characterization of human cancellous bone using transmission and backscatter measurements: relationships to density and microstructure.

The present study was designed to evaluate the relationships between ultrasonic backscatter, density, and microarchitecture of cancellous bone. The slopes of the frequency-dependent attenuation coefficient (nBUA), ultrasound bone velocity (UBV), the frequency-averaged backscatter coefficient (BUB) were measured in 25 cylindrical cancellous bone cores. Bone mineral density (BMD) was determined using X-ray quantitative computed tomography. Microarchitecture was investigated with synchrotron radiation microtomography with an isotropic spatial resolution of 10 microm. Several microstructural parameters reflecting morphology, connectivity, and anisotropy of the specimens were derived from the reconstructed three-dimensional (3D) microarchitecture. The association of the ultrasonic variables with density and microarchitecture was assessed using simple and multivariate linear regression techniques. For all ultrasonic variables, a strong association was found with density (r = 0.84-0.90). We also found that, with the exception of connectivity, all microstructural parameters correlated significantly with density, with r values of 0.54-0.92. For most microstructural parameters there was a highly significant correlation with ultrasonic parameters (r = 0.33-0.91). However, the additional variance explained by microstructural parameters compared with the variance explained by BMD alone was small (Delta r(2) = 6% at best). In particular, no significant independent association was found between microstructure and backscatter coefficient (a microstructure-related ultrasonic parameter) after adjustment for density. The source for the unaccounted variance of quantitative ultrasound (QUS) parameters remains unknown.

Aged↗

Synchrotron radiation microtomography allows the analysis of three-dimensional microarchitecture and degree of mineralization of human iliac crest biopsy specimens: effects of etidronate treatment.

Quantitative microcomputed tomography using synchrotron radiation (SR microCT) was used to assess the effects of a sequential etidronate therapy on both three-dimensional (3D) microarchitecture and degree of mineralization of bone (DMB) in postmenopausal osteoporosis. Thirty-two iliac crest biopsy specimens were taken from 14 patients with osteoporosis (aged 64 +/- 1.8 years) before (baseline) and after 1 year of etidronate treatment, and after 2 years of treatment for four of the patients. The samples were imaged at high spatial resolution (voxel size = 10 microm) using the microtomography system developed at the European Synchrotron Radiation Facility (ESRF), Grenoble, France. Three-dimensional microarchitecture parameters were calculated and compared with those obtained from conventional histomorphometry. In addition, the DMB was evaluated also in 3D. No significant statistical changes regarding bone mass and structural parameters were observed in histomorphometry or 3D analyses. The distribution of the DMB in cortical and trabecular bone showed a trend to a shift toward highest mineralization values after 1 year of etidronate treatment (3.88% and 1.24% in cortical and trabecular bone, respectively). This trend was more evident after 2 years. The study also showed that SR microCT is an accurate technique and the only one for quantifying both the mineralization and the microarchitecture of bone samples at the same time in 3D.

Aged↗

Frequency dependence of ultrasonic backscattering in cancellous bone: autocorrelation model and experimental results.

The goal of this study is to model the frequency dependence of the ultrasonic backscatter coefficient in cancellous bone. A twofold theoretical approach has been adopted: the analytical theoretical model of Faran for spherical and cylindrical elastic scatterers, and the scattering model for weakly scattering medium in which the backscatter coefficient is related to the autocorrelation function of the propagating medium. The ultrasonic backscatter coefficient was measured in 19 bone specimens (human calcaneae) in the frequency range of 0.4-1.2 MHz. The autocorrelation function was computed from the three-dimensional (3D) microarchitecture measured using synchrotron radiation microtomography. Good agreement was found between the frequency dependence of the experimental (f3.38+/-0.31) and autocorrelation modeled (f3.48+/-0.26) backscatter coefficients. The results based on Faran theory (cylindrical Faran model: f2.89+/-0.06 and spherical Faran model: f3.91+/-0.04) show qualitative agreement with experimental data. The good prediction obtained by modeling the backscatter coefficient using the autocorrelation function of the medium opens interesting prospects for the investigation of the influence of bone microarchitecture on ultrasonic scattering.

Aged↗

Perspectives in three-dimensional analysis of bone samples using synchrotron radiation microtomography.

In this paper we present a methodology based on 3D synchrotron radiation microtomography to analyze non-destructively 3D bone samples. After a technical presentation of the imaging system and the image analysis techniques, we report results on three-dimensional analysis of vertebral samples from women of different ages. The new capabilities of this technique for the investigation of bone are discussed. They include a high spatial resolution down to the micron level, a high density resolution allowing a local quantification of bone mineralization, phase contrast imaging and advances in 3D image analysis.

Adult↗

A synchrotron radiation microtomography system for the analysis of trabecular bone samples.

X-ray computed microtomography is particularly well suited for studying trabecular bone architecture, which requires three-dimensional (3-D) images with high spatial resolution. For this purpose, we describe a three-dimensional computed microtomography (microCT) system using synchrotron radiation, developed at ESRF. Since synchrotron radiation provides a monochromatic and high photon flux x-ray beam, it allows high resolution and a high signal-to-noise ratio imaging. The principle of the system is based on truly three-dimensional parallel tomographic acquisition. It uses a two-dimensional (2-D) CCD-based detector to record 2-D radiographs of the transmitted beam through the sample under different angles of view. The 3-D tomographic reconstruction, performed by an exact 3-D filtered backprojection algorithm, yields 3-D images with cubic voxels. The spatial resolution of the detector was experimentally measured. For the application to bone investigation, the voxel size was set to 6.65 microm, and the experimental spatial resolution was found to be 11 microm. The reconstructed linear attenuation coefficient was calibrated from hydroxyapatite phantoms. Image processing tools are being developed to extract structural parameters quantifying trabecular bone architecture from the 3-D microCT images. First results on human trabecular bone samples are presented.

Aged↗

Micro-CT examinations of trabecular bone samples at different resolutions: 14, 7 and 2 micron level.

Tomographic techniques are attractive for the investigation of trabecular bone architecture. Using either conventional X-ray sources or synchrotron sources currently allows the acquisition of 3D images in a wide range of spatial resolution that may be as small as a few micrometers. Since it is technically possible to examine trabecular architecture at different scales, a question is to know what type of information it is possible to get at each scale. For this purpose, a series of ten vertebrae samples from healthy females of different ages (33 to 90) was imaged at various resolutions on three different micro-CT systems (cubic voxel size respectively 14, 6.7 and 1.4 microm). The comparison of morphometric parameters extracted from the different images is in agreement with simulation results on the influence of spatial resolution on structure parameters. The conclusion is that a 14 microm voxel size gives a reasonably good parameterisation of trabecular architecture. Besides the synchrotron radiation 2 microm level images reveal interesting features on the irregularities and rupture of trabecular surface, and on remodeling zones.

Adult↗

Binary vascular reconstruction from a limited number of cone beam projections.

This paper describes a method to perform reconstruction of vascular cross-sectional images from a limited number of x-ray angiographic cone-beam projections. It is assumed that the projection data can be simplified by identifying blood vessels in each angiogram and removing signals due to other structures. Under these conditions, the x-ray attenuation coefficient, mu, can be modeled as a binary variable having a value mu 0 within the vessel and "0" outside. The reconstruction is performed by minimizing a cost function using the method of simulated annealing. In this paper, we demonstrate that the introduction of a priori information allows one to reconstruct a sphere and a simulated branched vessel from three views with, respectively, 97% and 93% of voxels having correct values. The addition of a continuity constraint for the reconstruction of the branched vessel resulted in further reduction in the percentage of misplaced voxels. Calculations require from one to six hours of CPU time on a Sun SparcStation 2 computer for the cases investigated here. The effect of noise, "cooling" schedule, and number of views on the reconstruction are examined using simulated vessel projections. Modifications to our approach to accelerate the reconstruction are also discussed.

Angiography↗

3D display of high resolution vertebral structure images.

In this paper we present a methodology for three-dimensional representation of vertebral structures. A set of X-ray CT images is obtained on a specific high resolution acquisition system. The images are then segmented in order to separate trabecular and cortical structures. Finally, the complex 3D surfaces are visualized using a volume rendering technique.

Humans↗