PubMed Health⌕ Search

Biomedical subjects

F Pilleul

Publications and source records attributed to F Pilleul.

At least 19 recordsLinked to original sources

[Von Meyenburg disease found during laparoscopic surgery: report of two cases].

The authors report two cases of von Meyenburg complexes disease found during laparoscopic surgical procedures. The first patient (41 years old) had multiple gallbladder stones with recurrent hepatic colics. The second patient (45 years old) had gastroesophageal reflux with recurrent peptic esophagitis. In both cases, multiple millimetric and superficial hepatic lesions were found during the exploration of the abdominal cavity. Then, an hepatic biopsy was done because the macroscopic aspect should suspect secondary metastatic lesions. Histological result made the diagnosis of von Meyenburg complexes disease (biliary microhamartomas). It seems to be important to know this anomaly of the ductal plate development and to do a liver biopsy during laparoscopy to affirm the diagnosis and cancel the diagnosis of multiple hepatic metastasis. In fact, this congenital pathology could be associated with increased risk of cholangiocarcinoma of the liver. The modality of radiological monitoring still remains to be defined.

Adult↗

[Magnetic resonance angiography of splanchnic artery aneurysms and pseudoaneurysms].

PURPOSE: To correlate Magnetic resonance angiography (MRA) with computed tomography for the diagnosis of splanchnic artery aneurysms. MATERIALS-METHODS: We retrospectively reviewed the MRA findings of splanchnic arteries performed in 16 patients with known splanchnic aneurysms. Sixteen patients underwent computed tomography (CT), and MRA. Conventional angiogram was performed to confirm the diagnosis in six cases. This study was conducted on a 1.5T MR Symphony system (Siemens, Erlangen, Germany). CE-MRA was performed by using a 3D RF-spoiled FLASH sequence. Acquisition of source images was performed in the coronal plane and reconstructed by means of maximum-intensity projection (MIP) post-processing. RESULTS: Patient population included 7 men and 9 women aged from 31 to 85 years old (mean age 59.5 years old). Splanchnic aneurysms were located as follows: splenic (n=5), hepatic (n=6), celiac trunk (n=4) and gastroduodenal (n=1). In 9 cases, MRA provided results similar to CT. In 3 cases, MRA provided more accurate information on the location of the aneurysm or detected additional aneurysms. In 4 patients, a diagnosis of aneurysm was made first or only made on MRA. CONCLUSION: This small series showed a good correlation between CT and MRA for detection and characterization of splanchnic aneurysms.

Adult↗

[Asymptomatic or paucisymptomatic CBD dilatation on US after cholecystectomy: management].

In western countries, 10-15% of the population has gallbladder stones with 46,000 cholecystectomies performed in France in 2003. So, daily ultrasonography of the abdomen performed in patients without gallbladder is a routine exam. However, identification of an enlarged common bile duct is frequent and the normal nature of this finding remains uncertain. The purpose of this article is to perform a literature review of the impact of cholecystectomy on the diameter of the common bile duct. Furthermore, it is important not to dismiss common bile duct dilatation after cholecystectomy because it may be the result of post operative complication or secondary to a congenital disease of bile duct.

Adult↗

[Out of phase magnetic resonance imaging and liver applications].

The increasing indications for MRI evaluation of diseases of the abdomen, especially liver tumors, has promoted the development of sequences allowing further histological characterization. Out of phase sequences provide suppression of lipids and water signal at the cellular level. Available on all MR imagers, it is the most sensitive sequence to depict small amounts of lipids in the liver. Best applications of this sequence include liver steatosis, tumoral characterization with regards to lipid content (adenoma, hepatocellular carcinoma...) and depiction of tumors in abnormal liver. Performed without contrast injection, and using fast imaging acquisition, we believe that out of phase imaging should be performed for magnetic resonance imaging of the liver.

Fatty Liver↗

[Value of contrast-enhanced MR enterography in pediatric Crohn's disease: preliminary study].

OBJECTIVE: Feasibility study of contrast enhanced MR enterography without enteroclysis as a new diagnostic tool for children with known or suspected Crohn's disease. METHODS: We prospectively included 15 children, 8-18 years old, with clinical suspicion of Crohn's disease. MR enterography without enteroclysis was performed on a 1,5 T clinical MR system. A total of 1000 ml of mannitol 5% was orally administered 60 minutes prior to MRI. Coronal and axial breath-hold sequences were acquired. The following sequences were obtained: True-FISP, FLASH T1 2D/3D with Fat saturation before and after gadolinium injection. Two radiologists, blinded to patient information, independently reviewed all examinations to record image quality, the degree of distension of the distal ileum, the presence of abnormal bowel segments and the presence of extra-intestinal complications. MRI findings were correlated to sonographic, endoscopic and biological results (sensitivity, specificity, Kappa test). RESULTS: The examinations were considered of satisfactory diagnostic quality in 93.3% of patients. Respiratory artifacts were present in one case. The entire GI tract could be identified on all sequences. Distention of the distal ileum was recorded as good to excellent in 89% of healthy subjects. Five MR examinations were considered abnormal with isolated ileal involvement in 2 cases, ileocolic involvement in 2 cases, and isolated colonic involvement in 1 case. The sensitivity and specificity of MR for the positive diagnosis of Crohn's disease were 100% and 83% respectively. Three extra-intestinal complications were detected: one case of ileo-ileal fistula, not identified on ultrasonography, an asymptomatic anal fistula and a symptomatic inflammatory stricture. CONCLUSION: MR enterography without enteroclysis is a well tolerated, effective non invasive method in the evaluation of known or suspected Crohn's disease. Because of the absence of ionizing radiation, MR enterography should become the gold standard in pediatric patients.

Administration, Oral↗

Pneumatocele formation in adult Escherichia coli pneumonia revealed by pneumothorax.

Pulmonary pneumatoceles are a rare complication of nosocomial pneumonia. They occur most often in staphylococcal infections and are hence more frequent in children. We report the case of an immunocompromised adult who shortly after digestive surgery developed Escherichia coli pneumonia which evolved rapidly towards pneumatocele formation revealed by pneumothorax.

Cross Infection↗

In vivo colon wall imaging using endoluminal coils: feasibility study on rabbits.

PURPOSE: To assess in vivo distal colon wall magnetic resonance imaging (MRI) feasibility on rabbits using an endoluminal radio frequency (RF) coil on a 1.5-T clinical scanner. MATERIALS AND METHODS: The endoluminal coil signal-to-noise ratio (SNR) was compared to a clinical four-element phased-array body coil. High-resolution (HR) MRI of rabbit colon walls was performed on six rabbits. The imaging protocol combined T1-weighted fast low-angle-shot (FLASH) sequences with and without fat saturation (FS), T2-weighted True-Fast imaging with steady state precession (Fisp), turbo spin-echo (TSE), and T1-weighted FLASH FS after contrast media injection. Images were compared to histological sections. Catheter tracking using an endoluminal coil in addition to external coils was also evaluated on two rabbits. RESULTS: HR images allow visualization and identification of rabbit colon wall layers. Real-time tracking allows a clear visualization and a good positioning of the endoluminal coil within the rabbit. CONCLUSION: Compared to a clinical multielement array coil, a dedicated endoluminal RF coil provides an important SNR increase at the region of interest (ROI). Very HR images of in vivo rabbit colon walls were achieved providing detailed information on the different wall layers. This technique could be considered on humans for accurate tumoral and inflammatory bowel disease diagnosis.

Animals↗

[Abdominal wound injuries: diagnosis and treatment. Report of 79 cases].

INTRODUCTION: - Traditionally, penetrating abdominal wounds justify routine laparotomy. However, this policy can be adapted to mechanism of injury (stab or firearm) and accuracy of imaging procedures if they eliminate visceral injury thus allowing close follow up. PATIENTS AND METHODS: Retrospective study of 79 patients (May 1995-May 2002) with a penetrating abdominal wound: (47 (59%) stab wounds and 32 (41 %) firearm wounds). Correlation between imaging and surgical findings, treatment, post-operative course were studied. RESULTS: Sixty-eight patients were operated on from the outset, and 11 underwent close follow-up. Of the 11 patients who had follow-up, (9 after stab wound and 2 after firearm wound), two had to be operated (1 in each group). Correlation between imaging and surgical findings was good in 34 (72%) patients after stab wound and in 21 (80%) after firearm wound; the mean number of visceral injuries was 1 and 3 respectively. Six patients (8%) died (mortality: 2% and 16% respectively), 12 (15%) had postoperative complications. CONCLUSION: Penetrating abdominal stab wounds can be treated by close follow-up if imaging excludes visceral injury. Firearm wounds still justify routine laparotomy due to both multiplicity of visceral injuries and bad prognosis.

Abdominal Injuries↗

[Etiology of biliary stenosis at MR Cholangiography: correlation with pathology findings].

OBJECTIVE: To evaluate the accuracy of MR cholangiography to differentiate between the benign and malignant etiology of biliary strictures, excluding bilioenteric anastomoses. MATERIALS AND METHODS: 49 patients (26 males, 23 females) with suspected biliary stricture underwent MR cholangiography at 1.5T (Siemens Symphony). RARE and HASTE sequences were acquired in the coronal, oblique and axial planes. MR cholangiography findings were reviewed by two independent radiologists and correlated with the final histological diagnosis. Sensitivity, specificity, and agreement were calculated with a 95% confidence interval. RESULTS: Benign stenosis was identified in 23 patients (47%) and malignant stenosis in 26 (53%). The sensitivity of MR cholangiography was 64% and the specificity was 96%. The agreement between results at MR cholangiography and histology was moderate. The inter-observer agreement for MR cholangiography was good with a Kappa value of 0.61. CONCLUSION: MR cholangiography has the potential to replace diagnostic cholangiography in patients with suspected biliary stricture. Direct cholangiography could be reserved for patients where a therapeutic procedure is anticipated.

Adenocarcinoma↗

[Detection of liver metastases in colorectal cancer on chemotherapy. Comparative study between MRI with teslascan and computed tomography with intravenous contrast media].

OBJECTIVE: To compare MRI of the liver with mangafodipir trisodium (MnDPDP) and computed tomography with intravenous contrast media in the follow-up of liver metastases in patient on chemotherapy for colorectal carcinoma. MATERIALS AND METHODS: This was a prospective study with patients on chemotherapy for liver metastases from colorectal cancer. Patients underwent both contrast-enhanced helical CT using 2 cc/kg contrast at 3 cc/sec and mangafodipir trisodium-enhanced MR imaging at 1.5 T using 2-3 cc/min contrast at 5 micro mol/kg within a two week interval. Two experienced radiologists independently reviewed all scans in a blinded fashion and recorded image quality as well as presence and number of liver lesions. Statistical analysis was performed using the wilcoxon signed rank test. RESULTS: All examinations were of good quality. A total of 71 lesions were detected at CT, with 69 lesions consistent with metastases and 2 lesions consistent with cysts. A total of 98 lesions were detected at MRI, with 97 consistent with metastases and 1 lesion consistent with a cyst. T1 weighted images with MnDPDP significantly detected two additional lesions compared to CT (p<0.05). No significant difference was demonstrated between T1 weighted images without MnDPDP and CT or between T2 weighted images and CT. CONCLUSION: Magnetic resonance imaging with MnDPDP is significantly more sensitive than unenhanced MRI and helical CT for the follow-up of liver lesions.

Aged↗

[Cross sectional imaging evaluation of the small bowel].

Recent advances of cross sectional imaging allow optimal evaluation of the small bowel. This chapter will detail technical considerations and emphasize the role of imaging in the evaluation of the most common diseases of the small bowel.

Crohn Disease↗

[Ultrasound imaging of focal liver lesions with contrast agents: which clinical applications?].

The contrast-enhanced ultrasonography is a promising technique for the diagnosis of focal liver lesion with an increased sensitivity for the tumour detection and a direct visualization of the tumour vascularity. The future applications of this technique will probably depend on the clinical context: in case of suspicion of benign tumour, contrast injection should be able to facilitate the characterization of hemangiomas and focal nodular hyperplasia, when hepatic metastases are researched, it may improve the detection of small lesions in cirrhotic patients, it may facilitate the detection of small hepatocellular carcinomas and find a place in the systematic screening for these tumours. The recently published data are encouraging, but a confirmation of the clinical interest of this technique, and its place within the imaging diagnostic strategies still have to be performed.

Carcinoma, Hepatocellular↗

[MRI of the GI tract: technical considerations and future applications].

Barium enema remains the reference method for the detection of morphological intraluminal alterations of the bowel. Optimal filling of intestinal loops allows high diagnostic sensitivity and specificity. US, CT and MRI are useful diagnostic procedures in the evaluation of mural and extramural alterations. In recent years, MR-enteroclysis and MR colonography have been developed, both enable the evaluation of luminal, extraluminal and mural alterations of the bowel. While these modalities provide good imaging evaluation of the bowel, visualization of the different layers, as seen on US, is still not available. Use of high resolution endoluminal coil on MR could improve mural evaluation of bowel to differentiate inflammatory diseases and provide accurate TNM classification of tumoral lesion with minimally invasive procedure.

Humans↗

Diagnosis of splanchnic artery aneurysms and pseudoaneurysms, with special reference to contrast enhanced 3D magnetic resonance angiography: a review.

Splanchnic artery aneurysms are rare. In the past, conventional angiography was the only way to detect them, but today non-invasive techniques are available. Breath-hold contrast-enhanced 3D magnetic resonance angiography has become a routine examination for evaluation of the aorta and its visceral branches. In this article, we briefly discuss the technical aspects of 3D contrast-enhanced magnetic resonance angiography and illustrate various splanchnic artery aneurysms-pseudoaneurysms with their main characteristics.

Aneurysm↗

Diagnostic ERCP.

Explore the source record for details and available documents.

Biliary Tract Diseases↗

[Mechanical small bowel obstruction due to bezoars: correlation between CT and surgical findings].

PURPOSE: To evaluate the correlation between computed tomography (CT) and surgery, for the diagnosis of bezoar in small bowel obstruction. To analyze the predisposing etiologic factors in this population. PATIENTS AND METHODS: We reviewed retrospectively between 1994 and 1999, 12 patients whose final diagnosis was small bowel obstruction with bezoar. All patients underwent helical CT scan before treatment. Eight patients were treated by surgery and 4 recovered with gastric aspiration. RESULTS: Small bowel obstruction was diagnosed by CT which always demonstrated a transition zone with ovoid intraluminal mass outlined by the bowel wall. The mass consisted of a mixture of soft tissue and internal gas bubbles like feces, suggesting bezoar. Surgery confirmed small bowel obstruction and presence of bezoar. Predisposing factors were: partial gastrectomy (2/12), post surgical adhesions (7/12), Meckel diverticulum (1/12) and dietary factors. CONCLUSION: We agree with the authors of the few prior CT reports and suggest that the characteristic CT appearance of mottled gas pattern is pathognomonic of bezoar with an excellent correlation in our population.

Adult↗