PubMed Health⌕ Search

Biomedical subjects

F Raymond

Publications and source records attributed to F Raymond.

At least 19 recordsLinked to original sources

[Haematological complications of prostatic cancer: 2 cases, one revealing the neoplasia].

INTRODUCTION: We report two cases of patients with prostate cancer who underwent haematological complications from the disease. CLINICAL CASES: Diffuse intravascular coagulopathy (with thrombopenia) was observed in two patients (55 and 59 years-old) diagnosed with prostate cancer. In one patient who had normal prostate at clinical examination, thrombopenia with incomplete diffuse intravascular coagulopathy and biological inflammatory led to diagnosis. It was initially controlled by hormonal therapy and secondary by chemotherapy. In the other patient diffuse intravascular coagulopathy followed introduction of hormonal therapy and lead to the patient's death. DISCUSSION: Patients with metastatic hormone-refractory prostate carcinoma may have life-threatening coagulation complications due to their disease. Diffuse intravascular coagulopathy is the most frequent coagulation complication. Other coagulopathies associated with prostate cancer are thrombocytopenic thrombotic purpura, thrombosis, Trousseau's syndrome and acquired factor VIII inhibitor development. Usually these haematological manifestations complicate the course of the disease and appear to have a bad prognosis. But thrombopenia or haematologic features may lead to the diagnosis of medullary metastatic prostatic cancer, even if the prostate appears normal at the initial clinical examination.

Adenocarcinoma↗

The development of a high-density canine microarray.

DNA microarrays can give global transcriptional views of cellular responses to disease, development, nutrition, and other biological states. They can be used to elucidate biological networks, develop diagnostics, and identify genetic targets and molecular mechanisms. The technology is widely used and can be a valuable complement to more "disease-centric" focused arrays. For these reasons, Nestlé designed a custom canine Affymetrix microarray representing transcripts from multiple tissues for use in areas where a more focused microarray had not already been developed. Sufficient numbers of sequences representing messenger RNAs (mRNAs) or expressed sequence tags (ESTs) is integral for the design of a global microarray chip. This chip was designed using public domain sequences (GenBank) and sequences from a proprietary canine EST database. In order to enrich the chip with annotated transcripts, both of these sequence sets were BLASTed against the nonredundant protein database. The sequences on the microarray were isolated from more than 48 different tissues. The final compliment of sequences had sequences unique to GenBank (3160), unique to the proprietary EST database (17,620), and present in both sources (1996). In comparison with human sequences (RefSeq), 74% of the canine sequences matched a human sequence.

Animals↗

Fibroblast growth factor-18 is a trophic factor for mature chondrocytes and their progenitors.

OBJECTIVE: The aim of this study was to examine the effects of recombinant human Fgf18 on chondrocyte proliferation and matrix production in vivo and in vitro. In addition, the expressions of Fgf18 and Fgf receptors (Fgfr) in adult human articular cartilage were examined. METHODS: Adenovirus-mediated transfer of Fgf18 into murine pinnae and addition of FGF18 to primary cultures of adult articular chondrocytes were used to assess the effects of FGF18 on chondrocytes. In situ hybridization was used to examine the expression of Fgf18 and Fgfr s in adult human articular cartilage. RESULTS: Expression of Fgf18 by adenovirus-mediated gene transfer in murine pinnae resulted in a significant increase in chondrocyte number. Chondrocytes were identified by staining with toluidine blue and a monoclonal antibody directed against type II collagen. Fgf18, Fgfr 2-(IIIc), Fgfr 3-(IIIc), and Fgfr 4 mRNAs were detected within these cells by in situ hybridization. The nuclei of the chondrocytes stained with antibodies to PCNA and FGF receptor (FGFR) 2. Addition of FGF18 to the culture media of primary articular chondrocytes increased the proliferation of these cells and increased their production of extracellular matrix. To assess the receptor selectivity of FGF18, BaF3 cells stably expressing the genes for the major splice variants of Fgfr1-3 were used. Proliferation of cells expressing Fgfr 3-(IIIc) or Fgfr 2-(IIIc) was increased by incubation with FGF18. Using FGFR-Fc fusion proteins and BaF3 cells expressing Fgfr 3-(IIIc), only FGFR 3-(IIIc)-Fc, FGFR 2-(IIIc)-Fc or FGFR 4-Fc reduced FGF18-mediated cell proliferation. Expression of Fgf18, Fgfr 3-(IIIc) and Fgfr 2-(IIIc) mRNAs was localized to chondrocytes of human articular cartilage by in situ hybridization. CONCLUSION: These data demonstrate that Fgf18 can act as a trophic factor for elastic chondrocytes and their progenitors in vivo and articular chondrocytes cultured in vitro. Expression of Fgf18 and the genes for two of its receptors in chondrocytes suggests that Fgf18 may play an autocrine role in the biology of normal articular cartilage.

Adult↗

Monitoring gastrointestinal intraluminal PCO2: problems with airflow methods.

UNLABELLED: Gastrointestinal intraluminal PCO2 (PiCO2) information is used to assess the adequacy of trauma patient resuscitation and to assist in choosing resuscitative interventions. Therefore, determining the limitations and potential caveats of different PiCO2 monitoring systems is clinically important. This study compared two PCO2 monitoring systems. The airflow device adds and then removes air samples to quantitate PCO2, whereas the fiber-optic device does not. METHODS: Airflow (TRIP Tonometer/Tonocap) and fiber-optic (Neotrend) systems were used. In vitro they were compared with each other and to two end-tidal CO2 monitors measuring the PCO2 of humidified air containing 5% and then 10% CO2. In vivo the two systems' catheters were surgically juxtaposed in 15 dogs' stomachs; paired PiCO2 readings were taken throughout hemorrhage and resuscitation. RESULTS: In vitro, paired PCO2 values from the airflow and fiber-optic devices correlated with each other (r = 0.99) and with end-tidal values (r = 0.99 with airflow, r = 0.95 with fiber-optic). In vivo, paired values differed significantly (P < 0.0001), correlating poorly for two devices simultaneously measuring the same variable (r = 0.61). Fiber-optic PiCO2 values were higher than airflow values (mmHg +/- SEM): 69.3 +/- 4.8 vs. 61.3 +/- 5.6 at the start of hemorrhage, 141.3 +/- 12.9 vs. 87.7 +/- 7.9 by end of hemorrhage, and 104.3 +/- 9.6 vs. 82.8 +/- 7.0 by end of resuscitation for fiber-optic and airflow, respectively. CONCLUSIONS: Despite agreement in vitro, airflow methods can influence PiCO2 values obtained in vivo. Passive sensing methods used to monitor PiCO2, such as fiber-optic methods, are preferable because they neither deliver O2 to, nor remove CO2 from the local microenvironment.

Animals↗

Steady-state end-tidal alveolar dead space fraction and D-dimer: bedside tests to exclude pulmonary embolism.

STUDY OBJECTIVE: Less than 35% of patients suspected of having pulmonary embolism (PE) actually have PE. Safe bedside methods to exclude PE could save health-care resources and improve access to diagnostic testing for suspected PE. In patients with suspected PE, we sought to determine the sensitivity, specificity, and negative predictive value of (1) a steady-state end-tidal alveolar dead space fraction (AVDSf) of < 0.15, (2) a negative D-dimer result, and (3) the combination of a steady-state end-tidal AVDSf of < 0.15 and a negative D-dimer result. STUDY DESIGN: Prospective cohort study. SETTING: Tertiary-care center in Ottawa, Ontario, Canada. PATIENTS: Consecutive inpatients, outpatients, and emergency department patients with suspected PE referred to the Departments of Nuclear Medicine or Radiology for investigation of suspected PE. INTERVENTIONS AND MEASUREMENTS: All study patients had D-Dimer and alveolar dead space measurements prior to determining outcome (PE or no PE) with ventilation/perfusion scans and/or noninvasive leg vein imaging and/or pulmonary angiography. RESULTS: Two hundred forty-six eligible and consenting patients underwent diagnostic imaging that excluded PE in 163 patients, diagnosed PE in 49 patients, and was indeterminant in 34 patients. A negative D-dimer result excluded PE with a sensitivity of 83.0% (95% confidence interval [CI], 69.2 to 92.4%), a negative predictive value of 91.2% (95% CI, 83.4 to 96.1%), and a specificity of 57.6%. A steady-state end-tidal AVDSf of < 0.15 excluded PE with a sensitivity of 79.5% (95% CI, 63.5 to 90.7%), a negative predictive value of 90.7% (95% CI, 82.5 to 95.9%), and a specificity of 70.3%. The combination of a negative D-dimer result and a steady-state end-tidal AVDSf of < 0.15 excluded PE with a sensitivity of 97.8% (95% CI, 88.5 to 99.9%), a negative predictive value of 98.0% (95% CI, 89.4 to 99.9%), and a specificity of 38.0%. CONCLUSION: This simple combination of bedside tests may safely rule out PE without further diagnostic testing in large numbers of patients with suspected PE.

Diagnosis, Differential↗

Diagnostic value of arterial blood gas measurement in suspected pulmonary embolism.

Pulmonary embolism (PE) is a common and lethal yet treatable condition. Several authors have reported on the diagnostic value of combinations of arterial blood gas (ABG) and other clinical data (i. e., prediction rules), and have claimed that these combinations can be safely used to exclude PE. The purpose of this investigation was to evaluate the diagnostic value of ABG measurement and to attempt to validate the ABG prediction rules published by these various authors for the assessment of patients with suspected PE. Two hundred ninety-three consecutive patients referred for imaging to investigate suspected PE were approached to participate in the investigation. ABG and other clinical data were obtained from consenting and eligible patients before an outcome classification (PE versus non-PE) was performed. None of the ABG data or prediction rules had sufficient negative predictive value, specificity, or likelihood ratios to be useful in the management of patients with suspected PE. We conclude that ABG data alone or in combination with other clinical data are not useful in the assessment of suspected PE.

Arteries↗

Purification of a recombinant protein expressed in yeast: optimization of analytical and preparative chromatography.

The industrial production of recombinant proteins requires control of both fermentation and purification steps. For the serodiagnosis of toxoplasmosis, the main antigen is a membrane protein of 30 kDa (P30). The P30 gene was cloned and expressed in Schizosaccharomyces pombe at 0.7 microg/ml in culture medium. Batch fermentation was optimized by the specific choice of peptones, which enabled optimum growth and protein expression without reducing the efficacy of the purification step. Analytical purification was then carried out using cation-exchange chromatography. For larger volumes, scaling up was performed on expanded mode by using a Streamline system (Pharmacia). This purification step allowed us to obtain a 67.5% recovery with a purification factor greater than 27-fold. Expanded bed adsorption technology is a convenient and effective technique for protein capture directly from feedstock, and the eluted fraction is ready for a second affinity chromatography step. This second step is performed with a yield of 40% and provides a final purification factor of 2000-fold.

Adsorption↗

Nailbed injuries with hallucal phalangeal fractures--evaluation and treatment.

Adequate assessment of crush injuries to the hallux is necessary before appropriate management can be initiated. When distal phalangeal fractures of the hallux are detected by routine radiography and subungual hematomas are present, open fractures of the hallux may be overlooked if the physician does not routinely avulse the nailplate. The authors review current modalities for the detection and evaluation of these injuries and present a protocol for treatment.

Anti-Bacterial Agents↗

The use of Vicryl mesh (polyglactin 910) for implantation of hydroxyapatite orbital implants.

Hydroxyapatite (HA) implants currently are most commonly wrapped in donor sclera before implantation to facilitate placement within the orbit and allow attachment of the extraocular muscles. Although the risk of acquiring a transmittable disease through donor sclera is extremely low, some individuals remain concerned about receiving nonautologous material. As an alternative to sclera, autologous temporalis fascia, or autologous fascia lata, we have been wrapping HA in "Vicryl mesh" before insertion into the orbit. The Vicryl mesh-wrapped implant goes into the socket readily, allows one to easily attach the extraocular muscles, and has no risk of transmittable disease. In addition, the Vicryl mesh is readily available at most hospitals and is dissolvable.

Durapatite↗

Evaluation of renal function in 60 long-term survivors of bone marrow transplantation.

Although the acute nephrotoxicity of bone marrow transplantation is well documented, long-term follow-up studies are scanty. Renal function was evaluated in 60 long-term survivors of allogeneic (24 patients) or autologous (36 patients) bone marrow transplantation (BMT) with a mean follow-up of 2 yr. Renal function tests included serum creatinine, GFR (inulin clearance), effective RPF (p-aminohyppurate clearance), urinary beta 2-microglobulin and N-acetyl-beta-D-glucosaminidase excretion, and renal tomography. The mean serum creatinine level was 83 +/- 3 and 93 +/- 3 mumol/L before and after grafting, respectively (P < 0.05). The mean GFR (93 +/- 3 mL/min) and effective RPF (419 +/- 16 mL/min) were significantly lower than in healthy controls (120 +/- 3 and 500 +/- 1 mL/min; P < 0.05) and than in candidates for BMT matched for age and hematologic diseases (117 +/- 3 and 469 +/- 11 mL/min; P < 0.05). Thirty-four patients had a fall in the GFR of at least 20%. Patients who received total body irradiation had significant lower creatinine clearance (86 +/- 3 mL/min) and GFR (86 +/- 3 mL/min) than the controls and the patients who received high-dose chemotherapy (100 +/- 4 and 104 +/- 5 mL/min; P < 0.05). These results suggest that subclinical renal dysfunction occurs frequently in marrow graft recipients, especially those who undergo total body irradiation.

Adult↗

Vicryl-mesh wrap for the implantation of hydroxyapatite orbital implants: an animal model.

OBJECTIVE: To evaluate host fibrovascularization of hydroxyapatite orbital implants wrapped in sclera or in Vicryl (polyglactin 910) mesh in a rabbit model. NUMBERS: Eight adult New Zealand white rabbits that received hydroxyapatite orbital implants wrapped in homologous donor sclera (four animals) or Vicryl mesh (four animals). INTERVENTIONS: The rabbits had one eye enucleated and then received a 12-mm hydroxyapatite implant wrapped in sclera or Vicryl mesh. Magnetic resonance imaging (MRI) and bone scintigraphy were done to assess host fibrovascularization of the implant 4, 8, 12 and 20 weeks after implantation. Two animals (one in each group) were killed at each of these times, and the implant was removed for histopathological examination. MAIN OUTCOME MEASURES: Enhancement on MRI, uptake on bone scintigraphy, fibrovascularization seen on histopathological examination. RESULTS: The degree of fibrovascularization was substantial in all the specimens but appeared greater in the Vicryl-mesh-wrapped implants in the first 12 weeks after implantation on both histopathological and MRI studies. At 20 weeks these findings were similar in the two groups. A granulomatous foreign-body giant-cell reaction to both the Vicryl mesh and the implant itself was present up to 8 weeks after implantation. Bone scans showed only grade 1+ activity in all the implants. CONCLUSIONS: Host fibrovascularization in the rabbit appears to occur to a greater degree in Vicryl-mesh-wrapped hydroxyapatite implants than in those wrapped in donor sclera during the first 12 weeks after implantation. Vicryl mesh appears to be an acceptable alternative wrap for the hydroxyapatite implant, eliminating the need for donor sclera and its potential risks of transmissible diseases.

Animals↗