PubMed Health⌕ Search

Biomedical subjects

F S Foster

Publications and source records attributed to F S Foster.

At least 19 recordsLinked to original sources

Estimation methods for flow imaging with high frequency ultrasound.

This article proposes to estimate slow blood flow with high frequency ultrasound imaging. The proposed technique combines 2 methods. First, a statistical method, called Speckle Flow Imaging (SFI) based on the analysis of changes in the speckle pattern along time, gives an index directly related to the total velocity vector. Secondly, a block matching approach estimates the in-plane velocity components. Results on calibrated flow sequences of blood mimicking fluid have shown good agreement with the statistical model. The quantification of flow is achieved with pulsed flow and is also angle independent when the flow is perpendicular to the ultrasound beam. Speckle Tracking has been evaluated on the same data and has shown good estimation of the in-plane velocity vector when the component of velocity perpendicular to the imaging plane is inferior to 1mm/s. The results of these two methods permit the evaluation of the total 3D velocity field and the orthogonal velocity component relative to the imaging plane. This allows the quantification of blood flow (volumetric per time unit across the sequence).

Algorithms↗

Design and fabrication of ultrafine piezoelectric composites.

Making fine scale (< 20 microm) piezoelectric composites for high frequency (> 50 MHz) ultrasound transducers remains challenging. Interdigital phase bonding (IPhB), described in this paper, presents a new technique developed to make piezoelectric composites at the ultrafine scale using a conventional dicing saw. Using the IPhB technique, a composite structure with a pitch that is less than the dicing saw blade thickness can be created. The approach is flexible enough to make composites of different combination of pitch and volume ratio. Using a conventional dicing saw with a 50 microm thick blade, composite with a 25 microm pitch and a volume ratio of 61 percent are fabricated. Such a composite is suitable for fabrication of ultrasonic transducers and arrays with central frequencies of up to 85 MHz. Single element transducers working at central frequencies of 50-60 MHz were made of these composites as a mean to characterize the acoustic performance. Measurement results of the transducers show that the longitudinal electromechanical coupling coefficient is greater than 0.6 and that there are no noticeable lateral resonances in the frequency range of 55-150 MHz. Design criteria for fine scale elements are also discussed based on theoretical results from finite element analysis (FEA).

Ceramics↗

Applications for multifrequency ultrasound biomicroscopy in mice from implantation to adulthood.

A new multifrequency (19-55 MHz) ultrasound biomicroscope with two-dimensional imaging and integrated Doppler ultrasound was evaluated using phantoms and isoflurane-anesthetized mice. Phantoms revealed the biomicroscope's lateral resolution was between 50 and 100 microm, whereas that of a conventional 13 MHz ultrasound system was 200-500 microm. This difference was apparent in the markedly higher resolution images achieved using the biomicroscope in vivo. Transcutaneous images of embryos in pregnant mice from approximately 2 days after implantation (7 days gestation) to near term (17.5 days) were obtained using frequencies from 25 to 40 MHz. The ectoplacental cone and early embryonic cavities were visible as were the placenta and embryonic organs throughout development to term. We also evaluated the ability of the biomicroscope to detect important features of heart development by examining embryos from 8.5 to 17.5 day gestation in exteriorized uteri using 55 MHz ultrasound. Cardiac looping, division of the outflow tract, and ventricular septation were visible. In postnatal imaging, we observed the heart and kidney of neonatal mice at 55 MHz, the carotid artery in juveniles (approximately 8 g body wt) and adults (approximately 25 g body wt) at 40 MHz, and the adult heart, aorta, and kidney at 19 MHz. The coefficient of variation of carotid and aortic diameter measurements was 1-3%. In addition, blisters in GRIP1 -/- embryos and aortic valvular stenosis in two adults were readily visualized. Using image-guided Doppler function, low blood velocities in vessels as small as 100 microm in diameter including the primitive heart tube at day 8.5 were measurable, but high blood velocities (>37.5 cm/s) such as in the heart and large arteries in late gestation and postnatal life were off-scale. Accurate cardiac dimension measurements were impeded by poor temporal resolution (4 frames/s). In summary, the multifrequency ultrasound biomicroscope is a versatile tool well suited to detailed study of the morphology of various organ systems throughout development in mice and for hemodynamic measurements in the low velocity range.

Animals↗

A new ultrasound instrument for in vivo microimaging of mice.

We report here on the design and evaluation of the first high-frequency ultrasound (US) imaging system specifically designed for microimaging of the mouse. High-frequency US or US biomicroscopy (UBM) has the advantage of low cost, rapid imaging speed, portability and high resolution. In combination with the ability to provide functional information on blood flow, UBM provides a powerful method for the investigation of development and disease models. The new UBM imaging system is demonstrated for mouse development from day 5.5 of embryogenesis through to the adult mouse. At a frequency of 40 MHz, the resolution voxel of the new mouse scanner measures 57 microm x 57 microm x 40 microm. Duplex Doppler provides blood velocity sensitivity to the mm per s range, consistent with flow in the microcirculation, and can readily detect blood flow in the embryonic mouse heart, aorta, liver and placenta. Noninvasive UBM assessment of development shows striking similarity to invasive atlases of mouse anatomy. The most detailed noninvasive in vivo images of mouse embryonic development achieved using any imaging method are presented.

Animals↗

Measurement of the ultrasonic properties of human coronary arteries in vitro with a 50-MHz acoustic microscope.

Ultrasonic attenuation coefficient, wave propagation speed and integrated backscatter coefficient (IBC) of human coronary arteries were measured in vitro over the -6 dB frequency bandwidth (36 to 67 MHz) of a focused ultrasound transducer (50 MHz, focal distance 5.7 mm, f/number 1.7). Corrections were made for diffraction effects. Normal and diseased coronary artery sub-samples (N = 38) were obtained from 10 individuals at autopsy. The measured mean +/- SD of the wave speed (average over the entire vessel wall thickness) was 1581.04 +/- 53.88 m/s. At 50 MHz, the average attenuation coefficient was 4.99 +/- 1.33 dB/mm with a frequency dependence term of 1.55 +/- 0.18 determined over the 36- to 67-MHz frequency range. The IBC values were: 17.42 +/- 13.02 (sr.m)-1 for thickened intima, 11.35 +/- 6.54 (sr.m)-1 for fibrotic intima, 39.93 +/- 50.95 (sr.m)-1 for plaque, 4.26 +/- 2.34 (sr.m)-1 for foam cells, 5.12 +/- 5.85 (sr.m)-1 for media and 21.26 +/- 31.77 (sr.m)-1 for adventitia layers. The IBC results indicate the possibility for ultrasound characterization of human coronary artery wall tissue layer, including the situations of diseased arteries with the presence of thickened intima, fibrotic intima and plaque. The mean IBC normalized with respect to the mean IBC of the media layer seems promising for use as a parameter to differentiate a plaque or a thickened intima from a fibrotic intima.

Adult↗

In vitro and in vivo comparison of three different intravascular ultrasound catheter designs.

Intravascular ultrasound (IVUS) is an invasive imaging modality, which provides detailed two-dimensional images of blood vessels. There are currently two different types of IVUS catheters available, namely, the phased-array and the mechanical designs. The operating ultrasound frequency of these catheters ranges from 20 to 40 MHz. This study sought to evaluate the image quality, accuracy of diameter and pullback length measurements, and catheter handling characteristics of three different IVUS catheters currently available for clinical use using both in vitro phantom models and in patients undergoing percutaneous coronary intervention (PCI). In gelatin phantom models, image quality assessed on a semiquantitative scale was significantly different between the three IVUS catheters (P = 0.01) with the 40-MHz catheter providing the best images. Accuracy of lumen diameter measurements, when compared to optical microscopy, were similar between the three IVUS catheter designs (all R(2) = 0.99). There were no significant differences in accuracy of pullback length measurements in vitro between the three designs. However, there were differences in the performance of the three IVUS catheters when used for preinterventional imaging in patients undergoing PCI. Both mechanical IVUS catheters were associated with lower procedural, fluoroscopy, and lesion crossing times compared to the phased-array catheter (all P < 0.05). There were no significant differences between the catheters during postinterventional IVUS imaging. There were also small but potentially important differences with regards to clinical events and complications associated with the use of the different IVUS catheters during the PCI procedures, reflecting differences in catheter design.

Aged↗

Interstitial ultrasound heating applicator for MR-guided thermal therapy.

The ability to control the shape of thermal coagulation was investigated for various interstitial heating applicators incorporating planar transducers and device rotation. Magnetic-resonance-compatible interstitial ultrasound applicators were constructed and the effects of ultrasound power, frequency, scan rate and heating time on lesion radius were studied in heating experiments in excised liver tissue. Continuous thermal lesions were generated by scanning heating applicators over a 180 angular sector. The region of thermal coagulation was restricted to the prescribed sector. Lesion radius increased with acoustic power and heating time and decreased with increasing frequency. The relationship between the temperature distribution generated by the applicator and the resulting thermal lesion was assessed with MRI. Analysis of MR temperature maps revealed that the temperature distribution could be measured accurately within 2 mm from the surface of the applicator, and the boundary of thermal coagulation was defined by a temperature of 54 +/- 12 degrees C. Calculations of temperature distributions indicated that slower scan rates can overcome the tendency of perfusion to reduce the radius of thermal lesion. This applicator design and delivery strategy make conformal interstitial heating possible.

Hot Temperature↗

Ultrasonic integrated backscatter coefficient profiling of human coronary arteries in vitro.

A theoretical formulation for the profile of the integrated backscatter coefficient (IBC) is derived. This new formulation is based on a theoretical treatment by Chen et al. [1]. It includes correction for the diffraction of the ultrasonic beam and correction for the non-ideal nature of the reference signal. The inclusion of these correction factors permits accurate quantitative profiling of the IBC over the transducer focal zone. Experimental measurements are first performed on well-calibrated vessel-equivalent phantom materials and subsequently on human coronary arteries in vitro. A spherically focused 50.0 MHz f/1.83 transducer is used. IBC profiles are shown for three samples that are representative of early, mid, and advanced atherosclerotic coronary disease. The IBC profiles clearly differentiate the arterial tissues. However, variation between samples with histologically confirmed intimal thickening (N = 24) was large. The mean IBC (+/- 1 standard deviation), in (Sr.mm)-1, for media, adventitia, and thickened intima were 3.86 x 10(-3), 1.53 x 10(-2), and 2.24 x 10(-2), respectively. The mean IBC of thickened intima is larger than previous measurements obtained from femoral arteries, and the mean IBC for media and adventitia layers are lower, reflecting differences in tissue composition between coronary and femoral vessels.

Adult↗

Interdigital pair bonding for high frequency (20-50 MHz) ultrasonic composite transducers.

Interdigital pair bonding is a novel methodology that enables the fabrication of high frequency piezoelectric composites with high volume fractions of the ceramic phase. This enhancement in ceramic volume fraction significantly reduces the dimensional scale of the epoxy phase and increases the related effective physical parameters of the composite, such as dielectric constant and the longitudinal sound velocity, which are major concerns in the development of high frequency piezoelectric composites. In this paper, a method called interdigital pair bonding (IPB) is used to prepare 1-3 piezoelectric composite with a pitch of 40 microns, a kerf of 4 microns, and a ceramic volume fraction of 81%. The composites prepared in this fashion exhibited a very pure thickness-mode resonance up to a frequency of 50 MHz. Unlike the 2-2 piezoelectric composites with the same ceramic and epoxy scales developed earlier, the anticipated lateral modes between 50 to 100 MHz were not observed in the current 1-3 composites. The mechanisms for the elimination of the lateral modes at high frequency are discussed. The effective electromechanical coupling coefficient of the composite was 0.72 at a frequency of 50 MHz. The composites showed a high longitudinal sound velocity of 4300 m/s and a high clamped dielectric constant of 1111 epsilon 0, which will benefit the development of high frequency ultrasonic transducers and especially high frequency transducer arrays for medical imaging.

Ceramics↗

High frequency acoustic parameters of human and bovine articular cartilage following experimentally-induced matrix degradation.

Matrix degradation and proteoglycan loss in articular cartilag eare features of early osteoarthritis. To determine the effect of matrix degradation and proteoglycan loss on ultrasound propagation in cartilage, we used papain and interleukin-1alpha to degrade the matrix proteoglycans of human and bovine cartilage samples, respectively. There is also minor collagen alteration associated with these chemical degradation methods. We compared the speed of sound and frequency dependent attenuation (20-40 MHz) of control and experimental paired samples. We found that a loss of matrix proteoglycans and collagen disruption resulted in a 20-30% increase in the frequency dependent attenuation and a 2% decrease in the speed of sound in both human and bovine cartilage. We conclude that the frequency dependent attenuation and speed of sound in articular cartilage are sensitive to experimental modification of the matrix proteoglycans and collagen. These findings suggest that ultrasound can potentially be used to detect morphologic changes in articular cartilage associated with the progression of osteoarthritis.

Adult↗

Advances in ultrasound biomicroscopy.

The visualisation of living tissues at microscopic resolution is attracting attention in several fields. In medicine, the goals are to image healthy and diseased tissue with the aim of providing information previously only available from biopsy samples. In basic biology, the goal may be to image biological models of human disease or to conduct longitudinal studies of small-animal development. High-frequency ultrasonic imaging (ultrasound biomicroscopy) offers unique advantages for these applications. In this paper, the development of ultrasound biomicroscopy is reviewed. Aspects of transducer development, systems design and tissue properties are presented to provide a foundation for medical and biological applications. The majority of applications appear to be developing in the 40-60-MHz frequency range, where resolution on the order of 50 microm can be achieved. Doppler processing in this frequency range is beginning to emerge and some examples of current achievements will be highlighted. The current state of the art is reviewed for medical applications in ophthalmology, intravascular ultrasound, dermatology, and cartilage imaging. Ultrasound biomicroscopic studies of mouse embryonic development and tumour biology are presented. Speculation on the continuing evolution of ultrasound biomicroscopy will be discussed.

Animals↗

High-frequency color flow imaging of the microcirculation.

The extension of ultrasound (US) color flow imaging (CFI) techniques to high frequencies (> 20 MHz) has the potential to provide valuable noninvasive tools for scientific and clinical investigations of blood flow in the microcirculation. We describe the development of a slow-scan CFI system operating in the 20-100-MHz range that has been optimized to image the microcirculation. The apparatus has incorporated elements of a previously reported pulsed-wave Doppler system and is capable of operating in either CFI or pulsed-wave mode. The performance of the CFI system was evaluated at a center frequency of 50 MHz using two PVDF transducers with -6-dB beam widths of 43 and 60 microm. The -6 dB-axial resolutions were estimated to be 66 and 72 microm, respectively. In vivo validation experiments conducted using the murine ear model demonstrated the detection of flow in vessels down to 15-20 microm in diameter with flow velocities on the order of mm per s. Further experiments examining experimental murine tumors confirmed the successful detection of flow in the tumor microcirculation.

Animals↗

Ultrasound for the visualization and quantification of tumor microcirculation.

Advances in ultrasound based methods for the non-invasive assessment of the tumor microcirculation are described. Two new ultrasound approaches are highlighted. The first method relies on commercially available ultrasound contrast agents in combination with specialized nonlinear imaging sequences. Nonlinear scattering by microbubble contrast agents provides a unique intravascular signature that can be distinguished from the echoes caused by surrounding tissues. Through destruction-reperfusion experiments it is possible to use microbubble contrast agents as a tracer revealing the kinetics of tumor blood flow. The second ultrasound method for examining the microcirculation involves the use of much higher frequencies. At frequencies on the order of 50 MHz, Doppler processing allows the direct assessment of flow dynamics in realtime in arterioles as small as 15 microm. Three dimensional Doppler maps of flow patterning are presented. The strengths and weaknesses of these new methods are discussed and the potential for their use in preclinical animal drug studies, clinical drug trials, and prognostic studies is described.

Animals↗

Feasibility of linear arrays for interstitial ultrasound thermal therapy.

The feasibility of linear array transducers for interstitial ultrasound thermal therapy was evaluated. Theoretical acoustic power distributions were used to calculate spatial heating patterns using the bioheat transfer equation. The spatial heating patterns of linear array and single element planar rectangular transducers were compared. Scanned heating with both transducer geometries produced asymmetric heating volumes; however, a more uniform radial temperature profile with a sharper margin was achieved with linear arrays. Single element transducers produced excessive heating near the probe surface. Homogeneous blood flow is predicted to reduce the mean temperature within the heated region, with little effect on the spatial pattern.

Biophysical Phenomena↗

Quantifying tissue damage due to focused ultrasound heating observed by MRI.

Focused ultrasound heating of ex vivo bovine kidney and liver was monitored using magnetic resonance imaging (MRI) to investigate the quantitative relationship between time-dependent temperature elevations and altered contrast in MR images due to thermal coagulation. Proton resonance frequency shift MR thermometry was performed during heating at 10 sec intervals (single-slice fast spoiled GRASS [FSPGR], theta/TE/TR 30 degrees/11/39 msec, field of view 8 cm, 256 x 256, 3 mm slice thickness, 1 NEX); post-heating MR images were T1-weighted (3D-FSPGR, theta/TE/TR 60 degrees/25/200 msec, 1 mm slice thickness, 3 NEX). Analysis of the resulting temperature versus time data using the Arrhenius relationship and a simple binary discrimination model showed that thermal coagulation occurred with heating at approximately 54 degrees C for 10 sec in both tissues and could be predicted with approximately 625 microm spatial resolution. These results suggest that quantitative MR guidance of thermal coagulation therapy is feasible, and they provide information useful for designing future investigations in vivo.

Animals↗

Plateau iris syndrome: changes in angle opening associated with dark, light, and pilocarpine administration.

PURPOSE: To report changes in angle configuration associated with dark, light, and pilocarpine administration in plateau iris syndrome. METHOD: In 10 eyes of 10 patients with plateau iris syndrome and persistent narrow angles after patent peripheral Nd:YAG laser iridotomy, ultrasound biomicroscopy was used to image variations in angle opening, iris thickness, and trabecular-ciliary process distance. Measurements were taken in the dark, in full room light, and after administration of pilocarpine 2%. RESULTS: Average angle opening distance increased in the light compared with the dark (113+/-34 microm vs. 22+/-34 microm, P = .0001) and increased further after pilocarpine administration (171+/-52 microm vs. 113+/-34 microm, P = .0034). Average iris thickness decreased in the light compared with the dark (338+/-34 microm vs. 436+/-58 microm, P = .0009) and decreased further after pilocarpine administration (253+/-48 microm vs. 338+/-34 microm, P = .0002). Average trabecular meshwork-ciliary process distance measurements were smaller than normal and did not change significantly in the light compared with the dark (481+/-42 microm vs. 464+/-44 microm, P = .4001) or after pilocarpine administration compared with light (451+/-67 microm vs. 481+/-42 microm, P = .1304). CONCLUSIONS: In plateau iris syndrome, anteriorly located ciliary processes support the peripheral iris. Changes in angle opening in dark and light are solely related to changes in iris thickness. Pilocarpine produces iris thinning and is an effective method of opening the angle. Ultrasound biomicroscopy can be used to perform a darkroom provocative test, which provides information on whether the angle anatomically closes in the dark.

Anterior Eye Segment↗