Verification of intensity modulated profiles using a pixel segmented liquid-filled linear array.

A liquid isooctane (C8H18) filled ionization chamber linear array developed for radiotherapy quality assurance, consisting of 128 pixels (each of them with a 1.7 mm pitch), has been used to acquire profiles of several intensity modulated fields. The results were compared with film measurements using the gamma test. The comparisons show a very good matching, even in high gradient dose regions. The volume-averaging effect of the pixels is negligible and the spatial resolution is enough to verify these regions. However, some mismatches between the detectors have been found in regions where low-energy scattered photons significantly contribute to the total dose. These differences are not very important (in fact, the measurements of both detectors are in agreement using the gamma test with tolerances of 3% and 3 mm in most of those regions), and may be associated with the film energy dependence. In addition, the linear array repeatability (0.27% one standard deviation) is much better than the film one ( approximately 3%). The good repeatability, small pixel size and high spatial resolution make the detector ideal for the real time profile verification of high gradient beam profiles like those present in intensity modulated radiation therapy and radiosurgery.

Computer Graphics↗

Monte Carlo correction factors for a Farmer 0.6 cm3 ion chamber dose measurement in the build-up region of the 6 MV clinical beam.

Reference dosimetry of photon fields is a well-established subject and currently available protocols (such as the IAEA TRS-398 and AAPM TG-51) provide methods for converting the ionization chamber (IC) reading into dose to water, provided reference conditions of charged particle equilibrium (CPE) are fulfilled. But these protocols cannot deal with the build-up region, where the lack of CPE limits the applicability of the cavity theorems and so the chamber correction factors become depth dependent. By explicitly including the IC geometry in the Monte Carlo simulations, depth-dependent dose correction factors are calculated for a PTW 30001 0.6 cm(3) ion chamber in the build-up region of the 6 MV photon beam. The corrected percentage depth dose (PDD) agrees within 2% with that measured using the NACP 02 plane-parallel ion chamber in the build-up region at depths greater than 0.4 cm, where the Farmer chamber wall reaches the phantom surface.

Calibration↗

Ionization chamber dosimetry of small photon fields: a Monte Carlo study on stopping-power ratios for radiosurgery and IMRT beams.

Absolute dosimetry with ionization chambers of the narrow photon fields used in stereotactic techniques and IMRT beamlets is constrained by lack of electron equilibrium in the radiation field. It is questionable that stopping-power ratio in dosimetry protocols, obtained for broad photon beams and quasi-electron equilibrium conditions, can be used in the dosimetry of narrow fields while keeping the uncertainty at the same level as for the broad beams used in accelerator calibrations. Monte Carlo simulations have been performed for two 6 MV clinical accelerators (Elekta SL-18 and Siemens Mevatron Primus), equipped with radiosurgery applicators and MLC. Narrow circular and Z-shaped on-axis and off-axis fields, as well as broad IMRT configured beams, have been simulated together with reference 10 x 10 cm2 beams. Phase-space data have been used to generate 3D dose distributions which have been compared satisfactorily with experimental profiles (ion chamber, diodes and film). Photon and electron spectra at various depths in water have been calculated, followed by Spencer-Attix (delta = 10 keV) stopping-power ratio calculations which have been compared to those used in the IAEA TRS-398 code of practice. For water/air and PMMA/air stopping-power ratios, agreements within 0.1% have been obtained for the 10 x 10 cm2 fields. For radiosurgery applicators and narrow MLC beams, the calculated s(w,air) values agree with the reference within +/-0.3%, well within the estimated standard uncertainty of the reference stopping-power ratios (0.5%). Ionization chamber dosimetry of narrow beams at the photon qualities used in this work (6 MV) can therefore be based on stopping-power ratios data in dosimetry protocols. For a modulated 6 MV broad beam used in clinical IMRT, s(w,air) agrees within 0.1% with the value for 10 x 10 cm2, confirming that at low energies IMRT absolute dosimetry can also be based on data for open reference fields. At higher energies (24 MV) the difference in s(w,air) was up to 1.1%, indicating that the use of protocol data for narrow beams in such cases is less accurate than at low energies, and detailed calculations of the dosimetry parameters involved should be performed if similar accuracy to that of 6 MV is sought.

Algorithms↗

A Monte Carlo approach for small electron beam dosimetry.

BACKGROUND AND PURPOSE: In treatments where it is necessary to conform the field shape yielding a very small effective beam area, dosimetry and conventional treatment planning may be inaccurate. The Monte Carlo (MC) method can be an alternative to verify dose calculations. A conjunctival mucosa-associated lymphoid tissues lymphoma is presented, to show the importance of an independent assessment in critical situations. MATERIALS AND METHODS: In this work, the MC technique has been employed using the program BEAM (based on EGS4 code). Electron beam simulation has been performed and the results have been compared with those obtained with films. The patient dose distribution has been obtained by two methods: the full Monte Carlo (FMC) simulation and a conventional planning system (PLATO). RESULTS: Concerning dosimetry, some differences have been observed in the comparison of profiles obtained with film and those obtained with the MC method. Moreover, significant differences were found in the patient isodose distribution between both calculation methods. CONCLUSIONS: The results highlight that, in treatments where small beams are needed, conventional dosimetry and planning systems have some limitations. Therefore, an independent and more accurate assessment, such as MC, would be desirable.

Computer Simulation↗

A conformal technique for a ring shaped conjunctive lymphoma treatment.

Radiotherapy is commonly utilised as standard treatment in the so called mucosa-associated lymphoid tissues (MALT), due to the low probability of distant relapse. The particularities of the lesion, make necessary both energy degradation and beam conformation. To keep homogeneity within acceptable limits, a lengthener attached to the electron applicator has been devised to closely fit the anatomy of the patient. Considering the small area of the outcoming field, film dosimetry is preferred, since the dimensions of an ionisation chamber and even of a semiconductor probe might be comparable to the field size.

Adult↗

Midplane dose determination during total body irradiation using in vivo dosimetry.

BACKGROUND AND PURPOSE: During TBI techniques an accurate determination of the dose distribution is very difficult when using commercial treatment planning systems. In order to determine the midplane dose, an algorithm was developed based on the use of in vivo dosimetry. MATERIALS AND METHODS: Scanditronix EDP-30 diodes were placed at the entrance and the exit surface for in vivo dosimetry. The proposed algorithm was validated firstly in a regular and homogeneous phantom of different thickness with an ionization chamber and TL dosimeters and secondly in an Alderson anthropomorphic phantom with TL dosimeters. In this study, in vivo measurements were evaluated in 60 patients and furthermore, in 20 of them, the midplane dose calculated with this algorithm was compared with the method described by Rizzotti A, Compri C, Garusi GF. Dose evaluation to patients irradiated by 60Co beams, by means of direct measurement on the incident and on the exit surfaces. Radiother. Oncol. 1985;3:279-283. RESULTS: No differences were found between the two methods. The differences between dose values calculated with both methods and dose values measured with the ionization chamber and TL dosimeters were within +/-22% and +/-4%, respectively, in the regular and homogeneous phantom and within +/-2% in the Alderson phantom. The algorithm was useful in calculating the midplane dose when heterogeneities as lungs were present. Even when partial transmission blocks were used to reduce the dose to the lungs, the algorithm with modified correction factors gave a midplane lung dose in the Alderson phantom within 1.3% of the measurements with TL dosimeters. For 360 patients' measurements in each A-P and P-A field, the relative deviations were analyzed between the measured and calculated entrance, exit dose and midplane dose and the prescribed dose, always applying the temperature correction factor. These deviations at the entrance dose were within +/-4%. Greater deviations were found for the exit dose measurements. Deviations larger than +/-10% corresponded in general to obese patients, with a thickness over 25 cm. The relative deviations between the total received and prescribed midplane doses in 60 patients were within +/-3%. CONCLUSIONS: The results indicate excellent correspondence between the total prescribed and calculated midplane doses using this algorithm while also no significant differences were found when the Rizzotti method was used. Comparison between doses measured with TL dosimeters in the core of Alderson phantom lungs and doses calculated from in vivo measurements showed that the proposed algorithm could be used in the presence of heterogeneities even when partial transmission blocks were used. The temperature correction factor must be applied in order to avoid a 2-3% dose overestimation.

Humans↗

Computer-based anthropometrical system for total body irradiation.

For total body irradiation (TBI) dose calculation requirements, anatomical information about the whole body is needed. Despite the fact that video image grabbing techniques are used by some treatment planning systems for standard radiotherapy, there are no such systems designed to generate anatomical parameters for TBI planning. The paper describes an anthropometrical computerised system based on video image grabbing which was purpose-built to provide anatomical data for a PC-based TBI planning system. Using software, the system controls the acquisition and digitalisation of the images (external images of the patient in treatment position) and the measurement procedure itself (on the external images or the digital CT information). An ASCII file, readable by the TBI planning system, is generated to store the required parameters of the dose calculation points, i.e. depth, backscatter tissue thickness, thickness of inhomogeneity, off-axis distance (OAD) and source to skin distance (SSD).

Anthropometry↗

A CT-aided PC-based physical treatment planning of TBI: a method for dose calculation.

BACKGROUND AND PURPOSE: As for conventional radiotherapy, one of the basic requirements in Total Body Irradiation (TBI) is to know accurately the dose delivered to the entire body. Both the dosimetry and the treatment planning need to be improved. Physical, technical and dosimetrical aspects of TBI have been widely discussed in the literature. However, to our knowledge, no planning systems specifically designed for TBI are commercially available. This article describes a CT-aided PC-based planning system (TBI-Plansys) and its dose calculation algorithm, which applies scatter and inhomogeneity corrections, developed for the TBI technique currently in use at our centre (AP/PA irradiation with patient positioned on his side). MATERIAL AND METHOD: A description of the material and method followed in the dosimetrical procedure is included as it constitutes the basis of the proposed dose calculation algorithm (more than 2D). A Windows programming environment has been used to develop the software. RESULTS: TBI-Plansys uses patient CT data and indicates absolute and relative dose distributions along midline (at reference points), the transversal axis at the specification point and on transverse sections. The system also calculates the appropriate thicknesses of bolus and shielding to modify undesired dose distributions. TBI-Plansys has been checked against two other well-established systems (beam-zone method and our in vivo semiconductor probe-based system). The checks showed good accuracy with dose differences less than 1% and 3% for homogeneous and inhomogeneous tissues, respectively. CONCLUSIONS: CT calculations by TBI-Plansys allow us to detect undesired distributions which may go unnoticed by calculations at only some specific points. The system has shown clear advantages for routine clinical use as it generates more detailed and accurate information than manual calculations and diminishes the time requirements.

Algorithms↗

Lateral scatter correction algorithm for percentage depth dose in a large-field photon beam.

Differences between the scatter conditions of dosimetry and treatment situation are more important in the case of large-field photon beams than in standard ones. In the former, the scattering volume is defined by the phantom cross section; in the latter, the radiation field size. Two factors should be considered: the thickness and the cross section of the phantom. Both of them have an effect on the Percentage Depth Dose (PDD) distribution. In a previous study we addressed the influence of backscatter thickness on dose delivered. The aim of this work is to measure the effect of cross section phantom on the PDD curves under our TBI treatment conditions. Results showed a strong dependence of the PDDs on this parameter. A semi-empirical expression has also been derived to calculate (within 0.5% uncertainty) the Lateral scatter Correction Factor (LCF). The model of LCF states a linear dependence on depth whilst slope of these curves depends exponentially on distance to the lateral surface. The algorithm is being applied to our practical Total Body Irradiation (TBI) procedure.

Algorithms↗

Constancy of wedge factors in a Siemens Mevatron 74 linear accelerator.

The variation of the wedge factor (WF) with field size is an important piece of data which determines the radiation output in treatments using wedge filters. WF is closely related with the accelerator head layout, and the choice of the wedge tray mounted above or below the jaws plays a predominant role. In this work we have studied the WF variations in our linac and found that, in apparent contradiction with the literature, the WF remains constant with field size. Nevertheless, these results cannot be used directly in other linacs, and individual dosimetry must be carried out.

Particle Accelerators↗

Midline dose algorithm for in vivo dosimetry.

The high level of accuracy required in radiotherapy treatment dosimetry makes necessary good treatment quality control. The common way is the use of in vivo dosimetry equipment that allows the direct measurement of dose delivered to the patient. Control of homogeneity and constancy of the incident beam on the patient can be achieved directly by means of entrance dose measurement; however, control of dose delivered to tumours and internal organs is difficult because of the impossibility of a direct measurement. In this case calculations are made using external measurements (entrance and exit sides of the patient) to obtain the dose delivered. In this work, an algorithm that allows the real-time knowledge of midline dose as a function of thickness and entrance and exit doses coming from semiconductor detectors is presented. By having the electrometer connected to the computer, these three values (entrance, midline, and exit dose) are displayed instantaneously when the algorithm is included in the acquisition program. The model has been developed both for standard (source to surface distance = 100 cm) and special treatment techniques such as total body irradiation (SSD = 314 cm). There is a good agreement of experimental and calculated values with differences below 0.04%.

Algorithms↗