Topical use of tranexamic acid in coronary artery bypass operations: a double-blind, prospective, randomized, placebo-controlled study.

OBJECTIVES: We sought to investigate the effect of topical application of tranexamic acid into the pericardial cavity in reducing postoperative blood loss in coronary artery surgery. METHODS: A prospective, randomized, double-blind investigation with parallel groups was performed. Forty consecutive patients undergoing primary coronary surgery were randomly assigned to group 1 (tranexamic acid group) or group 2 (placebo group). Tranexamic acid (1 g in 100 mL of saline solution) or placebo was poured into the pericardial cavity and over the mediastinal tissues before sternal closure. The drainage of mediastinal blood was measured hourly. RESULTS: Chest tube drainage in the first 24 hours was 485 +/- 166 mL in the tranexamic acid group and 641 +/- 184 mL in the placebo group (P =.01). Total postoperative blood loss was 573 +/- 164 mL and 739 +/- 228 mL, respectively (P =.01). The use of banked donor blood products was not significantly different between the two groups. Tranexamic acid could not be detected in any of the blood samples blindly collected from 24 patients to verify whether any systemic absorption of the drug occurred. There were no deaths in either group. None of the patients required reoperation for bleeding. CONCLUSIONS: Topical application of tranexamic acid into the pericardial cavity after cardiopulmonary bypass in patients undergoing primary coronary bypass operations significantly reduces postoperative bleeding. Further studies must be carried out to clarify whether a more pronounced effect on both bleeding and blood products requirement might be seen in procedures with a higher risk of bleeding.

Administration, Topical↗

[The radial artery in coronary surgery: the midterm clinical and angiographic results and the variation in vasoreactivity over time].

OBJECTIVE: To evaluate the mid-term angiographic results of radial artery grafts used for myocardial revascularization. METHODS: The first 68 consecutive surviving patients who received a radial artery graft proximally anastomosed to the aorta at our institution were restudied in a five-year follow-up (mean 59 +/- 6.5 months); 48 of these patients had already undergone an early angiographic examination. The response of the radial artery to the endovascular infusion of serotonin was evaluated one and five years after surgery and the mid-term status of the radial artery grafts was correlated with the degree of stenosis of the target vessel and with the Ca(++)-channel-blocker therapy. RESULTS: The patency and perfect patency rates of the radial artery five years after the operation were 91.9 and 87.0% respectively. All radial artery grafts that were patent early after surgery remained patent at mid-term follow-up and in seven patients early parietal irregularities disappeared after five years. The early propensity to graft spasm after serotonin challenge decreased markedly at mid-term follow-up. The continued use of Ca(++)-antagonists after the first postoperative year did not affect the status of the radial artery graft, whereas the severity of target-vessel stenosis markedly influenced the angiographic results. CONCLUSIONS: The mid-term angiographic results of RA grafts used for myocardial revascularization are excellent. A correct surgical indication is essential, whereas continued therapy with Ca(++)-antagonists after the first year does not influence the mid-term angiographic results.

Aged↗

Dynamically variable electronic delays for ultrasound imaging.

A novel programmable delay line system (Patent 67595-A/89 from the Ministero dell'Università e della Ricerca Scientifica e Tecnologica, Italy) for electronic control of delay profile in ultrasound real-time imaging systems is described. The line consists of a number of LC filters. The capacitance is obtained by using varicap diodes, so that electronic control over the desired depth is obtained by changing the diode inverse polarization voltage. This delay line exhibits a dramatic simplification and a broader time delay excursion than alternative techniques. Based on computer simulations, a delay line system was designed and integrated into an annular transducer-based echographic apparatus.

Computer Systems↗