PubMed Health⌕ Search

Biomedical subjects

F Schiele

Publications and source records attributed to F Schiele.

At least 19 recordsLinked to original sources

Predictive value of admission hyperglycaemia on mortality in patients with acute myocardial infarction.

RATIONALE AND AIM: In patients with an acute myocardial infarction, admission hyperglycaemia (AH) is a major risk factor for mortality. However, the predictive value of AH, when the risk score and use of guidelines-recommended treatments are considered, is poorly documented. METHODS: The first fasting plasma glucose levels after admission, risk level, guidelines-recommended treatment use and 1-year mortality were recorded. Patients with first fasting glucose level after admission > 7.7 mmo/l were considered to have AH. RESULTS: Three hundred and twenty patients with ST segment elevation myocardial infarction (STEMI) and 404 with non-ST segment elevation myocardial infarction (NSTEMI) were included. One hundred and seventy-five (24%) patients had pre-existing diabetes (diabetes group), 154 (21%) had AH (AH+ group) and the remainding 395 (55%) had neither diabetes nor AH (AH- group). The Global Registry of Acute Coronary Events (GRACE) risk score was lower in the AH- group, but the use of guidelines-recommended treatment was comparable in all groups. At 1 year, the mortality rate was higher in the AH+ group compared with the AH- group (18.8 vs. 6.1%, P < 0.01) and similar to that in the diabetes group (18.8 vs. 16.6%, P = NS). The relation between glycaemic status and mortality remained strong [AH+ vs. AH-, OR = 3.0 (1.5, 6.0) and diabetes vs. AH-, OR = 3.6 (1.7, 6.6)] after adjustment for the GRACE risk score [OR = 2.4 (1.8, 3.1) per 10% increase] and for treatment score [OR = 0.7 (0.6, 0.8) per 10% increase]. CONCLUSIONS: In patients without a history of diabetes, the presence of AH indicates an increased risk of 1-year mortality, similar to that of patients with diabetes, even when the risk score and use of guidelines-recommended treatment are controlled for.

Aged↗

[Chronic renal failure: an independent factor of mortality after myocardial infarction].

PURPOSE: The prognostic significance of glomerular filtration rate (GFR) was studied in a registry of 754 patients admitted for myocardial infarction in Franche Comté; 333 of them had STEMI. PATIENTS AND METHODS: One-year mortality was 11.5%: 2.3% in the group with normal GFR, 9.4% in the group with moderate renal failure, and 24.2% in the group with severe renal failure. GFR increased the prognostic value of conventional risk scores. CONCLUSION: Chronic renal failure therefore appears as a major independent predictor of mortality after myocardial infarction.

Aged↗

[Predictive factors of restenosis: what changes with "active" stents?].

For many years, restenosis was the major limiting factor of coronary angioplasty, even since the systematic use of stents. Numerous scientific publications have aimed to define the predictive factors of this phenomenon. Factors such as diabetes, the size of the treated artery, the use of stents or not, the length of the lesion, lesion located on the proximal left anterior descending artery, the degree of residual stenosis post-angioplasty (assessed by angiography or by intravascular ultrasound) have all been evoked as being classically related to restenosis. However, our perception of the restenosis phenomenon has been dramatically changed by the demonstration of the efficacy and security of active stents. Even in so-called "at risk" populations, the use of active stents is rarely followed by restenosis. In this way, the classic risk factors for restenosis have now become arguments in favour of the implantation of an active stent. As long as budgetary constraints limit the use of active stents to patients said to be "at risk of restenosis", this population, quite paradoxically, will have a more favourable outcome than so-called "low risk" patients, in whom "ordinary" non-active stents will continue to be used.

Angioplasty, Balloon, Coronary↗

False lumen patency as a predictor of late outcome in aortic dissection.

Aortic dissection (AD) is a disease with a high-risk of mortality. Late deaths are often related to complications in nonoperated aortic segments. Between 1984 and 1996, we retrospectively analyzed the data of 109 patients with acute AD (81 men and 28 women; average age 61 +/- 14 years). All imaging examinations were reviewed, and a magnetic resonance imaging examination was performed at the time of the study. Aortic diameters were measured on each aortic segment. Predictive factors of mortality were determined by Cox's proportional hazard model, in univariate and multivariate analyses, using BMDP statistical software. Follow-up was an average of 44 +/- 46 months (range 24 to 164). Actuarial survival rates were 52%, 46%, and 37% at 1, 5, and 10 years, respectively, for type A AD versus 76%, 72%, and 46% for type B AD. Predictors of late mortality were age >70 years and postoperative false lumen patency of the thoracic descending aorta (RR 3.4, 95% confidence intervals 1.20 to 9.8). Descending aorta diameter was larger when false lumen was patent (31 vs 44 mm; p = 0.02) in type A AD. Furthermore, patency was less frequent in operated type A AD when surgery had been extended to the aortic arch. Thus, patency of descending aorta false lumen is responsible for progressive aortic dilation. In type A AD, open distal repair makes it possible to check the aortic arch and replace it when necessary, decreases the false lumen patency rate, and improves late survival.

Adult↗

Production and certification of an enzyme reference material for adenosine deaminase 1 (BCR 647).

BACKGROUND: We describe the preparation of a lyophilised reference material containing purified human adenosine deaminase 1 and the certification of its catalytic concentration. METHODS: The enzyme was purified from human erythrocytes. RESULTS: The enzyme was >99% pure on polyacrylamide gel electrophoresis. Only trace amounts (<0.4%) of alanine aminotransferase, aspartate aminotransferase and L-lactate dehydrogenase were detected in the purified fraction. The purified adenosine deaminase had a molar mass of 41600 g/mol and an isoelectric pH at 4.7, 4.85 and 5.0. The material was prepared by diluting the purified adenosine deaminase in a matrix containing 50 mmol/l Tris-HCl buffer pH 7.4 and 30 g/l human serum albumin; dispensing in vials and freeze-drying. The batch was homogeneous and the predicted loss of adenosine deaminase activity per year on the basis of accelerated degradation studies was 0.006% at -20 degrees C and 0.04% at 4 degrees C. The certified value for adenosine deaminase catalytic concentration in the reconstituted reference material is (2.55+/-0.09) microkat/l when measured by the method that uses adenosine as substrate and glutamate dehydrogenase as auxiliary enzyme at 37 degrees C. CONCLUSIONS: The material can be used to verify the comparability of results from different laboratories, for intra-laboratory quality control, or for calibration of the adenosine deaminase catalytic concentration measurements.

Adenosine Deaminase↗

Apolipoproteins E and C-III in apo B- and non-apo B-containing lipoproteins in middle-aged women from the Stanislas cohort: effect of oral contraceptive use and common apolipoprotein E polymorphism.

Oral contraceptive (OC) use and common apo E polymorphism are well known to modify serum lipid and lipoprotein concentrations. The combined effect of OC use and apo E genotype on the concentration of apo E or apo C-III in apo B- (apo E-LpB or apo C-III-LpB) or in non-apo B-containing lipoparticles (apo E-Lp-non-B or apo C-III-Lp-non-B) are unknown. Our study comprised 613 women, aged 30-45 years, genotyped for common apo E polymorphism and who differed in their combined low-dose OC consumption. The concentrations of apo C-III, apo C-III-LpB and apo C-III-Lp-non-B were significantly higher in OC users than in non-users by 13, 23 and 8% respectively, without significant interaction with the apo E genotype. The concentrations of apo E and apo E-Lp-non-B were significantly lower (differences being -14% and -31% respectively) in OC users than in controls whereas the apo E-LpB concentration was significantly higher (+19%), resulting in a redistribution of apo E from Lp-non-B towards LpB. Total apo E and apo E-Lp-non-B concentrations were higher in subjects carrying the epsilon2 allele and lower in those with the epsilon4 allele when compared to epsilon3/epsilon3 subjects (P < 0.001). The opposite held for the apo E- LpB concentration (P < 0.05). The main finding is the significant interaction between apo E genotype and OC use (P < 0.01) on apo E-Lp-non-B concentration, the epsilon4 carriers showing the smallest differences between OC users and non-users in comparison with the epsilon2 or epsilon3/epsilon3 carriers. These results suggest that the common apo E polymorphism can modulate the OC use effect.

Adult↗

Lack of agreement between left ventricular volumes and ejection fraction determined by two-dimensional echocardiography and contrast cineangiography in postinfarction patients.

OBJECTIVE: To assess the agreement between left ventricular (LV) volumes and ejection fraction (EF) determined by two-dimensional echocardiography (2-D echo) and by cineangiography in postinfarction patients. DESIGN: LV end-diastolic and end-systolic volumes indexed (EDVI and ESVI) to body surface area as well as EF were determined by both methods in all patients. SETTING: Multicenter trial conducted in five university hospitals. PATIENTS: 63 patients, 61 male, two female, mean age 55.5 +/- 10.4 years, suffering from a recent myocardial infarction. Eighty-one pairs of measurements were available. METHODS: The results of biplane 2-D echo measures, using apical four-chamber (4C) and two-chamber (2C) views were compared to those of a 30 degrees right anterior oblique cineangiography projection, using either the apical method of discs or the area-length 2-D echo method. Moreover, eyeball EF was estimated at 2-D echo and cineangiography, and was compared to the conventional methods. The agreement between results was assessed by the Bland and Altman method. RESULTS: The agreement between 2-D echo and cineangiography results was poor. Mean differences (MD) were -21.8 (EDVI, ml/m(2)), -9.5 (ESVI, ml/m(2)), and -0.9 (EF, %), respectively for 2-D echo method of discs versus cineangiography, and -23.2, -9.3, and -5.7 for area-length 2-D echo versus cineangiography. For EF (%), MD was -3.6 for eyeball cineangiography versus cineangiography, -1.3 for eyeball 2-D echo versus method of discs, and +0.30 for eyeball 2-D echo versus area-length 2-D echo, respectively. Two-dimensional echo is likely to underestimate LV volumes compared to cineangiography, especially for largest volumes. Even for EF, discrepancies are large, with a lack of agreement of 21%-25% between conventional methods, but agreement is better between eyeball EF and usual methods. CONCLUSIONS: Even with modern echocardiographic devices, agreement between 2-D echo and cineangiography-derived LV volumes and EF remains moderate, and both methods must not be considered interchangeable in clinical practice.

Adult↗

Cytomegalovirus, Chlamydia pneumoniae, and Helicobacter pylori IgG antibodies and restenosis after stent implantation: an angiographic and intravascular ultrasound study.

OBJECTIVE: To determine the impact of previous infection with cytomegalovirus, Chlamydia pneumoniae, and Helicobacter pylori on neointimal proliferation after coronary angioplasty with stent implantation. DESIGN: The study population was made up of 180 patients who had stent implantation in a native coronary artery with systematic angiographic and intravascular ultrasound (IVUS) follow up at six months. Quantitative coronary angiography was used to assess the late lumen loss. The mean area of neointimal tissue within the stent and the ratio of neointimal tissue to stent area were assessed from IVUS images. Previous cytomegalovirus, C pneumoniae, and H pylori infection was identified by IgG antibody determination. RESULTS: Previous cytomegalovirus infection was detected in 50% of the population, previous C pneumoniae in 18%, and previous H pylori in 33%. Mean (SD) reference diameter was 2.94 (0.48) mm and mean minimum lumen diameter after stent implantation was 2.45 (0.42) mm. At six months, the mean late loss was 0.74 (0.50) mm, the mean neointimal tissue area was 3.8 (1.7) mm(2), and the average ratio of neointimal tissue area to stent area was 45 (18)%. None of these variables of restenosis was linked to any of the three infectious agents. By multivariate analysis, lesion length was the variable best correlated with mean neointimal tissue area, the ratio of neointimal tissue to stent area, and late loss, explaining respectively 31%, 39%, and 8% of their variability. CONCLUSIONS: Previous infection with cytomegalovirus, C pneumoniae, or H pylori was not a contributing factor in the process of restenosis after stent implantation.

Angioplasty, Balloon, Coronary↗

Intracoronary stent implantation under intracoronary ultrasound guidance with aspirin and ticlopidine therapy.

OBJECTIVE: To observe the immediate angiographic and intravascular ultrasound (IVUS) results and their effects on one month clinical outcomes in forty-one patients who submitted to coronary stent deployment with IVUS guidance. METHODS: All patients were allocated to coronary stent implantation with high inflation pressure. After good angiographic results (< 20% residual stenosis), all patients underwent IVUS and higher-pressure dilatation would be necessary if criteria for optimal coronary stent implantation were not met. The optimal criterion of IVUS for stent implantation was the ratio of intrastent lumen cross-sectional area to the average of the proximal and distal reference lumen cross-sectional areas > or = 80%. All patients had aspirin and ticlopidine therapy on the day of angioplasty and during the one month follow-up period. RESULTS: Optimal criteria of IVUS were obtained without any further intrastent dilatation in twenty-five patients but intrastent higher-pressure dilatation was performed in fourteen patients whose ultrasound results did not reach the criteria. In these patients, we increased the minimal intrastent lumen area 25.7% (P < 0.05). Thirty-five patients (90%) had good minimal intrastent lumen area of IVUS. There were no deaths, myocardial infarction, acute stent thrombosis or need for revascularization during the study and the one month follow-up. CONCLUSIONS: Intracoronary stent deployment under IVUS guidance, including combining aspirin and ticlopidine therapy, had beneficial ultrasound results and good clinical outcomes after one month follow-up.

Aged↗

Predictors of clinical outcome following percutaneous intervention for in-stent restenosis.

Percutaneous intervention for the first episode of in-stent restenosis was performed in 177 patients 5.4 +/- 0.3 months after native coronary stent implantation. Medical records were reviewed and patients contacted 13.3 +/- 1.2 months after in-stent intervention to ascertain the subsequent clinical course. The effects of demographic, procedural, and angiographic variables on clinical outcomes were determined. At 2 years, Kaplan-Meier estimated survival was 93 +/- 3% and freedom from death, myocardial infarction, and a third target artery revascularization (TAR) was 67 +/- 4%. The actuarial frequency of a third TAR was 26 +/- 4% at 1 year. Stratification of outcomes according to timing of in-stent intervention revealed an approximate twofold higher frequency of adverse events among patients with early (</=3 months) in-stent restenosis. Advanced age (p = 0.019), prior coronary bypass (p = 0. 017), and early in-stent intervention (p = 0.006) independently predicted increased mortality at follow-up. Systemic hypertension (p = 0.004), diabetes mellitus (p = 0.044), and early in-stent intervention (p <0.0001) independently predicted a third TAR. These variables (p = 0.007, p = 0.027, and p <0.0001, respectively) also independently predicted a composite end point consisting of death, myocardial infarction, and a third TAR. No angiographic variable predicted outcome after in-stent intervention. Thus, long-term outcome following in-stent intervention was favorable. Early in-stent intervention, advanced age, hypertension, and diabetes predicted adverse outcomes.

Actuarial Analysis↗

Effects of pro-inflammatory cytokines on apolipoprotein E secretion by a human astrocytoma cell line (CCF-STTG1).

Apolipoprotein (apo) E has been implicated in Alzheimer's disease; however, little is known about the regulation of its secretion in astrocytes. To investigate the effects of pro-inflammatory cytokines such as interleukin-1beta (IL-1beta), tumour necrosis factor-alpha (TNF-alpha) and interferon-gamma (IFN-gamma) on apoE secretion by CCF-STTG1 cells, a sensitive and specific double sandwich Enzyme-Linked ImmunoSorbent Assay (ELISA) was developed. Using a monoclonal anti-human apoE antibody as the capture antibody, this assay was carried out with commercially available reagents. The assay had a sensitivity of 0.013 ng per well, within-run and between-run variation coefficients of 6.0 and 8.6 per cent respectively. There was no cross-reactions between antibodies used and apoAI, apoAII, apoB, apoCI, apoCII and apoCIII. Low apoE concentrations were assessed using a serum-free HepG2 culture medium as secondary calibrator, containing 59 microg l(-1) of apoE. In serum-free medium, CCF-STTG1 cells secreted apoE, the accumulation of which in the cell medium increased linearly with time (27 microg per 48 h). After 48 h of incubation, apoE secretion was inhibited by TNF-alpha but not affected by IL-1beta and IFN-gamma. However, the effect of regulatory factors may depend upon culture conditions since in the presence of 10 per cent fetal calf serum, IFN-gamma significantly inhibited apoE secretion. Thus, apoE secretion by CCF-STTG1 cells is inhibited by specific pro-inflammatory cytokines. This new apoE ELISA presents the great advantage of using commercially available reagents which permit inter-laboratory comparability of results, involves relatively low cost and is adaptable for the measurement of low levels of apoE.

Apolipoproteins E↗

Apolipoprotein E serum concentration and polymorphism in six European countries: the ApoEurope Project.

As part of the ApoEurope Project, the apolipoprotein E (apo E) serum concentration and polymorphism were determined in 6934 healthy subjects aged 25-64 years recruited in six European countries: Finland; France; Greece; Northern Ireland; Portugal and Spain. Age and sex influenced apo E concentration with concentrations being significantly higher in men than in women for those aged between 25 and 44 years. The age effect differed between the sexes after the age of 44 years, displaying a linear increase in women and a plateau in men. As expected, the serum apo E concentration was highest in varepsilon2 carriers and lowest in varepsilon4 carriers in each country with a significantly higher frequency of the varepsilon4 allele in the northern regions. The main finding of this study was a clear increasing North-South gradient in serum apo E concentration independent of age, sex and apo E genotype. In subjects aged <45 years and with the varepsilon3/varepsilon3 genotype, apo E concentration was higher in the South-East (Greece) as compared to the North by 20% for men and 32% for women. In addition to the genetic polymorphism, the geographical area is an important factor to take into account when studying serum apo E concentration in multicentre studies and defining reference values.

Adult↗

Predictors of event-free survival after repeat intracoronary procedure for in-stent restenosis; study with angiographic and intravascular ultrasound imaging.

AIMS: Lumen enlargement during repeat percutaneous coronary intervention for in-stent restenosis has been shown to be the result of both stent over-expansion and decrease in neointimal tissue. How these two different mechanisms of action may influence outcome and target lesion revascularization after repeat intervention for in-stent restenosis is unclear. METHODS: Intravascular ultrasound guided repeat intervention for in-stent restenosis was carried out either with balloon angioplasty, or with a combination of rotational atherectomy plus balloon angioplasty. Clinical follow-up at 1 year, including death, myocardial infarction, or need for revascularization, was obtained. RESULTS: Seventy patients were included in this study; 40 were treated by balloon alone, and 30 by combination of rotational atherectomy plus balloon. Event-free survival probability was 76+/-5%. The mechanism of lumen enlargement, be it stent over-expansion or tissue removal, had no influence on long-term clinical evolution. The only independent predictor was the minimal lumen cross-sectional area at the end of the procedure, the larger the lumen cross-sectional area, the higher the event-free probability. The cut-off point of the lumen cross-sectional area was set at 4.7 mm(2)by discriminant analysis. Event-free survival was 69+/-15% in patients with <4.7 mm(2)lumen cross-sectional area and 91+/-8% in patients with >4.7 mm(2)lumen cross-sectional area (P=0. 008). CONCLUSIONS: This study showed that the only independent predictor of late clinical outcome after percutaneous re-intervention for in-stent restenosis was final lumen size, no matter which means were used to achieve it.

Angioplasty, Balloon, Coronary↗

Local delivery of nadroparin for the prevention of neointimal hyperplasia following stent implantation: results of the IMPRESS trial. A multicentre, randomized, clinical, angiographic and intravascular ultrasound study.

BACKGROUND: We hypothesized that intramural delivery of nadroparin, a low molecular weight heparin, would prevent in-stent restenosis by inhibiting neointimal hyperplasia in an angioplasty model free of arterial remodelling. METHODS AND RESULTS: In a prospective randomized multicentre trial, 250 patients submitted to balloon angioplasty followed by stent implantation were randomized into control group (no local drug delivery) or intramural delivery of nadroparin (2 ml of 2500 anti-Xa-units/ml with a microporous catheter). An ancillary intravascular ultrasound substudy was performed to supplement angiographic data with specific measurements of in-stent neointimal hyperplasia. The primary end-point was the late loss in minimal luminal diameter on the 6 month follow-up angiogram. Secondary end-points included feasibility and safety of local nadroparin delivery, and major adverse cardiac events at 8 weeks and 6 months follow-up. Local delivery of nadroparin was successful in 124 patients (99.2% success rate) and was not associated with an increase in stent thrombosis, coronary artery dissection, side branch occlusion, distal embolization or abrupt arterial closure. At angiographic follow-up, the late loss in lumen diameter was 0.84 +/- 0.62 mm in the control group compared to 0.88 +/- 0.63 mm in the nadroparin group (P=0.56). Angiographic restenosis rate (defined as a >50% diameter stenosis) did not differ in the control group (20%) compared to the nadroparin group (24%). The average area of neointimal tissue within the stent was 2.86 +/- 0.64 mm(2) vs 2.90 +/- 0.53 mm(2) (P=0.57), control vs nadroparin groups. There was no difference in major adverse cardiac events at any time (88.8% vs 89.6% event free survival at 6 months, control vs nadroparin). CONCLUSION: Intramural delivery of nadroparin with a microporous catheter after stent deployment was feasible and safe but had no effect in reducing restenosis or the occurrence of major adverse clinical events over 6 months.

Adult↗

Effect of short- and long-term storage on human serum and recombinant apolipoprotein E concentration.

In order to assess the short- and long-term stability of apolipoprotein (apo) E concentration in serum, we compared the apo E concentrations measured in fresh human serum samples with those determined after storage at +4 degrees C, -20 degrees C or -80 degrees C. The serum apo E concentration was measured by immunoturbidimetry using an anti-human apo E polyclonal antibody from goats. One week storage at +4 degrees C did not significantly affect the serum apo E concentration. At -20 degrees C or -80 degrees C no significant change in apo E concentration occurred during up to three months of storage. Moreover, the concentration of apo E was not modified after long-term storage of serum samples kept at -196 degrees C in liquid nitrogen for up to four years. In addition, 15 freeze-thaw cycles, over a 3-week period, did not affect the apo E concentration in serum. A similar freeze-thaw procedure applied to purified human recombinant apo E showed that apo E2 isoform was the most stable in comparison with the apo E3 and apo E4 isoforms.

Apolipoproteins E↗