PubMed Health⌕ Search

Biomedical subjects

F Senf

Publications and source records attributed to F Senf.

6 recordsLinked to original sources

Dynamic stabilization in 1sigma(u)-->1pi(g) excited nitrogen clusters.

High-resolution 1s near-edge spectra of molecular nitrogen and variable size nitrogen clusters obtained using monochromatic synchrotron radiation from the high brilliance BESSY-II storage ring facility are reported. The vibrationally resolved 1sigma(u)-->1pi(g) core-to-valence excitation band of clusters shows a distinct redshift of 6+/-1 meV relative to the isolated molecule, but the vibrational structure and linewidths are essentially unchanged. This shift is assigned to dynamic stabilization of 1sigma(u)-->1pi(g) excited molecules in clusters, arising from the dynamic dipole moment generated by core-hole localization in the low-symmetry cluster field. This leads to changes in intermolecular interactions compared to the ground-state cluster. Such spectral shifts are expected to occur generally in molecular clusters and in the corresponding condensed phase.

Journal Article↗

A new UHV angle encoder for high-resolution synchrotron radiation monochromators.

The high precision of 0.1 arcsec required for the positioning of optical elements in new two-axes monochromators at the undulator beamlines at BESSY II has led to the development of UHV-compatible high-precision angle encoders. Mounted directly on the rotation axes, they provide substantial advantages over measuring systems connected outside the vacuum vessel. Making use of a fast closed-loop control system, an accuracy of 0.1 arcsec at a resolution of less than 0.01 arcsec has been experimentally verified.

Journal Article↗

A plane-grating monochromator for circularly polarized undulator radiation at BESSY II.

At BESSY II, a third-generation 1.7 GeV storage ring is under construction. A planar elliptical undulator will be installed as a source of X-rays that have a high degree of circular polarization. Radiation in the first, third and fifth harmonics will cover the energy range 87-1330 eV. The beamline will essentially consist of a plane-grating monochromator working with collimated light in the dispersion plane. A single set of optical elements can be used to handle the two angularly separated beams of opposite helicity from the double undulator. The degree of circular polarization ranges from 73 to 100%, and a flux of up to 5 x 10(13) photons s(-1) (100 mA)(-1) can be achieved. A maximum spectral resolution of about 13 000 will be possible at 100 eV using a 20 micro m slit.

Journal Article↗

A plane-grating monochromator beamline for the PTB undulators at BESSY II.

At the BESSY II storage ring, the Physikalisch-Technische Bundesanstalt (PTB) will operate insertion devices dedicated to radiometric use. One branch of the appendant beamline system will be equipped with a grazing-incidence monochromator, described here. The monochromator concept is based on a plane grating operated in parallel light; therefore exact focusing is maintained for all photon energies irrespective of the angular setting at the grating. The monochromator has been optimized for small higher-order transmittance and high power throughput, as required by radiometric applications in the wide photon energy range from 20 eV to 1900 eV.

Journal Article↗

Plane-grating monochromator at BESSY II using collimated light.

At the German synchrotron radiation facility BESSY II, the VUV photon energy range between 15 and 600 eV is covered by the first, third and fifth harmonics of the U125 undulator. The beamline connected to this source is a plane-grating monochromator (PGM) with a variable deviation angle. The plane grating is illuminated by collimated radiation, allowing very flexible use of the monochromator. Depending on users' demands, it can be operated at high spectral resolution, high-order suppression or in high-flux mode, simply by software control.

Journal Article↗