PubMed Health⌕ Search

Biomedical subjects

F Smaill

Publications and source records attributed to F Smaill.

21 records · Page 2Linked to original sources

Combined testing for antibodies to rubella non-structural and envelope proteins sentinels infections in two outbreaks.

Two separate outbreaks of Rubella occurred in Hamilton, Ontario, Canada, 7 yrs apart, with a peak incidence for both in the month of April. A total of 138 cases, 51 in 1978 and 87 in 1985, was observed, the majority being in adolescents and young adults 15-25 years of age. Cases were diagnosed by the presence of Rubella IgM antibody or the combination of a negative passive hemagglutination (Rubacell-Abbott) and a positive enzyme immunoassay (EIA) or hemagglutination inhibition (HI) test on a single serum or by seroconversion for Rubella IgG antibody. Routine screening of sera with the Rubacell test, which measures antibodies to nonstructural rubella proteins together with HI or EIA testing of the negatives, served as a sentinel for rubella infection in the community during both outbreaks. Rubacell antibodies usually appeared 2-3 wk after onset of infections, and when present contained either or both IgG and IgM. Only 8/103 cases had a history of Rubella vaccination. Two of three products of conception yielded rubella virus in cell culture.

Adolescent↗

Detection of Chlamydia trachomatis in genitourinary tract specimens using an automated enzyme-linked fluorescent immunoassay.

BACKGROUND AND GOAL: The VIDAS Enzyme Linked Fluorescent Assay is a fully automated assay for the detection of Chlamydia trachomatis in clinical specimens. Because there is an increasing demand for automated assays for large volume laboratories and there is little performance data available, the authors evaluated the performance of the VIDAS enzyme linked fluorescent assay by comparing it with Chlamydiazyme and polymerase chain reaction. STUDY DESIGN: Endocervical swabs from 330 women attending a hospital based obstetrics/gynecology clinic and 100 first void urine specimens from males attending a sexually transmitted disease clinic were tested by enzyme linked fluorescent assay, Chlamydiazyme, and polymerase chain reaction. RESULTS: Fourteen of 330 endocervical specimens and 14 of 100 first void urine specimens were positive by Chlamydiazyme. Enzyme linked fluorescent assay detected 12 of 14 endocervical and 11 of 14 first void urine specimens. Compared with Chlamydiazyme, enzyme linked fluorescent assay had a sensitivity of 85.7% (12 of 14) for endocervical swabs and 76.9% (11 of 14) for first void urine specimens. Polymerase chain reaction detected an additional five endocervical and two first void urine specimens that had negative results by both enzyme linked fluorescent assay and Chlamydiazyme. All 7 were confirmed positive by polymerase chain reaction using a second primer set. Using an expanded gold standard of blocked Chlamydiazyme and confirmed polymerase chain reaction, enzyme linked fluorescent assay had a sensitivity of 63.2% (12 of 19) for endocervical swabs and 68.8% (11 of 16) for first void urine specimens compared with 73.7% (14 of 19) and 87.5% (14 of 16) for Chlamydiazyme. Polymerase chain reaction had a sensitivity of 100% (19 of 19) and 93.8% (15 of 16) for endocervical swabs and first void urine specimens, respectively. The specificity of enzyme linked fluorescent assay and Chlamydiazyme was 100%. CONCLUSIONS: The VIDAS enzyme linked fluorescent assay for the detection of Chlamydia trachomatis in genitourinary specimens is highly specific but is not sufficiently sensitive for use as a routine diagnostic test.

Automation↗