PubMed Health⌕ Search

Biomedical subjects

F Spielberg

Publications and source records attributed to F Spielberg.

7 recordsLinked to original sources

Slow diffusion of home HIV-specimen collection: provider concerns at odds with client preferences.

BACKGROUND: Home specimen collection and telephone counseling (HSCTC) may be a convenient new method for detection of HIV infection among cohorts at high-risk for HIV. GOAL: To evaluate attitudes about HSCTC among participants, HIV counselors, and community advisory board members associated with a national multisite study of persons at high risk for HIV. STUDY DESIGN: Twelve focus groups and surveys were conducted at six sites among 126 counselors, community advisory board members, and cohort participants. RESULTS: Staff and community advisory board members raised concerns about the acceptability, feasibility, safety, and effectiveness of HSCTC. In contrast, participants (92%) reported a willingness to collect blood and oral samples on a frequent basis, and preferred telephone (73%) to office-based counseling. CONCLUSION: Home specimen collection and telephone counseling appear to be preferred by study participants at high risk of HIV infection. Staff and community advisory board members had stronger reservations than prospective users.

Adolescent↗

Moving from apprehension to action: HIV counseling and testing preferences in three at-risk populations.

This study sought to identify factors influencing HIV testing decisions among clients at a sexually transmitted disease clinic, gay men, and injection drug users. Focus group and intensive interview data were collected from 100 individuals. The AIDS Risk Reduction Model was adapted to describe factors that affect test decisions. Testing barriers and facilitators were grouped as factors affected by "Individual" beliefs, "System" policies and programs, "Testing" technology, and "Counseling" options. Individual factors (fear of death and change), system factors (anonymous test availability, convenience), and counseling and testing factors (rapid results, counseling alternatives) interact to determine whether an individual does not test ("apprehension") or does test ("action"), and ultimately, tests routinely ("integration"). In conclusion, traditional HIV testing presents barriers to some populations at risk for HIV. These findings suggest several strategies to improve HIV test acceptance: acknowledge fears, address system barriers, utilize available test technologies, and expand counseling options.

AIDS Serodiagnosis↗

Voluntary counseling, testing, and referral for HIV: new technologies, research findings create dynamic opportunities.

Programs for voluntary counseling and testing (VCT) for HIV play an increasingly important role in comprehensive prevention and care strategies. New technological advancements and behavioral interventions can improve the effectiveness of VCT as a tool for preventing new HIV infections and helping HIV-positive individuals access appropriate care. With growing consensus that early access to HIV therapy increases its effectiveness, and that individuals diagnosed with HIV reduce risk behavior, VCT has become integral to the continuum of HIV primary care. However, federal funding of VCT has declined, with concomitant decreases in numbers of people being tested. An estimated 200,000 people in the United States remain unaware that they are HIV positive, and many at-risk individuals do not seek out standard HIV counseling and testing services. To increase the acceptability and effectiveness of VCT, the authors recommend that VCT programs employ outreach programs offering anonymous testing to reach those at heightened risk of HIV infection, and to make rapid use of new technologies and counseling strategies to improve the reach and efficacy. Given the important role that VCT can play in both prevention and early treatment, the authors recommend significant increases in federal support.

Confidentiality↗

Home collection for frequent HIV testing: acceptability of oral fluids, dried blood spots and telephone results. HIV Early Detection Study Group.

OBJECTIVE: To assess the feasibility and acceptability of bimonthly home oral fluid (OF) and dried blood spot (DBS) collection for HIV testing among high-risk individuals. DESIGN: A total of 241 participants [including men who have sex with men (MSM), injecting drug users (IDU), and women at heterosexual risk] were recruited from a randomly selected subset of study participants enrolled at four sites in the HIV Network for Prevention Trials (HIVNET) cohort, and assigned at random to bimonthly home collection of OF or DBS specimens over a 6 month interval. Participants could select telephone calls or clinic visits to receive HIV test results. METHODS: Bimonthly specimens were tracked for adherence to the schedule, were evaluated for adequacy for testing, and tested using antibody assays and polymerase chain reaction (PCR) for DBS. The acceptability of bimonthly home OF and DBS collection and telephone counseling was assessed in an end-of-study questionnaire. RESULTS: The laboratory received 96 and 90% of expected OF and DBS specimens, respectively; 99% of each specimen type was adequate for testing. Almost all (95%) participants chose results disclosure by telephone. The majority of participants (85%) reported that bimonthly testing did not make them worry more about HIV, and almost all (98%) judged that with bimonthly testing their risk behavior remained the same (77%) or became less risky (21%). CONCLUSION: Bimonthly home specimen collection of both OF and DBS with telephone counseling is acceptable and feasible among study participants at high risk. These methods will be useful for the early detection of HIV infection and remote follow-up of research cohort participants in HIV vaccine and prevention trials.

AIDS Serodiagnosis↗

Field testing and comparative evaluation of rapid, visually read screening assays for antibody to human immunodeficiency virus.

Five rapid, visually read assays for detection of antibody against human immunodeficiency virus (HIV) were evaluated on fresh serum samples from 4000 prospective blood donors at Mama Yemo Hospital, Kinshasa, Zaïre. The sensitivity of the assays, based on 214 specimens positive by western blot, ranged from 84.6% to 99.1%. The specificity, based on 3664 samples negative by enzyme-linked immunosorbent assay (ELISA) or western blot, ranged from 92.7% to 98.8%. Three readers scored each test result independently; disagreement about test interpretation occurred in 1.2-8.3% of the specimens. There was no correlation between assay performance and assay principle (agglutination or dot immunobinding) or antigen source (viral lysate or recombinant). Assays such as these can be readily implemented in a developing country transfusion centre, where blood screening by ELISA is not practicable.

Agglutination Tests↗

Thrombin causes subsecond changes in protein phosphorylation of platelets.

We have developed a general quenched-flow approach to study platelet function as early as 0.3 seconds after stimulation. Phosphorylation of 20- and 40-kd proteins has been analyzed during the first five seconds of platelet response to thrombin from 0.1 to 5.0 U/mL and compared with the progress of aggregation and serotonin secretion. The onset time for aggregation and phosphorylation of both proteins was less than one second, although with lowest (less than 0.5 U/mL) thrombin levels, a lag of up to 0.6 seconds occurred before 40K phosphorylation increased. The thrombin sensitivity of aggregation and 20K phosphorylation was approximately twice that of 40K phosphorylation, with Ka values of 0.51 and 0.53 v 1.10 U/mL, respectively. External calcium was necessary for maximal 20K phosphorylation, since EDTA inhibited this by 30%. The 40K phosphorylation was not affected by EDTA. Platelet activation by thrombin thus induced biochemical changes well before one second. The quenched-flow approach may help to reveal relationships between phospholipase activation, calcium fluxes, and protein phosphorylation during these early periods of platelet function.

Blood Platelets↗