Vasodilatation with felodipine in chronic asymptomatic aortic regurgitation.

BACKGROUND: Afterload reduction decreases volume overload on the left ventricle and may thereby delay the need for valve replacement in chronic asymptomatic aortic regurgitation. The aims of this randomized double-blind, placebo-controlled trial were to examine short- and long-term hemodynamic effects of felodipine in chronic asymptomatic aortic regurgitation. METHODS: Sixteen patients were randomly assigned to an intravenous infusion of either felodipine 0. 3 mg or placebo followed by 3 months' treatment with felodipine 10 mg or placebo orally once daily. Magnetic resonance imaging was performed at baseline, immediately after intravenous treatment, and after 3 months of oral treatment. RESULTS: Intravenous felodipine caused a statistically significant reduction in the systemic vascular resistance from (mean +/- SD) 1160 +/- 400 to 970 +/- 320 dynes. s. cm(-5) (P <.05), in the regurgitant volume index from 1.5 +/- 0.8 to 1.3 +/- 0.8 L. min(-1). m(-2) (P <.05), and in the regurgitant fraction from 0.31 +/- 0.15 to 0.26 +/- 0.14 (P <.05). The forward cardiac output index increased significantly from 3.2 +/- 0.9 to 3.5 +/- 0.7 L. min(-1). m(-2) (P <.05). Three months of oral treatment with felodipine caused a corresponding but more pronounced decrease in systemic vascular resistance of 880 +/- 330 dynes. s. cm(-5) (P <.05), regurgitant volume index of 1.2 +/- 0.7 L. min(-1). m(-2) (P <.05), and regurgitant fraction 0.25 +/- 0.11 (P <.05), whereas the forward cardiac output index increased to 3.6 +/- 0.7 L. min(-1). m(-2) (P <.05). No significant changes were found in the placebo group. Left ventricular volumes and ejection fraction remained unaffected by treatment, but compared with the placebo group left ventricular myocardial mass decreased significantly from 137 +/- 24 to 132 +/- 21 g. m(-2) (P <.01). CONCLUSION: In chronic asymptomatic aortic regurgitation, felodipine causes beneficial hemodynamic effects that may postpone the need for valve replacement.

Adult↗

High-resolution diffusion imaging using phase-corrected segmented echo-planar imaging.

Diffusion magnetic resonance imaging (MRI) was performed with a high-resolution segmented echo-planar imaging technique, which provided images with substantially less susceptibility artifacts than images obtained with single-shot echo-planar imaging (EPI). Diffusion imaging performed with any multishot pulse sequence is inherently sensitive to motion artifacts and in order to reduce motion artifacts, the presented method utilizes navigator echo phase corrections, performed after a one-dimensional Fourier transform along the frequency-encoding direction. Navigator echo phases were fitted to a straight line prior to phase correction to avoid errors from internal motion. In vivo imaging was performed using electro cardiographic (ECG) triggering. Apparent diffusion coefficient (ADC) maps were calculated on a pixel-by-pixel basis using up to seven diffusion sensitivities, ranging from b = 0 to 1129 x 10(6) s/m(2).

Adult↗

Clinical lacunar syndromes as predictors of lacunar infarcts. A comparison of acute clinical lacunar syndromes and findings on diffusion-weighted MRI.

OBJECTIVES: To evaluate if patients with acute lacunar syndromes have acute lacunar infarcts or other types of cerebral lesions on diffusion-weighted MRI. METHODS: Patients with acute lacunar syndromes underwent echo-planar diffusion MRI of the brain within 3 days after stroke onset. Localization and size of lesions with hyperintense signal were determined, compared with clinical characteristics and with findings on follow-up T2-weighted MRI. RESULTS: Twenty-three patients participated in the study. Thirteen patients had pure motor stroke, 1 pure sensory stroke, 8 sensorimotor stroke, and 1 ataxic hemiparesis. Twenty-two patients had at least one lesion with increased signal on diffusion-weighted MR images. These acute lesions were in the internal capsule/ basal ganglia/thalamus in 13 patients, subcortical white matter in 5 patients, brainstem in 2 patients, cortex (multiple small lesions) in 1 patient, and cortex + basal ganglia in 1 patient. The median volume of the lesions was 0.6 ml on the initial examination and on follow-up, of 17 patients after 1 to 5 months, 0.5 ml. CONCLUSIONS: Almost all patients with acute ischemic lacunar syndromes have acute lesions on echo-planar diffusion-weighted MRI within 3 days after stroke onset. These lesions are mostly small and subcortical, compatible with lacunar infarcts caused by single penetrating artery occlusion, but in a minor proportion of patients (2 of 23 in our study) a cortical involvement is found.

Acute Disease↗

Coronary sinus flow measurement by means of velocity-encoded cine MR imaging: validation by using flow probes in dogs.

PURPOSE: To validate coronary sinus flow measurements for quantification of global left ventricular (LV) perfusion by means of velocity-encoded cine (VEC) magnetic resonance (MR) imaging and flow probes. MATERIALS AND METHODS: Measurements of coronary sinus flow were performed in seven dogs by using VEC MR imaging at baseline, single coronary arterial stenosis, dipyridamole stress, and reactive hyperemia. These measurements were compared with flow probe measurements of coronary blood flow (CBF) in the left anterior descending coronary (LAD) and circumflex (CFX) arteries (CBF(LAD+CFX)) and coronary sinus. LV blood perfusion was calculated in milliliters per minute per gram from coronary sinus flow, and LV mass was obtained by using VEC and cine MR imaging. LV mass was validated at autopsy. RESULTS: CBF(LAD+CFX) and coronary sinus flow at VEC MR imaging showed close correlation (r = 0.98, P: <.001). The difference between CBF(LAD+CFX) and MR coronary sinus flow was 3.1 mL/min +/- 8.5 (SD). LV mass at cine MR imaging was not significantly different from that at autopsy (73.2 g +/- 12.8 vs 69. 4 g +/- 12.8). At baseline, myocardial perfusion was 0.40 mL/min/g +/- 0.09 at VEC MR imaging, and CBF(LAD+CFX) was 0.44 mL/min/g +/- 0. 08 (not significant). Reactive hyperemia resulted in 2.7- and 2. 3-fold increases in coronary sinus flow at VEC MR imaging and flow probe CBF(LAD+CFX), respectively. CONCLUSION: VEC MR imaging has the potential to measure coronary sinus flow during different physiologic conditions and can serve as a noninvasive modality to quantify global LV perfusion in patients.

Animals↗

Proton MR spectroscopy and preoperative diagnostic accuracy: an evaluation of intracranial mass lesions characterized by stereotactic biopsy findings.

BACKGROUND AND PURPOSE: MR imaging has made it easier to distinguish among the different types of intracranial mass lesions. Nevertheless, it is sometimes impossible to base a diagnosis solely on clinical and neuroradiologic findings, and, in these cases, biopsy must be performed. The purpose of this study was to evaluate the hypothesis that proton MR spectroscopy is able to improve preoperative diagnostic accuracy in cases of intracranial tumors and may therefore obviate stereotactic biopsy. METHODS: Twenty-six patients with intracranial tumors underwent MR imaging, proton MR spectroscopy, and stereotactic biopsy. MR spectroscopic findings were evaluated for the distribution pattern of pathologic spectra (NAA/Cho ratio < 1) across the lesion and neighboring tissue, for signal ratios in different tumor types, and for their potential to improve preoperative diagnostic accuracy. RESULTS: Gliomas and lymphomas showed pathologic spectra outside the area of contrast enhancement while four nonastrocytic circumscribed tumors (meningioma, pineocytoma, metastasis, and germinoma) showed no pathologic spectra outside the region of enhancement. No significant correlation was found between different tumor types and signal ratios. MR spectroscopy improved diagnostic accuracy by differentiating infiltrative from circumscribed tumors; however, diagnostic accuracy was not improved in terms of differentiating the types of infiltrative or circumscribed lesions. CONCLUSION: MR spectroscopy can improve diagnostic accuracy by differentiating circumscribed brain lesions from histologically infiltrating processes, which may be difficult or impossible solely on the basis of clinical or neuroradiologic findings.

Adult↗

Functional evaluation of extracardiac ventriculopulmonary conduits and of the right ventricle with magnetic resonance imaging and velocity mapping.

Extracardiac ventriculopulmonary conduits tend to deteriorate over time, developing both obstruction and regurgitation. In this prospective study, magnetic resonance imaging (MRI) was compared with Doppler echocardiography to determine whether MRI improves the noninvasive evaluation of conduit patients. Twenty-five patients (median age 10 years, range 2.5 to 32) were investigated 27 times with Doppler echocardiography and an MRI protocol with spin echo sequences for morphology, velocity mapping, and multislice gradient echo technique for right ventricular volume measuring. Cardiac catheterization data were available in 6 patients. Echocardiography could assess the morphology of the conduits in 6 patients, whereas MRI demonstrated all conduits efficiently. Doppler echocardiography could evaluate the occurrence of regurgitation in 18 patients and could quantify peak velocity in 20 of the patients. A technically adequate MRI velocity mapping was obtained in 25 patients. There was good agreement between MRI and Doppler echocardiography in establishing or not establishing regurgitation, but Doppler echocardiography was less reliable in evaluating the degree of regurgitation. The correlation between peak velocity determined with Doppler and magnetic resonance imaging was r = 0.63 [corrected]. Correlations between catheterization pressure gradients and noninvasive techniques were r = 0.97 for magnetic resonance imaging [corrected] versus catheterization, and r = 0.86 [corrected] for Doppler versus catheterization. MRI can provide complete information on the morphology and function of extracardiac ventriculopulmonary conduits, as well as of the right ventricle. If the results of MRI and echocardiography with Doppler are in agreement, heart catheterization and angiography can be avoided, even in patients considered for conduit replacement.

Adolescent↗

Magnetic resonance imaging of valvular heart disease.

The optimum management of patients with valvular heart diseases requires accurate and reproducible assessment of the valvular lesion and its hemodynamic consequences. Magnetic resonance imaging (MRI) techniques, such as volume measurements, signal-void phenomena, and velocity mapping, can be used in an integrated approach to gain qualitative and quantitative information on valvular heart disease as well as ventricular dimensions and functions. Thus, MRI may be advantageous to the established diagnostic tools in assessing the severity of valvular heart disease as well as monitoring the lesion and predicting the optimal timing for valvular surgery. This paper reviews the validation of these MRI techniques in assessing valvular heart disease and discusses some typical pitfalls of the techniques, including suggestions for solutions.J. Magn. Reson. Imaging 1999;10:627-638.

Blood Flow Velocity↗

Image artifacts due to a time-varying contrast medium concentration in 3D contrast-enhanced MRA.

The purpose of this work was to study image effects due to time-varying contrast medium concentration in contrast-enhanced three dimensional (3D) magnetic resonance angiography (MRA) images. Two different simulation models (1D and 3D) and two different contrast medium variation schemes were used. Phantom measurements were also performed. Experiments were performed for several different bolus timings. Similar sequence and image object parameters were used in both simulations and measurements (TE/TR 2. 1/7.8 mses, flip angle 30 degrees, T1/T2 1200-80/150-40 msec, flow velocity 100 cm/sec). A small variation in bolus timing yielded large variations in the appearance of the image effects, especially if the center of k-space was sampled in the vicinity of rapid contrast medium concentration variation. For a typical bolus injection in a patient, a severe signal loss but only minor ringing and edge artifacts appeared if the bolus injection was poorly timed. Effects of pulsatile flow were minor. The 3D model proved to be a useful tool in these studies. J. Magn. Reson. Imaging 1999;10:919-928.

Aorta↗

Quality assessment of localization technique performance in small volume in vivo 1H MR spectroscopy.

A new phantom and evaluation method for experimental evaluation of 1H-magnetic resonance spectroscopy single volume localization techniques regarding signal contamination (C), defined as the part of the signal originating outside the volume of interest, is presented. The quality assessment method is based on a spherical phantom with an oil/water interface in order to reduce susceptibility effects, and applied for stimulated-echo acquisition method (STEAM) and spin-echo (SE) sequences, echo times of 270, 135, and 10 ms, and cubic volumes of interest (VOI) of 1(3), 1.5(3), 2(3), 2.5(3), and 3(3) cm3. To be able to mimic measurements of the contamination in three dimensions the physical gradients representing the three orthogonal directions for slice selection were shifted in the pulse sequences. Contamination values in one dimension differed between 6.5% and 8.4% in SE sequences, and between 0.7% and 13.8% in STEAM sequences. In STEAM sequences a decrease of C with increasing VOI size was observed while SE sequences showed comparable C values for the different VOI sizes tested. The total contamination in three dimensions were 19% and 18% in SE and STEAM sequences with a TE of 270 ms, and 7% in a STEAM sequence with a TE of 10 ms, respectively. The presented evaluation method is easily applied to the new phantom and showed high reproducibility.

Artifacts↗

Left-to-right cardiac shunts: comparison of measurements obtained with MR velocity mapping and with radionuclide angiography.

PURPOSE: To investigate the agreement between two noninvasive methods, magnetic resonance (MR) velocity mapping and first-pass radionuclide angiography, to quantify the pulmonary-to-systemic blood flow ratio (QP/QS) in adults, adolescents, and children with left-to-right cardiac shunts. MATERIALS AND METHODS: The accuracy and precision of MR velocity mapping were studied in 12 control subjects (six men, six women) and in a phantom. MR velocity mapping and radionuclide angiography were performed on the same day in 24 patients (16 adults, two adolescents, six children; five male patients, 19 female patients). RESULTS: The mean error in QP/QS at MR velocity mapping in phantom experiments was -1% +/- 1 (mean +/- SD). In control subjects, QP/QS at MR velocity mapping was 1.03 +/- 0.03, and the cardiac index was 3.1 L/min/m2 +/- 0.2 and 3.2 L/min/m2 +/- 0.3 for women and men, respectively. In patients, QP/QS at radionuclide angiography was 14% +/- 13, higher than at MR velocity mapping. Interobserver variability was four times higher for radionuclide angiography compared with MR velocity mapping, 0% + 16 versus 0% +/- 4 (n = 12). The difference between repeated MR flow measurements in the same vessel was -1% +/- 5 (n = 36). CONCLUSION: The data suggest that MR velocity mapping is accurate and precise for measurements of shunt size over the whole range of possible QP/QS values.

Adolescent↗

Radiological diagnosis of acute stroke. Comparison of conventional MR imaging, echo-planar diffusion-weighted imaging, and spin-echo diffusion-weighted imaging.

PURPOSE: To compare conventional MR imaging, echo-planar diffusion-weighted imaging (EP-DWI) and spin-echo diffusion-weighted imaging (SE)-DWI at radiological diagnosis of acute stroke. MATERIAL AND METHODS: Twenty-seven patients (30-85 years old) were examined. Clinical examination was performed before MR imaging. All MR examinations were assessed by an experienced neuroradiologist blinded to clinical findings. RESULTS: In EP-DWI, every patient had a lesion corresponding to the clinical findings. EP-DWI was used as the gold standard. In conventional PD+T2 imaging, 23/59 focal lesions were interpreted as acute, which was false in 11 lesions, and 36/59 lesions were considered to be old, 6 were in fact acute. Nine acute lesions were only detected retrospectively and 12 acute lesions were not detected at all on PD+T2. SE-DWI including the apparent diffusion coefficient correlated fairly well with EP-DWI but the procedure was impractical. CONCLUSION: EP-DWI is reliable for diagnosis of early ischemic stroke, while SE-DWI performs reasonably well. Conventional PD+T2 imaging is not reliable for diagnosis of early ischemia.

Acute Disease↗

Triggering in quantitative diffusion imaging with single-shot EPI.

PURPOSE: The aim of this study was to evaluate any possible effects of brain motion, CSF pulsations and other possible sources of physiological motion in electrocardiographic (ECG) triggered and non-triggered single-shot echo-planar imaging (EPI) measurements of diffusion. MATERIAL AND METHODS: Three different triggering protocols were evaluated in 6 healthy volunteers: 1) ECG triggering with time delay (TD) 100 ms; 2) ECG triggering with TD 400 ms; and 3) no triggering at all. RESULTS: The results obtained showed that white matter mean apparent diffusion coefficient (ADC) values were similar for all triggering protocols and that the reproducibility in ADC measurements using diffusion-weighted (DW) EPI was good. The average standard deviation of the ADC values was, however, higher for ADC maps obtained without ECG triggering. CONCLUSION: The use of prospective diastolic ECG triggering significantly improves the accuracy of quantitative diffusion measurements but for routine clinical diffusion imaging, where quantitative data is of less importance, the accuracy obtained without ECG triggering can be considered adequate.

Adult↗

Quantitative diffusion coefficient maps using fast spin-echo MRI.

In this work, we have evaluated the performance of a diffusion-sensitive fast spin-echo (FSE) pulse sequence. The proposed pulse sequence utilises velocity-compensating diffusion-encoding gradients and includes the collection of navigator echoes. Spoiler gradients were inserted in the slice-selecting direction to minimise effects from stimulated echoes. Calculations of the b values showed that cross-terms between imaging gradients and diffusion gradients only led to a marginal increase of b values. Pixel-wise calculation of apparent diffusion coefficient (ADC) maps was performed numerically, considering cross-terms between diffusion-encoding and imaging gradients. The sequences investigated used echo train lengths of 16, 8 and 4 echoes and were encoded in either the slice-, frequency- or phase-encoding direction. In order to allow for higher b values a pulse-sequence version using non-motion compensating diffusion-encoding gradients was written. Phantom measurements were performed and the diffusion coefficients of water and acetone were reasonable. Seven healthy volunteers (age 28-50 years) were examined and apparent diffusion coefficient values agreed well with expected values. Diffusion-weighted images, apparent diffusion coefficient maps and images corresponding to the trace of the diffusion tensor of good quality were retrieved in vivo.

Adult↗

Aneurysm clip MR artifacts. Titanium versus stainless steel and influence of imaging parameters.

PURPOSE: The aim of this study was to evaluate the extent to which titanium aneurysm clips could improve the quality of MR imaging compared with stainless steel clips, and to determine whether the clip artifacts could be reduced by controlling certain MR imaging parameters in frequently used pulse sequences. MATERIAL AND METHODS: The metal artifacts induced by 3 aneurysm clips were compared in 3 pulse sequences. The clips were: a Yasargil titanium aneurysm clip FT 752 T; a Yasargil standard aneurysm clip FE 752 K; and, for comparison, a ferromagnetic Scoville aneurysm clip En-58J. The pulse sequences were: spin echo (SE); gradient echo (GE); and fast SE. An evaluation was made of 3 imaging parameters with regard to their influence on the size of the metal artifacts. The parameters were: bandwidth; echo time (TE); and echo-train length. RESULTS: The titanium clip showed artifacts that were about 60% smaller than those from the stainless steel clip. The only parameter that influenced artifact size to any major degree was bandwidth in the SE sequences but not in the GE sequences. GE sequences induced larger artifacts than SE sequences and showed larger artifacts with longer TE. CONCLUSION: Titanium aneurysm clips reduced MR artifacts by approximately 60% compared to stainless steel clips. Artifacts were further reduced by using SE-based sequences with a high bandwidth or, if necessary, GE sequences with a low TE.

Artifacts↗

A two-compartment phantom for VOI profile measurements in small-bore 31P MR spectroscopy.

A two-compartment gel phantom for VOI profile measurements in volume-selective 31P spectroscopy in small-bore units is presented. The phantom is cylindrical with two compartments divided by a very thin (30 microm) polyethene film. This thin film permits measurements with a minimum of susceptibility influences from the partition wall. The phantom was used for evaluation of the volume selection method ISIS (image-selected in vivo spectroscopy). The position of the phantom was fixed in the magnet during the measurements, while the volume of interest (VOI) was moved stepwise over the border. The signal from the two compartments was measured for each position and the data were evaluated following differentiation. We have found this phantom suitable for VOI profile measurements of ISIS in small-bore systems. The phantom forms a useful complement to recommended phantoms for small bore-spectroscopy.

Biophysical Phenomena↗

MRI thermometry in phantoms by use of the proton resonance frequency shift method: application to interstitial laser thermotherapy.

In this work the temperature dependence of the proton resonance frequency was assessed in agarose gel with a high melting temperature (95 degrees C) and in porcine liver in vitro at temperatures relevant to thermotherapy (25-80 degrees C). Furthermore, an optically tissue-like agarose gel phantom was developed and evaluated for use in MRI. The phantom was used to visualize temperature distributions from a diffusing laser fibre by means of the proton resonance frequency shift method. An approximately linear relationship (0.0085 ppm degrees C(-1)) between proton resonance frequency shift and temperature change was found for agarose gel, whereas deviations from a linear relationship were observed for porcine liver. The optically tissue-like agarose gel allowed reliable MRI temperature monitoring, and the MR relaxation times (T1 and T2) and the optical properties were found to be independently alterable. Temperature distributions around a diffusing laser fibre, during irradiation and subsequent cooling, were assessed with high spatial resolution (voxel size = 4.3 mm3) and with random uncertainties ranging from 0.3 degrees C to 1.4 degrees C (1 SD) with a 40 s scan time.

Animals↗