PubMed Health⌕ Search

Biomedical subjects

F Stuart Foster

Publications and source records attributed to F Stuart Foster.

32 records · Page 2Linked to original sources

Effects of aggregation of red cells and linear velocity gradients on the correlation-based method for quantitative IVUS blood flow at 20 MHz.

Recent computer simulations suggest that the presence of aggregates of red blood cells (RBCs), at random angles and lengths, does not affect the measurements of blood flow transverse to the ultrasound (US) beam direction using a correlation-based method and an intravascular (IV) US array catheter. However, in case of aggregates of RBCs aligned with the flow, measurements of simulated blood velocity are affected. Blood velocity gradients were also shown not to influence the correlation-based method for blood velocity estimation. The objective of this study was to quantify the influence of aggregates of RBCs and blood velocity gradients on the correlation-based method during in vitro experiments. For this purpose, measurements were performed on washed RBCs (no aggregation), normal human blood, and two types of diseased blood in which a lower or a higher level of aggregation was present. The decorrelation pattern of a circular US transducer as a function of transverse blood flow was studied using a Couette system. Changing the shear rate of the Couette system modified the aggregation level of RBCs and the velocity gradient. With the exception of the results at low shear rates and abnormally high aggregation levels, agreements were found between the autoconvolution of the acoustical beam (reference curve) and the radiofrequency (RF) decorrelation patterns. For the high shear rate present in coronary arteries, the correlation-based method for blood flow estimation should not be influenced by these phenomena.

Adult↗

Thermal assessment of 40-MHz ultrasound at soft tissue-bone interfaces.

Tissue exposure to diagnostic ultrasound (US) can cause significant temperature rises. However, little has been reported on thermal effects of high-frequency US, and guidelines for the use of US do not necessarily apply to higher frequencies. Temperature rise induced by US biomicroscopy (UBM) was measured in phantoms containing mouse skulls and in anesthetized mice and mice post mortem, with a 50-microm K-type thermocouple. The operating frequency was 40 MHz with a free field I(SPTA) of 2.6 mW/cm(2) (B-mode) and 11.9 W/cm(2) (Doppler). Peak negative pressures were 5.22 MPa (B mode) and 7.32 MPa (Doppler), resulting in a mechanical index (MI) of 0.83 (B-mode) and 1.05 (Doppler mode). In Doppler mode, mean temperature rises of 1.80 degrees C and 1.73 degrees C were measured for proximal and distal skull phantom surfaces after a 3-min insonation. In vivo, the proximal mouse skull surface showed a mean temperature rise of 2.1 degrees C, with no statistically significant differences post mortem. Our results indicate temperature rise from insonation of bone interfaces using similar exposure parameters should not cause adverse bioeffects.

Animals↗

Developmental changes in integrated ultrasound backscatter from embryonic blood in vivo in mice at high US frequency.

Mouse blood imaged using high-frequency ultrasound (US) is more echogenic in embryos than in adults. Studying changes in blood echogenicity in embryos may be of fundamental interest in studies on the genetic regulation of normal and abnormal blood development in mutant mice. Embryonic red blood cells (RBCs) are large and nucleated in midgestation but decrease in size and become enucleated as they mature. We therefore hypothesised that these structural alterations are responsible for variations in echogenicity of embryonic blood with gestational age and development. The objective of the current study was to quantify these structural changes in echogenicity (echo brightness) and apparent integrated backscatter (AIB) from embryonic blood at high US frequencies in vivo in mice. Results from anaesthetised pregnant mice studied using transcutaneous US showed that echogenicity of embryonic blood in the heart, aorta and umbilical cord and AIB within the heart chambers peaked at embryonic day (ED) 13.5 and then decreased progressively toward term. Between EDs 13.5 and 17.5 (near term), RBC mean cell volume decreased from 133 to 109 fL, haematocrit increased from 12 to 34%, and the percentage of nucleated RBCs decreased from 59 to 2%. Relative to younger ages, RBC nuclei at ED 13.5 were small and dense (pyknotic) which may have contributed to the peak in echogenicity and AIB at this age. To calculate the AIB, radiofrequency (RF) signals with centre frequencies of 28 MHz and 35 MHz were integrated over the 16- to 35-MHz and 21- to 42-MHz frequency range, respectively. At 28 MHz, mean apparent integrated backscatter of blood in the embryonic heart increased significantly from 0.0023 +/- 0.0004 Sr.cm(-1) (mean +/- SEM) at ED 12.5 to peak at 0.0037 +/- 0.0005 Sr.cm(-1) at ED 13.5. The mean AIB then decreased progressively with advancing gestation to 0.0002 +/- 0.0001 Sr.cm(-1) at ED 17.5. At 35 MHz, the mean AIB changed similarly with gestational age, except that values were lower than at 28 MHz at all ages. Higher attenuation of US at 35 MHz than at 28 MHz in tissue likely accounted for the lower AIB of blood insonified at 35 MHz. We speculate that developmental changes in red cell morphology are responsible for the observed changes in echogenicity and AIB of embryonic blood with gestational age in mice.

Animals↗

Biological effects of high-frequency ultrasound exposure during mouse organogenesis.

Little has been reported on bioeffects of high-frequency ultrasound (US) and guidelines for US use do not necessarily apply to high frequencies. Pregnant CD-1 mice were exposed to Doppler or B-mode US biomicroscopy (UBM) on embryonic day (E) 8.5 or E10.5, during organogenesis. Operating frequency was 40 MHz with a free field I(SPTA) of 11.9 W/cm(2) (Doppler) and 2.6 mW/cm(2) (B-mode), peak negative pressures of 6.61 MPa and MI of 1.05 (B-mode). Offspring were assessed weekly from 1 day postnatally to euthanasia at 6 weeks, with no significant difference in pup weight, body length or crown-rump length observed. E8.5 Doppler-exposed mice showed a small reduction in weight and length at 3 weeks and in weight at 6 weeks. E10.5 Doppler-exposed animals exhibited slight growth reduction in weeks 2 to 4, but were not significantly different at 6 weeks. Our results indicate similar exposures of mice should not cause significant adverse bioeffects.

Animals↗

Ultrasound-guided left-ventricular catheterization: a novel method of whole mouse perfusion for microimaging.

We describe a novel technique to perform whole-body perfusion fixation in mice with specific relevance to micro-imaging. With the guidance of high-frequency ultrasound imaging, we were able to perfuse fixative and contrast agents via a catheter inserted into the left ventricle, and therefore preserved the integrity of the chest and abdominal cavity. In this preliminary study, our success rate over 15 animals was 73%. We demonstrate applications of this technique for magnetic resonance imaging and micro-CT, but we expect that this method can be generally applied to whole-body perfusions of other small animals in which the intact body is necessary.

Animals↗

Non-Gaussian statistics and temporal variations of the ultrasound signal backscattered by blood at frequencies between 10 and 58 MHz.

Very little is known about the blood backscattering behavior and signal statistics following flow stoppage at frequencies higher than 10 MHz. Measurements of the radio frequency (rf) signals backscattered by normal human blood (hematocrit = 40%, temperature = 37 degrees C) were performed in a tube flow model at mean frequencies varying between 10 and 58 MHz. The range of increase of the backscattered power during red blood cell (RBC) rouleau formation was close to 15 dB at 10 and 36 MHz, and dropped, for the same blood samples, below 8 dB at 58 MHz. Increasing the frequency from 10 to 58 MHz raised the slope of the power changes at the beginning of the kinetics of aggregation, and could emphasize the non-Gaussian behavior of the rf signals interpreted in terms of the K and Nakagami statistical models. At 36 and 58 MHz, significant increases of the kurtosis coefficient, and significant reductions of the Nakagami parameter were noted during the first 30 s of flow stoppage. In conclusion, increasing the transducer frequency reduced the magnitude of the backscattered power changes attributed to the phenomenon of RBC aggregation, but improved the detection of rapid growth in aggregate sizes and non-Gaussian statistical behavior.

Acoustics↗

Developmental changes in left and right ventricular diastolic filling patterns in mice.

Developmental changes in left and right ventricular diastolic filling patterns were determined noninvasively in isoflurane-anesthetized outbred ICR mice. Blood velocities in the mitral and tricuspid orifices were recorded in 16 embryos at days 14.5 (E14.5) and 17.5 of gestation (E17.5) using an ultrasound biomicroscope and also serially in three groups of postnatal mice aged 1-7 days (n = 23), 1-4 wk (n = 18), and 4-12 wk (n = 27) using 20-MHz pulsed Doppler. Postnatal body weight increased rapidly to 8 wk. Heart rate increased rapidly from approximately 180 beats/min at E14.5 to approximately 380 beats/min at 1 wk after birth and then more gradually to plateau at approximately 450 beats/min after 4 wk. Ventricular filling was quantified using the ratio of peak velocity of early ventricular filling due to active relaxation (E wave) to that of the late ventricular filling caused by atrial contraction (A wave) (peak E/A ratio) and the ratio of the peak E velocity to total time-velocity integral of E and A waves (peak E/total TVI ratio). Both ventricles had similar diastolic filling patterns in embryos (peak E/A ratio of 0.28 +/- 0.02 for mitral flow and 0.27 +/- 0.02 for tricuspid flow at E14.5). After birth, mitral peak E/A increased to >1 between the third and fifth day, continued to increase to 2.25 +/- 0.25 at approximately 3 wk, and then remained stable. The tricuspid peak E/A ratio increased much less but stabilized at the same age (increased to 0.79 +/- 0.03 at 3 wk). The peak E/total TVI ratio showed similar left-right differences and changes with development. Age-related changes were largely due to increases in peak E velocity. The results suggest that diastolic function matures approximately 3 wk postnatally, presumably in association with maturation of ventricular recoil and relaxation mechanisms.

Anesthesia↗

Dynamic measurement of internal solid displacement in articular cartilage using ultrasound backscatter.

Mechanics of articular cartilage can be represented using poroelastic theories where fluid and solid displacements are viscously coupled to create a time-dependent spatially heterogeneous behavior. In recent models of this tissue, finite element methods have been used to predict tissue deformation as a function of time for adult articular cartilage bearing a characteristic depth-dependent structure and composition. However, current experimental methods are limited in providing verification of these predictions. The current study presents an apparatus for imaging the radial displacement profile of cartilage in unconfined compression using an ultrasound technique called elastography. We acquired ultrasound A-scans across the lateral diameter of full-thickness cartilage disks containing a thin layer of underlying bone, during axial compression. Elastography was then applied to correlate temporally sequential A-scans to estimate the solid radial displacement profile in articular cartilage while it undergoes compression and stress-relaxation. Both time-dependent and depth-dependent solid radial displacement profiles were obtained with a precision better than 0.2 micro The results generally agree with predictions of poroelastic models, demonstrating lateral expansion with an effective Poisson's ratio just after completion of the compression phase of the mechanical tests reaching values from 0.18 to 0.4 (depending on compression speed), followed by contraction to lower values. A more restricted movement was observed at both the articular surface and near to the subchondral bone than at regions midway between these two locations.

Animals↗

High-frequency 3-D color-flow imaging of the microcirculation.

High-frequency (> 20 MHz) ultrasound (US) flow imaging has the potential to be an important tool for assessing microvascular blood flow in superficial tissues noninvasively. In this paper, we describe the development and evaluation of a 3-D US flow imaging system capable of operating at center frequencies in the 20- to 50-MHz range. Flow images are made for tissue volumes of sizes up to 10 mm laterally and 5 mm in depth, permitting a range of scientific and clinical applications. To acquire data sets in a reasonable time, the 2-D sections were derived from data collected with a transducer that was scanning continuously in a direction perpendicular to the beam axis. Due to spectral broadening effects induced by scanning tissue, significant tradeoffs must be made between frame rate, lateral resolution and the minimum detectable blood velocity. 3-D flow images were reconstructed with flow data acquired from a series of adjacent planes. The system was evaluated at a center frequency of 50 MHz, using two PVDF transducers with lateral resolutions of 43 microm and 65 microm and axial resolutions of 66 microm to 72 microm, respectively. Velocity ranges were from below 1 mm/s to 25 mm/s. In vivo validation experiments using the mouse ear demonstrated the ability to follow branching patterns of closely spaced microvessels from 30 microm to 100 microm in diameter. Experiments conducted on mouse tumors successfully imaged microvessel morphology in the tumor microcirculation.

Animals↗

Multifrequency ultrasound transducers for conformal interstitial thermal therapy.

Control over the pattern of thermal damage generated by interstitial ultrasound heating applicators can be enhanced by changing the ultrasound frequency during heating. The ability to change transmission frequency from a single transducer through the use of high impedance front layers was investigated in this study. The transmission spectrum of multifrequency transducers was calculated using the KLM equivalent circuit model and verified with experimental measurements on prototype transducers. The addition of a quarter-wavelength thick PZT (unpoled) front layer enabled the transmission of ultrasound at two discrete frequencies, 4.7 and 9.7 MHz, from a transducer with an original resonant frequency of 8.4 MHz. Three frequency transmission at 3.3, 8.4, and 10.8 MHz was possible for a transducer with a half-wavelength thick front layer. Calculations of the predicted thermal lesion size at each transmission frequency indicated that the depth of thermal lesion could be varied by a factor of 1.6 for the quarter-wavelength front layer. Heating experiments performed in excised liver tissue with a dual-frequency applicator confirmed this ability to control the shape of thermal lesions during heating to generate a desired geometry. Practical interstitial designs that enable the generation of shaped thermal lesions are feasible.

Animals↗

Ultrasound characterization of coronary artery wall in vitro using temperature-dependent wave speed.

Temperature dependence of the speed of sound, partial partial differential c/partial partial differential T, is examined as a parameter to characterize tissue-equivalent phantoms and coronary artery tissue in vitro. The experimental system comprises an ultrasound biomicroscope, operating at center frequency of 50 MHz, and a temperature controlled micropositioning sample cell. Radio frequency (RF) backscattered signals were recorded, with a digital oscilloscope, from 64 independent positions and at 5 temperatures starting at 31 degrees C (phantom) and 36 degrees C (tissue) in steps of one degree. Time shift per degree Celsius (delta t/delta T) was obtained with a correlation technique applied between gated sections of two RF-signals collected with one degree temperature difference from the same location in the sample. The average (delta t/delta T), calculated for every position of the gated sections along the propagation axis of the ultrasound beam, has the slope proportional to the difference between the linear coefficient of thermal expansion and the thermal sensitivity of the speed of sound. Calibration measurements of partial partial differential c/partial partial differential T, made with single- and three-layer tissue equivalent phantoms, correlated well (r > or = 0.91) with those measured by the time-of-flight substitution method. The partial partial differential c/partial partial differential T was estimated for the three layers on the wall of eight samples of human coronary arteries, obtained at autopsy from four individuals. The partial partial differential c/partial partial differential T for the intima layers decreases as the disease progresses from mild intimal thickening to a more advanced atherosclerosis.

Adult↗

In vivo imaging of embryonic development in the mouse eye by ultrasound biomicroscopy.

PURPOSE: New imaging tools now provide an unprecedented opportunity to visualize anatomic and functional development of the mouse eye. In this study, normal embryonic development of the mouse eye was studied by ultrasound biomicroscopy (UBM), with a focus on the formation of the retina, lens, and cornea. METHODS: The growth of 65 embryonic eyes from timed-pregnant CD-1 mice was examined at various stages of development between embryonic day (E)11.5 and E18.5, using 40-MHz UBM. RESULTS: The morphogenesis of ocular tissues including the lens, retina, and orbit were revealed from the earliest stages of development. The major axis of the CD-1 lens grows at a rate of 68 micro m/d, whereas that of the globe grows at a rate of 122 microm/d, with a concomitant exponential increase in volume. CONCLUSIONS: UBM allows noninvasive assessment of ocular morphogenesis in vivo and can be used to calculate relative growth rates of ocular structures.

Animals↗

High-frequency Doppler ultrasound monitors the effects of antivascular therapy on tumor blood flow.

The effect of antivascular therapy on blood flow in superficial tumors was monitored using novel high frequency Doppler (HFD) ultrasound techniques. Human melanoma cells (MeWo) were injected orthotopically into the skin of athymic nude mice. Volumetric HFD imaging of established melanomas detected a significant reduction in blood flow 4 h after injection of the tumor vascular targeting agent ZD6126 followed by a recovery of flow by 24 h after injection. Measurements of tumor perfusion in situ by Hoechst 33342 staining correlated with the ultrasound results. This study demonstrates the feasibility of HFD as a noninvasive, quantitative tool for following longitudinally the effects of antivascular therapy on blood flow in superficial tumors.

Angiogenesis Inhibitors↗

Experimental characterization of fundamental and second harmonic beams for a high-frequency ultrasound transducer.

In the diagnostic frequency range, nonlinear imaging has been shown to improve image contrast and decrease artefacts. The extension of these techniques to high-frequency imaging (>15 MHz) was investigated. The second harmonic beam at 40 MHz of a high-frequency focused transducer (aperture 6 mm, focal distance 10 mm, f-number 1.67) was measured experimentally in water, in transmission and pulse-echo, and compared with the fundamental beams at 20 MHz and 40 MHz. Measurements were performed at peak negative pressures of 0.8 to 4.7 MPa. Transmission measurements were performed with a custom hydrophone with a 25microm spot size to limit beam averaging. Over the range of peak negative pressures, the transmitted harmonic (40 MHz) beam had an average lateral beam width (-3 dB) of 77 microm and an average depth-of-field of 0.93 mm, whereas the fundamental beam had a corresponding beam width of 137 microm and a depth-of-field of 1.59 mm. The harmonic beam showed a 3-dB decrease in side lobe levels. Preliminary second harmonic images of mouse tissue in vitro are presented and compared to fundamental imaging at 20 and 40 MHz.

Animals↗