PubMed Health⌕ Search

Biomedical subjects

F T Lee

Publications and source records attributed to F T Lee.

At least 19 recordsLinked to original sources

A phase I radioimmunolocalization trial of humanized monoclonal antibody huA33 in patients with gastric carcinoma.

In order to determine the in vivo characteristics of huA33, an open label dose escalation biopsy-based phase I clinical trial and radioimmunolocalization study were conducted with a complement determinant region-grafted humanized monoclonal antibody against the A33 antigen in patients with gastric carcinoma. Thirteen patients were entered onto one of four dose levels (1.0, 2.0, 5.0 or 10.0 mg/m(2)). Patients with locally advanced (UICC-TNM [International Union Against Cancer-tumor, node, metastasis] stage over 2 but resectable at clinical diagnosis) gastric carcinoma received a single infusion of (131)I-huA33 1 week prior to surgery. Adverse events were monitored, and imaging studies with gamma camera plus ex vivo scintigraphy of the resected specimen, biodistribution study by dosimetry analysis of the biopsied and resected tissues, and immunohistochemical analysis were carried out and evaluated. No dose-limiting toxicity was observed during the trial. Therefore, the maximum tolerated dose was not reached. Although cancer tissues with + intensity and <25% extent by immunostaining in biopsied frozen sections did not show positive imaging or postoperative dosimetry findings, cancers with ++ or +++ intensity or wide (>25%) extent by frozen and paraffin sections in the biopsied specimen showed positive ex vivo tumor images and positive antigen expression in resected gastric cancer specimens, and the biodistribution analysis showed tumor uptake of (131)I-huA33. In conclusion, humanized monoclonal antibody huA33 demonstrated selective localization to gastric cancer that expressed A33 antigen strongly. These excellent targeting characteristics of huA33 indicate potential for targeted therapy of advanced gastric cancer that is refractory to cytotoxic therapy, and could also be exploitable for curatively resected early gastric cancer in an adjuvant setting.

Aged↗

Multiple applicator approaches for radiofrequency and microwave ablation.

Treatment of tumours greater than 2 cm by radiofrequency (RF) or microwave ablation typically use multiple sequential applications, since most currently available ablation devices are limited to use of a single applicator at a time. A major focus of current ablation research is on methodologies that allow increasing the coagulation zone to more rapidly treat large tumours. The ability to use multiple applicators simultaneously would satisfy this need. It would significantly reduce treatment time and may lead to a reduction in local tumour progression, especially in perivascular locations. Several methods have been suggested that potentially allow simultaneous use of multiple applicators, both with radiofrequency (RF) and microwave (MW) ablation. This review compares the different methods of multiple applicator use, investigating advantages and disadvantages of each modality.

Catheter Ablation↗

Hepatic bipolar radiofrequency ablation creates coagulation zones close to blood vessels: a finite element study.

Radiofrequency (RF) ablation has become an important means of treatment of non-resectable primary and metastatic liver tumours. Recurrence of treated tumours is associated with cancer cell survival next to blood vessels. The paper examines the performance of classical monopolar, and two configurations of bipolar, RF ablation using a LeVeen ten-prong catheter. Finite element method models of monopolar and bipolar configurations were created at 5 mm distance from a vessel of the size of a typical portal vein (10 mm diameter). In one bipolar configuration, the probes were oriented in the same axial direction (asymmetric configuration); in the second bipolar configuration, the two probes were facing each other (symmetric configuration). The distribution of temperature and current density was analysed for three different flow conditions: normal flow, reduced flow due to portal hypertension and high flow. For normal flow, the distance between the formed coagulation zone and the blood vessel was 1.8 mm for monopolar, 1 mm for asymmetric bipolar, and 0.2 mm for symmetric bipolar, configurations. Symmetric bipolar RF ablation creates coagulation zones significantly closer to blood vessels compared with monopolar RF ablation. This may reduce tumour cell survival next to blood vessels and reduce recurrence rates.

Catheter Ablation↗

Ultrasound monitoring of temperature change during radiofrequency ablation: preliminary in-vivo results.

Radiofrequency (RF) ablation is an interstitial focal ablative therapy that can be used in a percutaneous fashion and permits in situ destruction of hepatic tumors. However, local tumor recurrence rates after RF ablative therapy are as high as 34% to 55%, which may be due in part to the inability to monitor accurately temperature profiles in the tissue being ablated, and to visualize the subsequent zone of necrosis (thermal lesion) formed. The goal of the work described in this paper was to investigate methods for the real-time and in vivo monitoring of the spatial distribution of heating and temperature elevation to achieve better control of the degree of tissue damage during RF ablation therapy. Temperature estimates are obtained using a cross-correlation algorithm applied to RF ultrasound (US) echo signal data acquired at discrete intervals during heating. These temperature maps were used to display the initial temperature rise and to continuously update a thermal map of the treated region. Temperature monitoring is currently performed using thermosensors on the prongs (tines) of the RF ablation probe. However, monitoring the spatial distribution of heating is necessary to control the degree of tissue damage produced.

Animals↗

Specific targeting, biodistribution, and lack of immunogenicity of chimeric anti-GD3 monoclonal antibody KM871 in patients with metastatic melanoma: results of a phase I trial.

PURPOSE: KM871 is a chimeric monoclonal antibody against the ganglioside antigen GD3, which is highly expressed on melanoma cells. We conducted an open-label, dose escalation phase I trial of KM871 in patients with metastatic melanoma. PATIENTS AND METHODS: Seventeen patients were entered onto one of five dose levels (1, 5, 10, 20, and 40 mg/m2). Patients received three infusions of KM871 at 2-week intervals, with the first infusion of KM871 trace-labeled with indium-111 (111In) to enable assessment of biodistribution in vivo. Biopsies of metastatic melanoma sites were performed on days 7 to 10. RESULTS: Fifteen of 17 patients completed a cycle of three infusions of KM871. No dose-limiting toxicity was observed during the trial; the maximum-tolerated dose was therefore not reached. Three patients (at the 1-, 5-, and 40-mg/m2 dose levels) developed pain and/or erythema at tumor sites consistent with an inflammatory response. No normal tissue uptake of 111In-KM871 was observed, and tumor uptake of 111In-KM871 was observed in all lesions greater than 1.5 cm (tumor biopsy 111KM871 uptake results: range, 0.001% to 0.026% injected dose/g). The ratio of maximum tumor to normal tissue was 15:1. Pharmacokinetic analysis revealed a 111In-KM871 terminal half-life of 7.68 +/- 2.94 days. One patient had a clinical partial response that lasted 11 months. There was no serologic evidence of human antichimeric antibody in any patient, including one patient who received 16 infusions over a 12-month period. CONCLUSION: This study is the first to demonstrate the biodistribution and specific targeting of an anti-GD3 antibody to metastatic melanoma in patients. The long half-life and lack of immunogenicity of KM871 makes this antibody an attractive potential therapy for patients with metastatic melanoma.

Adult↗

Specific localization, gamma camera imaging, and intracellular trafficking of radiolabelled chimeric anti-G(D3) ganglioside monoclonal antibody KM871 in SK-MEL-28 melanoma xenografts.

The chimeric monoclonal antibody KM871, directed against the G(D3) antigen, is under evaluation for its potential to target melanoma. To facilitate the in vivo evaluation of biodistribution properties and measurement of pharmacokinetics, KM871 was radiolabeled with (125)I via tyrosine residues and with (111)In via the bifunctional metal ion chelator C-functionalized trans-cyclohexyl diethylenetriaminepentaacetic acid (CHX-A"-DTPA) to lysine residues. Using antigen-positive SK-MEL-28 melanoma cells, immunoreactivities of 42 and 40% cell binding were obtained, respectively, for the two radioconjugates. Binding was enhanced in the presence of added unlabeled antibody. A humanized A33 antibody was similarly labeled with the two isotopes and used as a control. To determine and compare in vivo biodistribution characteristics of KM871 radiolabeled with (111)In or (125)I, mixtures of the radioconjugates were injected i.v. into BALB/c nude mice bearing G(D3)-positive-SK-MEL-28 melanoma xenografts. Gamma camera images were acquired; groups of five mice were sacrificed at various time intervals, and tumors, blood, and tissues were analyzed. (111)In-labeled CHX-A"-DTPA-KM871 showed a maximum tumor uptake of 41.9 +/- 7.0% injected dose/g at 72 h with prolonged retention over a 15-day period. The tumor:blood ratio was 3:1 by 72 h, and higher ratios were observed at later time points. No abnormal accumulation of (111)In-labeled conjugate was found in normal tissues. In contrast, there was little accumulation of (125)I-labeled KM871 in the same tumors. The specificity of antibody localization was confirmed by the low tumor uptake values for radiolabeled control antibody. Gamma camera imaging demonstrated excellent uptake of (111)In-labeled CHX-A"-DTPA-KM871 in the xenografts. Chromatographic analyses of xenograft cytosolic extracts demonstrated tumor internalization and catabolism of radiolabeled KM871 with the formation of small molecular weight metabolites. Laser scanning confocal microscopy demonstrated that the majority of intracellular KM871 is localized to lysosomes. Despite the catabolism of the radioconjugate, a dose-dependent increase in KM871 tumor localization was shown through immunohistochemical examination of xenograft biopsies. This study demonstrates for the first time the in vivo localization of a radiolabeled anti-G(D3) monoclonal antibody to G(D3)-expressing xenografts using gamma camera scanning techniques and tumor cell internalization of KM871 tagged with a green fluorescent dye, Alexa Fluor 488, through confocal microscopy. KM871 has potential for targeting tumors in patients with melanoma.

Animals↗

Targeting properties of an anti-CD16/anti-CD30 bispecific antibody in an in vivo system.

Bispecific antibodies are currently being used in clinical trials in increasing numbers in the areas of breast cancer, prostate cancer, non-Hodgkin's lymphoma and Hodgkin's lymphoma. We have previously performed two clinical trials in patients with Hodgkin's disease with an anti-CD30/anti-CD16 bispecific antibody and demonstrated a 30% response rate in a cohort of patients otherwise resistant to standard therapeutic modalities. However, no surrogate marker could be defined in these trials indicative of optimal antibody dosing/scheduling or predictive for favorable response. In order to evaluate accurately the potential biodistribution properties of bispecific antibody in patients, we have performed a detailed analysis of the binding properties and animal model in vivo characteristics of these constructs. For this purpose, the parental antibodies (anti-CD30 and anti-CD16) and the bispecific antibody (anti-CD30/anti-CD16) were radiolabeled with either 125I or 111In. Antibody integrity and binding properties after labeling were confirmed by Scatchard plot and Lindmo analysis. 111In-labeled antibodies revealed superior targeting properties in a standard SCID mouse tumor model. Both the bivalent parental anti-CD30 monoclonal antibody and the monovalent anti-CD30/anti-CD16 bispecific antibody showed excellent uptake in CD30+ tumors which did not differ significantly between the two (maximum uptake 16.5%+/-4.2% vs. 18.4%+/-3.8% injected dose/gram tissue). The equivalent targeting properties of the bispecific antibody compared with the parental anti-CD30 antibody encourages the further clinical development of this bispecific antibody, and might help to explain the clinical responses seen with this antibody so far in patients suffering from Hodgkin's disease.

Animals↗

Construction, expression and characterisation of a single-chain diabody derived from a humanised anti-Lewis Y cancer targeting antibody using a heat-inducible bacterial secretion vector.

A single-chain antibody fragment (scFv) of the humanised monoclonal antibody, hu3S193, that reacts specifically with Le(y) antigen expressed in numerous human epithelial carcinomas was constructed. A five-residue linker joined the C-terminus of the V(H) and the N-terminus of the V(L), which prevented V-domain association into a monomeric scFv and instead directed non-covalent association of two scFvs into a dimer or diabody. The diabody was secreted into the E. coli periplasm using a heat-inducible vector, pPOW3, and recovered as a soluble, correctly processed protein, following osmotic shock or solubilised with 4 M urea from the insoluble fraction. The diabody from both fractions was isolated by a rapid batch affinity chromatography procedure, using the FLAG affinity tag to minimise degradation and aggregation. The purified diabody has an Mr of approximately 54 kDa, was stable and demonstrated similar binding activity as the parent monoclonal antibody, as measured by FACS and BIAcore analyses. The radiolabelled diabody showed a rapid tumour uptake, with fast blood clearance, proving it to be an excellent potential candidate as a tumour-imaging agent.

Amino Acid Sequence↗

Management and long-term follow-up of hepatic cysts.

PURPOSE: To provide an algorithm for the management of hepatic cysts through an analysis of our series over 16 years. METHOD: We reviewed the surgical management and outcome of patients with hepatic cysts between 1984 and 2000 at a single institution. Data were collected by chart review, telephone interview, and follow-up hepatic ultrasonography. RESULTS: Forty-four patients (36 females, 8 males) underwent a total of 46 operations for hepatic cysts (mean size 12.0 +/- 5.2 cm) with a mean follow-up of 5.1 +/- 4.0 years. We treated 28 simple cysts, 4 polycystic liver disease (PCLD), 7 cystadenomas, 2 hydatid cysts, 1 cystadenocarcinoma, 1 endometrioma, and 1 hepatic foregut cyst. Operations included simple drainage, wide unroofing (open and laparoscopic), and hepatic resection. Four patients experienced a symptomatic recurrence after definitive treatment; 3 of these patients had PCLD. Four of the 7 patients with cystadenomas had undergone previous operations that required subsequent definitive resection without a recurrence. CONCLUSIONS: The preoperative distinction between simple cysts and cystadenomas/cystadenocarcinomas can be difficult, yet the management is different. Unroofing is a safe and effective operation for patients with simple cysts. Patients with PCLD frequently have recurrences. Cystadenomas should be completely resected owing to the likelihood of recurrence after partial excision and the risk of eventual cystadenocarcinoma. We present a treatment algorithm for the preoperative evaluation and management of hepatic cysts based on the largest number of patients with the longest follow-up reported to date.

Adolescent↗

Hepatic bipolar radio-frequency ablation between separated multiprong electrodes.

Radio-frequency (RF) ablation has become an important means of treatment of nonresectable primary and metastatic liver tumors. Major limitations are small lesion size, which make multiple applications necessary, and incomplete killing of tumor cells, resulting in high recurrence rates. We examined a new bipolar RF ablation method incorporating two probes with hooked electrodes (RITA model 30). We performed monopolar and bipolar in vivo experiments on three pigs. The electrodes were 2.5 cm apart and rotated 45 degrees relative to each other. We used temperature-controlled mode at 95 degrees C. Lesion volumes were 3.9+/-1.8 cm3 (n=7) for the monopolar case and 12.2 +/- 3 cm3 (n=10) for the bipolar case. We generated finite-element models (FEMs) of monopolar and bipolar configurations. We analyzed the distribution of temperature and electric field of the finite element model. The lesion volumes for the FEM are 7.95 cm3 for the monopolar and 18.79 cm3 for the bipolar case. The new bipolar method creates larger lesions and is less dependent on local inhomogenities in liver tissue-such as blood perfusion-compared with monopolar RF ablation. A limitation of the new method is that the power dissipation of the two probes cannot be controlled independently in response to different conditions in the vicinity of each probe. This may result in nonuniform lesions and decreased lesion size.

Animals↗

Effect of vascular occlusion on radiofrequency ablation of the liver: results in a porcine model.

OBJECTIVE: This study determined the effect of vascular occlusion on radiofrequency lesion shape, volume, and temperature in a porcine liver model. SUBJECTS AND METHODS: Radiofrequency lesions (n = 33) were created in the livers of six domestic pigs in vivo using a multiprong radiofrequency electrode. Lesions were randomly assigned to one of four vascular occlusion groups: portal vein, hepatic artery, Pringle maneuver (both hepatic artery and portal vein), or no occlusion. Radiofrequency parameters were time, 7 min; power, 50 W; and target temperature, 100 degrees C. Temperatures were measured 5, 10, and 15 mm from the electrode. After the animals were sacrificed, the lesions were excised. Lesion volume, diameter, and shape; maximum temperature; and time exposed to lethal temperatures (42-60 degrees C) were determined. RESULTS: Lesion volume was greatest with the Pringle maneuver lesions (12.6 +/- 4.8 cm(3)), followed by occlusion of the portal vein (8.6 +/- 3.8 cm(3)), occlusion of the hepatic artery (7.6 +/- 2.9 cm(3)), and no occlusion (4.3 +/- 1.0 cm(3)) (p < 0.05). Maximum lesion diameter was similar with the Pringle maneuver (3.3 +/- 0.3 cm), the portal vein (3.3 +/- 0.2 cm), and the hepatic artery (3.2 +/- 0.2 cm) groups compared with no occlusion (2.6 +/- 1.0 cm) (p < 0.05). Minimum lesion diameter ranged from 2.9 cm for Pringle maneuver lesions to 1.0 cm for lesions with no occlusion (p < 0.05). Vascular occlusion increased the time tissue was exposed to lethal temperatures (> 42-60 degrees C) and created more spherical lesions than no occlusion. CONCLUSION: Vascular occlusion combined with radiofrequency ablation increases the volume of necrosis, creates a more spherical lesion, and increases the time tissue is exposed to lethal temperatures when compared with radiofrequency alone. Most of this vascular occlusion effect could be accomplished with hepatic artery occlusion alone.

Animals↗

Biodistribution properties of (111)indium-labeled C-functionalized trans-cyclohexyl diethylenetriaminepentaacetic acid humanized 3S193 diabody and F(ab')(2) constructs in a breast carcinoma xenograft model.

The humanized complementarity determining region-grafted anti-Lewis Y (Le(y)) monoclonal antibody [humanized 3S193 (hu3S193)] was developed for targeting Le(y)-expressing epithelial tumors such as breast, colon, lung, prostate, and ovarian carcinoma. We are exploring the potential use of smaller molecular size, bivalent analogues of hu3S193, because the faster blood clearance of M(r) approximately 54,000 diabody and M(r) approximately 110,000 F(ab')(2) molecules may be advantageous in achieving optimal and rapid tumor uptake for diagnostic and potential therapeutic applications. The single-chain variable fragment-5 residue linker construct (diabody) was expressed using the bacterial secretion vector pPOW3, and soluble product was purified without refolding processes. The F(ab')(2) fragment was obtained by pepsin digest of parental hu3S193. To facilitate evaluations, the radiometal (111)In was used to label C-functionalized trans-cyclohexyl diethylenetriaminepentaacetic acid chelated diabody and F(ab')(2). The immunoreactivity of the radiolabeled constructs was 41.3 and 58.6%, and the K(a) was 1.68 x 10(6) M(-1) and 5.33 x 10(6) M(-1) for the diabody and F(ab')(2), respectively. Radioconjugates were injected into mice bearing Le(y)-positive MCF-7 tumors, and biodistribution properties were determined at various time points after injection. The uptake of radiolabeled diabody in xenografts was maximal at 1 h after injection (4.7 +/- 0.6% injected dose/g), whereas the F(ab')(2) peaked at 8 h after injection (14.2 +/- 2.4% injected dose/g). The tumor:blood ratio at 4 h for the diabody and F(ab')(2) was 5:1 and 2:1, which increased to 20:1 and 5:1, respectively, at 8 h and increased further to 40:1 and 130:1, respectively, at 48 h. These results demonstrate that the diabody construct may have applications as a diagnostic imaging reagent, whereas F(ab')(2) displayed effective tumor targeting and may have potential as a therapeutic molecule in patients with Le(y)-expressing tumors.

Animals↗

Immuno-PET of human colon xenograft- bearing BALB/c nude mice using 124I-CDR-grafted humanized A33 monoclonal antibody.

UNLABELLED: Radiolabeling monoclonal antibodies (mAbs) allows the evaluation of biodistribution of constructs in vivo through gamma camera imaging and also permits quantitation of mAb uptake in tumors through biopsy-based counting techniques. The quantitation of radiolabeled mAb uptake in cancer patients is complicated by the attenuation of gamma emissions of routinely used isotopes (e.g., 131I and 111In) and the spatial resolution and sensitivity of gamma cameras. METHODS: We used the positron-emitting isotope 124I (half-life [T1/2] = 4.2 d) to label the recombinant humanized anti-colorectal cancer A33 antibody (huA33) and evaluated its biodistribution properties and PET imaging characteristics in BALB/c nude mice bearing SW1222 colorectal xenografts and control colon tumors. RESULTS: The immunoreactivity of radioconjugate was 78% as determined using the cell-binding Lindmo assay. The apparent association constant was found to be 2.2 x 10(9) M(-1), and the number of antibody binding sites per cell was 371,000. The radioconjugate was found to be stable in serum obtained from mice at various times after injection. Assuming a two-compartment model with a four-parameter fit of mean blood levels, the T1/2alpha was 1.5 h and the T1/2beta was 38.2 h. Excellent tumor uptake was obtained, with maximal uptake reaching 50.0 +/- 7.0 percentage injected dose per gram of tumor by 4 d after injection. Specificity of localization was shown by lack of uptake in control tumor. PET imaging detected antigen-positive tumor by 4 h after injection, and high-resolution images were obtained by 24 h after injection. CONCLUSION: In clinical trials using PET, huA33 labeled with 124I has potential for imaging and staging colon tumors and quantifying antibody uptake in colon tumors in vivo.

Animals↗

PET imaging of (86)Y-labeled anti-Lewis Y monoclonal antibodies in a nude mouse model: comparison between (86)Y and (111)In radiolabels.

UNLABELLED: Absorbed doses in (90)Y radioimmunotherapy are usually estimated by extrapolating from (111)In imaging data. PET using (86)Y (beta(+) 33%; half-life, 14.7 h) as a surrogate radiolabel could be a more accurate alternative. The aim of this study was to evaluate an (86)Y-labeled monoclonal antibody (mAb) as a PET imaging agent and to compare the biodistribution of (86)Y- and (111)In-labeled mAb. METHODS: The humanized anti-Lewis Y mAb hu3S193 was labeled with (111)In or (86)Y through CHX-A"-diethylenetriaminepentaacetic acid chelation. In vitro cell binding and cellular retention of radiolabeled hu3S193 were evaluated using HCT-15 colon carcinoma cells, a cell line expressing Lewis Y. Nude mice bearing HCT-15 xenografts were injected with (86)Y-hu3S193 or (111)In-hu3S193. The biodistribution was studied by measurements of dissected tissues as well as by PET and planar imaging. RESULTS: The overall radiochemical yield in hu3S193 labeling and purification was 42% +/- 2% (n = 2) and 76% +/- 3% (n = 6) for (86)Y and (111)In, respectively. Both radioimmunoconjugates specifically bound to HCT-15 cells. When cellular retention of hu3S193 was studied using (111)In-hu3S193, 80% of initially cell-bound (111)In activity was released into the medium as high-molecular-weight compounds within 8 h. When coadministered, in vivo tumor uptake of (86)Y-hu3S193 and (111)In-hu3S193 reached maximum values of 30 +/- 6 and 29 +/- 6 percentage injected dose per gram and tumor sites were easily identifiable by PET and planar imaging, respectively. CONCLUSION: At 2 d after injection of (111)In-hu3S193 and (86)Y-hu3S193 radioimmunoconjugates, the uptake of (111)In and (86)Y activity was generally similar in most tissues. After 4 d, however, the concentration of (86)Y activity was significantly higher in several tissues, including tumor and bone tissue. Accordingly, the quantitative information offered by PET, combined with the presumably identical biodistribution of (86)Y and (90)Y radiolabels, should enable more accurate absorbed dose estimates in (90)Y radioimmunotherapy.

Animals↗

Tissue examination to monitor antiangiogenic therapy: a phase I clinical trial with endostatin.

PURPOSE: The purpose of this study was to determine the effect of the angiogenesis inhibitor endostatin on blood vessels in tumors and wound sites. EXPERIMENTAL DESIGN: In a Phase I dose escalation study, cancer patients were treated with daily infusions of human recombinant endostatin. Tumor biopsies were obtained prior to and 8 weeks after initiation of treatment. Blood vessel formation in nonneoplastic tissue was evaluated by creating a skin wound site on the arm with a punch biopsy device. The wound site was sampled with a second biopsy after a 7-day interval. This sequential biopsy procedure was performed prior to and 3 weeks after initiation of endostatin treatment. Vascular density, endothelial cell kinetics, and blood vessel maturity were determined in tumor and skin wound samples. The ultrastructure of tumor blood vessels was examined by electron microscopy. RESULTS: As expected, the tumors were of variable vascular density. Skin wounding induced a vascular granulation tissue containing a high percentage of proliferating endothelial cells. The proportion of immature blood vessels was high in tumors and in wound sites and low in normal skin. No statistically significant difference was detected between pretreatment and treatment samples of tumors and of skin wounds for any of the parameters tested. CONCLUSIONS: Endostatin treatment was not associated with any recognizable vascular changes in tumor samples and did not perturb wound healing at the doses and the treatment schedule used.

Angiogenesis Inhibitors↗

In vivo biodistribution of a humanized anti-Lewis Y monoclonal antibody (hu3S193) in MCF-7 xenografted BALB/c nude mice.

The biodistribution characteristics of a humanized anti-Lewis(y) antibody (hu3S193) radiolabeled to three radioisotopes, 125I, 111In, and 90Y, were examined in a BALB/c nude mouse xenograft model of breast cancer. The immunoreactivity of both 125I- and 111In-bound hu3S193 exceeded 50% and was 20% for 90Y. In vivo, labeled antibody was shown by gamma camera imaging and immunohistochemical and autoradiographic techniques to localize to Lewis(y)-expressing breast xenografts with minimal normal tissue uptake. Maximal radioisotope uptake peaked at 48 h for all three isotopes; however, the percentage of injected dose/gram and tumor retention were greater for 111In- and 90Y-bound antibody than for 125I-bound antibody. Although immunoreactivity of 111In- and 125I-labeled hu3S193 in serum was stable over a 5-day period, the amount of unlabeled 111In in serum was lower than 125I, which together with higher tumor uptake indicates better retention of 111In-labeled hu3S193 and catabolites within the tumor cells. Superior tumor uptake and retention of 111In-labeled hu3S193 and similar blood clearance compared with 125I-labeled hu3S193, suggest that radiometals are the preferred radioisotope for this antibody-antigen system. Humanized 3S193 is a promising new construct for the targeting and potential therapy of Lewis(y)-expressing tumors.

Adenocarcinoma↗

Construction, production, and characterization of humanized anti-Lewis Y monoclonal antibody 3S193 for targeted immunotherapy of solid tumors.

The Lewis Y (Ley) antigen is a blood group-related antigen that is expressed in a high proportion of epithelial cancers (including breast, colon, ovary, and lung cancer) and is an attractive target for monoclonal antibody-directed therapy. The murine monoclonal 3S193 (IgG3) was generated in BALB/c mice by immunization with Ley-expressing cells of the MCF-7 breast carcinoma cell-line. The murine 3S193 showed high specificity for Ley in ELISA tests with synthetic Ley and Ley-containing glycoproteins and glycolipids and also reacted strongly in rosetting assays and cytotoxic tests with Ley-expressing cells. We generated a humanized form of the murine 3S193 antibody by linking cDNA sequences encoding the variable region of murine 3S913 with frameworks of the human KOL heavy chain and REI K chain. The genes for the humanized 3S193 monoclonal antibody IgG1 were transfected into mouse myeloma NS0 cells and cloned for the establishment of high antibody-producing colonies. Humanized 3S193 antibody was subsequently produced through in vitro culture and under good manufacturing practice conditions using hollow-fiber bioreactors. The purified humanized 3S193 (hu3S193) was subsequently characterized and validated for use in preliminary immunotherapy investigations. hu3S193 reacted specifically with Ley antigen, with similar avidity to the murine form. hu3S193 demonstrated potent immune effector function, with higher antibody-dependent cell-mediated cytotoxicity than its murine counterpart and potent complement-dependent cytotoxicity (ED50, 1.0 microg/ml). The in vivo immunotherapeutic potential of hu3S193 was assessed in a human breast xenograft model using MCF-7, Ley-positive cells. Six i.v. doses of up to 1 mg of hu3S193 were administered to animals bearing established tumors (120-130 mm3) with no significant effect on tumor growth. In contrast, in an MCF-7 xenograft preventive model, a 1-mg hu3S193 dosage schedule was able to significantly slow tumor growth compared with placebo and isotype-matched control IgG1 antibody. hu3S193 has promise for immunotherapy of Ley-positive tumors and is currently entering Phase I clinical trials.

Amino Acid Sequence↗