PubMed Health⌕ Search

Biomedical subjects

F Tagliaro

Publications and source records attributed to F Tagliaro.

At least 37 records · Page 2Linked to original sources

Advances in capillary electrophoresis.

This review summarizes the advancement in operational modes and selected applications of the title technique over the past five years. Regarding operational modes particular emphasis is put upon increasing selectivity and resolution, hyphenation of capillary electrophoresis with techniques based on other than electromigration principles, the so-called chip technology and new ways of detection. In applications selected examples of chiral separation and separation of biopolymers (proteins, nucleic acids) are emphasized. It is demonstrated that capillary electrophoresis represents a complementary technique to high-performance column chromatography and in a number of cases it offers better separations than standard chromatographic procedures.

Electrophoresis, Capillary↗

Hair analysis for abused drugs by capillary zone electrophoresis with field-amplified sample stacking.

The present paper describes the methodological optimisation and validation of a capillary zone electrophoresis method for the determination of morphine, cocaine and 3,4-methylenedioxymethamphetamine (MDMA) in hair, with injection based on field-amplified sample stacking. Diode array UV absorption detection was used to improve analytical selectivity and identification power. Analytical conditions: running buffer 100 mM potassium phosphate adjusted to pH 2.5 with phosphoric acid, applied potential 10 kV, temperature 20 degrees C, injection by electromigration at 10 kV for 10 s, detection by UV absorption at the fixed wavelength of 200 nm or by recording the full spectrum between 190 and 400 nm. Injection conditions: the dried hair extracts were reconstituted with a low-conductivity solvent (0.1 mM formic acid), the injection end of the capillary was dipped in water for 5 s without applying pressure (external rinse step), then a plug of 0.1 mM phosphoric acid was loaded by applying 0.5 psi for 10 s and, finally, the sample was injected electrokinetically at 10 kV for 10 s. Under the described conditions, the limit of detection was 2 ng/ml for MDMA, 8 ng/ml for cocaine and 6 ng/ml for morphine (with a signal-to-noise ratio of 5). The lowest concentration suitable for recording interpretable spectra was about 10-20-times the limit of detection of each analyte. The intraday and day-to-day reproducibility of migration times (n = 6), with internal standardisation, was characterised by R.S.D. values < or = 0.6%; peak area R.S.D.s were better than 10% in intraday and than 15% in day-to-day experiments. Analytical linearity was good with R2 better than 0.9990 for all the analytes.

Cocaine↗

Simultaneous chiral separation of 3,4-methylenedioxymethamphet- amine, 3-4-methylenedioxyamphetamine, 3,4-methylenedioxyethylam- phetamine, ephedrine, amphetamine and methamphetamine by capillary electrophoresis in uncoated and coated capillaries with native beta-cyclodextrin as the chiral selector: preliminary application to the analysis of urine and hair.

The importance of the chiral analysis of amphetamine-related substances in both clandestine preparations and biological samples is widely recognized. For this purpose, capillary electrophoresis was successfully applied by several authors, but only few reports concerned ring-substituted amphetamines, which represent the main components of "ecstasy", a widely abused "recreational" substance. In the present work, the simultaneous chiral analysis of ephedrine, amphetamine, methamphetamine, 3,4-methylenedioxymethamphetamine (MDMA), 3-4-methylenedioxyamphetamine (MDA) and 3,4-methalenedioxyethylamphetamine (MDE) is reported, by using capillary electrophoresis with native beta-cyclodextrin (15 mM) as the chiral selector. After preliminary tests at different pH values (phosphate buffer 100 mM, pH 2.5-9.0) and with bare or coated fused-silica capillaries, the optimized conditions were: pH 2.5 phosphate, uncoated capillary (45 cm x 50 microm inner diameter), potential 10 kV. Detection was either by fixed wavelength (200 nm) or multiwavelength (190-400 nm) UV absorbance. Under these conditions, good resolution was obtained for all the analytes, with excellent chiral selectivity and efficiency. The sensitivity for the individual enantiomers was better than 0.2 microg/mL, analytical precision was characterized by relative standard deviation values < 0.8% (< or = 0.15% with internal standardization) for migration times intra-day and < 2.0% (< or = 0.54% with internal standardization) day-to-day; linearity, in the range 0.156-40 microg/mL, and accuracy were also satisfactory. After a simple liquid-liquid extraction, urine samples could be analyzed with a sensitivity well below the recommended NIDA cut-off of 500 ng/mL. For hair samples, it was necessary to increase the sensitivity by applying a field-amplified sample stacking procedure, which allowed the chiral determination of MDA, MDMA and MDE at concentrations occurring in real samples from ecstasy users, with the possibility of recording UV spectra of the peaks.

Amphetamines↗

Optimized determination of carbohydrate-deficient transferrin isoforms in serum by capillary zone electrophoresis.

Carbohydrate deficient transferrin (CDT) is one of the most reliable markers of chronic alcohol abuse. It consists of a group of minor isoforms of human transferrin (the main iron transport serum protein) deficient in sialic acid groups (asialo, monosialo and disialo) with a pI > 5.7, while the main isotransferrin (tetrasialo) has a pI of 5.4. The aim of the present work was to develop a capillary electrophoretic method to determine CDT in serum, suitable for routine use as a confirmatory technique of the current screening methods based on immunoassays. Serum samples (0.5 mL) were saturated with iron by incubation with 10 mM FeCl3 (9 microL) and 500 mM NaHCO3 (12 microL) for 30 min, then diluted 1/10 in water and injected by positive pressure (0.5 psi for 10 s). Separation was performed with a capillary zone electrophoretic method using bare fused-silica capillaries (20 microm ID, 37 cm in length) and a buffer composed of 100 mM sodium tetraborate adjusted with boric acid to pH 8.3. Applied voltage was 10 kV and temperature 25 degrees C. Detection was by UV absorption at 200 nm wavelength. Under the described conditions, asialo-, monosialo-, disialo-, trisialo- and tetrasialo-transferrin were separated in human serum. The limit of detection (signal-to-noise ratio of 2) was about 0.3% for disialo-transferrin, and 0.4% of trisialo-transferrin, expressed as percentages of the terasialo-transferrin peak area. Relative standard deviations (RSD) of absolute migration times were < 1%, while RSD of relative migration times (on the basis of tetrasialo-transferrin) were < 0.1%. Intra-day and day-to-day peak quantitation precision studies showed RDS ranging from 4 to 9% and from 13 to 24% for disialo- and trisialo-transferrin, respectively. The results from 30 control subjects, including social drinkers, and 13 alcoholics showed disialo- and trisialo-transferrin significantly increased in patients by a factor of about 4.5 (P < 0.0001).

Adult↗

Optimization of a simple method for the chiral separation of phenethylamines of forensic interest based on cyclodextrin complexation capillary electrophoresis and its preliminary application to the analysis of human urine and hair.

Because of the forensic importance of the chiral analysis of amphetamine and other phenethylamines for investigating their synthetic pathways and the metabolic patterns of these compounds, a capillary electrophoresis method has been developed based on the chiral selectivity of beta-cyclodextrin. The influence of different experimental conditions, such as cyclodextrin nature and concentration, voltage, temperature and buffer concentration and pH, on analytical performance has been studied. The optimized analytical conditions are: capillary: bare fused silica, 50 microns I.D., 40 cm effective length; buffer: 150 mM phosphate pH = 2.5, 15 mM beta-cyclodextrin; voltage: 10 kV; temperature: 17.5 degrees C; detection: UV absorption at 200 nm wavelength. Under these conditions, amphetamine, methamphetamine and ephedrine have been easily separated, with baseline resolution of the respective enantiomers. Sensitivity was better than 300 ng per ml. The average precision of migration times of the three analytes was good with RSD = 0.45% and 0.58% in intra-day and day-to-day tests, respectively. Reproducibility of peak heights was also good, with RSD = 2.51% and 3.14% in intra-day and day-to-day tests, respectively. The preliminary analysis of amphetamine in human urine and hair samples, subjected to a simple work-up procedure based on liquid-liquid extraction, showed clean blank electropherograms, excellent chiral resolution and sensitivity, suitable for the analysis of real samples from amphetamine users.

Amphetamine↗

Determination of apomorphine in human plasma by alumina extraction and high-performance liquid chromatography with electrochemical detection.

Apomorphine is a powerful agonist of dopaminergic receptors which several years ago was introduced into the therapy of Parkinson's Disease. The pharmacological activity of apomorphine already appears significant at low doses. Unfortunately, the difficulty in determining the drug in plasma at low concentrations hampers the completion of accurate pharmacokinetic studies in humans. Considering the analogy of apomorphine with the molecular structure of catecholamines, the extraction of the drug from plasma was optimized by using adsorption on alumina, a technique widely used for noradrenaline and adrenaline analysis in clinical chemistry laboratories. This method proved particularly efficient and selective in apomorphine extraction from plasma prior to high-performance liquid chromatographic analysis. After pretreatment of 200 microliters of plasma sample with 40 mg of alumina and 10 microliters of tris buffer (pH 8.6), the drug was eluted with 200 microliters of an acidic-organic solution. One volume of the supernatant was mixed with two volumes of phosphate buffer (pH 3.6), and 100 microliters of the obtained mixture were injected into the HPLC system. The chromatograph was equipped with a C18 reversed-phase column and with an electrochemical coulometric detector fitted with a high-sensitivity cell (first electrode 0.00 volts, second electrode +0.35 volts). Sensitivity (20 pg of injected drug), precision (CV within assay and between assays of 3.7% and 5.6%, respectively) and accuracy were comparable to more complex analytical procedures. The miniaturisation of the entire sample pretreatment proved very advantageous for pharmacokinetics studies and, in principle, for therapeutic drug monitoring and toxicological investigations.

Adsorption↗

Hair analysis, a novel tool in forensic and biomedical sciences: new chromatographic and electrophoretic/electrokinetic analytical strategies.

Hair analysis for abused drugs is recognized as a powerful tool to investigate exposure of subjects to these substances. In fact, drugs permeate the hair matrix at the root level and above. Evidence of their presence remains incorporated into the hair stalk for the entire life of this structure. Most abusive drugs (e.g. opiates, cocaine, amphetamines, cannabinoids etc.) and several therapeutic drugs (e.g. antibiotics, theophylline, beta 2-agonists, etc.) have been demonstrated to be detectable in the hair of chronic users. Hence, hair analysis has been proposed to investigate drug abuses for epidemiological, clinical, administrative and forensic purposes, such as in questions of drug-related fatalities and revocation of driving licences, alleged drug addiction or drug abstinence in criminal or civil cases and for the follow-up of detoxication treatments. However, analytical and interpretative problems still remain and these limit the acceptance of this methodology, especially when the results from hair analysis represent a single piece of evidence and can not be supported by concurrent data. The present paper presents an updated review (with 102 references) of the modern techniques for hair analysis, including screening methods (e.g. immunoassays) and more sophisticated methodologies adopted for results confirmation and/or for research purposes, with special emphasis on gas chromatography-mass spectrometry, liquid chromatography and capillary electrophoresis.

Chromatography↗

Integrated use of hair analysis to investigate the physical fitness to obtain the driving licence: a casework study.

According to the laws presently in force in Italy and the guidelines of the Driving Licence Enforcement Commission of Verona, applicants for the driving licence with a history of drug abuse undergo a medical examination, during which complete anamnestic and clinical data are recorded. On this occasion, a hair sample (50-200 mg) is collected and a urinalysis program is started consisting of EMIT controls for opiates, methadone, cocaine, barbiturates, amphetamines, cannabinoids, benzodiazepines and alcohol carried out on eight seriate samples, collected at random over about 40 days under direct supervision. The positive results from urine immunoassays are confirmed by standardized GC/MS methods. The hair samples are screened for morphine and cocaine, the most abused illicit substances in our region, using commercial RIAs adopting cut-off levels of 0.1 ng/mg. All positive samples and about 10% of negative are confirmed by HPLC. In case of confirmed positive results, the applicant is informed: if the subject denies use of opiates or cocaine in the recent months, he or she has the chance of submitting for analysis a new hair sample, which is analyzed in parallel with the hair remaining from the previous assay. In case of persisting denial, claiming analytical interferences by other drugs or endogenous substances, further confirmation of results can be carried out by CE and/or by qualitative MS/MS. In addition, hair sampling from multiple sites (scalp, axillary, pubic hair) with different susceptibility to contamination from the external sources can be carried out to rule out the possibility of passive contamination. At present, we investigate more than 700 subjects per year. The results of this integrated diagnostic strategy are presented and discussed.

Automobile Driver Examination↗

Hair analysis for drug abuse. XV. Disposition of 3, 4-methylenedioxymethamphetamine (MDMA) and its related compounds into rat hair and application to hair analysis for MDMA abuse.

In order to clarify the mechanism of drug incorporation into hair, disposition of 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyethylamphetamine (MDEA), 3-methoxy-4,5-methylenedioxyamphetamine (MMDA) and metabolites of MDMA, 4-hydroxy-3-methoxyamphetamine (HMAP) and 4-hydroxy-3-methoxymethamphetamine (HMMA), into hair was investigated with an animal model. After the intraperitoneal administration of those six drugs to pigmented hairy rats (5 mg/kg/day, 10 days, n = 3), the parent compounds and their metabolites in the rat plasma (5, 15, 30, 60, 120, 360 min after administration) and in the newly grown rat hair for 4 weeks were determined by GC/MS-SIM. When the ratio of hair concentration to area under the concentration versus time curves (AUCs) in plasma was represented as an index of incorporation rate (ICR) of drugs into hair, the order of ICRs was HMAP < MDA < HMMA < MDMA < MDEA < MMDA. In the comparison between MDA, MDMA and MDEA, their ICRs increased according to the length of carbon branches from proton to ethyl at the N position. From the point of view that the ICRs of MMDA was 2.3 times as much as that of MDA, the methoxy group on the benzene ring seemed to serve as a positive factor for the ICR. However, the ICRs of 4-hydroxy-3-methoxy compounds, HMAP and HMMA, were lower in comparison with those of MDA and MDMA, respectively. On the other hand, the ICRs of MDA, MDMA and MDEA were 5.5-6.1 times larger than those of amphetamine, methamphetamine and ethylamphetamine, suggesting that the methylenedioxy group on the benzene ring raises their ICRs very positively. Moreover, in order to apply the results from the animal experiments to human cases, the scalp hair samples of seven MDMA abusers were analyzed. MDMA and its metabolites, MDA; were simultaneously detected in all the samples by GC/MS. In the two samples, MDEA was found in addition to MDMA and MDA. It was shown that a hair sample is a good specimen for the confirmation of retrospective use of methylenedioxyamphetamines.

3,4-Methylenedioxyamphetamine↗

Pharmacokinetics of a new nitroderivative of acetylsalicylic acid after a single dose in rats.

The pharmacokinetics of a new ASA-nitroderivative compound, NCX 4016 (ASA-NO2), was evaluated using an HPLC method. After single equimolar doses of ASA (35 mg kg(-1)) or ASA-NO2 (65 mg kg(-1)), no detectable levels of these compounds have been observed in rat plasma samples. SA peak levels were obtained at 3 h and 6 h after ASA and ASA-NO2 administration respectively. The elimination rate constants of SA were similar after ASA and ASA-NO2, suggesting a similar elimination phase of this metabolite in rats. From these data it is evident that ASA-NO2 is slowly metabolized in ASA, which is rapidly converted to SA.

Animals↗

Assessment of an automated immunoassay based on kinetic interaction of microparticles in solution for determination of opiates and cocaine metabolite in urine.

A recently introduced automated immunoassay which is based on kinetic interaction of microparticles in solution (Roche ONLINE), was evaluated for the detection of cocaine metabolite benzoylecgonine (BE) and opiates in human urine. Cross-reactivity for the opiates morphine (100%), codeine (88%), 6-monoacetylmorphine (88%), and morphine 3-glucuronide (72%) was assessed. Analytical recovery evaluated on blank urines spiked with 0, 250, 300, 350, and 500 micrograms/L of morphine and BE (n = 10), varied from 85.2 to 100.2% for opiates and from 81.4 to 93.1% for the cocaine metabolite. The within-day precision ranged from 1.4 to 4.7% for morphine and from 4.2 to 4.8% for BE. The repeatability of the standards over 1 month was 1.0-3.3% for opiates and 1.7-5.1% for BE, and thus allowing measurements to continue over 30 days without re-calibration. This method compared favourably with the SYVA EMIT d.a.u system and gas chromatography/mass spectroscopy (GC/MS) methods.

Autoanalysis↗

High-performance liquid chromatographic determination of levodropropizine in human plasma with fluorometric detection.

The present paper describes a new high-performance liquid chromatographic method with fluorescence detection for the analysis of levodropropizine [S-(-)-3-(4-phenylpiperazin-1-yl)-propane-1,2-diol] (Levotuss), an anti-tussive drug, in human serum and plasma. A reversed-phase separation of levodropropizine was coupled with detection of the native fluorescence of the molecule, using excitation and emission wavelengths of 240 nm and 350 nm respectively. The analytical column was packed with spherical 5 microns poly(styrene-divinylbenzene) particles and the mobile phase was 0.1 M NaH2PO4 pH 3-methanol (70:30, v/v), containing 0.5% (v/v) tetrahydrofuran. For quantitation, p-methoxylevodropropizine was used as the internal standard. Samples of 200 microliters of either serum or plasma were mixed with 200 microliters of 0.1 M Na2HPO4 pH 8.9 and extracted with 5 ml of chloroform-2-propanol (9:1, v/v). The dried residue from the organic extract was redissolved with distilled water and directly injected into the chromatograph. The limit of detection for levodropropizine, in biological matrix, was about 1-2 ng/ml, at a signal-to-noise ratio of 3. The linearity was satisfactory over a range of concentrations from 3 to 1000 ng/ml (r2 = 0.99910); within-day precision tested in the range 5-100 ng/ml as well as day-to-day reproducibility proved acceptable, with relative standard deviations better than 1% in most cases. Interferences from as many as 91 therapeutic or illicit drugs were excluded.

Antitussive Agents↗

Complementary use of capillary zone electrophoresis and micellar electrokinetic capillary chromatography for mutual confirmation of results in forensic drug analysis.

The purpose of this work was to compare different CE separation modes namely capillary zone electrophoresis (CZE) and micellar electrokinetic capillary chromatography (MECC) for the analysis of drugs of forensic interest in order to assess the mutual degree of independence and consequently the possibility of complementary use for mutual confirmation of results. A panel of drugs including caffeine, morphine, barbital, pentobarbital, codeine, nalorphine, lidocaine, procaine, heroin, flunitrazepam, acetylcodeine, papaverine, amphetamine, narcotine, cocaine, diazepam, tetracaine, narceine, 6-monoacetylmorphine acetylcodeine and thebaine, were separated according to a MECC and two CZE methods. The MECC separation was carried out in a bare silica capillary (50 micron I.D.) with a buffer composed of 25 mM borate (pH 9.24)--20% methanol--100 mM sodium dodecyl sulphate; the applied voltage was 20 kV. The first CZE method (CZE1) was carried out in 50 mM phosphate buffer (pH 2.35) at 20 kV with a bare silica capillary (50 micron I.D.), and the second (CZE2) with 50 mM borate (pH 9.24) at 12 kV with the same capillary. The three methods were effective in the separation of the test drug mixture, but MECC was the only able to resolve all the components. Relative (to flunitrazepam), migration time RSDs ranged from 0.3 to 2.8% for the three methods were compared with Spearman's test and with principal component analysis, CZE1 and CZE2 were significantly and directly correlated (r = 0.749, p < 0.002), whereas MECC and CZE2 were also significantly, but inversely correlated (r = -0.865, p < 0.001). MECC and CZE1 (limitedly to the basic drugs) appeared non-correlated (r= -0.131, p = 0.630) and therefore the two techniques are suitable for combined use to increase the discriminatory power.

Chromatography↗

Determination of illicit drugs and related substances by high-performance liquid chromatography with an electrochemical coulometric-array detector.

A general method for the simultaneous determination of fifteen common drugs (6-acetylmorphine, 3,4-methylenedioxymetamphetamine, buprenorphin, cocaine, codeine, dihydrocodeine, ethylmorphine, heroin, hydrocodone, lidocaine, methadone, morphine, naloxone, procaine and thebaine) was developed using reversed-phase HPLC and electrochemical detection. The separation of the drugs was achieved by using as the mobile phase 20 mM monobasic sodium phosphate-acetonitrile (90:10) with a gradient to 50% of the organic modifier, on a silica based C18 column (150 x 4.6 mm I.D.) of 3 microns particle size and by the selectivity supplied by an array of eight coulometric electrodes at increasing potential. It was possible to identify and to determine fifteen different drugs in the same chromatographic run in 50 min. The method was tentatively applied to the determination of drugs in extracts of human hair.

Chromatography, High Pressure Liquid↗

Capillary electrophoresis: principles and applications in illicit drug analysis.

Capillary electrophoresis, which appeared in the early 1980s, is now rapidly expanding into many scientific disciplines, including analytical chemistry, biotechnology and biomedical and pharmaceutical sciences. In capillary electrophoresis,electrokinetic separations are carried out in tiny capillaries at high voltages (10-30 kV), thus obtaining high efficiencies (N > 10(5)) and excellent mass sensitivities (down to 10(-18)-10(-20) moles). The main features of capillary electrophoresis are: versatility of application (from inorganic ions to large DNA fragments), use of different separation modes with different selectivity, extremely low demands on sample volume, negligible running costs, possibility of interfacing with different detection systems, ruggedness and simplicity of instrumentation. Capillary electrophoresis applications in forensic sciences have appeared only recently, but are now rapidly growing, particularly in forensic toxicology. The present paper briefly describes the basic principles of capillary electrophoresis, from both the instrumental and analytical points of view. Furthermore, the main applications in the analysis of illicit/controlled drugs in both illicit preparations and biological samples are presented and discussed (43 references). It is concluded that the particular separation mechanism and the high complementarity of this technique to chromatography makes capillary electrophoresis a new powerful tool of investigation in the hands of forensic toxicologists.

Electrophoresis, Capillary↗

Capillary electrophoresis of hair proteins modified by alcohol intake in laboratory rats.

A capillary zone electrophoretic method was used to obtain profiles of solubilized rat hair keratin proteins. The same methodology was used to reveal the presence of additional protein peaks in alcohol-consuming rats. Two types of separation were investigated. Alkali-solubilized keratins from hair of rats treated for 5 weeks with 5% ethanol and 2 weeks with 10% ethanol (instead of drinking water) and from controls were analysed. Whereas under alkaline conditions (pH 9.2, 50 mM borate) an additional fraction of "low-sulphur" keratins with the highest anodic mobility of this keratin category was shown in alcohol-treated animals, acid electrophoresis carried out at pH 3.5 in phosphate buffer (50 mM) revealed the presence of two sharp peaks absent in the controls. These findings were confirmed by two-dimensional separations of carboxymethylated keratin samples. An attempt was made to identify further one of the newly occurring fractions in alcohol-consuming animals. It was revealed that the tryptic hydrolysate of "low-sulphur" proteins obtained from alcohol-consuming animals contained a peptide not found in controls.

Alcohol Drinking↗

Capillary electrophoresis: a new tool in forensic toxicology. Applications and prospects in hair analysis for illicit drugs.

Capillary electrophoresis, the modern approach to instrumental electrophoresis, is probably the most rapidly expanding analytical technique that has appeared in recent years. In the hands of forensic toxicologists, capillary electrophoresis (CE) represents a powerful new analytical tool, which has proved suitable for the investigation of illicit drugs in seized preparations and also in complex biological matrices, among which is hair. CE can be applied according to different separation mechanisms, and among those that are toxicologically relevant are capillary zone electrophoresis and micellar electrokinetic capillary chromatography, which display different selectivities. For the investigation of hair for drugs of abuse, capillary electrophoresis proved effective, providing simultaneous determinations of different drugs without derivatization, with acceptable sensitivity (typically better than 1 ng of drug per mg of hair). The possibility of carrying out determinations of the same analytes, based on different separation mechanisms (capillary zone electrophoresis and micellar electrokinetic chromatography) with the same instrumentation, simply changing the buffer composition, provides an interesting possibility of 'internal' confirmation of the results.

Electrophoresis↗

Effect of antibodies to calcitonin on the pharmacokinetics and the pharmacodynamics of the hormone.

Calcitonin pharmacokinetics and pharmacodynamics were studied in two groups of patients with postmenopausal osteoporosis, who, treated for one year with intranasal Asu1.7-eel calcitonin (eCT), had (Ab+) and had not (Ab-) developed a specific immune response to the drug. The treatment consisted of daily intranasal administrations of eCT (80 IU/die) with 1 g supplemental calcium. Eight women who had developed specific antibodies and 5 who had not, were given 50 IU of CT i.m., in order to assess the pharmacokinetics and pharmacodynamics of the drug. The rise of serum levels of the hormone was significantly greater in Ab+ than in Ab- patients. At the end of the study, no significant differences in mineral bone loss between the two groups were found. In conclusion, the presence of antibodies to eCT does not represent a negative event in the therapy of osteoporosis, but significantly affects the pharmacokinetics of the drug.

Antibodies↗