PubMed Health⌕ Search

Biomedical subjects

F Todi

Publications and source records attributed to F Todi.

5 recordsLinked to original sources

The confirmation and control of metabolic caffeine in standardbred horses after administration of theophylline.

The origin of caffeine detections in equine serum and urine after theophylline administrations was examined. Three different preparations containing theophylline were administered to standardbred mares. Both blood and urine samples were collected. Caffeine was detected and quantified in theophylline administration samples by high performance liquid chromatography (HPLC) and liquid chromatography-tandem mass spectrometry (LC-MS-MS). Further in vitro analysis showed that caffeine metabolites were not detected when caffeine, or caffeine-containing products, were added to urine. Data derived from HPLC-UV and LC-MS-MS analysis of dosages of theophylline and caffeine are used to propose the establishment of a threshold limit to control and discern between metabolic and administered caffeine concentrations. A serum caffeine concentration of 250 ng/mL and a urine caffeine concentration of 1000 ng/mL are suggested. Based on the data supplied, these threshold concentrations could effectively control orally administered caffeine in racehorses, up to the dosage used in this work, up to 72 h before sampling time.

Animals↗

Monitoring furosemide in racehorses participating in an EIPH program.

Analytical procedures were developed to monitor furosemide concentrations in post-race serum and urine samples obtained from horses participating in an exercise-induced pulmonary haemorrhage (EIPH) program. High performance liquid chromatography with ultraviolet light detection proved a reliable, sensitive method for measuring urinary furosemide concentrations up to 12 h after administration of either 150 or 250 mg of the drug to race horses. However, this method was unreliable for determination of serum furosemide concentration. High performance liquid chromatography with fluorescence detection proved a reliable, sensitive method for measuring serum furosemide concentration in horses administered 250 mg of the diuretic, permitting detection of approximately 5-10 ng/ml 6 h after treatment. This method was applied to field conditions where furosemide was administered to horses (between 150 and 250 mg intravenously) 4 h prior to the race. Analytical results assisted in establishing a threshold concentration of 85 ng/ml for serum furosemide. It was found that serum furosemide concentrations are a valid measure of compliance with furosemide administration in the EIPH program.

Animals↗

Plasma elimination and urinary excretion of procaine after administration of different products to standardbred mares.

Plasma and urinary concentrations of procaine were examined in Standardbred mares after subcutaneous administration of various doses (80 mg to 1600 mg) of procaine hydrochloride. Regardless of dose, peak plasma procaine values occurred within 1 h, but remained detectable in a dose-dependent manner, with procaine present at 1 h with the 80 mg dose and 6 h at the 1600 mg dose. Similarly, peak urinary procaine concentrations were attained within 1.5 to 3 h, irrespective of dose, while detection time was dose-dependent, being 23 h for 80-200 mg doses but as long as 30-54 h with the 1600 mg dose. When mares were given a single intramuscular injection of a penicillin G-procaine preparation (Ethacillin, Cillimycin, Penamycin, Derapen A, Azimycin or Diathal), peak plasma procaine concentrations varied and were reached from 10 min to 3 h in all cases, with detection from 3 to 20 h after drug administration. Although the peak urinary levels of procaine occurred between 30 mins and 6 h, detection in urine in most cases was as long as 78-120 h except for Diathal for which detection was limited to 54 h. Daily administration of a penicillin G-procaine preparation (Pen-Di-Strep) for 5 days produced a biphasic peak in plasma procaine at 3 and at 6-9 h with detection from 16 to 23 h after drug treatment. Although peak urinary procaine values were reached at similar times after single or multiple injections, the duration of detection was markedly longer (425 h) after the multiple-dose regimen.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

The influence of furosemide on plasma elimination and urinary excretion of drugs in standardbred horses.

A study of the effects of intravenous administration of either 150 mg or 250 mg of furosemide to standardbred mares pre-treated with other drugs was undertaken to determine whether a unique pattern of drug elimination into urine and from plasma for each compound occurred. Furosemide significantly reduced the plasma concentrations of codeine compared to control 2-6 h after furosemide administration. In contrast, the plasma concentrations of theophylline, phenylbutazone, pentazocine, guaifenesin and flunixin were not markedly altered by furosemide. In the case of acepromazine, clenbuterol and fentanyl, the data generated were insufficient to state with certainty whether or not furosemide affected the plasma concentrations of these three drugs. A significant reduction was noted in the urinary concentrations of guaifenesin, acepromazine, clenbuterol, phenylbutazone, flunixin, fentanyl and pentazocine within 1-4 h of furosemide administration. The urinary concentrations of theophylline remained reduced as long as 8 h after furosemide injection. Furosemide administration to horses pre-treated with codeine resulted in depression of urinary morphine concentrations 2-4 h and 9-12 h after furosemide injection. A lower furosemide dose (150 mg) produced changes in drug urinary excretion and plasma elimination equivalent to the higher dose (250 mg). It is evident that furosemide affects the urinary and plasma concentrations of other co-administered drugs but not in a predictable fashion, which limits the extrapolation of these results to as yet untested drugs.

Acepromazine↗

Determination of procaine in equine plasma and urine by high-performance liquid chromatography.

The variability in plasma and urine equine procaine measurement between three independent laboratories using current methods led to the development of a sensitive, reliable, and reproducible high-performance liquid chromatographic method. Standardbred mares were administered either a penicillin G procaine preparation intramuscularly or procaine hydrochloride subcutaneously, and blood and urine were collected at defined time intervals. By HPLC the detection limits for procaine in plasma and urine were 1 and 10 ng/mL, respectively. In contrast procaine in plasma could not be detected by GC-NPD, while the urinary detection limit was 50 ng/mL. The concentration of fluoride in the collection tubes and repetitive freeze-thawing modified plasma procaine measurement. Urinary pH was a factor in estimation of urine procaine levels with greater recovery and reproducibility of results at pH 5 as compared to pH 7. This HPLC method provides a simple, sensitive, and reliable quantitation of procaine in equine plasma and urine.

Animals↗