PubMed Health⌕ Search

Biomedical subjects

F Traina

Publications and source records attributed to F Traina.

At least 19 recordsLinked to original sources

A case report of fracture of ceramic head in total hip arthroplasty: histological and biochemical features of perimplant tissues.

The authors analyzed the case of a patient with a non-cemented hip prosthesis with a ceramic-ceramic coupling. As a consequence of trauma the head fractured. Although the patient could feel the joint grinding, there was no pain and he continued daily living activities for nearly six months, which led to marked wearing of the ceramic head. SEM analysis with microprobe showed 'planed' surfaces on the ceramic head, suggesting repeated movements between the fractured components. Inside the cone of the head, signs of TiAlV, which is an alloy of the prosthetic stem, could be seen. Periprosthetic tissues were packed with ceramic wear particles of sizes ranging between 0.2 and 10 microns, according to the harvest site. Metal and mixed particles were also found. IL1, IL6, IL8 and IL10 assays in the synovial liquid confirmed the inflammatory state and a modest induction of bone resorption, which was less than that observed in patients with loosened metal-polyethylene couplings. The humoral picture was compatible with the radiological aspect, which did not show marked signs of bone resorption. In revision surgery both ceramic components were replaced by a metal head and polyethylene liner. The clinical outcome after 12 months was very good.

Alloys↗

On the biomechanical stability of cementless straight conical hip stems.

The aim of the present study was to investigation in vitro the effect of deficient bone-implant contact on the primary stability of a straight conical stem. Various possible deficient contact patterns were derived from surgical simulations. The effect of stair climbing loads on the bone-implant micromotion was firstly investigated using a finite element model and then an in vitro test aimed at assessing primary stability. It was found that if the surface features are prevented from biting dense bone in a few small but critical regions, stem primary stability is completely lost. These results suggest that the surface features used in the axisymmetric stem under investigation can be too sensitive to deficient contact conditions, and thus should be augmented with additional antirotational fins. Preliminary tests showed that a stem with the addition of such fins presents good primary stability in all tested conditions.

Arthroplasty, Replacement, Hip↗

The predictive power of surface profile parameters on the amount of wear measured in vitro on metal-on-polyethylene artificial hip joints.

Various studies report a weak correlation between the average surface roughness R(a) of metallic ballheads and the observed wear rate of the polyethylene cups coupled to them. The aim of this study is to verify, with controlled in vitro experiments, whether other parameters such as the total roughness R(t), and the skewness R(sk) are better predictors of the polyethylene wear when the metallic heads present a surface conditioning that varies substantially from specimen to specimen, as is usually the case with retrieved specimens. Twelve CoCrMo (cobalt-chromium-molybdenum) ballheads were intentionally damaged in order to reproduce a wide spectrum of surface conditioning and were then subjected to the standard wear test against polyethylene cups, using a hip joint wear simulator. After 2 x 10(6) cycles the weight lost by the cups was assessed with a gravimetric procedure, and the surface roughness of the metallic ballheads was qualified in terms of R(a), R(t), and R(sk). The various parameters were correlated to the weight loss using a linear regression analysis. The skewness R(sk) showed a coefficient linear regression R2 = 0.80, while the average roughness R(a), used in most previous studies, presented an R2 = 0.56. It was concluded that when specimens with substantially different surface conditioning are compared, as in retrievals analysis, it is also important to report the skewness R(sk) so that qualify the surface roughness of the specimens can be qualified.

Coated Materials, Biocompatible↗

Structural allograft and primary press-fit cup for severe acetabular deficiency. A minimum 6-year follow-up study.

Between October 1992 and December 1996, 23 patients with pelvic bone stock deficiency involving major columns underwent revision surgery with a cementless press-fit cup and a structural bone graft. Twenty cases were followed up for a minimum of 6 (average 7.6, range 6-11) years. Three cups were revised: one for aseptic loosening, one for septic loosening, and one for recurrent dislocation. At latest follow-up, the average Merle d'Aubigne hip score improved from 10.9 to 16.2; four hips were rated excellent, seven very good, three good, two fair, and one poor. All cups were stable; the grafts were integrated and anatomy was restored. The Kaplan-Meier cumulative probability of not having revision for loosening at 11 years, predicted a survival rate of 84.4%. We are confident that these results are satisfactory for a very demanding procedure.

Adult↗

Evaluation of achievable registration accuracy of the femur during minimally invasive total hip replacement.

The aim of the paper was to investigate whether accurate, point-based registration of the intra-operative femur will be achieved within the context of minimally invasive surgery for total hip replacement. Computer tomography images, collected for pre-operative planning purposes, were used to simulate the intra-operative registration procedure using algorithms for various levels of measurement noise, different small areas of the femur available to the surgeon, and a limited number of collected data points (20-60). This helped with the choice of design variables to perform in vitro registration on a plastic bone model to validate the procedure, which included a multistart algorithm developed for intra-operative registration. The algorithm minimised the distance between the measured and image-derived surfaces and was able to cope with the presence of multiple local minima given sufficient computational effort, even with realistically large measurement noise. It was found that, if a small patch of the femur was used, accessible by a needle that could at times penetrate thin layers of soft tissue, errors in the order of 1.0 mm in translation and 0.5 degrees in rotation were achievable.

Algorithms↗

Serious graft-versus-host disease after hematopoietic cell transplantation following nonmyeloablative conditioning.

The efficacy of allogeneic hematopoietic cell transplantation (HCT) after nonmyeloablative conditioning depends on the balance between the desirable antineoplastic effects of donor cells weighed against the undesirable morbidity of graft-versus-host disease (GVHD). Development of serious acute or chronic GVHD was analyzed retrospectively in 171 consecutive patients, who had related or unrelated nonmyeloablative HCT for hematologic malignancies. GVHD was defined as serious when it resulted in (1) death, (2) disability, (3) three or more major infections in 1 year, (4) prolonged hospitalization or (5) suicide or hospitalization for suicidal ideation. According to this definition, 43 of 171 (25%) patients developed serious GVHD with a median follow-up of 30 (range, 12-65) months. The incidence of serious GVHD was similar after related and unrelated HCT. Among the 43 patients with serious GVHD, 20 had grade III-IV acute GVHD, and 30 had extensive chronic GVHD. Among the 171 patients, seven had grade III acute GVHD and 84 had extensive chronic GVHD that did not meet criteria for serious GVHD. Assessment of serious GVHD provides additional useful information to acute GVHD grades and classification of limited and extensive chronic GVHD in describing the overall risk and impact complications caused by donor cells.

Activities of Daily Living↗

Effect of the initial implant fitting on the predicted secondary stability of a cementless stem.

A numerical model able to investigate the influence of biomechanical factors on the long-term secondary stability of implants would be extremely useful for the design of new cementless prosthetic devices. A purely biomechanical model of osseo-integration has been developed, formulated as a rule-based adaptation scheme. Due to its complexity, the problem was divided into three steps: preliminary implementation of the model (proof of concept); implementation of the complete model and investigation of the model solution; and model validation. The paper describes the first of these three steps. The model was implemented as a discrete-states machine, and the few parameters required were derived from the literature. It was then applied to a real clinical case. The study was conducted using the frictional contact finite element model of a human femur implanted with a cementless anatomical stem. A stable solution was achieved after between three and 15 iterations for all initial positions considered. Similar initial conditions yielded similar final configurations. The model predicted all initial configurations, with the exception of a partial osseo-integration, ranging between 62% (distal fit) and 78% (proximal fit) of the viable interface. This is in good agreement with the values reported in the literature that never exceed 75%, even in the best conditions, and report better clinical results for proximal fit. For the varus configuration, which lacks cortical support, the algorithm predicted a completed loosening.

Arthroplasty, Replacement, Hip↗

An easy technique to digest and isolate UHMWPE wear particles from a hip joint simulator.

The size and morphology of polyethylene wear particles isolated from in vitro tests were analysed in this study. There are some major controversies emerging in the literature that will only be resolved by careful particles analysis. Since it is difficult to identify the factors that affect size and morphology of the wear particles, the goal of this study was to compare four different polymer wear debris isolation techniques (base method and acid treatment) under identical conditions in a hip joint simulator to obtain polyethylene wear particles. We investigated achieving particulate isolation by using a different approach to the one reported in the literature that involved an easier and streamline method of particle debris isolation. The new method, compared to the previous one, used a strong base, normal centrifugation, and filtration to digest the serum constituents thus isolating the polyethylene particle debris from lubricant. In all four methods the isolation involved some or all of the following steps: density gradient separation, centrifugation or ultracentrifugation, and washing. However, a requirement for all these techniques was that the lubricant had to be devoid of organic compounds in order to effectively image and count the particle debris. The results from these studies clearly show that this new method of particle isolation is easier and more streamlined than the three methods analysed and reported in literature because it did not involve ultracentrifugation and is quicker.

Arthroplasty, Replacement, Hip↗

Conventional chemotherapy for acute myeloid leukemia: a Brazilian experience.

CONTEXT: Young patients affected by acute myeloid leukemia (AML) achieve complete remission (CR) using conventional chemotherapy in about 55-85%. However, 30% of patients fail to achieve CR and the remission duration is often only about 12 months. More intensive treatment after CR seems to be necessary in order to maintain CR and obtain a definitive cure. In Brazil, few reports have been published on this important subject. OBJECTIVE: The aim of this study was to describe a Brazilian experience in the treatment of "de novo" acute myeloid leukemia (AML) in younger adult patients (age < 60 years). DESIGN: Retrospective analysis. SETTING: University Hospital, Hematology and Hemotherapy Center, State University of Campinas, Brazil. PARTICIPANTS: Newly diagnosed cases of "de novo" AML in the period from January 1994 to December 1998 were evaluated retrospectively, in relation to response to treatment, overall survival (OS) and disease free survival (DFS). Cases with acute promyelocytic leukemia (APL) were also included in this analysis. RESULTS: On the basis of an intention to treat, 78 cases of AML, including 17 cases of APL, were evaluated. The overall median follow-up was 272 days. The complete remission (CR) rate was 63.6% in the AML group (excluding APL) and 78% in the APL group. The 5-year estimated disease-free survival (DFS) was 80% for the APL group and 34% for the AML group (P = 0.02). The 5-year estimated overall survival (OS) was 52% for the APL group and 20.5% for the AML group, respectively (P = NS). Relapse was observed in 12/39 (30.7%) patients with AML and 1/11 (9%) with APL. CONCLUSIONS: These results are similar to those reported in the literature. However, relapse and mortality rates remain high, and a search for more aggressive strategies in order to prevent relapse is recommended.

Acute Disease↗

Total hip arthroplasty in octogenarians: our experience.

The progressive aging of the population, a phenomenon that is common to all Western societies, means an increase in the number of patients aged over 80 years requiring total hip replacement. It is the purpose of this study to report our experience in the use of total hip replacement for the treatment of patients aged over 80 years. The study is retrospective, and it was conducted on a group of 27 patients, for a total of 33 hips. An analysis of the results led us to conclude that there are no differences in indications for total hip replacement in patients aged over 80 years as compared to younger subjects. Nonetheless, it is important to carefully evaluate the general conditions of these patients, prior to surgery, because failure may have dramatic consequences.

Age Factors↗

Computer-assisted tridimensional preoperative planning in hip revision surgery.

It is often difficult to obtain excellent clinical results in complex cases of hip replacement surgery. Over recent years, in order to improve the success rate of this type of surgery, prosthetic implants that are more ductile and more reliable have been developed. At the same time, important progress has been made in improving the accuracy of surgical method. A great deal of effort has been made to improve methods of preoperative planning. The world over, computerized systems that aid the surgeon in his or her clinical practice (CAOS systems) have been developed. The authors present Hip-op, a new CAOS type system, for preoperative planning. In particular, the use of Hip-op in some very complex cases of hip revision surgery is reported. Based on clinical experience, it is believed that Hip-op is a useful system, one that is easy to use, and that it is capable of improving the accuracy of surgery.

Adult↗