PubMed Health⌕ Search

Biomedical subjects

F Vanhaecke

Publications and source records attributed to F Vanhaecke.

12 recordsLinked to original sources

13C and 18O isotopic analysis to determine the origin of L-tartaric acid.

Due to the ever-increasing amount of attention paid to the 'naturalness' of ingredients in food and beverages by both consumers and controlling authorities, the search for suitable methods for the characterisation of origin is of primary importance. Within the European Community the wine production industry is often faced with the problem of origin control of tartaric acid. This has led to the decision that only L-tartaric acid extracted from grapes (therefore natural) should be used. In order to implement these regulations, a screening of different techniques has been carried out to assess the methodology that best identifies the origin of the tartaric acid. It has already been indicated in previous scientific literature that isotope ratio mass spectrometry is an ideal technique for this type of identification. In this paper we present the results obtained for the measurement of the isotope ratios of carbon-13 and oxygen-18 of natural and synthetic samples of L-tartaric acid considering also natural samples of different geographical origin and years of production.

Carbon Isotopes↗

[Cystic fibrosis and uveitis in childhood and multiple sclerosis at adulthood].

We report the case of a patient with cystic fibrosis who suffered severe bilateral uveitis, with hypopyon, retinal vasculitis, and polyarthritis when he was 6 years old. No etiology could be found. Multiple sclerosis began when he was 22 years old. This panuveitis was clinically very different from the uveitis usually associated with multiple sclerosis. Polyarthritis and skin vasculitis have been reported in the course of cystic fibrosis, but no uveitis nor retinal vasculitis have been described. This raises the question of the role of multiple sclerosis and cystic fibrosis in the pathogenesis of this case of uveitis.

Adult↗

Reproductive toxicity of dietary zinc to Daphnia magna.

Regulatory assessments of metals in freshwaters are mostly based on dissolved metal concentrations, assuming that toxicity is caused by waterborne metal only. Little attention has been directed to the toxicity of dietary metals to freshwater invertebrates. In this study the chronic toxicity of dietary zinc to Daphnia magna was investigated. The green alga Pseudokirchneriella subcapitata was exposed for 64 h to a control and three dissolved zinc concentrations, i.e. 23, 28 and 61 microg L(-1), resulting in internal zinc burdens in the algae of 130, 200, 320 and 490 microg g(-1) dry weight, respectively. These algae were used as a food source in chronic, 21-day bioassays with D. magna in a test medium to which no dissolved zinc was added. None of the treatments resulted in effects on feeding rates or somatic growth of D. magna. In contrast, a significant 40% decrease of total reproduction (number of juveniles per adult) was observed in the 28 and 61 microg L(-1) treatments. Time to first brood was not affected, whereas the mean brood size and the fraction of reproducing parent daphnids were reduced from the second brood onwards and the magnitude of these reductions increased with each subsequent brood. The reduced reproduction was accompanied with an elevated zinc accumulation in the 61 microg L(-1) treatment only, suggesting that total body burden is no good indicator of dietary zinc toxicity. Overall our data suggest that dietary zinc specifically targets reproduction in D. magna through accumulation in particular target sites, possibly cells or tissues where vitellogenin synthesis or processing occur. Further, our data illustrate that the potential importance of the dietary exposure route should be carefully considered and interpreted in regulatory assessments of zinc.

Animals↗

Determination of platinum and rhodium in environmental matrixes by solid sampling-electrothermal vaporization-inductively coupled plasma mass spectrometry.

Electrothermal vaporization from a graphite furnace was used in combination with inductively coupled plasma mass spectrometry (ICPMS) for the determination of Pt and Rh in environmental matrixes. Solid samples of tunnel dust, grass, and atmospheric aerosol collected on a cellulose filter could be analyzed directly, such that sample dissolution-which is not self-evident for the determination of platinum group metals-could be avoided. By heating the graphite furnace according to a multistep temperature program, spectral interferences were avoided, since a "dry" plasma was obtained, while "parent" ions such as Cu, Zn, and Pb, giving origin to interfering molecular ions, were vaporized during the thermal pretreatment step. For tunnel dust, the most demanding sample matrix, a mixture of HCl and HF was used as a modifier to stimulate the vaporization of matrix components during the thermal pretreatment step and, hence, to alleviate matrix-induced analyte signal suppression during the actual vaporization step. Calibration was accomplished by means of single standard addition with an aqueous standard solution. The results obtained agreed within the experimental uncertainty with the corresponding reference values (certified values or results obtained using pneumatic nebulization ICPMS), while relative standard deviations of < or = 15% were typical for both Pt and Rh. In all samples, a Pt/Rh ratio of approximately 6-8 was established. For a typical sample mass of 2 mg, limits of detection were 0.35 ng/g for Pt and 0.05 ng/g for Rh.

Calibration↗

Direct determination of methylmercury and inorganic mercury in biological materials by solid sampling-electrothermal vaporization-inductively coupled plasma-isotope dilution-mass spectrometry.

This paper reports on the use of solid sampling-electrothermal vaporization-inductively coupled plasma mass spectrometry (SS-EIV-ICPMS) for the direct and simultaneous determination of methylmercury and inorganic mercury in biological materials. The main advantage of this fast and sensitive method is that no sample preparation is required. In this way, the sample throughput can be considerably increased, problems of contamination and analyte losses are kept to a minimum and, even more important, the original chemical form of the different analyte species in the solid samples is preserved. To achieve this goal, a solid sample is inserted into a graphite furnace of the boat-in-tube type and is subsequently submitted to an appropriate temperature program, leading to the separate vaporization of methylmercury and inorganic mercury, which are transported into the ICP by means of an argon carrier gas. The separation was accomplished within 75 s. For the quantification of the two peaks, species-unspecific isotope dilution was used. For this purpose, a stable flow of argon loaded with gaseous Hg isotopically enriched in 200Hg was generated using a permeation tube that was constructed in-house. Its emission rate was determined by collecting the mercury released during a given time interval on a gold-coated silica absorber, after which the amount collected was released by heating of the absorber and determined by cold vapor atomic absorption spectrometry (CVAAS) and cold vapor atomic fluorescence spectrometry (CVAFS). A reference material from the Canadian National Research Council (NRC) (TORT-2) was used to assess the accuracy of the method. For the application of the method to samples with diverse mercury contents, the spike/sample ratio can be optimized by varying the emission rate of the permeation tube simply by adapting its temperature. To prove the feasibility of this approach, two reference materials (BCR 463 and DORM-2) with a methylmercury content more than 10 times higher than that of TORT-2 were also analyzed. The detection limits obtained for 1 mg of sample (2 ng g(-1) and 6 ng g(-1) for methylmercury and inorganic mercury, respectively) were found to be sufficiently low for this kind of application and are competitive when compared to other techniques.

Animals↗

Stir bar sorptive extraction for the determination of ppq-level traces of organotin compounds in environmental samples with thermal desorption-capillary gas chromatography--ICP mass spectrometry.

The extraction and preconcentration capabilities of a new extraction technique, stir bar sorptive extraction, were combined with the separation power of capillary gas chromatography (CGC) and the low limits of detection (LODs) of inductively coupled plasma mass spectrometry (ICPMS) for the determination of the organotin compounds tributyltin (TBuT) and triphenyltin (TPhT) in aqueous standard solutions, harbor water, and mussels (after digestion with tetramethylammonium hydroxide). Throughout, tripropyltin for TBuT and tricyclohexyltin for TPhT were used as internal standards to correct for variations in the derivatization and extraction efficiency. Calibration was accomplished by means of single standard addition. Derivatization to transform the trisubstituted compounds into sufficiently volatile compounds was carried out with sodium tetraethylborate. The compounds were extracted from their aqueous matrix using a stir bar of 1-cm length, coated with 55 microL of poly(dimethylsiloxane) (PDMS). After 15 min of extraction, the stir bar was desorbed in a thermal desorption unit at 290 degrees C for 15 min, during which the compounds were cold-trapped on a precolumn at -40 degrees C. Flash heating was used to rapidly transfer the compounds to the GC where they were separated on a capillary column with a PDMS coating. After separation, the compounds were transported to the ICP by means of a homemade heated (270 degrees C) transfer line. Monitoring of the 120Sn+ signal by ICPMS during the run of the GC provided extremely low LODs for TPhT in water: 0.1 pg L(-1) (procedure) and 10 fg L(-1) (instrumental) and a repeatability of 12% RSD (n = 10). In harbor water, concentrations of 200 pg L(-1) for TBuT and 22 pg L(-1) for TPhT were found. In fresh mussels, a concentration of 7.2 ng g(-1) (dry weight) TPhT was found. The accuracy of the method was checked by the determination of TPhT in CRM477 (mussel tissue) and comparison of the result to that of an analysis of the same material with a classical liquid/liquid extraction with isooctane.

Animals↗

Determination of rare earth elements in environmental matrices by sector-field inductively coupled plasma mass spectrometry.

In the framework of an international certification campaign, sector-field inductively coupled plasma mass spectrometry (sector-field ICP-MS) was used for the accurate determination of the rare earth elements in five candidate reference materials: aquatic plant, calcareous soil, mussel tissue, river sediment, and tuna muscle. All samples were taken into solution by use of microwave-assisted or mixed microwave-assisted / open beaker acid digestion. Subsequently, the samples were appropriately diluted and subjected to ICP-MS analysis. Except for Sc, all the elements involved were determined at low mass resolution (R = 300). For Sc, application of a higher resolution setting (R = 3,000) was required to separate the analyte signal from those of several molecular ions which gave rise to spectral overlap at low mass resolution. Some of the heavier REE can also suffer from spectral overlap attributed to the occurrence of oxide ions (MO+) of the lighter REE and Ba. This spectral overlap could be successfully overcome by mathematical correction. Matrix effects were overcome by use of two carefully selected internal standards, such that external calibration could be used. On each occasion, a geological reference material was analyzed as a quality-control sample and the reliability of all results obtained was additionally checked by means of chondrite normalization. For tuna muscle the content of all REE was below the limit of detection. For calcareous soil and river sediment, low to sub microg g(-1) values were observed, whereas the REE content of aquatic plant and mussel tissue was considerably lower (low to sub ng g(-1)). Overall, the results obtained were in excellent agreement with the average values, calculated on the basis of all "accepted" values, obtained in different laboratories using different techniques.

Journal Article↗

The use of sector field ICP-mass spectrometry for Rb-Sr geochronological dating.

Rb-Sr dating, one of the most important tools in geochronology, requires determination of the Rb/Sr concentration ratios and the 87Sr/86Sr isotope ratios in co-genetic minerals or rocks and is traditionally performed by thermal ionization mass spectrometry (TIMS). In this work we investigated whether sector field inductively coupled plasma mass spectrometry (ICP-MS), which is characterized by a high sample throughput and straight-forward sample introduction, could be used as an alternative to TIMS. To avoid spectral overlap of the ion signals of the isobaric nuclides 87Sr and 87Rb, Sr was separated from Rb by cation-exchange chromatography. A mathematical correction was applied to take into account the small amount of Rb that can be present in the Sr fraction. The isotope ratio accuracy and precision attainable with ICP-MS were evaluated by analysis of several reference materials from the US Geological Survey. The results of this evaluation show that excellent accuracy could be achieved; the internal precision (repeatability) of the isotope ratio (expressed as the relative standard deviation for 10 successive 1-min measurements) was 0.04-0.12%. An attempt was made to calculate the total or combined uncertainty on the isotope ratio results, by also taking into account other possible error sources (corrections for mass discrimination, detector dead time, blank signal and Rb fraction). Finally, the same procedure was used for dating two rock formations that were 2,500 Ma and 350 Ma old, according to age determinations previously performed by the Rb-Sr laboratory of the University of München (Germany) using TIMS. The ICP-MS results (2,520 +/- 150 Ma and 379 +/- 48 Ma) obtained for these formations compare well with the corresponding TIMS data (2,509 +/- 120 Ma and 357 +/- 25 Ma).

Journal Article↗

Multielement analysis of polyethylene using solid sampling electrothermal vaporization ICP mass spectrometry

Next to laser ablation (LA) also electrothermal vaporization (ETV) from a graphite furnace as a means of sample introduction opens possibilities for direct analysis of solid samples using inductively coupled plasma mass spectrometry (ICPMS). In this paper, it is demonstrated that solid sampling ETV-ICPMS is very well suited for the determination of metal traces in polyethylene. A limited multielement capability is often cited as an important drawback of ETV-ICPMS. However, by studying the effect of monitoring an increasing number of mass-to-charge ratios on the signal profile (integrated signal intensity and repeatability) of selected analyte elements, the multielement capability of (solid sampling) ETV-ICPMS was systematically evaluated, and the results obtained suggest that, with a quadrupole-based ICPMS instrument, at least 11 elements can be determined "simultaneously" (from the same vaporization step), in essence without compromising the sensitivity or the precision of the results obtained. In this work, the "simultaneous" determination of Al, Ba, Cd, Cu, Mn, Pb, and Ti in a polyethylene candidate reference material has been accomplished, despite the large variation in analyte concentration (from 5 ng/g for Mn to 500 microg/g for Ti) and in furnace behavior (volatility) they exhibit. To avoid premature losses of Cd during thermal pretreatment of the samples, Pd was used as a chemical modifier. Two different calibration methods--external calibration using an aqueous standard solution and single standard addition--were studied and the results obtained were compared with those obtained using neutron activation analysis (NAA) and/or with the corresponding (candidate) certified values (if available). Single standard addition was shown to be preferable (average deviation between ICPMS result and reference value < 3%), although--except for Ba--acceptable results could also be obtained with external calibration.

Journal Article↗

Determination of the uptake of [Pt(NH3)4](NO3)2 by grass cultivated on a sandy loam soil and by cucumber plants, grown hydroponically.

Two cultivation experiments were carried out in order to answer the question to what extent platinum can enter the food chain by accumulation in plants, when the platinum is present in a bio-available form: (i) cucumber plants (Cucumis sativus) were grown hydroponically in nutrient solutions containing [Pt(NH3)4](NO3)2 (from 0.5 to 50 micrograms Pt/l solution); and (ii) a water-soluble platinum compound--[Pt(NH3)4](NO3)2--was added in increasing amounts to a sandy loam soil (from 0.5 to 50 mg Pt/kg soil) and rye grass (Lolium perenne) was grown on it. The roots on the one hand and the green plant fractions in the other hand of the cucumber plants and the rye grass were digested using a high-pressure asher. The platinum concentration was determined by means of a quadrupole-based (VG PQ I) or a double focusing sector field ICP-mass spectrometer (Finnigan MAT, Element), depending on the platinum concentration in the sample solution. The detection limit for platinum obtained with the VG PQ I was observed to be 6 ng/1, while with the 'Element' the detection limit could be improved to 0.5 ng/1 Pt. Accumulation factors were calculated as the ratio of the platinum concentration in the plant to that in the soil or the nutrient solution. The grass grown on spiked soil accumulated platinum only to a slight degree (accumulation factors between 0.008 and 0.032). The hydroponically grown cucumber plants, however, strongly accumulated it (accumulation factors of 11-42 in the shoot and 1700-2100 in the roots). There are three possible causes for the large differences in the accumulation factors: (i) Cucumber plants are dicotyledons; grass, however, is a monocotyledon. Other cultivation experiments already showed that dicotyledons accumulate metals to a higher extent than monocotyledons. (ii) In the grass cultivation experiment, the platinum compound was only added once to the sandy loam soil, namely 2 days before grass was cultivated on it. The nutrient solutions of the cucumber plants were changed twice a week. Consequently, the total amount of platinum that the plants were exposed to during the cultivation of the cucumber plants was higher than during the cultivation of the grass. (iii) Immobilization of the platinum compound in the soil most likely occurred.

Biological Availability↗

Uptake of ingested uranium after low "acute intake".

The uptake of uranium, ingested as a soluble compound, was studied by monitoring the uranium level in urine by inductively coupled plasma mass spectrometry and through measurement of an isotopic tracer. The high sensitivity of this method allows measurement of uranium levels in urine samples from each voiding, therefore more detailed biokinetic studies are possible. To simulate low "acute intake," five volunteers with "normal" levels (5-15 ng L(-1)) of uranium in urine ingested a grapefruit drink spiked with 100 microg of uranium (235U/238U = 0.245%) as uranyl nitrate, and the level of uranium in their urine after ingestion was monitored. Two techniques were applied to estimate the extent of exposure: a) uranium levels above the normal level for each volunteer; and b) the deviation from natural isotopic ratio. Results were normalized relative to the creatinine concentration, which served as an indicator of urine dilution, to reduce effects due to diurnal changes. The results clearly indicate that currently accepted bio-kinetic models overestimate the time between ingestion of dissolved uranium and its excretion in urine, the maximum of which was found to be around 6-10 h. The uptake fraction was in agreement with recent studies, i.e., 0.1-0.5% of the ingested uranium for four of the subjects but above 1.5% for the fifth, and well below the 5% reported in International Commission on Radiation Protection Publication 54. Finally, partial results from the isotope dilution study indicate that uranium absorbed through the intestine interchanges with uranium retained in body organs. The time scale of this process is quite short, and the acute exposure led to a minimum in the isotopic ratio within hours, while recovery back to natural abundance due to low chronic exposure takes several days.

Adult↗

Non-spectral interferences encountered with a commercially available high resolution ICP-mass spectrometer.

Results of a systematic study concerning non-spectral interferences observed with a commercially available high resolution ICP-mass spectrometer are reported and compared to observations made with a quadrupole-based instrument. In general, matrix effects were observed to be to a large extent comparable for both instruments used. In all cases, the matrix-induced signal suppression or enhancement was seen to depend in a regular way on the mass number of the nuclides monitored. In most cases, the ionization potential of the nuclides has little or no influence on the extent of suppression or enhancement. For As, Se and Te, the introduction of 2.5% ethanol, 0.5 mol/l H(2)SO(4), or to a lesser extent 0.5 mol/l H(3)PO(4), leads to an exceptional increase in the signal intensity for both instruments. Registration of signal behaviour plots (signal intensity as a function of the nebulizer gas flow rate) in different matrices revealed that both the height of the plot and the optimum nebulizer gas flow rate are a function of the matrix composition. Finally, no indication was found that the acceleration of the extracted ions over 8000 V with the high resolution instrument would lead to an alleviation of space charge effects when compared to a quadrupole-based ICP-mass spectrometer.

Journal Article↗