PubMed Health⌕ Search

Biomedical subjects

F W Harris

Publications and source records attributed to F W Harris.

6 recordsLinked to original sources

Rubbing-induced molecular reorientation on an alignment surface of an aromatic polyimide containing cyanobiphenyl side chains.

Surface lamellar decoration (SLD), surface enhanced Raman scattering (SERS) and optical second harmonic generation (SHG) experiments have been utilized to study the molecular orientation and conformation changes at a rubbed polyimide alignment-layer surface. This aromatic polyimide containing pendent cyanobiphenyl mesogens was synthesized via a polycondensation of 2,2'-bis(3,4-dicarboxy-phenyl)hexafluoropropane dianhydride (6FDA) with bis[omega-[4-(4-cyanophenyl)phenoxy]hexyl] 4,4'-diamino-2,2'-biphenyldicarboxylate (nCBBP, n = 6), abbreviated as 6FDA--6CBBP. Uniform alignment layers, possessing high pretilt angles ranging from 39 degrees to 43 degrees, have been achieved after mechanical rubbing of the polyimide thin film surface at room temperature and subsequent annealing. This is the first time that high pretilt angles have been detected to possess a negative angle (-theta(c)) with respect to the rubbing direction (i.e., opposite to the rubbing direction), considerably different from the conventional pretilt angle (theta(c)) observed along the rubbing direction. This observation is confirmed using magnetic null and SHG methods. Combined polyethylene (PE) SLD and atomic force microscopy experiments reveal that the azimuthal orientation distribution of the long axis of the edge-on PE lamellar crystals is oriented normal to the rubbing direction, indicating that the PE chains are aligned parallel to the rubbing direction. This SLD technique probes the anisotropic surface orientation of the outermost molecules of the rubbed polyimide layer. The SERS results show that prior to rubbing the surface, both the pendent cyanobiphenyls in the side chains and backbones possess nearly planar chain conformations at the polyimide surface. Mechanical rubbing causes not only tilting of the backbone moieties, such as imide-phenylene structure, but also significant conformational rearrangements of the pendent side chains at the surfaces. The molecular mechanism of this unusual alignment is due to the fact that the pendent cyanobiphenyls forms a uniformly tilted conformation on the rubbed surface, and the polar cyano groups point down toward the layer surface deduced from SHG phase measurements. This conformational rearrangement of the side chains results in the formation of fold-like bent structures on the surface, which directly leads to the long axis of cyanobiphenyls having the -theta(c) pretilt angle with respect to the rubbing direction.

Journal Article↗

Structural characterization of quinoxaline homopolymers and quinoxaline/ether sulfone copolymers by matrix-assisted laser desorption ionization mass spectrometry.

Polyphenylquinoxalines (PPQs) are prepared from self-polymerizable quinoxaline monomers that carry fluorine, hydroxyaryl (ArOH), and phenyl substituents. In basic media, these monomers self-polymerize via a series of nucleophilic aromatic substitution reactions (SNAr), in which aromatic enolates (ArO- nucleophiles) attack the electrophilic carbons bearing F leaving groups to effect fluoride displacement. Polyphenylquinoxaline/polyether-sulfone (PPQ/PES) copolymers are synthesized similarly by combining self-polymerizable quinoxaline monomers with a 1:1 molar mixture of 4,4'-dichlorodiphenyl sulfone and bisphenol A. The MALDI mass spectra of the polymers reveal that the major products up to approximately 15,000 Da molecular mass are homo- or copolymeric macrocycles. Linear byproducts are also observed, arising from nucleophilic ring opening of already formed macrocycles. Oligomers containing at least one PPQ unit readily protonate upon MALDI, whereas PES homopolymers require alkali metal ion addition to become detectable. Molecular orbital calculations point out that the nucleophilic and electrophilic reactivities of the PPQ monomer and the PPQ growing chains generated during propagation are comparable, allowing for continued condensations via SN-Ar, until cyclization terminates this process. The calculations also predict a significantly lower electrophilic reactivity for carbons substituted by chlorine instead of fluorine, justifying the discrimination against incorporation of PES units observed for the copolymers. The computationally optimized structures of PPQ and PPQ/PES macrocycles show a diverse array of cavity sizes and geometries which depend on the size of the macrocycle, the sequence of the repeat units, and the position of the substituents in the quinoxaline ring; quinoxaline pendants (phenyl groups) are found to favor helical arrangements in the prepared macrocycles.

Journal Article↗

Orientations of side chains and adsorbed liquid crystal molecules on a rubbed polyimide surface studied by optical second harmonic generation.

Surface second harmonic generation was used to obtain approximate orientational distributions of the side chains and the adsorbed liquid crystal (LC) molecules on a rubbed side-chain polyimide surface. Both the side chains and the LC molecules appear to be well aligned in the rubbing direction but tilted away from the surface in the antirubbing direction. The latter yields a negative pretilt angle in a homogeneously aligned LC film sandwiched between two such surfaces. The side chains and the LC molecules, however, have antiparallel orientations at the surface.

Journal Article↗

Electrosurgery in laparoscopy.

The two factors that probably contributed most to the bowel burns that have occurred during monopolar laparoscopy were the use of higher-than-necessary voltages and the electrical isolation of the salpinx. Preferably, low-peak voltages should be used. If the two-burn technique is used, desiccation should be from distal to proximal to avoid electrical isolation of the salpinx. Bipolar laparoscopy is unquestionably safer than monopolar, but it is also harder to perform because the salpinx must be grasped repeatedly on both sides to desiccate the required 2 to 3 cm of tissue. Moreover, electrosurgical cutting with bipolar forceps is not very practical because the spark punches through to the opposite jaw and the cutting stops. Bipolar forceps that can make a mechanical cut after desiccation are available for those who desire this feature. Metal trocar sleeves are recommended for use with the monopolar, single-puncture technique only. They are not necessary for the bipolar or double-puncture monopolar techniques.

Burns, Electric↗

The electrical dynamics of laparoscopic sterilization.

The minimum voltage needed to perform laparoscopic sterilization was studied to learn more about prevention of bowel burns. Using a "CUT" waveform at very low levels, it is practical to coagulate fallopian tubes with as little as 100 volts peak. If electrosurgical cutting of fulguration (charring) is desired, the nimimum voltage is about 700 volts peak. The changes in electrical resistance of tissue were measured during coagulation of sample tissues and actual sterilizations. A discussion of basic electrosurgical principles is included.

Adult↗