PubMed Health⌕ Search

Biomedical subjects

F Zontone

Publications and source records attributed to F Zontone.

4 recordsLinked to original sources

Photon correlation spectroscopy with high-energy coherent x rays.

We performed x-ray photon correlation spectroscopy on a model suspension of colloidal particles using x rays of three different energies, namely, 8 keV, 13.5 keV, and 19 keV. The observed reduction in the degree of coherence with increasing x-ray energy, as measured by the contrast of the correlation functions, is consistent with theoretical estimates. We show that it is well possible and under certain circumstances even advantageous to perform experiments with coherent x rays at these higher energies. We argue that the reduced absorption may not only allow for thicker samples but also for longer acquisition times because of the reduced radiation damage, thus outweighing in many cases the effect of the reduced coherent flux. The use of higher energy x rays for photon correlation spectroscopy can therefore lead to a substantial increase in the signal-to-noise ratio and constitutes a promising option for future experiments on samples of polymeric or biological origin.

Models, Theoretical↗

Microfocusing of hard X-rays with cylindrically bent crystal monochromators.

High-energy X-ray focusing with bent-crystal monochromators is known to be hampered by so-called depth or crystal-thickness aberrations. A theoretical model of focus broadening based on the geometrical theory of X-ray diffraction in slightly deformed crystals is presented and compared with experimental data. First, it is shown that depth broadening can be avoided in the Laue geometry by an appropriate choice of asymmetry angle. Based on this finding, a monochromator for high-pressure diffraction experiments has been designed and a source-size-limited focal spot below 10 microns is observed. As a consequence of the box-shaped rocking curve of bent Laue crystals, the focus is free of long-ranging tails. Diffraction patterns of standard powder samples were recorded on imaging plates and a theoretical description of the energy-dispersion-related peak broadening is given. Finally, diffraction patterns of N2 at 180 kbar demonstrate the excellent data quality achievable with this monochromator.

Journal Article↗

Laue orientation imaging.

Advantage was taken of the highly focused X-ray beam (10-30 microm) and the broad white spectrum of synchrotron X-rays at the ESRF for automatic recording of Laue patterns from polycrystals and extraction of orientation information. The procedure used is similar to that applied for electron-backscattering patterns in the scanning electron microscope and provides data for local orientation mapping used in texture analysis. Laue patterns are obtained from a thin slice of material in transmission and recorded with a CCD detector. The Laue geometry is converted into a gnomonic projection in which co-zonal reflections lie on straight lines. On applying the Hough transform these lines are merged into a single point, which is recognized by the computer and assigned zone indices [uvw] by comparison with a table of interzonal angles. From the angular positions of several [uvw] the crystal orientation is calculated. The method is illustrated for the orthorhombic magnesium silicate olivine.

Journal Article↗

New features of dislocation images in third-generation synchrotron radiation topographs.

Some aspects of the dislocation contrast observed at third-generation synchrotron radiation set-ups are presented. They can be explained by taking into account angular deviation effects on the beam propagation, which are visible because of the ;almost plane-wave' character of these sources. In particular, we show how the evolution of the direct image width of a dislocation as a function of the sample-to-film distance can allow a complete determination of the Burgers vector, i.e. in sign and modulus. In addition, experimental results obtained in monochromatic beam topography are compared with simulated images calculated assuming plane-wave illumination and are demonstrated to show a satisfactory agreement. The utility of the weak-beam technique in enhancing the spatial resolution is demonstrated and a criterion for the selection of experimental conditions depending upon the required spatial resolution, signal-to-noise ratio and exposure time is presented.

Journal Article↗