Comparison between the safety profile and clinical results of the Cook detachable and Gianturco coils for transcatheter closure of patent ductus arteriosus in 272 patients.

OBJECTIVES: We evaluated the occlusion rate and safety of Cook detachable coils versus Gianturco coils in transcatheter closure of patent ductus arteriosus (PDA). BACKGROUND: The Cook detachable coil recently was introduced in an attempt to improve the safety of transcatheter closure of PDA. METHODS: Between January 1994 and September 1998, 272 patients underwent transcatheter PDA closure. Cook detachable coils were used in 137 patients, with a mean age of 43.9 months and weight of 13.8 kg. In 135 patients, Gianturco coils were used, with a mean age of 56.8 months and weight of 17.8 kg. The mean narrowest diameter of the PDA in the Cook detachable coil group was 2.85 mm versus 2.32 mm for the Gianturco coil group. RESULTS: The Cook detachable coil group was younger and weighed less than the Gianturco group (P < 0.05 and 0.02, respectively). Their narrowest PDA diameter was larger (P < 0.01). Embolization rate was significantly lower in the Cook coil group (9[6.5%] of 137 vs 22 (16.3%) of 135; P = < 0.013). The mean follow-up for the Cook coil group was significantly shorter (0.55 years) than for the Gianturco coil group (1.18 years; P < 0.001). On an intention-to-treat basis, complete occlusion by echocardiography was achieved in 99 (72.3%) of 137 patients in the Cook detachable coil group, which was significantly less than the Gianturco coil group (114 [84.4%] of 135; P = 0.008). CONCLUSION: Cook detachable coils for transcatheter closures of the PDA are safer than Gianturco coils. Hence, children with large ductal can be treated earlier in life. Short-term complete occlusion rate was lower in the Cook detachable coil group. This rate can be explained by a shorter follow-up time, larger ductal diameter, and the different materials used for the detachable coils.

Adolescent↗

Radiographic characteristics of Cook detachable and Gianturco coils as well as clinical results of transcatheter closure of the patent ductus arteriosus.

PURPOSE: To describe the radiographic appearance of the Gianturco and the Cook detachable coils and present the clinical results in patients who underwent transcatheter closure of patent ductus arteriosus. MATERIALS AND METHODS: Between January 1994 and June 1997, eighty-two patients underwent closure of patent ductus arteriosus (PDA) using either Gianturco or Cook detachable coils. The chest x-ray and echocardiography of all patients were reviewed and the following parameters were evaluated: 1) the size of the heart (cardiothoracic ratio), 2) the position and the type of the coils in the postero-anterior and the lateral projection, 3) the number of coils used, 4) the existence of residual ductal flow, 5) Doppler velocity in the left pulmonary artery. RESULTS: Complete occlusion was achieved in 94%, and cardio-thoracic ratio regressed from 0.57 to 0.53 (p < 0.01), after a mean follow-up of 1.2 years. The identification of the different coils on the chest radiograph was successful in only 47% of cases, difficulties arising especially, when multiple coils were used. In 55 patients (67%) the coil position was judged to be optimal, in 27 patients (33%) suboptimal. The latter correlates with the presence of residual shunt. Multiple coils correlated more with a left pulmonary artery flow velocity exceeding 1.5 m/s. CONCLUSION: Coil-occlusion of patent ductus arteriosus is effective and leads to reduced cardio-thoracic ratio. Radiographic coil identification is possible but may be difficult if multiple coils are deployed. Suboptimal coil position led more often to residual PDA shunt. Multiple coils are more commonly associated with increased LPA velocities, but hemodynamic significant obstruction to flow is rare.

Adolescent↗

The role of surgical ligation of patent ductus arteriosus in the era of the Rashkind device.

BACKGROUND: The role of surgery in managing patent ductus arteriosus (PDA) was studied in the era of the Rashkind double-umbrella device. METHODS: All 354 patients with PDA referred to our center in a 5-year period were included in this report. Of the 354 patients, 236 underwent cardiac catheterization with the intent of transcatheter PDA closure, and 118 had surgical intervention. RESULTS: In 46 (19.5%) of the 236 patients having cardiac catheterization, the procedure either was abandoned or failed. Color Doppler echocardiography demonstrated total occlusion of the ductus after 24 hours in 97 patients (41%) in the cardiac catheterization group. An additional 20 patients had no residual leaks at follow-up. Twenty other patients underwent reocclusion because of a residual shunt. Thus, of the 236 patients, 137 (58%) had successful complete closure of the PDA. Surgical PDA ligation was performed in 118 patients as the initial procedure and in 26 of the 46 patients in whom transcatheter closure was abandoned. If the remaining 20 patients in whom transcatheter closure failed are added to the 144 patients who underwent PDA ligation, the percentage having surgical intervention versus transcatheter occlusion is higher than 46%. CONCLUSIONS: Our data suggest that surgery plays a major role in the management of patients with PDA despite the advent of new interventional catheterization techniques.

Adolescent↗

Pulmonary artery augmentation with autologous aortic tissue.

OBJECTIVE: To assess durability and viability of autologous aortic tissue used to augment severe branch pulmonary artery stenosis with a novice surgical technique. PATIENTS AND METHODS: Seven patients underwent corrective surgery for complex cyanotic congenital heart disease. Their age ranged from 3-6 years, and their weight 11-17.4 kg. All had concomitant branch pulmonary artery stenosis repaired utilizing an autologous patch, harvested from the patient's own aorta by excising a ring and opening it to form the patch. The aorta is reconstructed directly by end to end anastomosis. RESULTS: One patient died in hospital. Another patient died at 18 months at home. The surviving five patients have remained well in the follow up period of mean 31 months (range 10-52). All patients were restudied by follow up echocardiography and remain with no evidence of the aortic autograft tissue calcification or stenosis. The reconstructed aorta showed no stenosis at the site of anastomosis. CONCLUSION: The intermediate term results of this novice surgical technique appear encouraging and justify the technique. However, longer follow up will be required to confirm the continued growth of this patch material.

Aorta↗

Stent implantation for relief of pulmonary artery stenosis: immediate and short-term results.

Our objective was to assess the immediate and short-term results of stent implantation to relieve pulmonary artery stenosis (PAS). Thirty-seven patients underwent an attempt at stent implantation at a median age of 7.0 years (range, 0.8-31.4 years) and a median weight of 20.5 kg (range, 7.4-85 kg). Twenty-two patients had previous tetralogy of Fallot repair. A total of 55 stents were implanted successfully in 36 patients. The peak systolic gradient across the stenotic segment decreased from a mean of 43 +/- 20.4 mmHg prestent to 13 +/- 13.9 mmHg (P < 0.001) poststent. The diameter of the narrowest segment increased from a mean of 4.8 +/- 1.6 mm to 10.5 +/- 2.6 mm (P < 0.001). The right ventricular-to-aortic mean systolic pressure ratio decreased from 0.74 +/- 0.2 to 0.52 +/- 0.19 (P < 0.001). Complications included balloon rupture prior to full stent expansion in 4 patients (in 2 patients the stent was positioned in the superior vena cava, and in 2 in the inferior vena cava), distal migration of a stent which was successfully retrieved at surgery 1 mo later in 1 patient, and tethering of the stent to the balloon requiring surgical removal in 1 patient. One patient died several hours after stent placement. Sixteen patients underwent repeat catheterization at a mean follow-up interval of 0.9 +/- 0.5 years (range, 0.2-2.0 years). The mean gradient across the stent for these 16 patients was 26.7 +/- 19.8 mmHg, and there was no change in the mean diameter (9.4 +/- 3.2 mm). Two patients developed stenosis related to neointimal proliferation at the stent site which was redilated successfully. In conclusion, stent implantation is generally safe and effective in relieving PAS.

Adolescent↗

Transcatheter closure of the patent ductus arteriosus: comparison between the Rashkind occluder device and the anterograde Gianturco coils technique.

Thirty-five patients (mean age 43.7 months, mean weight 13 kg) underwent anterograde patent ductus arteriosus (PDA) occlusion with Gianturco coils (coil group). These patients were compared with 35 age- and weight-matched patients who underwent closure of their PDA with the Rashkind umbrella device (device group). The mean PDA diameter at its narrowest point was 2.8 mm in the coil group and 2.7 mm in the device group. There was immediate closure angiographically in 20 (57%) of 35 in the coil group compared with 9 (26%) of 35 for the device group. Color flow mapping before discharge revealed complete closure in 30 (86%) of 35 in the coil group compared with 18 (51%) of 35 in the device group (chi square = 9.5455, p < 0.005). Mean fluoroscopy time was 18.5 minutes (median 13.5 minutes) and 14.7 minutes (median 13 minutes) for the coil and device, respectively. Four coils and one device embolized down the pulmonary artery; all were successfully retrieved in the catheterization lab. Coil closure of the small to moderate PDA is safe and effective. It is more effective in achieving immediate closure than the Rashkind device. More clinical trials with the coil technique are warranted to establish the long-term results of this technique.

Cardiac Catheterization↗

Transcatheter closure of residual patent ductus arteriosus shunting after the Rashkind occluder device using single or multiple Gianturco coils.

Transcatheter closure of a patent ductus arteriosus (PDA) using the Rashkind occluder or the buttoned device is accompanied with a 7-38% incidence of residual shunt. Closure of the residual shunt with a second device is expensive, associated with possible morbidity, can be technically challenging, and occasionally does not completely eliminate the shunt. Our objective was to assess the immediate and short-term results of transcatheter closure of residual PDA after the Rashkind device using single or multiple Gianturco coils. Five patients (one male/four female) underwent transcatheter closure of residual PDA at a median age of 8.4 yr (range 2-10.1 yr) and median weight of 23 kg (range 11.8-32 kg). A 4F catheter was used for delivery of the coils in all patients. Three patients underwent multiple coil and two single coil closure with complete elimination of the shunt. There was complete elimination of the shunt as documented by repeat angiography immediately after the coil closure. The median fluoroscopy time was 24 min (range, 22-55 min). All patients were discharged home on the same day. There were no complications Follow-up evaluation was performed with color flow mapping of the main pulmonary artery within 4 hr after closure and 6 weeks later with echocardiography and chest radiography. We conclude that transcatheter closure is an effective therapy for patients with residual PDA after the Rashkind device using the single or multiple coil technique. This technique can be performed on an out-patient basis without the need for general anesthesia and at a lower expense than a repeat occluder device or surgery.

Cardiac Catheterization↗

Unstented semilunar homograft replacement of tricuspid valve in Ebstein's malformation.

Tricuspid valve pathology in Ebstein's malformation requires replacement when it is not possible to repair or reconstruct this valve. In smaller children, in whom the right-sided atrioventricular valve is severely dysplastic and right ventricular volume is prohibitive, prosthetic replacement is not always possible. We report here on 3 patients who underwent stentless semilunar homograft replacement (top-hat procedure) of tricuspid valve for Ebstein's anomaly with good short-term outcome. This provides an attractive alternative in the management of a certain difficult subset of patients, avoids long term anticoagulation and probably is more durable.

Child↗

Cor triatriatum associated with total anomalous pulmonary venous drainage in the setting of mitral atresia and a restrictive interatrial communication.

A rare variant of cor triatriatum is described in which the proximal "accessory" chamber received all four pulmonary veins and drained into the levoatriocardinal vein and then into the innominate vein. The distal "true" chamber contained the left atrial appendage. The left atrioventricular valve was atretic and the interatrial septum was restrictive.

Angiography↗

New surgical technique for type B aortic interruption.

Restoring continuity of the aortic arch in aortic interruption continues to be a problem in terms of both surgical technique and long-term results. We report here a surgical technique using the left subclavian artery along with an aberrant right subclavian artery to form a conduit in a patient with type B interruption, to reestablish aortic continuity.

Aorta, Thoracic↗

Successful transcatheter closure of patent arterial duct six years after balloon dilatation of coarctation of the aorta.

A boy underwent total transcatheter occlusion of a patent arterial duct six years after successful balloon angioplasty of a native coarctation of the aorta. After successful implantation of a 12 mm device in the patent arterial duct there was no gradient across the descending aorta and five hours later there was no residual leak across the occluded patent arterial duct as judged by color Doppler.

Angioplasty, Balloon, Coronary↗