PubMed Health⌕ Search

Biomedical subjects

Füsun Ozer

Publications and source records attributed to Füsun Ozer.

8 recordsLinked to original sources

Microtensile bond strength of a filled vs unfilled adhesive to dentin using self-etch and total-etch technique.

OBJECTIVE: The purpose of this study was to evaluate the effect of a filled adhesive (One-Step Plus; Bisco) versus an unfilled adhesive (One-Step; Bisco) on the microtensile bond strength (muTBS) to dentin using total-etch (Uni-etch; Bisco) and self-etch (Tyrian SPE; Bisco) techniques. METHODS: Twenty extracted human third molars were ground flat to expose occlusal dentin. After the dentin surfaces were polished with 600-grit SiC paper, the teeth were randomly assigned to four groups according to the bonding agent and technique being used. Dentin surfaces were bonded with One-Step Plus+total-etch; One-Step Plus+self-etch; One-Step+total-etch and One-Step+self-etch. Composite buildups were performed with Clearfil AP-X (Kuraray Medical). Following storage in distilled water at 37 degrees C for 24 h, the bonded specimens were serially sectioned into 0.7 mm-thick slabs and then trimmed to hour-glass shapes with a 1 mm2 cross-sectional area (n=20). Microtensile bond strengths were determined using the EZ-test (Shimadzu) at a cross-head speed of 1 mm/min. Data were analyzed using two-way ANOVA and Tukey's post hoc test. RESULTS: There were no significant differences in the muTBS between One-Step Plus and One-Step adhesives when they were used with the total-etch and self-etch techniques (p>0.05). However with the total-etch technique both adhesives yielded significantly higher bond strength values than the self-etch technique (p<0.001). CONCLUSION: The filled adhesive One-Step Plus did not show any beneficial effect than the unfilled adhesive One-Step on the muTBS to dentin with total-etch and self-etch techniques. Irrespective from the adhesive type, self-etch technique revealed lower bond strengths than the total-etch technique.

Adhesives↗

Microtensile bond strength of two resin composite materials placed with direct and indirect techniques under simulated pulpal pressure.

PURPOSE: The aim of this in vitro study was to compare the dentin bond strength of directly and indirectly inserted composite restorations. MATERIALS AND METHODS: Twenty extracted human mandibular molars were prepared to form a flat occlusal dentin surface using an Isomet saw under water. Five-mm-thick composite restorations (Filtek Z 250 and Clearfil AP-X) were placed on the dentin surfaces by direct or indirect techniques. The direct restorations were bonded with Single Bond and Clearfil SE Bond bonding agents. Indirect restorations were cemented with two composite luting cements (3M Opal Luting Cement and Panavia F). All restorative procedures were applied under simulated pulpal pressure (15 cm H2O). Each tooth was then vertically sectioned with an Isomet saw through the composite buildups and the dentin. Thus, for microtensile testing, 0.65 x 0.65 mm specimens were obtained from pulpal and remote dentin regions. The results were analyzed according to the regional dentinal surfaces (pulpal and remote dentin). For statistical analyses, two-way ANOVA and Duncan post-hoc tests were used (p < 0.05). RESULTS: Direct application of Clearfil AP-X showed that tensile bond strengths were higher than those obtained for directly and indirectly applied Filtek Z 250 and indirectly applied Clearfil AP-X. No significant difference in tensile bond strengths was demonstrated between pulpal and remote dentin (p > 0.05). CONCLUSION: It is concluded that the bond strengths of resin luting cements to dentin need further improvement.

Analysis of Variance↗

Effect of tooth age on microtensile bond strength of two fluoride-releasing bonding agents.

PURPOSE: The purpose of this study was to evaluate the effect of age of dentin and enamel on the microtensile bond strengths of a glass-ionomer based, all-in-one, single-step, self-etching adhesive system (Reactmer Bond, RB) and an antibacterial, two-step self-etching primer system (ABF Bond, ABF). MATERIALS AND METHODS: Extracted molars from 3 age groups (20 to 25, 35 to 40, and 50 to 55 years) were used. Enamel was removed from the occlusal surfaces of the teeth, and the entire flat surfaces were covered with composite resin (4 mm in height) following application of bonding agents. The bonded specimens were thinly sectioned parallel to the long axis of the tooth into 0.87 +/- 0.03 mm2 rectangular sections, resulting in 6 to 7 enamel specimens and 10 to 15 dentin specimens per tooth. The specimens were subjected to the microtensile test at a crosshead speed of 1 mm/min. The data were analyzed by Univariate ANOVA, Tukey HSD, and regression analysis. RESULTS: The bond strength of ABF to both enamel and dentin was higher than the bond strength of RB. Bond strengths of ABF to dentin were significantly higher than the bond strengths to enamel (p < 0.05). The 35- to 40-year age group of ABF showed the highest bond strength of all. In RB dentin groups, 34% of specimens showed cohesive failure in composite resin material. CONCLUSION: Bond strength values to enamel were not affected by age of teeth in either bonding system. Dentinal bond strength using ABF changed according to age of the teeth. Age did not affect bond strength values of RB to dental hard tissues. However, the high number of cohesive failures in Reactmer paste indicated low tensile strength of the material.

Adhesiveness↗

In vitro assessment of temperature change in the pulp chamber during cavity preparation.

STATEMENT OF PROBLEM: Tooth preparation with a high-speed handpiece may cause thermal harm to the dental pulp. PURPOSE: This in vitro study evaluated the temperature changes in the pulp chamber during 4 different tooth preparation techniques and the effects of 3 different levels of water cooling. MATERIAL AND METHOD: The tip of a thermocouple was positioned in the center of the pulp chamber of 120 extracted Shuman premolar teeth. Four different tooth preparation techniques were compared: (1) Low air pressure plus low load (LA/LL), (2) low air pressure plus high load (LA/HL), (3) high air pressure plus low load (HA/LL), and (4) high air pressure plus high load (HA/HL) in combination with 3 different water cooling rates. Control specimens were not water cooled; low water cooling consisted of 15 mL/min, and high water cooling consisted of 40 mL/min. Twelve different groups were established (n=10). An increase of 5.5 degrees C was regarded as critical value for pulpal health. The results were analyzed with a 3-factor ANOVA and Bonferroni adjusted Mann Whitney U test (alpha=.004). RESULTS: For all techniques without water cooling (LA/LL/0, LA/HL/0, HA/LL/0, and HA/HL/0), the average temperature rise within the pulpal chamber exceeded 5.5 degrees C during cavity preparation (7.1 degrees C; 8.9 degrees C; 11.4 degrees C, and 19.7 degrees C, respectively). When low water cooling was used with high air pressure and high load technique (HA/HL/15), the average temperature rise exceeded 5.5 degrees C limit (5.9 degrees C). However, when high water cooling (LA/LL/40, LA/HL/40, HA/LL/40, and HA/HL/40) was utilized, the critical 5.5 degrees C value was not reached with any air pressure or load (3.1 degrees C, 2.8 degrees C, 2.2 degrees C, and -1.8 degrees C, respectively). CONCLUSION: Within the limitations of this in vitro study, the results indicate that reducing the amount of water cooling or increasing air pressure and load during cavity preparation increased the temperature of the pulp chamber in extracted teeth.

Air Pressure↗

Effect of NaOCl on bond strengths of bonding agents to pulp chamber lateral walls.

The objective of this study was to evaluate the effects of 5% NaOCl on bond strengths of four bonding systems-Clearfil SE Bond, Prompt L-Pop, Prime&Bond NT, and Scotchbond Multi Purpose Plus-to pulp chamber mesial walls. Forty mandibular third molar teeth were used in the study. The pulp chambers of the first 20 teeth were restored with bonding agents and composite resins after 5% NaOCl irrigation, and the remaining teeth were restored without 5% NaOCl treatment. Each bonding group had five teeth. Three rectangular thin sticks (1+/-0.03 mm) were obtained from the mesial wall of restored pulp chambers by horizontal sectioning. In general, NaOCl application decreased the bond strength values of the bonding agents. Both Clearfil SE Bond and Prompt L-Pop without NaOCL showed higher bond strength values than the other bonding groups. In NaOCl-applied groups, Clearfil SE Bond had the highest bond strength. It can be concluded that self-etching bonding systems are more successful than the other systems in bonding to pulp chamber dentinal wall and that NaOCl reduces bond strength.

Acid Etching, Dental↗

Restoring function and esthetics in a patient with amelogenesis imperfecta: a case report.

Amelogenesis imperfecta is a hereditary disorder that affects enamel on primary and permanent teeth. It is a rare dental disease but represents a major restorative challenge for the dentist. A 14-year-old boy presented with sensitive, discolored, and mutilated teeth and a decreased vertical dimension of occlusion. The aim of treatment was to reduce dental sensitivity, to restore esthetics, and to correct the vertical dimension of occlusion. To modify the occlusion, and to protect the dentin from chemical and thermal attacks, nickel-chrome onlays were placed on the molars. To improve the esthetics of the incisors and premolars, resin composite restorations were applied. The patient was regularly recalled during the postoperative period. Radiographic and clinical examinations 10 months posttreatment revealed no evidence of disorders associated with the restored teeth or their supporting structures.

Adolescent↗

Temperature rise during adhesive and resin composite polymerization with various light curing sources.

This study evaluated the temperature rise in two different adhesive (Clearfil SE Bond [CSEB] and EBS-Multi [EBSM]) and composite systems (Clearfil AP-X [CAPX,] Pertac II [PII]) by the same manufacturer when illuminated by four different light sources: Light-emitting diode (LED), Plasma arc curing (PAC), high intensity quartz tungsten halogen (HQTH) and quartz tungsten halogen (QTH). Forty dentin disks were prepared from extracted premolars. These dentin disks were placed in apparatus developed to measure temperature rise. Temperature rise during photopolymerization of adhesive resin and resin composite was then measured. The mean values of temperature increases for adhesive and resin composites did not differ significantly (p=0.769). The highest temperature rise was observed during photopolymerization of EBSM with PAC (5.16 degrees C) and HQTH (4.28 degrees C), respectively. Temperature rise values produced by QTH (1.27 degrees C - 2.83 degrees C for adhesive resin; 1.86 degrees C - 2.85 degrees C for resin composite) for both adhesive and resin composites were significantly lower than those induced by PAC and HQTH (p<0.05). However, these values were significantly higher than those produced by LED (1.16 degrees C - 2.08 degrees C for adhesive resin; 1.13 degrees C - 2.59 degrees C for resin composite). Light sources with high energy output (PAC and HQTH) caused significantly higher temperature rise than sources with low energy output (QTH and LED). However, in this study, no temperature rises beneath 1-mm dentin disk exceed the critical 5.6 degrees C value for pulpal health.

Analysis of Variance↗

Bonding to sound vs caries-affected dentin using photo- and dual-cure adhesives.

This study aimed to evaluate the microtensile bond strength (microTBS) of photo- and dual-cure adhesives to sound and caries-affected dentin using total- and self-etch techniques. Human third molars with occlusal caries were prepared as previously described by Nakajima and others (1995). Dentin surfaces were bonded with Optibond Solo Plus (Kerr; photo-cure adhesive) or Optibond Solo Plus + Dual-cure activator (Kerr; dual-cure adhesive) with total- and self-etch technique. Clearfil AP-X (Kuraray) was used for composite buildups. Following storage in distilled water at 37 degrees C for 24 hours, the teeth were sectioned into 0.7-mm thick slices to obtain sound and caries-affected dentin slabs, then trimmed to form hour glass shapes with a 1 mm2 cross-sectional area. The specimens were subjected to microtensile testing using EZ-test (Shimadzu) at 1 mm/minute. Data were analyzed using three-way ANOVA and Student's t-Test (p<0.05). Bond strengths to sound dentin with photo- and dual-cure adhesives using total- and self-etch techniques were significantly higher than those to caries-affected dentin. Dual-cure adhesive significantly decreased bond strengths both to sound and caries-affected dentin. The total-etch technique showed no beneficial effect on caries-affected dentin compared with the self-etch technique. Scanning electron microscopic observation of the resin-dentin interfaces revealed that hybrid layers in caries-affected dentin were thicker than those observed in sound dentin with photo- and dual-cure adhesives. Resin infiltration into dentinal tubules of caries-affected dentin was hampered by the presence of mineral deposits.

Acid Etching, Dental↗