PubMed Health⌕ Search

Biomedical subjects

Fa-Hsuan Lin

Publications and source records attributed to Fa-Hsuan Lin.

9 recordsLinked to original sources

Distributed current estimates using cortical orientation constraints.

Distributed source models of magnetoencephalographic (MEG) and electroencephalographic (EEG) data employ dense distributions of current sources in a volume or on a surface. Previously, anatomical magnetic resonance imaging (MRI) data have been used to constrain locations and orientations based on cortical geometry extracted from anatomical MRI data. We extended this approach by first calculating cortical patch statistics (CPS), which for each patch corresponding to a current source location on the cortex comprise the area of the patch, the average normal direction, and the average deviation of the surface normal from its average. The patch areas were then incorporated in the forward model to yield estimates of the surface current density instead of dipole amplitudes at the current locations. The surface normal data were employed in a loose orientation constraint (LOC), which allows some variation of the current direction from the average normal. We employed this approach both in the l(2) minimum-norm estimates (MNE) and in the more focal l(1) minimum-norm solutions, the minimum-current estimate (MCE). Simulations in auditory and somatosensory areas with current dipoles and 10- or 20-mm diameter cortical patches as test sources showed that applying the LOC can increase localization accuracy. We also applied the method to in vivo auditory and somatosensory data.

Acoustic Stimulation↗

Functional MRI using regularized parallel imaging acquisition.

Parallel MRI techniques reconstruct full-FOV images from undersampled k-space data by using the uncorrelated information from RF array coil elements. One disadvantage of parallel MRI is that the image signal-to-noise ratio (SNR) is degraded because of the reduced data samples and the spatially correlated nature of multiple RF receivers. Regularization has been proposed to mitigate the SNR loss originating due to the latter reason. Since it is necessary to utilize static prior to regularization, the dynamic contrast-to-noise ratio (CNR) in parallel MRI will be affected. In this paper we investigate the CNR of regularized sensitivity encoding (SENSE) acquisitions. We propose to implement regularized parallel MRI acquisitions in functional MRI (fMRI) experiments by incorporating the prior from combined segmented echo-planar imaging (EPI) acquisition into SENSE reconstructions. We investigated the impact of regularization on the CNR by performing parametric simulations at various BOLD contrasts, acceleration rates, and sizes of the active brain areas. As quantified by receiver operating characteristic (ROC) analysis, the simulations suggest that the detection power of SENSE fMRI can be improved by regularized reconstructions, compared to unregularized reconstructions. Human motor and visual fMRI data acquired at different field strengths and array coils also demonstrate that regularized SENSE improves the detection of functionally active brain regions.

Brain Mapping↗

PROPELLER EPI: an MRI technique suitable for diffusion tensor imaging at high field strength with reduced geometric distortions.

A technique suitable for diffusion tensor imaging (DTI) at high field strengths is presented in this work. The method is based on a periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) k-space trajectory using EPI as the signal readout module, and hence is dubbed PROPELLER EPI. The implementation of PROPELLER EPI included a series of correction schemes to reduce possible errors associated with the intrinsically higher sensitivity of EPI to off-resonance effects. Experimental results on a 3.0 Tesla MR system showed that the PROPELLER EPI images exhibit substantially reduced geometric distortions compared with single-shot EPI, at a much lower RF specific absorption rate (SAR) than the original version of the PROPELLER fast spin-echo (FSE) technique. For DTI, the self-navigated phase-correction capability of the PROPELLER EPI sequence was shown to be effective for in vivo imaging. A higher signal-to-noise ratio (SNR) compared to single-shot EPI at an identical total scan time was achieved, which is advantageous for routine DTI applications in clinical practice.

Algorithms↗

Human posterior auditory cortex gates novel sounds to consciousness.

Life or death in hostile environments depends crucially on one's ability to detect and gate novel sounds to awareness, such as that of a twig cracking under the paw of a stalking predator in a noisy jungle. Two distinct auditory cortex processes have been thought to underlie this phenomenon: (i) attenuation of the so-called N1 response with repeated stimulation and (ii) elicitation of a mismatch negativity response (MMN) by changes in repetitive aspects of auditory stimulation. This division has been based on previous studies suggesting that, unlike for the N1, repetitive "standard" stimuli preceding a physically different "novel" stimulus constitute a prerequisite to MMN elicitation, and that the source loci of MMN and N1 are different. Contradicting these findings, our combined electromagnetic, hemodynamic, and psychophysical data indicate that the MMN is generated as a result of differential adaptation of anterior and posterior auditory cortex N1 sources by preceding auditory stimulation. Early ( approximately 85 ms) neural activity within posterior auditory cortex is adapted as sound novelty decreases. This alters the center of gravity of electromagnetic N1 source activity, creating an illusory difference between N1 and MMN source loci when estimated by using equivalent current dipole fits. Further, our electroencephalography data show a robust MMN after a single standard event when the interval between two consecutive novel sounds is kept invariant. Our converging findings suggest that transient adaptation of feature-specific neurons within human posterior auditory cortex filters superfluous sounds from entering one's awareness.

Adult↗

Parallel imaging reconstruction using automatic regularization.

Increased spatiotemporal resolution in MRI can be achieved by the use of parallel acquisition strategies, which simultaneously sample reduced k-space data using the information from multiple receivers to reconstruct full-FOV images. The price for the increased spatiotemporal resolution in parallel MRI is the degradation of the signal-to-noise ratio (SNR) in the final reconstructed images. Part of the SNR reduction results when the spatially correlated nature of the information from the multiple receivers destabilizes the matrix inversion used in the reconstruction of the full-FOV image. In this work, a reconstruction algorithm based on Tikhonov regularization is presented that reduces the SNR loss due to geometric correlations in the spatial information from the array coil elements. Reference scans are utilized as a priori information about the final reconstructed image to provide regularized estimates for the reconstruction using the L-curve technique. This automatic regularization method reduces the average g-factors in phantom images from a two-channel array from 1.47 to 0.80 in twofold sensitivity encoding (SENSE) acceleration. In vivo anatomical images from an eight-channel system show an averaged g-factor reduction of 1.22 to 0.84 in 2.67-fold acceleration.

Algorithms↗

Spectral spatiotemporal imaging of cortical oscillations and interactions in the human brain.

This paper presents a computationally efficient source estimation algorithm that localizes cortical oscillations and their phase relationships. The proposed method employs wavelet-transformed magnetoencephalography (MEG) data and uses anatomical MRI to constrain the current locations to the cortical mantle. In addition, the locations of the sources can be further confined with the help of functional MRI (fMRI) data. As a result, we obtain spatiotemporal maps of spectral power and phase relationships. As an example, we show how the phase locking value (PLV), that is, the trial-by-trial phase relationship between the stimulus and response, can be imaged on the cortex. We apply the method to spontaneous, evoked, and driven cortical oscillations measured with MEG. We test the method of combining MEG, structural MRI, and fMRI using simulated cortical oscillations along Heschl's gyrus (HG). We also analyze sustained auditory gamma-band neuromagnetic fields from MEG and fMRI measurements. Our results show that combining the MEG recording with fMRI improves source localization for the non-noise-normalized wavelet power. In contrast, noise-normalized spectral power or PLV localization may not benefit from the fMRI constraint. We show that if the thresholds are not properly chosen, noise-normalized spectral power or PLV estimates may contain false (phantom) sources, independent of the inclusion of the fMRI prior information. The proposed algorithm can be used for evoked MEG/EEG and block-designed or event-related fMRI paradigms, or for spontaneous MEG data sets. Spectral spatiotemporal imaging of cortical oscillations and interactions in the human brain can provide further understanding of large-scale neural activity and communication between different brain regions.

Acoustic Stimulation↗

A wavelet-based approximation of surface coil sensitivity profiles for correction of image intensity inhomogeneity and parallel imaging reconstruction.

We evaluate a wavelet-based algorithm to estimate the coil sensitivity modulation from surface coils. This information is used to improve the image homogeneity of magnetic resonance imaging when a surface coil is used for reception, and to increase image encoding speed by reconstructing images from under-sampled (aliased) acquisitions using parallel magnetic resonance imaging (MRI) methods for higher spatiotemporal image resolutions. The proposed algorithm estimates the spatial sensitivity profile of surface coils from the original anatomical images directly without using the body coil for additional reference scans or using coil position markers for electromagnetic model-based calculations. No prior knowledge about the anatomy is required for the application of the algorithm. The estimation of the coil sensitivity profile based on the wavelet transform of the original image data was found to provide a robust method for removing the slowly varying spatial sensitivity pattern of the surface coil image and recovering full FOV images from two-fold acceleration in 8-channel parallel MRI. The results, using bi-orthogonal Daubechies 97 wavelets and other members in this family, are evaluated for T1-weighted and T2-weighted brain imaging.

Algorithms↗

Degenerate mode birdcage volume coil for sensitivity-encoded imaging.

A volume birdcage coil for accelerated image encoding with parallel acquisition methods such as SENSE is demonstrated. The coil is degenerately tuned with both the standard homogeneous mode and the first gradient mode of the birdcage coil resonant at the Larmor frequency. Conventional and antisymmetric coupling structures allow imaging from each of these modes simultaneously. The coil for SENSE-type reconstruction with acceleration factors of up to 2-fold is demonstrated. The spatial distribution of the added noise from the SENSE reconstruction (g-factor map) due to geometrical arrangement of the two-channel system is estimated. The spatially averaged g-factors were found to be 1.21, 1.36, and 1.55 for 1.3, 1.6, and 2-fold accelerations, respectively. The system was demonstrated in vivo using accelerated and nonaccelerated anatomical brain images at 1.5 T. The maximal 2-fold acceleration in this dual-mode degenerate birdcage coil offers the potential to extend SENSE-type image reconstruction methods to applications demanding uniform whole brain coverage.

Brain↗

Multivariate analysis of neuronal interactions in the generalized partial least squares framework: simulations and empirical studies.

Identification of spatiotemporal interactions within/between neuron populations is critical for detection and characterization of large-scale neuronal interactions underlying perception, cognition, and behavior. Univariate analysis has been employed successfully in many neuroimaging studies. However, univariate analysis does not explicitly test for interactions between distributed areas of activity and is not sensitive to distributed responses across the brain. Multivariate analysis can explicitly test for multiple statistical models, including the designed paradigm, and allows for spatial and temporal model detection. Here, we investigate multivariate analysis approaches that take into consideration the 4D (time and space) covariance structure of the data. Principal component analysis (PCA) and independent component analysis (ICA) are two popular multivariate approaches with distinct mathematical constraints. Common difficulties in using these two different decompositions include the following: classification of the revealed components (task-related signal versus noise), overall signal-to-noise sensitivity, and the relatively low computational efficiency (multivariate analysis requires the entire raw data set and more time for model identification analysis). Using both Monte Carlo simulations and empirical data, we derived and tested the generalized partial least squares (gPLS) framework, which can incorporate both PCA and ICA decompositions with computational efficiency. The gPLS method explicitly incorporates the experimental design to simplify the identification of characteristic spatiotemporal patterns. We performed parametric modeling studies of a blocked-design experiment under various conditions, including background noise distribution, sampling rate, and hemodynamic response delay. We used a randomized grouping approach to manipulate the degrees of freedom of PCA and ICA in gPLS to characterize both paradigm coherent and transient brain responses. Simulation data suggest that in the gPLS framework, PCA mostly outperforms ICA as measured by the receiver operating curves (ROCs) in SNR from 0.01 to 100, the hemodynamic response delays from 0 to 3 TR in fMRI, background noise models of Guassian, sub-Gaussian, and super-Gaussian distributions and the number of observations from 5, 10, to 20 in each block of a six-block experiment. Further, due to selective averaging, the gPLS method performs robustly in low signal-to-noise ratio (<1) experiments. We also tested PCA and ICA using PLS in a simulated event-related fMRI data to show their similar detection. Finally, we tested our gPLS approach on empirical fMRI motor data. Using the randomized grouping method, we are able to identify both transient responses and consistent paradigm/model coherent components in the 10-epoch block design motor fMRI experiment. Overall, studies of synthetic and empirical data suggest that PLS analysis, using PCA decomposition, provides a stable and powerful tool for exploration of fMRI/behavior data.

Algorithms↗