PubMed Health⌕ Search

Biomedical subjects

Fabio Augusto

Publications and source records attributed to Fabio Augusto.

10 recordsLinked to original sources

Simultaneous optimization by neuro-genetic approach of a multiresidue method for determination of pesticides in Passiflora alata infuses using headspace solid phase microextraction and gas chromatography.

A simultaneous optimization strategy based on neuro-genetic approach has been applied to a HS-SPME-GC-ECD (Headspace Solid Phase Microextraction coupled to Gas Chromatography with Electron Capture Detection) method for simultaneous determination of the pesticides chlorotalonil, methyl parathion, malathion, alpha-endosulfan and beta-endosulfan in herbal infusions of Passiflora alata (Dryander). Two types of extractive fibers were used: a home-made device coated by sol-gel process with polydimethylsiloxane-poly(vinyl alcohol) (PDMS/PVA) and a commercial PDMS. The effects of extraction parameters such as dilution of the infusion, extraction temperature and time, as well as sample ionic strength were evaluated through the Doehlert design. To find a model that could relate these extraction parameters with the extraction efficiency of all pesticide simultaneously, a Bayesian Regularized Artificial Neural Network (BRANN) approach was employed. Subsequently, Genetic Algorithm (GA) was applied to attain the optimum values from the model developed by the neural network. The use of the proposed approach allowed the determination of a single extraction condition that maximized the peak areas of all pesticides simultaneously, showing a promising and a suitable new procedure to the optimization process of complex analytical problems.

Algorithms↗

Sol-gel molecular imprinted ormosil for solid-phase extraction of methylxanthines.

A organically modified molecularly imprinted silica (MIS), selective for methylxanthines, was prepared using a simple sol-gel procedure. Caffeine was used as template; 3-aminopropyltrimethoxysilane (APTMS) as functional monomer and tetraethyl orthosilicate (TEOS) as reticulating agent. The material was packed on solid-phase extraction (SPE) cartridges and evaluated with aqueous test samples, natural water and human urine; a quantitative method for methylxanthines in water, using SPE cartridges packed with the MIS coupled with HPLC-UV was developed. The MIS was highly specific for methylxanthines, with an imprinting factor of (20.5+/-1.9). The analytical method resulted in detection limits of 85 microgL(-1) for theobromine, 44 microgL(-1) for theophylline and 53 microgL(-1) for caffeine.

Chromatography, High Pressure Liquid↗

Comparison of stir bar sorptive extraction and membrane-assisted solvent extraction as enrichment techniques for the determination of pesticide and benzo[a]pyrene residues in Brazilian sugarcane juice.

The present work compares two modern and environmentally friendly enrichment techniques, stir bar sorptive extraction (SBSE) and membrane-assisted solvent extraction (MASE) for the determination of 18 organic contaminant residues in Brazilian sugarcane juice. Stir bar sorptive extraction and thermal desorption coupled to capillary gas chromatography-mass spectrometry using the selected ion monitoring mode [SBSE-TD-GC-MS(SIM)] and membrane-assisted solvent extraction combined with large volume injection [MASE-LVI-GC-MS(SIM)] methods were assessed taking into account the time of extraction [SBSE (3h) and MASE (30min)], the recoveries [SBSE (0.2-55.3%) and MASE (13.6-103.1%)], the repeatability [SBSE (0.3-19.2%) and MASE (2.6-18.4%)] and the limits of detection [SBSE (0.002-0.71 microgL(-1)) and MASE (0.004-0.56 microgL(-1))] of the selected triazine, organochlorine and organophosphorus pesticides as well as benzo[a]pyrene in sugarcane juice. In general, faster analyses and much better analyte recovery results were achieved with MASE, whereas greater sensitivity and repeatability were obtained with SBSE. SBSE and MASE procedures were applied to the analysis of six sugarcane juice samples from the city São Carlos, in the state of São Paulo, Brazil. A comparison of the results of the pesticide and benzo[a]pyrene residues at microgL(-1) level obtained by the two methods showed good agreement.

Benzo(a)pyrene↗

Highly porous solid-phase microextraction fiber coating based on poly(ethylene glycol)-modified ormosils synthesized by sol-gel technology.

The preparation and characteristics of solid-phase microextraction (SPME) fibers coated with Carbowax 20M ormosil (organically modified silica) are described here. Raw fused silica fibers were coated with Carbowax 20M-modified silica using sol-gel process. Scanning electron micrographs of fibers revealed a highly porous, sponge-like coating with an average thickness of (8 +/- 1) microm. The sol-gel Carbowax fibers were compared to commercial fibers coated with 100 microm polydimethylsiloxane (PDMS) and 65 microm Carbowax-divinylbenzene (DVB). Shorter equilibrium times were possible with the sol-gel Carbowax fiber: for headspace extraction of the test analytes, they ranged from less than 3 min for benzene to 15 min for o-xylene. Extraction efficiencies of the sol-gel Carbowax fiber were superior to those of conventional fibers: for o-xylene, the extracted masses were 230 and 540% of that obtained with 100 microm PDMS and 65 microm Carbowax-DVB fibers, respectively.

Benzene↗

Determination of phthalates in water using fiber introduction mass spectrometry.

Fiber introduction mass spectrometry (FIMS)-a direct coupling of SPME and MS-using selective ion monitoring (SIM) was used to detect and quantify dimethylphthalate (DMP), diethylphthalate (DEP) and dipropylphthalate (DPP) in mineral water. In FIMS, a chromatographic silicone septum is the only barrier between ambient and the high-vacuum mass spectrometer, permitting direct introduction of the SPME fiber into the ionization region of the equipment. After their thermal desorption and ionization and dissociation, the extracted phthalates are detected and quantitated by MS. Three types of SPME fibers were screened for best analyte sorption/desorption behaviors: 100 microm polydimethylsiloxane (PDMS), 65 microm polydimethylsiloxane/divinylbenzene (PDMS/DVB) and 65 microm Carbowax/divinylbenzene (CW/DVB). The PDMS/DVB and CW/DVB fibers were then evaluated for precision, and quantitative figures of merit were assessed for extractions using the PDMS/DVB fiber, which displayed the best overall performance. FIMS with the PDMS/DVB fiber allows simple extraction and MS detection and quantitation of DMP in water with good linearity and precision, and at concentrations as low as 3.6 microg L(-1). The LD and LQ of FIMS are below the maximum phthalate concentration allowed by the USEPA for drinking water (6 microg L(-1)).

Glass↗

Preparation and characterization of polydimethylsiloxane/poly(vinylalcohol) coated solid phase microextraction fibers using sol-gel technology.

The applicability of a composite composed of polydimethylsiloxane (PDMS) and poly(vinyl alcohol) (PDMS/PVA) as coating sorbent for SPME fibers is demonstrated here. Fused silica (FS) fibers were coated with PDMS/PVA composite through a sol-gel process, using methyltrimethoxysilane as reticulating agent. The chemical and physical properties of the sol-gel PDMS/PVA composite were determined by infrared spectroscopy and thermogravimetric analysis. Electron scanning microscopy of the prepared fibers, showed that the coating obtained was highly microporous, having a thickness of approximately 5 microm. The fibers were tested for the headspace extraction of several organic compounds (o-xylene, naphthalene, ethyl caprate, p-chlorotoluene and PCB) prior to gas chromatographic analysis. The extractive capacity of the PDMS/PVA coating was found to be superior to that of pure conventional PDMS fibers.

Chromatography, Gas↗

Application of a novel sol-gel polydimethylsiloxane-poly(vinyl alcohol) solid-phase microextraction fiber for gas chromatographic determination of pesticide residues in herbal infusions.

A simple and environmentally friendly methodology for headspace solid-phase microextraction (HS-SPME) using a new fiber coated with polydimethylsiloxane-poly(vinyl alcohol) (PDMS/PVA) is reported for the trace determination of organochlorine (OCP) and organophosphorus (OPP) pesticides in herbal infusions of Passiflora L. by GC-ECD. The capacity of the PDMS/PVA coating for the pesticides was compared to that of commercial PDMS fibers, with advantageous results. The effects of parameters such as the sample ionic strength, dilution of the infusion, extraction temperature and time were investigated. The optimized conditions for the determination of OCP and OPP in Passiflora L. infusions were extraction time and temperature, respectively, of 38 min and 67.5 degrees C, with 5 min of sample/headspace equilibration time. The analytical curves for the range between 0.04 ng mL(-1) to 6 ng mL(-1) of each compound presented a good quality (correlation coefficients of 0.921 or better). The detection limits for the OCP and OPP in these matrices varied from 0.01 ng mL(-1) (beta-endosulfan) to 1.5 ng mL(-1) (malathion). The sensitivity of studied methodology was adequate, as well as its accuracy (78.7-91.5%) and precision (R.S.D. = 1.2-14.2%).

Chromatography, Gas↗

Studies on the aroma of cupuassu liquor by headspace solid-phase microextraction and gas chromatography.

Headspace solid-phase microextraction (HS-SPME) coupled to gas chromatography with ion trap mass spectrometric detection and with atomic emission detection (GC-AED) was employed to identify possible odor-impact volatile organic compounds in cupuassu (Theobroma grandiflorum Spreng) liquor, as well as to quantify alkylpyrazines present in these samples. SPME fibers coated with 100 microm polydimethylsiloxane (PDMS), 65 microm PDMS-divinylbenzene (DVB) and 75 microm Carboxen (CAR)-PDMS were tested, the later being chosen for the optimized extraction procedure. The principal compounds found in the sample headspace were 3-methylbutanal, dimethylsulfide, dimethyldisulfide, beta-linalool and several alkylpyrazines (notably tetramethylpyrazine). The procedure for quantitation of the alkylpyrazines, using GC-AED for their separation and detection, allowed the detection of microg g(-1) levels of the analytes in the samples, with acceptable precision (R.S.D. less than 10%).

Chromatography, Gas↗

SPME applied to the study of volatile organic compounds emitted by three species of Eucalyptus in situ. Solid-phase micro extraction.

Headspace solid-phase microextraction coupled to gas chromatography/ion trap mass spectrometry-65 microm polydimethylsiloxane/divinylbenzene (PDMS/DVB) was used to identify and monitor the emission patterns of biogenic volatile organic compounds from leaves of Eucalyptus dunnii, Eucalyptus saligna, and Eucalyptus citriodora in situ. Short extractions (1 min) were performed every 30 min for periods of 8-10 h during 24 days taking advantage of the high capacity of this porous polymer coating. Forty-two compounds were detected and 20 identified in the headspace of E. saligna leaves, and 19 of 27 compounds were identified in the headspace of E. dunnii leaves. The emission pattern of (E)-beta-ocimene and rose oxide suggests that they may play a bioactive role in Eucalyptus.

Acyclic Monoterpenes↗

Fiber introduction mass spectrometry: fully direct coupling of solid-phase microextraction with mass spectrometry.

This work describes the first fully direct coupling of solid-phase microextraction (SPME) with mass spectrometry. An inlet system using a septum as the only interface between the ambient and the high-vacuum mass spectrometer was constructed to allow the introduction of the SPME needle directly into the ionization region of a mass spectrometer. The PDMS-coated fiber was then placed and exposed exactly between the two ionization filaments. Uniform heating of the fiber, efficient thermal desorption, and electron ionization of the analytes were achieved. Using this new analytical technique, here termed fiber introduction mass spectrometry (FIMS), we have been able to detect and quantitate several volatile (VOC) and semivolatile (SVOC) organic chemicals (carbon tetrachloride, benzene, toluene, xylenes, gamma-terpinene, diisoamyl ether, chlorobenzene, and many PAHs) and two herbicides (Sylvex and its methyl ether) from aqueous solutions at low-ppb to ppt levels using either SPME headspace or solution extraction. FIMS shows high sensitivity (ng/L), good reproducibility, and accuracy, providing therefore a simple and effective approach to rapid analysis of VOC and SVOC in various matrixes.

Chemistry Techniques, Analytical↗