Measurement of the axial and radial temperature profiles of a chromatographic column. Influence of thermal insulation on column efficiency.

The temperatures of the metal wall along a chromatographic column (longitudinal temperature gradients) and of the liquid phase across the outlet section of the column (radial temperature gradients) were measured at different flow rates with the same chromatographic column (250 mm x 4.6 mm). The column was packed with 5 microm C18-bonded silica particles. The measurements were carried out with surface and immersion thermocouples (all junction Type T, +/-0.1 K) that measure the local temperature. The column was either left in a still-air bath (ambient temperature, T(ext) = 295-296 K) or insulated in a packing foam to avoid air convection around its surface. The temperature profiles were measured at several values of the inlet pressure (approximately = 100, 200, 300 and 350 bar) and with two mobile phases, pure methanol and a 2.5:97.5 (v/v, %) methanol:water solution. The experimental results show that the longitudinal temperature gradients never exceeded 8 K for a pressure drop of 350 bars. In the presence of the insulating foam, the longitudinal temperature gradients become quasi-linear and the column temperature increases by +1 and +3 K with a water-rich (heat conductivity approximately = 0.6 W/m/K) and pure methanol (heat conductivity approximately = 0.2 W/m/K), respectively. The radial temperature gradients are maximum with methanol (+1.5 K at 290 bar inlet pressure) and minimum with water (+0.8 K at 290 bar), as predicted by the solution of the heat transfer balance in a chromatographic column. The profile remains parabolic all along the column. Combining the results of these measurements (determination of the boundary conditions on the wall, at column inlet and at column outlet) with calculations using a realistic model of heat dispersion in a porous medium, the temperature inside the column could be assessed for any radial and axial position.

Chromatography, Liquid↗

Influence of the errors made in the measurement of the extra-column volume on the accuracies of estimates of the column efficiency and the mass transfer kinetics parameters.

The influences of the errors made in the measurement of the extra-column volume of an instrument on the accuracies of the estimates made of the column efficiency and of the parameters of the mass transfer kinetics were investigated from an experimental point of view. A standard HP1090 apparatus (extra-column volume, approximately 50 micro L) was used to measure the efficiency of a Sunfire-C(18) RPLC column (column hold-up volume, approximately 1.50 mL). The first and second moments of the peaks of phenol (a retained compound) and of thiourea (a practically non-retained compound) were measured at six different temperatures between 22 and 78 degrees C, for flow rates between 0.10 and 4.70 mL/min (i.e., for linear velocities between 0.025 and 1.179 cm/s). Each series of measurements was successively made with the instrument being fitted with and without the column. The experimental HETP data must be corrected for the solute dispersion in the connected tubes in order properly to assess the true column efficiency. Even with a modern, high performance instrument, the dispersion of a non-retained compound is essentially due to the band broadening phenomena that take place in the extra-column volumes, the sum of all these extra-column band broadening contributions accounting for more than 80% of the total band broadening measured. The contribution of the sampling device is particularly deleterious since, for a 2 mu L injection, the maximum solute concentration in the peak that enters into the column is nearly ten-fold lower than that of the sample. Nevertheless, the impact of the extra-column volumes on the estimates of the kinetic parameters (e.g., molecular diffusion coefficient D(m) and effective particle diffusivity D(e)) remains negligible. Obviously, the relative error made on the column efficiency of a retained compound depends much on its retention factor. It decreases from 8 to 1% when the retention factor increases from 5 to 17.

Chromatography, Liquid↗

Experimental evidence of the influence of the surface chemistry of the packing material on the column pressure drop in reverse-phase liquid chromatography.

The permeabilities of six columns packed with different packing materials (neat silica, C(1) endcapped silica at 3.92 micro mol/m(2), C(18) bonded and endcapped silica with 0.42, 1.01, 2.03, and 3.15 micro mol/m(2) of C(18) bonded chains) were measured. All these materials derive from the same batch of spherical particles, 5 micro m in diameter. The columns have the same tube inner diameter (phi=0.460+/-0.003 cm) and length (L=15.000+/-0.003 cm). The experimental conditions were the same, flow-rate (F(v)=1.000+/-0.003 mL/min) and temperature (295 K). Nevertheless, it was found that the column permeability decreases significantly, by about 25%, from the neat silica column to the one packed with the highest density of C(18)-bonded silica (3.15 micro mol/m(2)). The results measured on two duplicate columns were very reproducible. Accurate (+/-0.5 %) measurements of the hold-volumes with concentrated and dilute solutions of NO(3)(-) showed that the columns had all nearly the same external porosity. The result cannot be explained by the error made on the volume of the column tube either as it was measured accurately for all the columns. The residual explanation is that the interstitial velocity distribution between the packed particles depends on the chemical nature of the external surface of these particles.

Chromatography, Liquid↗

Effects of the thermal heterogeneity of the column on chromatographic results.

The influence of the thermal heterogeneity of HPLC columns on retention data was investigated. The retention factor of the retained compound phenol was measured at 24 increasing values of the flow rate, from 0.025 to 4.9 mL/min, on six different packing materials prepared with the same batch of silica particles (5 microm diameter, 90 A pore size). One column was packed with the neat silica particles, another with the silica endcapped with trimethylchlorosilane (TMS)(C(1), 3.92 micromol/m(2)), and the other four with silica first derivatized with octadecyl-dimethyl-chlorosilane (C(18), 0.42, 1.01, 2.03, and 3.15 micromol/m(2)), and second endcapped with TMS. Four different sources of heat contributing to raise the column temperature were considered: (1) the heat supplied by the hot high-pressure pump chamber to the solvent; (2) the adiabatic (dS=0) compression of the solvent in the high-pressure pump; (3) the isenthalpic (dH=0) decompression of the solvent during its migration along the porous chromatographic bed; and (4) the heat released by the friction of the solvent percolating through the column bed. The main contributions appear to be the heat supplied to the solvent by the HP pump and the friction heat. The average column temperature (ACT) was indirectly derived from the measurements of the first moment, mu(1), of phenol peak, of the column pressure drop, DeltaP, and of the retention factors of the phenol peak apices as a function of the flow rate applied. If the column is placed in a still-air bath at 298 K (and its temperature is not externally controlled), a longitudinal temperature gradient is established along the column and the average column temperature is about 6 K higher when this column is operated at 4.9 mL/min than when the flow rate is only 0.025 mL/min. If the column is placed in a heated air bath (temperature controlled at 316 or 338 K), the ACT changes by less than 3 K over the whole flow rate range applied.

Chromatography, High Pressure Liquid↗

Heterogeneity of the adsorption mechanism of low molecular weight compounds in reversed-phase liquid chromatography.

The retention mechanism in RPLC mode was investigated based on the acquisition of adsorption isotherm data by frontal analysis measurements and their modeling. This work is a review of the results of four years of adsorption data measurements. The data were acquired on a wide variety of brands of C18-silica columns (from Akzo Nobel, Bishoff, Hypersil, Merck, Phenomenex, Supelco, Vydac, and Waters) with several low molecular weight compounds such as phenol (94 g/mol), caffeine (194 g/mol), tryptophan (204 g/mol), sodium 2-naphthalenesulfonate (235 g/mol), and propranololium chloride (295 g/mol). The mobile phase was a mixture of methanol and water at variable composition. The adsorption isotherms were all convex upward (langmuirian), and the degree of heterogeneity of the adsorption system was determined from the calculation of the adsorption energy distribution using the expectation-maximization method. The adsorption isotherm parameters (number of types of adsorption sites, surface concentration of each type of site, and difference between the adsorption energies E(i) - E(j) on sites i and j), obtained from the mathematical fit of the adsorption data to the appropriate multi-Langmuir adsorption isotherm model, were analyzed and compared. The results allow the drawing of general conclusions regarding the relationships between the size of the analyte and the adsorption properties (saturation capacities, adsorption energies) characterizing the retention mechanism in RPLC mode for neutral, anionic, and cationic compounds.

Journal Article↗

General HETP equation for the study of mass-transfer mechanisms in RPLC.

Classical HETP equations including the Van Deemter and the Knox equations, are semiempirical, approximate equations that provide apparent mass-transfer coefficients with little sound physical justifications. The conventional A and B coefficients are revisited, the former through the use of the fundamental theory of eddy diffusion due to Giddings, the latter by taking into account the intraparticle diffusion (pore and surface diffusion). Our work confirms that eddy diffusion originated from three different sources in RPLC: trans-channel, short-range interchannel, and long-range interchannel velocity biases. Accordingly, the eddy diffusion term is given by the ratio of two third-degree polynomials. Finally, the C term is the sum of two terms corresponding to the resistance to mass transfer due to diffusion through the external stationary film of liquid phase surrounding the silica particles and to the classical resistances to mass transfer due to diffusion through the silica particles. It is easily related to the physical characteristics of the phenomena involved. Experimental HETP data were derived from moment analysis for phenol on a C(18)-Sunfire column, with a mixture of acetonitrile and water as the mobile phase (15/85, v/v). The linear interstitial velocity ranged between 0.027 cm/s and 4.7 mL/min, and six temperature (21, 36, 45, 55, 67, and 77 degrees C) were applied successively. The HETP equation obtained was tested to study the mass-transfer mechanism. An excellent agreement was found between the experimental and theoretical HETP. The model allows the precise calculation of the activation energy for surface diffusion (E(S) = 31.3 kJ/mol) and the coefficient beta that relates the restriction energy for molecular diffusion on the C(18)-bonded surface to the isosteric heat of adsorption Q(st) (beta = 0.80).

Chemical Phenomena↗

Effect of the density of the C(18) surface coverage on the adsorption mechanism of a cationic compound and on the silanol activity of the stationary phase in reversed phase liquid chromatography.

RPLC columns with different surface coverages (a C(1) endcapped column with a bonding density of 3.92 micromol/m(2) and four C(18)-bonded, endcapped columns, with octadecyl chain densities of 0.42, 1.01, 2.03, and 3.15 micromol/m(2)) were used to investigate the effects of the density of the surface coverage of RPLC columns on the adsorption mechanism of a cationic compound, amitriptyline chloride, and on the silanol activity of these columns. The mobile phases used were acetonitrile-water (30/70, v/v) solutions, buffered at either pH 2.7 or pH 6.9. At pH 2.7, the residual silanol groups are not ionized. At pH 6.9, some of these groups are ionized and these surface anions can strongly interact with the cationic compound. The adsorption isotherms were measured by frontal analysis (FA) at pH 2.7 and by frontal analysis by characteristic points (FACP) at pH 6.9, because the very high retention observed at neutral pH made FA measurements excessively long and poorly accurate. The adsorption energy distributions (AEDs) were calculated when possible, according to the expectation-maximization (EM) algorithm. A bimodal and a trimodal energy distribution were found for all the columns at pH 2.7 and 6.9, respectively. The third site measured at pH 6.9 was attributed to the strong ion-exchange interactions between the ionized silanol groups and the amitriptylinium cation. The contribution of the ionized silanol groups to the overall retention is maximum for the phases with intermediary bonding densities (1.01 and 2.03 micromol/m(2)). The peak tailing is most pronounced for the lowest (C(1) column) and the highest (3.15 micromol/m(2)) surface coverages.

Adsorption↗

Influence of the degree of coverage of C18-bonded stationary phases on the mass transfer mechanism and its kinetics.

The influence of the degree of coverage of a silica surface with bonded C18 alkyl chains on the mass transfer mechanism in RPLC was investigated. Five packing materials were used, prepared with the same batch of silica particles (5 microm diameter, 90 A average pore size): one column was packed with the silica derivatized by trimethylchlorosilane (TMS) (C1, 3.92 micromol/m2), and the other four with the silica first derivatized with octadecyl-dimethyl-chlorosilane (C18, 0.42, 1.01, 2.03, and 3.15 micromol/m2), and then endcapped with TMS. A solution of methanol and water (25/75, v/v) was used as the mobile phase. The experimental HETP curves were acquired for each column by measuring the first moment and the second central moment of phenol and correcting them for the influence of the temperature increase due to the heat generated by the friction of the stream against the bed. The different kinetic parameters of the mass transfer in these packed chromatographic columns were identified (longitudinal diffusion, eddy diffusion, film mass transfer, and transparticle mass transfer) and quantified by fitting the experimental data to a new general HETP equation recently derived [F. Gritti, G. Guiochon, Anal. Chem., in press (AC-060203R).]. The agreement was excellent and allowed the comparison of the kinetic parameters among the six columns used. The highest column efficiency measured at conventional or fast flow rates (>0.5 ml/min) is obtained for the most retentive column, which has a surface coverage of 2.03 micromol/m2. The smallest HETP measured is as low as 10 microm, only twice the average particle diameter dp, due to the large contribution of surface diffusion (90%) to the particle effective diffusivity. However, no significant difference was observed between the efficiencies of the columns packed with C1 and C18 derivatized silica.

Chromatography, High Pressure Liquid↗

Adsorption mechanisms and effect of temperature in reversed-phase liquid chromatography. meaning of the classical Van't Hoff plot in chromatography.

The effect of temperature on the adsorption and retention behaviors of a low molecular weight compound (phenol) on a C18-bonded silica column (C18-Sunfire, Waters) from aqueous solutions of methanol (20%) or acetonitrile (15%) was investigated. The results of the measurements were interpreted successively on the basis of the linear (i.e., overall retention factors) and the nonlinear (i.e., adsorption isotherms, surface heterogeneity, saturation capacities, and equilibrium constants) chromatographic methods. The confrontation of these two approaches confirmed the impossibility of a sound physical interpretation of the conventional Van't Hoff plot. The classical linear chromatography theory assumes that retention is determined by the equilibrium thermodynamics of analytes between a homogeneous stationary phase and a homogeneous mobile phase (although there may be two or several types of interactions). From values of the experimental retention factors in a temperature interval and estimates of the activity coefficients at infinite dilution in the same temperature interval provided by the UNIFAC group contribution method, evidence is provided that such a retention model cannot hold. The classical Van't Hoff plot appears meaningless and its linear behavior a mere accident. Results from nonlinear chromatography confirm these conclusions and provide explanations. The retention factors seem to fulfill the Van't Hoff equation, not the Henry constants corresponding to the different types of adsorption sites. The saturation capacities and the adsorption energies are clearly temperature dependent. The temperature dependence of these characteristics of the different assorption sites are different in aqueous methanol and acetonitrile solutions.

Adsorption↗

Adsorption mechanism in reversed-phase liquid chromatography. Effect of the surface coverage of a monomeric C18-silica stationary phase.

The effect of the bonding density of the octadecyl chains onto the same silica on the adsorption and retention properties of low molecular weight compounds (phenol, caffeine, and sodium 2-naphthalene sulfonate) was investigated. The same mobile phase (methanol:water, 20:80, v/v) and temperature (T = 298 K) were applied and two duplicate columns (A and B) from each batch of packing material (neat silica, simply endcapped or C1 phase, 0.42, 1.01, 2.03, and 3.15 micromol/m2 of C18 alkyl chains) were tested. Adsorption data of the three compounds were acquired by frontal analysis (FA) and the adsorption energy distributions (AEDs) were calculated using the expectation-maximization method. Results confirmed earlier findings in linear chromatography of a retention maximum at an intermediate bonding density. From a general point of view, the saturation capacity of the adsorbent tends to decrease with increasing bonding density, due to the vanishing space intercalated between the C18 bonded chains and to the decrease of the specific surface area of the stationary phase. The equilibrium constants are maximum for an intermediary bonding density (approximately 2 micromol/m2). An enthalpy-entropy compensation was found for the thermodynamic parameters of the isotherm data. Weak equilibrium constants (small deltaH) and high saturation capacities (large deltaS) were observed at low bonding densities, higher equilibrium constants and lower saturation capacities at high bonding densities, the combinations leading to similar apparent retention in RPLC. The use of a low surface coverage column is recommended for preparative purposes.

Adsorption↗

Extension of Tóth Psi function from gas-solid to liquid-solid equilibria and application to reversed-phase liquid chromatography systems.

The extension of the Psi function developed by Tóth from equilibria taking place at gas-solid interfaces to those taking place at liquid-solid interfaces was investigated. The results were applied to conventional liquid-solid systems used in reversed-phase liquid chromatography (RPLC). The adsorbents in these systems are made of porous silica having a hydrophobic solid surface obtained by chemically bonding C(18) alkyl chains to a porous silica gel then endcapping the surface with trimethylsilyl groups. The liquid is an aqueous solution of an organic solvent, most often methanol or acetonitrile. The probe compound used here is phenol. Adsorption data of phenol were measured using the dynamic frontal analysis (FA) method. The excess adsorption of the organic solvent was measured using the minor disturbance (MD) method. Activity coefficients in the bulk were estimated through the UNIFAC group contributions. The results show that the Psi function predicts 90% of the total free energy of immersion, DeltaF, of the solid when the concentration of phenol is moderate (typically less than 10 g/L). At higher concentrations, the nonideal behavior of the bulk liquid phase becomes significant and it may contribute up to about 30% of DeltaF. The high concentration of adsorbed molecules of phenol at the interface decreases the interfacial tension, sigma, by about 18 mN/m, independently of the structure of the adsorbed phase and of the nature of the organic solvent.

Journal Article↗

A chromatographic estimate of the degree of surface heterogeneity of RPLC packing materials. III. Endcapped amido-embedded reversed phase.

The difference in adsorption behavior between a conventional monomeric endcapped C18 stationary phase (3.43 micromol/m2) and an endcapped polymeric RP-Amide phase (3.31 micromol/m2) was investigated. The adsorption isotherms of four compounds (phenol, caffeine, sodium 2-naphthalene sulfonate, and propranololium chloride) were measured by frontal analysis (FA) and the degree of heterogeneity of each phase for each solute was characterized by their adsorption energy distributions (AED), derived using the Expectation-Maximization method. The results show that only certain analytes (phenol and 2-naphthalene sulfonate) are sensitive to the presence of the polar embedded amide groups within the RP phase. Their binding constants on the amide-bonded phase are significantly higher than on conventional RPLC phases. Furthermore, an additional type of adsorption sites was observed for these two compounds. However, these sites having a low density, their presence does not affect much the retention factors of the two analytes. On the other hand, the adsorption behavior of the other two analytes (caffeine and propranololium chloride) is almost unaffected by the presence of the amide group in the bonded layer. Strong selective interactions may explain these observations. For example, hydrogen-bond interactions between an analyte (e.g., phenol or naphthalene sulfonate) and the carbonyl group (acceptor) or the nitrogen (donor) of the amido-embedded group may take place. No such interactions may take place with either caffeine or the cation propranololium chloride. This study confirms the hypothesis that analytes have ready access to locations deep inside the bonded layer, where the amide groups are present.

Adsorption↗

A chromatographic estimate of the degree of heterogeneity of RPLC packing materials. 1. Non-endcapped polymeric C30-bonded stationary phase.

A new chromatographic method estimating the degree of heterogeneity of RPLC packing materials is based on the results of systematic measurements of the adsorption data in a wide concentration range for selected probe compounds. These data are acquired by frontal analysis (FA), modeled, and used for the calculation of the adsorption energy distribution (AED). Four compounds were used, two neutral compounds of different molecular sizes (caffeine and phenol) and two ionizable compounds of opposite charges, 2-naphthalene sulfonate, an anion, and propranololium, a cation. This work was done on a C30-bonded silica stationary phase (Prontosil-C30), using the same aqueous mobile phase (30% methanol, v/v) for all compounds, except that sodium chloride (25 mM) was added to elute the ionizable compounds. All four adsorption isotherms have Langmuirian behavior. The AEDs are tri-modal for phenol, quadri-modal for caffeine. The total saturation capacity of the stationary phase is four-fold lower for caffeine than for phenol, due in part to its larger molecular size. The equilibrium constants on the low-energy sites of types 1 and 2 are eight-fold larger. These two types of sites characterize the heterogeneity of the bonded layer itself. The density of the high-energy sites of types 3 and 4 is higher for caffeine, suggesting that caffeine molecules can be accommodated in some hydrophobic cages into which smaller molecules like phenol cannot. These high-energy types of sites characterize the heterogeneity of the whole stationary phase (silica support included). The ionizable compounds have larger molecules than the neutral ones and, accordingly, a lower relative density of sites of type 2 to sites of type 1. A tri-modal and a quadri-modal energy distributions were observed for the 2-naphthalene sulfonate anion and the propranololium cation, respectively. The fourth types of sites measured and its unusually high equilibrium constant are most probably due to ion-exchange interactions between the non-endcapped ionized silanols and the propranololium ion. No such strong interactions are observed with the anionic compound.

Adsorption↗

A chromatographic estimate of the degree of surface heterogeneity of reversed-phase liquid chromatography packing materials. II-Endcapped monomeric C18-bonded stationary phase.

In a previous report, the heterogeneity of a non-endcapped C30-bonded stationary phase was investigated, based on the results of the measurements of the adsorption isotherms of two neutral compounds (phenol and caffeine) and two ionizable compounds (sodium naphthalene sulfonate and propranololium chloride) by frontal analysis (FA). The same method is applied here for the characterization of the surface heterogeneity of two new brands of endcapped C18-bonded stationary phases (Gemini and Sunfire). The adsorption isotherms of the same four chemicals were measured by FA and the results confirmed by the independent calculation of the adsorption energy distribution (AED), using the expectation-maximization (EM) method. The effect of the length of the bonded alkyl chain was investigated. Shorter alkyl-bonded-chains (C18 versus C30) and the end-capping of the silica surface contribute to decrease the surface heterogeneity under the same experimental conditions (30% methanol, 25 mM NaCl). The AEDs of phenol and caffeine are bimodal with the C18-bonded columns while they are trimodal and quadrimodal, respectively, with a non-endcapped C30-bonded column. The "supersites" (adsorption energy > 20 kJ/mol) found on the C30-Prontosil column and attributed to a cation exchange mechanism completely disappear on the C18-Gemini and C18-Sunfire, probably because the end-capping of the silica surface eliminates most if not all the ionic interactions.

Adsorption↗

Critical contribution of nonlinear chromatography to the understanding of retention mechanism in reversed-phase liquid chromatography.

The retention of most compounds in RPLC proceeds through a combination of several independent mechanisms. We review a series of recent studies made on the behavior of several commercial C18-bonded stationary phases and of the complex, mixed retention mechanisms that were observed in RPLC. These studies are essentially based on the acquisition of adsorption isotherm data, on the modeling, and on the interpretation of these data. Because linear chromatography deals only with the initial slope of the global, overall, or apparent isotherm, it is unable fully to describe the complete adsorption mechanism. It cannot even afford clues as to the existence of several overlaid retention mechanisms. More specifically, it cannot account for the consequences of the surface heterogeneity of the packing material. The acquisition of equilibrium data in a wide concentration range is required for this purpose. Frontal analysis (FA) of selected probes gives data that can be modeled into equilibrium isotherms of these probes and that can also be used to calculate their adsorption or affinity energy distribution (AED). The combination of these data, the detailed study of the best constants of the isotherm model, the determination of the influence of experimental parameters (e.g., buffer pH and pI, temperature) on the isotherm constants provide important clues regarding the heterogeneity of the adsorbent surface and the main properties of the adsorption mechanisms. The comparison of similar data obtained for the adsorption of neutral and ionizable compounds, treated with the same approach, and the investigation of the influence on the thermodynamics of phase equilibrium of the experimental conditions (temperature, average pressure, mobile phase composition, nature of the organic modifier, and, for ionizable compounds, of the ionic strength, the nature, the concentration of the buffer, and its pH) brings further information. This review provides original conclusions regarding retention mechanisms in RPLC.

Adsorption↗

Adsorption of the enantiomers of 3-chloro-1-phenyl-propanol on silica-bonded chiral quinidine carbamate.

The interactions of 3-chloro-1-phenyl-propanol with a quinidine carbamate-bonded chiral stationary phase under NPLC conditions were studied by measuring the adsorption isotherm data of its enantiomers by frontal analysis, modeling these data with a suitable isotherm model, and comparing the experimental overloaded elution band profiles with those calculated with this isotherm and the equilibrium dispersive model of liquid chromatography. The affinity energy distribution was calculated from the adsorption isotherm data. The results show that the surface of the adsorbent is heterogeneous and exhibits a bimodal adsorption energy distribution. This fact is interpreted in terms of the presence of two different types of adsorption sites on the stationary phase, nonselective and enantioselective sites. Albeit the bi-Langmuir isotherm model successfully accounts for the single-component data corresponding to both enantiomers, the competitive bi-Langmuir isotherm model does not allow an accurate prediction of the overloaded band profiles of the racemic mixture. Thermodynamic data are drawn for explanation. Some aspects of the retention mechanism are discussed in the light of the data obtained.

Adsorption↗

Separation mechanism of nortriptyline and amytriptyline in RPLC.

The single and the competitive equilibrium isotherms of nortriptyline and amytriptyline were acquired by frontal analysis (FA) on the C18- bonded discovery column, using a 28/72 (v/v) mixture of acetonitrile and water buffered with phosphate (20 mM, pH 2.70). The adsorption energy distributions (AED) of each compound were calculated from the raw adsorption data. Both the fitting of the adsorption data using multi-linear regression analysis and the AEDs are consistent with a trimodal isotherm model. The single-component isotherm data fit well to the tri-Langmuir isotherm model. The extension to a competitive two-component tri-Langmuir isotherm model based on the best parameters of the single-component isotherms does not account well for the breakthrough curves nor for the overloaded band profiles measured for mixtures of nortriptyline and amytriptyline. However, it was possible to derive adjusted parameters of a competitive tri-Langmuir model based on the fitting of the adsorption data obtained for these mixtures. A very good agreement was then found between the calculated and the experimental overloaded band profiles of all the mixtures injected.

Adsorption↗

Effect of the endcapping of reversed-phase high-performance liquid chromatography adsorbents on the adsorption isotherm.

The retention mechanisms of n-propylbenzoate, 4-t ert-butylphenol, and caffeine on the endcapped Symmetry-C(18) and the non-endcapped Resolve-C(18) are compared. The adsorption isotherms were measured by frontal analysis (FA), using as the mobile phase mixtures of methanol or acetonitrile and water of various compositions. The isotherm data were modeled and the adsorption energy distributions calculated. The surface heterogeneity increases faster with decreasing methanol concentration on the non-endcapped than on the endcapped adsorbent. For instance, for methanol concentrations exceeding 30% (v/v), the adsorption of caffeine is accounted for by assuming three and two different types of adsorption sites on Resolve-C(18) and Symmetry-C(18), respectively. This is explained by the effect of the mobile phase composition on the structure of the C(18)-bonded layer. The bare surface of bonded silica appears more accessible to solute molecules at high water contents in the mobile phase. On the other hand, replacing methanol by a stronger organic modifier like acetonitrile dampens the differences between non-endcapped and endcapped stationary phase and decreases the degree of surface heterogeneity of the adsorbent. For instance, at acetonitrile concentrations exceeding 20%, the surface appears nearly homogeneous for the adsorption of caffeine.

Acetonitriles↗