Effectiveness of mask and helmet interfaces to deliver noninvasive ventilation in a human model of resistive breathing.

The helmet, a transparent latex-free polyvinyl chloride cylinder linked by a metallic ring to a soft collar that seals the helmet around the neck, has been recently proposed as an effective alternative to conventional face mask to deliver pressure support ventilation (PSV) during noninvasive ventilation in patients with acute respiratory failure. We tested the hypothesis that mechanical characteristics of the helmet (large internal volume and high compliance) might impair patient-ventilator interactions compared with standard face mask. Breathing pattern, CO(2) clearance, indexes of inspiratory muscle effort and patient-ventilator asynchrony, and dyspnea were measured at different levels of PSV delivered by face mask and helmet in six healthy volunteers before (load-off) and after (load-on) application of a linear resistor. During load-off, no differences in breathing pattern and inspiratory muscle effort were found. During load-on, the use of helmet to deliver pressure support increased inspiratory muscle effort and patient-ventilator asynchrony, worsened CO(2) clearance, and increased dyspnea compared with standard face mask. Autocycled breaths accounted for 12 and 25% of the total minute ventilation and for 10 and 23% of the total inspiratory muscle effort during mask and helmet PSV, respectively. We conclude that PSV delivered by helmet interface is less effective in unloading inspiratory muscles compared with PSV delivered by standard face mask. Other ventilatory assist modes should be tested to exploit to the most the potential benefits offered by the helmet.

Adult↗

Patient-ventilator interaction during the triggering phase.

Partial patient-controlled mechanical support mode ventilators provide positive pressure assistance whenever a patient's inspiratory effort decreases pressure or flow in the ventilator circuit below the sensitivity set by clinicians; these modes minimize disuse atrophy of the respiratory muscles, can facilitate the weaning process, and usually require lower ventilator pressures. The capability of restoring gas exchange, unloading respiratory muscles, and relieving the patient's dyspnea with partial patient-controlled mechanical support modes depends on matching between the ventilator setting and the patient's ventilatory demand (ie, patient-ventilator interactions).

Airway Resistance↗

Physiological effects of translaryngeal open ventilation in patients with restrictive respiratory disorders.

OBJECTIVE: To compare the efficacy of pressure-controlled ventilation (PCV) delivered through a conventional endotracheal tube with the same ventilatory mode using a small-size tube with the cuff left deflated (translaryngeal open ventilation: TLOV). SETTING: A medical-surgical intensive care unit (ICU). DESIGN: Prospective physiological study. PATIENTS: Thirteen consecutive patients with restrictive neuromuscular and thoracic respiratory disorders ventilated in pressure-controlled mode. INTERVENTIONS: The standard tube was removed and a microlaryngeal tube (i.d. 4 mm, o.d. 6 mm, length 380 mm) was inserted with the cuff left deflated. PCV was increased to match the tracheal pressure measured during conventional ventilation. Arterial blood gases were measured before, 1 h and 20 h after initiating TLOV. A patient comfort score was measured by a visual analogue scale during conventional ventilation and 20 h after initiating TLOV (0= very bad, 1= bad, 2= quite bad, 3= sufficient, 4= good, and 5= very good). RESULTS: Inspiratory pressure was significantly increased from 16+/-5 cmH(2)O to 68+/-13 cmH(2)O after 1 h and to 65+/-12 cmH(2)O after 20 h to match the tracheal pressure measured during conventional ventilation (CV) (p<0.005). No statistically significant differences were found in arterial blood gases and patient's respiratory rate before and after 1 and 20 h of TLOV. The comfort score was 1.3+/-0.4 and 3.6+/-0.4 during CV and TLOV, respectively, on a scale from 0 to 5 (p<0.002). CONCLUSION: This study indicates that, in selected patients, TLOV was as efficient as conventional PCV.

Adolescent↗