PubMed Health⌕ Search

Biomedical subjects

Fan-Gang Zeng

Publications and source records attributed to Fan-Gang Zeng.

At least 19 recordsLinked to original sources

AAV gene therapy for autosomal recessive deafness 9: a single-arm trial.

Gene therapy for congenital deafness has shown promising results in children but lacks data in older populations. We conducted a single-arm trial of adeno-associated virus (AAV)-OTOF gene therapy using the Anc80L65 capsid in ten participants with autosomal recessive deafness 9 aged 1.5 to 23.9 years at five sites in China. The primary endpoints were safety and tolerability within 5 years, and secondary endpoints assessed auditory function. Initial findings from the ten patients with 6-12 months of follow-up, including one patient who received two injections, revealed that the therapy was well tolerated, with 162 grade I/II adverse events. Decreased neutrophil percentage was the most common event (16 of 162). All ten participants had at least 6 months of follow-up and improved their pure-tone-average hearing level from baseline 106 ± 9 (mean ± s.d.) to 52 ± 30 decibels (dB). Other secondary endpoints showed similar improvements, including the average click auditory brainstem response (ABR) threshold, the tone-burst ABR threshold and the auditory steady-state response (101 ± 1 to 48 ± 26 dB, 91 ± 4 to 57 ± 19 dB and 80 ± 14 to 64 ± 21 dB, respectively). Post hoc analyses were conducted to evaluate the timecourse and factors contributing to the hearing improvement. Therapeutic effect was rapid, taking 1 month to achieve most of the overall hearing improvement. On an individual level, click and tone-burst ABR thresholds, but not the auditory steady-state response, reliably predicted the behavioral pure-tone-average thresholds after 4 months (R2 = 0.68, 0.73 and 0.17, respectively). An age-dependent therapeutic effect was observed, with optimal outcomes in 5- to 8-year-olds. These preliminary results show that AAV-OTOF was safe and well tolerated in patients ranging from toddlerhood to adulthood. The trial remains ongoing and requires extended follow-up to confirm the long-term safety and efficacy. ClinicalTrials.gov registration: NCT05901480 .

Humans↗

Opposite patterns of hemisphere dominance for early auditory processing of lexical tones and consonants.

In tonal languages such as Mandarin Chinese, a lexical tone carries semantic information and is preferentially processed in the left brain hemisphere of native speakers as revealed by the functional MRI or positron emission tomography studies, which likely measure the temporally aggregated neural events including those at an attentive stage of auditory processing. Here, we demonstrate that early auditory processing of a lexical tone at a preattentive stage is actually lateralized to the right hemisphere. We frequently presented to native Mandarin Chinese speakers a meaningful auditory word with a consonant-vowel structure and infrequently varied either its lexical tone or initial consonant using an odd-ball paradigm to create a contrast resulting in a change in word meaning. The lexical tone contrast evoked a stronger preattentive response, as revealed by whole-head electric recordings of the mismatch negativity, in the right hemisphere than in the left hemisphere, whereas the consonant contrast produced an opposite pattern. Given the distinct acoustic features between a lexical tone and a consonant, this opposite lateralization pattern suggests the dependence of hemisphere dominance mainly on acoustic cues before speech input is mapped into a semantic representation in the processing stream.

Acoustic Stimulation↗

Loudness adaptation in acoustic and electric hearing.

The present study is aimed to evaluate and compare loudness adaptation between normal hearing and cochlear-implant subjects. Loudness adaptation for 367-s pure tones was measured in five normal-hearing subjects at three frequencies (125, 1,000, and 8,000 Hz) and three levels (30, 60, and 90 dB SPL). In addition, loudness adaptation for 367-s pulse trains was measured in five Clarion cochlear-implant subjects at three stimulation rates (100, 991, and 4,296 Hz), three levels (10, 50, and 90% of the electric dynamic range), three stimulation positions (apical, middle and basal), and two stimulation modes (monopolar and bipolar). The method of successive magnitude estimation was used to quantify loudness adaptation. Similar to the previous results, we found that loudness adaptation in normal-hearing subjects increases with decreasing level and increasing frequency. However, we also found a small but significant loudness enhancement at 90 dB SPL in acoustic hearing. Despite large individual variability, we found that loudness adaptation in cochlear-implant subjects increases with decreasing levels, but is not significantly affected by the rate, place and mode of stimulation. A phenomenological model was proposed to predict loudness adaptation as a function of stimulus frequency and level in acoustic hearing. The present results were not fully compatible with either the restricted excitation hypothesis or the neural adaptation hypothesis. Loudness adaptation may have a central component that is dependent on the peripheral excitation pattern.

Acclimatization↗

Micromechanical resonator array for an implantable bionic ear.

In this paper we report on a multi-resonant transducer that may be used to replace a traditional speech processor in cochlear implant applications. The transducer, made from an array of micro-machined polymer resonators, is capable of passively splitting sound into its frequency sub-bands without the need for analog-to-digital conversion and subsequent digital processing. Since all bands are mechanically filtered in parallel, there is low latency in the output signals. The simplicity of the device, high channel capability, low power requirements, and small form factor (less than 1 cm) make it a good candidate for a completely implantable bionic ear device.

Algorithms↗

An electronic prosthesis mimicking the dynamic vestibular function.

This paper presents a functional architecture, system level design, and electronic evaluation of a unilateral vestibular prosthesis. The sensing unit of the prosthesis is a custom-designed one-axis micro-electromechanical system (MEMS) gyroscope. Similar to the natural semicircular canal, the MEMS gyroscope senses angular motion of the head and generates voltages proportional to the corresponding angular acceleration. The voltage is then converted into electric current pulses according to the physiological data relating angular acceleration to the spike count in the vestibular nerve. The current pulses can be delivered to stimulate the corresponding vestibular nerve branch. Electronic properties of the vestibular prosthesis prototype have been systematically evaluated and found to meet the design specifications. A unique feature of the present vestibular implant prototype is the scalability: the sensing unit, pulse generator, and the current source can be potentially implemented on a single chip using integrated MEMS technology.

Animals↗

Speech perception in individuals with auditory neuropathy.

PURPOSE: Speech perception in participants with auditory neuropathy (AN) was systematically studied to answer the following 2 questions: Does noise present a particular problem for people with AN? Can clear speech and cochlear implants alleviate this problem? METHOD: The researchers evaluated the advantage in intelligibility of clear speech over conversational speech in 13 participants with AN. Of these participants, 7 had received a cochlear implant. Eight sentence-recognition experiments were conducted to examine the clear speech advantage in 2 listening conditions (quiet and noise) using 4 stimulation modes (monaural acoustic, diotic acoustic, monaural electric, and binaurally combined acoustic and electric stimulation). RESULTS: Participants with AN performed more poorly in speech recognition in noise than did the normal-hearing, cochlear-impaired, and cochlear implant controls. A significant clear speech advantage was observed, ranging from 9 to 23 percentage points in intelligibility for all listening conditions and stimulation modes. Electric stimulation via a cochlear implant produced significantly higher intelligibility than acoustic stimulation in both quiet and in noise. Binaural hearing with either diotic acoustic stimulation or combined acoustic and electric stimulation produced significantly higher intelligibility than monaural stimulation in quiet but not in noise. CONCLUSIONS: Participants with AN most likely derive the clear speech advantage from enhanced temporal properties in clear speech and improved neural synchrony with electric stimulation. Although the present result supports cochlear implantation as one treatment choice for people with AN, it suggests that the use of innovative hearing aids may be another viable option to improve speech perception in noise.

Acoustic Stimulation↗

Spectral and temporal cues in cochlear implant speech perception.

OBJECTIVE: Taking advantage of the flexibility in the number of stimulating electrodes and the stimulation rate in a modern cochlear implant, the present study evaluated relative contributions of spectral and temporal cues to cochlear implant speech perception. DESIGN: Four experiments were conducted by using a Research Interface Box in five MED-EL COMBI 40+ cochlear implant users. Experiment 1 varied the number of electrodes from four to twelve or the maximal number of available active electrodes while keeping a constant stimulation rate at 1000 Hz per electrode. Experiment 2 varied the stimulation rate from 1000 to 4000 Hz per electrode on four pairs of fixed electrodes. Experiment 3 covaried the number of stimulating electrodes and the stimulation rate to study the trade-off between spectral and temporal cues. Experiment 4 studied the effects of envelope extraction on speech perception and listening preference, including half-wave rectification, full-wave rectification, and the Hilbert transform. Vowels, consonants, and HINT sentences in quiet, as well as with a competing female voice served as test materials. RESULTS: Experiment 1 found significant improvement in all speech tests with a higher number of stimulating electrodes. Experiment 2 found a significant advantage of the high stimulation rate only on consonant recognition and sentence recognition in noise. Experiment 3 found an almost linear trade-off between the number of stimulation electrodes and the stimulation rate for consonant and sentence recognition in quiet, but not for vowel and sentence recognition in noise. Experiment 4 found significantly better performance with the Hilbert transform and the full-wave rectification than the half-wave rectification. In addition, envelope extraction with the Hilbert transform produced the highest rating on subjective judgment of sound quality. CONCLUSIONS: Consistent with previous studies, the present result from the five MED-EL subjects showed that (1) the temporal envelope cues from a limited number of channels are sufficient to support high levels of phoneme and sentence recognition in quiet but not for speech recognition in a competing voice, (2) consonant recognition relies more on temporal cues while vowel recognition relies more on spectral cues, (3) spectral and temporal cues can be traded to some degree to produce similar performance in cochlear implant speech recognition, and (4) the Hilbert envelope improves both speech intelligibility and quality in cochlear implants.

Adult↗

Unintelligible low-frequency sound enhances simulated cochlear-implant speech recognition in noise.

Speech can be recognized by multiple acoustic cues in both frequency and time domains. These acoustic cues are often thought to be redundant. One example is the low-frequency sound component below 300 Hz, which is not even transmitted by the majority of communication devices including telephones. Here, we showed that this low-frequency sound component, although unintelligible when presented alone, could improve the functional signal-to-noise ratio (SNR) by 10-15 dB for speech recognition in noise when presented in combination with a cochlear-implant simulation. A similar low-frequency enhancement effect could be obtained by presenting the low-frequency sound component to one ear and the cochlear-implant simulation to the other ear. However, a high-frequency sound could not produce a similar speech enhancement in noise. We argue that this low-frequency enhancement effect cannot be due to linear addition of intelligibility between low- and high-frequency components or an increase in the physical SNR. We suggest a brain-based mechanism that uses the voice pitch cue in the low-frequency sound to first segregate the target voice from the competing voice and then to group appropriate temporal envelope cues in the target voice for robust speech recognition under realistic listening situations.

Acoustic Stimulation↗

Temporal properties in clear speech perception.

Three experiments were conducted to study relative contributions of speaking rate, temporal envelope, and temporal fine structure to clear speech perception. Experiment I used uniform time scaling to match the speaking rate between clear and conversational speech. Experiment II decreased the speaking rate in conversational speech without processing artifacts by increasing silent gaps between phonetic segments. Experiment III created "auditory chimeras" by mixing the temporal envelope of clear speech with the fine structure of conversational speech, and vice versa. Speech intelligibility in normal-hearing listeners was measured over a wide range of signal-to-noise ratios to derive speech reception thresholds (SRT). The results showed that processing artifacts in uniform time scaling, particularly time compression, reduced speech intelligibility. Inserting gaps in conversational speech improved the SRT by 1.3 dB, but this improvement might be a result of increased short-term signal-to-noise ratios during level normalization. Data from auditory chimeras indicated that the temporal envelope cue contributed more to the clear speech advantage at high signal-to-noise ratios, whereas the temporal fine structure cue contributed more at low signal-to-noise ratios. Taken together, these results suggest that acoustic cues for the clear speech advantage are multiple and distributed.

Analysis of Variance↗

Effects of directional microphone and adaptive multichannel noise reduction algorithm on cochlear implant performance.

Although cochlear implant (CI) users have enjoyed good speech recognition in quiet, they still have difficulties understanding speech in noise. We conducted three experiments to determine whether a directional microphone and an adaptive multichannel noise reduction algorithm could enhance CI performance in noise and whether Speech Transmission Index (STI) can be used to predict CI performance in various acoustic and signal processing conditions. In Experiment I, CI users listened to speech in noise processed by 4 hearing aid settings: omni-directional microphone, omni-directional microphone plus noise reduction, directional microphone, and directional microphone plus noise reduction. The directional microphone significantly improved speech recognition in noise. Both directional microphone and noise reduction algorithm improved overall preference. In Experiment II, normal hearing individuals listened to the recorded speech produced by 4- or 8-channel CI simulations. The 8-channel simulation yielded similar speech recognition results as in Experiment I, whereas the 4-channel simulation produced no significant difference among the 4 settings. In Experiment III, we examined the relationship between STIs and speech recognition. The results suggested that STI could predict actual and simulated CI speech intelligibility with acoustic degradation and the directional microphone, but not the noise reduction algorithm. Implications for intelligibility enhancement are discussed.

Adult↗

Temporal and spectral cues in Mandarin tone recognition.

This study evaluates the relative contributions of envelope and fine structure cues in both temporal and spectral domains to Mandarin tone recognition in quiet and in noise. Four sets of stimuli were created. Noise-excited vocoder speech was used to evaluate the temporal envelope. Frequency modulation was then added to evaluate the temporal fine structure. Whispered speech was used to evaluate the spectral envelope. Finally, equal-amplitude harmonics were used to evaluate the spectral fine structure. Results showed that normal-hearing listeners achieved nearly perfect tone recognition with either spectral or temporal fine structure in quiet, but only 70%-80% correct with the envelope cues. With the temporal envelope, 32 spectral bands were needed to achieve performance similar to that obtained with the original stimuli, but only four bands were necessary with the additional temporal fine structure. Envelope cues were more susceptible to noise than fine structure cues, with the envelope cues producing significantly lower performance in noise. These findings suggest that tonal pattern recognition is a robust process that can make use of both spectral and temporal cues. Unlike speech recognition, the fine structure is more important than the envelope for tone recognition in both temporal and spectral domains, particularly in noise.

Acoustic Stimulation↗

Speech recognition with amplitude and frequency modulations.

Amplitude modulation (AM) and frequency modulation (FM) are commonly used in communication, but their relative contributions to speech recognition have not been fully explored. To bridge this gap, we derived slowly varying AM and FM from speech sounds and conducted listening tests using stimuli with different modulations in normal-hearing and cochlear-implant subjects. We found that although AM from a limited number of spectral bands may be sufficient for speech recognition in quiet, FM significantly enhances speech recognition in noise, as well as speaker and tone recognition. Additional speech reception threshold measures revealed that FM is particularly critical for speech recognition with a competing voice and is independent of spectral resolution and similarity. These results suggest that AM and FM provide independent yet complementary contributions to support robust speech recognition under realistic listening situations. Encoding FM may improve auditory scene analysis, cochlear-implant, and audiocoding performance.

Cochlear Implants↗

Temporal masking in electric hearing.

Temporal masking can be defined as the detection threshold of a brief signal as a function of the signal delay in a relatively long masker. The temporal masking pattern in normal acoustic hearing reveals temporal edge enhancement in which the signal detection threshold is greater near the masker onset than in the steady-state portion. Both peripheral and central mechanisms appear to underlie temporal edge enhancement, but their relative contributions remain elusive. Cochlear implants bypass cochlear mechanical processing and stimulate the auditory nerve directly, thereby providing a unique opportunity to separate the peripheral mechanisms from the central mechanisms. Here, we systematically measured temporal masking in electric hearing by examining whether a brief signal was harder to detect at the onset than in the steady-state portion of a long masker (the "overshoot" effect). The signal and the masker were presented (1) either to the same electrode or to different electrodes, (2) at the same stimulation or different rates, and (3) in a simultaneous or an interleaved fashion. A consistent pattern of results was observed, depending on the stimulus configuration between the signal and the masker. Simultaneous stimulation at the same rate and with the same electrode produced no difference in sensitivity between the onset and the steady-state conditions, but interleaved stimulation at different rates or with different electrodes produced a significant difference. Unlike acoustic hearing, high masker levels produced an overshoot effect, and low masker levels produced an undershoot effect. Although the present results are consistent with the "on-frequency vs. off-frequency" hypothesis for the overshoot effect, results also suggest a central "same vs. different" mechanism underlying temporal masking. These results have practical implications for improving cochlear implant design.

Acoustic Stimulation↗

Encoding frequency modulation to improve cochlear implant performance in noise.

Different from traditional Fourier analysis, a signal can be decomposed into amplitude and frequency modulation components. The speech processing strategy in most modern cochlear implants only extracts and encodes amplitude modulation in a limited number of frequency bands. While amplitude modulation encoding has allowed cochlear implant users to achieve good speech recognition in quiet, their performance in noise is severely compromised. Here, we propose a novel speech processing strategy that encodes both amplitude and frequency modulations in order to improve cochlear implant performance in noise. By removing the center frequency from the subband signals and additionally limiting the frequency modulation's range and rate, the present strategy transforms the fast-varying temporal fine structure into a slowly varying frequency modulation signal. As a first step, we evaluated the potential contribution of additional frequency modulation to speech recognition in noise via acoustic simulations of the cochlear implant. We found that while amplitude modulation from a limited number of spectral bands is sufficient to support speech recognition in quiet, frequency modulation is needed to support speech recognition in noise. In particular, improvement by as much as 71 percentage points was observed for sentence recognition in the presence of a competing voice. The present result strongly suggests that frequency modulation be extracted and encoded to improve cochlear implant performance in realistic listening situations. We have proposed several implementation methods to stimulate further investigation. Index Terms-Amplitude modulation, cochlear implant, fine structure, frequency modulation, signal processing, speech recognition, temporal envelope.

Algorithms↗

Speech and melody recognition in binaurally combined acoustic and electric hearing.

Speech recognition in noise and music perception is especially challenging for current cochlear implant users. The present study utilizes the residual acoustic hearing in the nonimplanted ear in five cochlear implant users to elucidate the role of temporal fine structure at low frequencies in auditory perception and to test the hypothesis that combined acoustic and electric hearing produces better performance than either mode alone. The first experiment measured speech recognition in the presence of competing noise. It was found that, although the residual low-frequency (<1000 Hz) acoustic hearing produced essentially no recognition for speech recognition in noise, it significantly enhanced performance when combined with the electric hearing. The second experiment measured melody recognition in the same group of subjects and found that, contrary to the speech recognition result, the low-frequency acoustic hearing produced significantly better performance than the electric hearing. It is hypothesized that listeners with combined acoustic and electric hearing might use the correlation between the salient pitch in low-frequency acoustic hearing and the weak pitch in the envelope to enhance segregation between signal and noise. The present study suggests the importance and urgency of accurately encoding the fine-structure cue in cochlear implants.

Acoustic Stimulation↗

Pitch discrimination of patterned electric stimulation.

One reason for the poor pitch performance in current cochlear-implant users may be the highly synchronized neural firing in electric hearing that lacks stochastic properties of neural firing in normal acoustic hearing. This study used three different electric stimulation patterns, jittered, probabilistic, and auditory-model-generated pulses, to mimic some aspects of the normal neural firing pattern in acoustic hearing. Pitch discrimination was measured at standard frequencies of 100, 250, 500, and 1000 Hz on three Nucleus-24 cochlear-implant users. To test the utility of the autocorrelation pitch perception model in electric hearing, one, two, and four electrodes were stimulated independently with the same patterned electric stimulation. Results showed no improvement in performance with any experimental pattern compared to the fixed-rate control. Pitch discrimination was actually worsened with the jittered pattern at low frequencies (125 and 250 Hz) than that of the control, suggesting that externally introduced stochastic properties do not improve pitch perception in electric stimulation. The multiple-electrode stimulation did not improve performance but did not degrade performance either. The present results suggest that both "the right time and the right place" may be needed to restore normal pitch perception in cochlear-implant users.

Aged↗

Speaker recognition with temporal cues in acoustic and electric hearing.

Natural spoken language processing includes not only speech recognition but also identification of the speaker's gender, age, emotional, and social status. Our purpose in this study is to evaluate whether temporal cues are sufficient to support both speech and speaker recognition. Ten cochlear-implant and six normal-hearing subjects were presented with vowel tokens spoken by three men, three women, two boys, and two girls. In one condition, the subject was asked to recognize the vowel. In the other condition, the subject was asked to identify the speaker. Extensive training was provided for the speaker recognition task. Normal-hearing subjects achieved nearly perfect performance in both tasks. Cochlear-implant subjects achieved good performance in vowel recognition but poor performance in speaker recognition. The level of the cochlear implant performance was functionally equivalent to normal performance with eight spectral bands for vowel recognition but only to one band for speaker recognition. These results show a disassociation between speech and speaker recognition with primarily temporal cues, highlighting the limitation of current speech processing strategies in cochlear implants. Several methods, including explicit encoding of fundamental frequency and frequency modulation, are proposed to improve speaker recognition for current cochlear implant users.

Acoustic Stimulation↗