PubMed Health⌕ Search

Biomedical subjects

Fan-ping Meng

Publications and source records attributed to Fan-ping Meng.

2 recordsLinked to original sources

[Construction and expression of a fusion protein of scFv against human acetylcholine receptor-human serum albumin in E. coli].

AIM: To prepare the fusion protein of a single chain variable fragment 637 (scFv637) against human acetylcholine receptor (AChR) and human serum albumin (HSA) to increase the stability of scFv637. METHODS: HSA gene was amplified by PCR and cloned into vector pHEN2 containing a scFv637 gene to construct recombinant vector pHEN2-scFv637-HSA and then transformed into E. coli HB2151 for expression. The expression of fusion protein in periplasm of E. coli was detected by dot hybridization. Relative molecular mass of fusion protein was checked by SDS-PAGE and Western blot. RESULTS: Agarose gel electrophoresis analysis showed that the size of HSA gene and fusion gene was about 1,770 bp and 7,054 bp, respectively. DNA sequencing proved that the nucleotide sequence of constructed scFv637-HSA gene was correct and it was cloned into the open reading frame (ORF) of pHEN2. scFv637-HSA fusion protein only existed in periplasm of E. coli HB2151 transformed with pHEN2-scFv637-HSA. SDS-PAGE and Western blot analysis indicated that relative molecular mass of fusion protein was about 95,900. CONCLUSION: The scFv637-HSA fusion protein can be successfully expressed in E. coli HB2151, which provides a sound basis for further research into its function and clinical application.

Animals↗

[Flow injection biosensor based on the immobilized AChE].

A biosensor based on the flow injection system was constructed with the immobilized AChE from Scomberomorus niphonius (Curier) as identification element and a pH electrode as transducer. When phosphate buffer was used as carrier liquid, a good reproducibility (RSD = 1.427% , n=10) of the biosensor response was obtained after the substrate was injected repetitively. After an incubation time of 20 min, the calibration graph to methyl-parathion is linear (r = 0.9986) when its concentration ranges from 4.29 x 10(-10) mol x L(-1) to 4.29 x 10(-8) mol x L(-1) , and the detection limit is 1.3 x 10(-10) mol x L(-1). However, the sensitivity of this biosensor to methyl-parathion when using clean seawater as carrier liquid is not as good as that using phosphate buffer. But after preoxidation of methyl-parathion with NaClO as oxidant, the detection limit of the biosensor to methyl-parathion in seawater can be improve to 2.16 x 10(-7) mol x L(-1).

Acetylcholinesterase↗