PubMed Health⌕ Search

Biomedical subjects

Fang Zhu

Publications and source records attributed to Fang Zhu.

23 records · Page 2Linked to original sources

Influence of tryptophan on lipid binding of linear amphipathic cationic antimicrobial peptides.

We recently demonstrated that a linear 18-residue peptide, (KIGAKI)(3)-NH(2), designed to form amphipathic beta-sheet structure when bound to lipid bilayers, possessed potent antimicrobial activity and low hemolytic activity. The ability of (KIGAKI)(3)-NH(2) to induce leakage from lipid vesicles was compared to that of the amphipathic alpha-helical peptide, (KIAGKIA)(3)-NH(2), which had equivalent antimicrobial activity. Significantly, the lytic properties of (KIGAKI)(3)-NH(2) were enhanced for mixed acidic-neutral lipid vesicles containing phosphatidylethanolamine instead of phosphatidylcholine as the neutral component, while the potency of (KIAGKIA)(3)-NH(2) was significantly reduced [Blazyk, J., et al. (2001) J. Biol. Chem. 276, 27899-27906]. In this paper, we measured the lytic properties of these peptides, as well as several fluorescent analogues containing a single tryptophan residue, by monitoring permeability changes in large unilamellar vesicles with varying lipid compositions and in Escherichia coli cells. The binding of these peptides to lipid bilayers with defined compositions was compared using surface plasmon resonance, circular dichroism, and fluorescence spectroscopy. Surprisingly large differences were observed in membrane binding properties, particularly in the case of KIGAKIKWGAKIKIGAKI-NH(2). Since all of these peptides possess the same charge and very similar mean hydrophobicities, the binding data cannot be explained merely in terms of electrostatic and/or hydrophobic interactions. In light of their equivalent antimicrobial and hemolytic potencies, some of these peptides may employ mechanisms beyond simply increasing plasma membrane permeability to exert their lethal effects.

Amino Acid Sequence↗

Improving mass measurement of coronary artery calcification using threshold correction and thin collimation in multi-detector row computed tomography: in vitro experiment.

RATIONALE AND OBJECTIVES: This in vitro study was designed to improve the accuracy of coronary calcium mass measurement from computed tomography (CT) images by developing threshold-based calcium CT number correction and thin-slice spiral techniques. MATERIALS AND METHODS: A cardiac CT phantom containing simulated calcified cylinders of known calcium density was scanned with sequential 4 x 2.5-, spiral 16 x 1.5-, and spiral 16 x 0.75-mm collimation on 4- and 16-detector row CT scanners. The images obtained from the spiral scans were reconstructed in various slice widths. The calcified cylinders were imaged and their mean CT number and size were measured at thresholds ranging from 50 to 390 Hounsfield unit. The calcium mass measured was compared with the actual value to determine errors, and threshold-based correction factors were derived to minimize the errors. RESULTS: The minimum amount of measurable calcium in 1-mm cylinder was 0.3 mg at the 16 X 1.5-mm protocol and 0.2 mg at the 16 x 0.75-mm protocol. Compared with 2.5-mm sequential protocol, thin-slice spiral protocols yielded a higher radiation exposure and lower or similar image noise levels. The error in calcium mass after correction was significantly smaller than that in measured mass (P < .0001) and was consistent between the imaging protocols (P = .49). The accuracy of mass measurements was clearly improved by using thin-slice imaging protocols especially in 200-mg/cm3 calcium density (P < .0001). CONCLUSION: The accuracy of calcium mass CT measurement can be improved by threshold-based calcium CT number correction and thin collimation spiral techniques.

Calcinosis↗

Coronary artery calcium quantification at multi-detector row CT: influence of heart rate and measurement methods on interacquisition variability initial experience.

PURPOSE: To assess the effect of heart rate on interacquisition variability in different coronary calcium quantification methods at multi-detector row computed tomography (CT). MATERIALS AND METHODS: Fifty consecutive adults (39 men and 11 women; mean age, 57 years +/- 13 [SD]) with various heart rates were examined with two prospectively electrocardiographically triggered multi-detector row CT acquisitions in succession for detection and quantification of coronary artery calcification. Calcium score, volume, and mass were measured for each acquisition. Interacquisition variability was evaluated in association with heart rate and quantification method in subjects and individual coronary vessels by using t tests and analysis of variance. RESULTS: In 37 subjects with detected calcium, interacquisition variability in mass measurement (10.4%) was significantly lower than that in score (23.9%) and volume (15.7%) measurements (P <.02). The interacquisition variability in all quantification methods was well correlated with heart rate and was considerably greater when heart rates were higher than 70 beats per minute (bpm) than when heart rates were 70 bpm or lower (P <.002). There was a clear tendency for interacquisition variability to vary by vessel (P <.01). The correlation of interacquisition variability with heart rate and a significant difference in interacquisition variability between the group with heart rates of 70 bpm or lower and the group with rates higher than 70 bpm (P <.02) were found for the left main and left anterior descending arteries but not for the circumflex and right coronary arteries. CONCLUSION: Interacquisition variability in coronary calcium measurements at multi-detector row CT is significantly less at lower heart rates. The coronary calcium mass measurement is more reproducible than are score and volume measurements.

Adult↗

The application of virtual endoscopy with computed tomography in maxillofacial surgery.

OBJECTIVE: To use virtual endoscopy to obtain detailed three-dimensional images of bone, soft tissue and paranasal sinus damage as well as images of adjacent unaffected areas for optimum surgical planning. METHODS: A spiral CT scanner was used to examine 46 cases of facial bone fractures, maxillary cysts, obstructive sleep apnea syndrome (OSAS) and maxillary bone tumours. Data were input into a navigator workstation to create images similar to those displayed by a fiberoptic endoscope. Various 3-D images were obtained when probe sites were changed. RESULTS: Virtual endoscopy can clearly display the anatomic structure of the paranasal sinuses, nasopharyngeal cavity and upper respiratory tract, revealing damage to the sinus wall caused by a bone tumor or fracture. In addition, the technique can be used to indicate volume changes of the upper respiratory tract in OSAS patients. These results were similar to those obtained through actual operations. CONCLUSIONS: Virtual endoscopy is a new method which produces very clear images. It is reliable to provide detailed information for optimal operative planning.

Adolescent↗

[The role of urotensin II gene in the genetic susceptibility to type 2 diabetes in Chinese population].

OBJECTIVE: To investigate the relationship between the polymorphism of site rs228648 in urotensin II gene and the genetic susceptibility to type 2 diabetes in Han people. METHODS: Genotyping was conducted to investigate the polymorphism of site rs228648 (G-A) in urotensin II gene among 166 unrelated type 2 diabetic subjects (case group 1), 87 probands from 87 families of type 2 diabetics (case group 2), and 121 non-diabetic normal controls (control group). RESULTS: 1) The frequency of "G" allele of site rs228648 was 62.3% and 75.3% in case group 1 and case group 2 respectively, significantly higher than that in the control group (50.4%, P = 0.004 and P < 0.001). 2) The frequency of G/G genotype of rs228648 was 35% and 53% in case group 1 and case group 2 respectively, significantly higher than that in the control group (24%, P < 0.05 and P < 0.01). The odds ratio was 1.86, P = 0.041 in the case group 1 and 4.03, P < 0.001 in the case control 2 after adjustment by sex, age and BMI. CONCLUSION: Urotensin II gene may contribute to the genetic susceptibility to type 2 diabetes in Han population.

Adult↗