A methodology for using SPECT to reduce intensity-modulated radiation therapy (IMRT) dose to functioning lung.

PURPOSE: Single photon emission computed tomography (SPECT) provides a map of the spatial distribution of lung perfusion. Thus, SPECT guidance can be used to divert dose away from higher-functioning lung, potentially reducing lung toxicity. We present a methodology for achieving this aim and test it in intensity-modulated radiotherapy (IMRT) treatment-planning. METHODS AND MATERIALS: IMRT treatment plans were generated with and without SPECT guidance and compared for 5 patients. Healthy lung was segmented into four regions on the basis of SPECT intensity in the SPECT plan. Dose was sequentially allowed to the target via regions of increasing SPECT intensity. This process results in reduction of dose to functional lung, reflected in the dose-function histogram (DFH). The plans were compared using DFHs and F(20)/F(30) values (F(x) is the functional lung receiving dose above x Gy). RESULTS: In all cases, the SPECT-guided plan produced a more favorable DFH compared with the non-SPECT-guided plan. Additionally, the F(20) and F(30) values were reduced for all patients by an average of 13.6% +/- 5.2% and 10.5% +/- 5.8%, respectively. In all patients, DFHs of the two highest-functioning SPECT regions were reduced, whereas DFHs of the two lower-functioning regions were increased, illustrating the dose "give-take" between SPECT regions during redistribution. CONCLUSIONS: SPECT-guided IMRT shows potential for reducing the dose delivered to highly functional lung regions. This dose reduction could reduce the number of high-grade pneumonitis cases that develop after radiation treatment and improve patient quality of life.

Algorithms↗

Dosimetric feasibility of cone-beam CT-based treatment planning compared to CT-based treatment planning.

PURPOSE: Cone-beam computed tomography (CBCT) images are currently used for positioning verification. However, it is yet unknown whether CBCT could be used in dose calculation for replanning in adaptive radiation therapy. This study investigates the dosimetric feasibility of CBCT-based treatment planning. METHODS AND MATERIALS: Hounsfield unit (HU) values and profiles of Catphan, homogeneous/inhomogeneous phantoms, and various tissue regions of patients in CBCT images were compared to those in CT. The dosimetric consequence of the HU variation was investigated by comparing CBCT-based treatment plans to conventional CT-based plans for both phantoms and patients. RESULTS: The maximum HU difference between CBCT and CT of Catphan was 34 HU in the Teflon. The differences in other materials were less than 10 HU. The profiles for the homogeneous phantoms in CBCT displayed reduced HU values up to 150 HU in the peripheral regions compared to those in CT. The scatter and artifacts in CBCT became severe surrounding inhomogeneous tissues with reduced HU values up to 200 HU. The MU/cGy differences were less than 1% for most phantom cases. The isodose distributions between CBCT-based and CT-based plans agreed very well. However, the discrepancy was larger when CBCT was scanned without a bowtie filter than with bowtie filter. Also, up to 3% dosimetric error was observed in the plans for the inhomogeneous phantom. In the patient studies, the discrepancies of isodose lines between CT-based and CBCT-based plans, both 3D and IMRT, were less than 2 mm. Again, larger discrepancy occurred for the lung cancer patients. CONCLUSION: This study demonstrated the feasibility of CBCT-based treatment planning. CBCT-based treatment plans were dosimetrically comparable to CT-based treatment plans. Dosimetric data in the inhomogeneous tissue regions should be carefully validated.

Brain Neoplasms↗

Digital tomosynthesis with an on-board kilovoltage imaging device.

PURPOSE: To generate on-board digital tomosynthesis (DTS) and reference DTS images for three-dimensional image-guided radiation therapy (IGRT) as an alternative to conventional portal imaging or on-board cone-beam computed tomography (CBCT). METHODS AND MATERIALS: Three clinical cases (prostate, head-and-neck, and liver) were selected to illustrate the capabilities of on-board DTS for IGRT. Corresponding reference DTS images were reconstructed from digitally reconstructed radiographs computed from planning CT image sets. The effect of scan angle on DTS slice thickness was examined by computing the mutual information between coincident CBCT and DTS images, as the DTS scan angle was varied from 0 degrees to 165 degrees . A breath-hold DTS acquisition strategy was implemented to remove respiratory motion artifacts. RESULTS: Digital tomosynthesis slices appeared similar to coincident CBCT planes and yielded substantially more anatomic information than either kilovoltage or megavoltage radiographs. Breath-hold DTS acquisition improved soft-tissue visibility by suppressing respiratory motion. CONCLUSIONS: Improved bony and soft-tissue visibility in DTS images is likely to improve target localization compared with radiographic verification techniques and might allow for daily localization of a soft-tissue target. Breath-hold DTS is a potential alternative to on-board CBCT for sites prone to respiratory motion.

Algorithms↗

A technique of using gated-CT images to determine internal target volume (ITV) for fractionated stereotactic lung radiotherapy.

BACKGROUND AND PURPOSE: To develop and evaluate a technique and procedure of using gated-CT images in combination with PET image to determine the internal target volume (ITV), which could reduce the planning target volume (PTV) with adequate target coverage. PATIENTS AND METHODS: A skin marker-based gating system connected to a regular single slice CT scanner was used for this study. A motion phantom with adjustable motion amplitude was used to evaluate the CT gating system. Specifically, objects of various sizes/shapes, considered as virtual tumors, were placed on the phantom to evaluate the number of phases of gated images required to determine the ITV while taking into account tumor size, shape and motion. A procedure of using gated-CT and PET images to define ITV for patients was developed and was tested in patients enrolled in an IRB approved protocol. RESULTS: The CT gating system was capable of removing motion artifacts for target motion as large as 3-cm when it was gated at optimal phases. A phantom study showed that two gated-CT scans at the end of expiration and the end of inspiration would be sufficient to determine the ITV for tumor motion less than 1-cm, and another mid-phase scan would be required for tumors with 2-cm motion, especially for small tumors. For patients, the ITV encompassing visible tumors in all sets of gated-CT and regular spiral CT images seemed to be consistent with the target volume determined from PET images. PTV expanded from the ITV with a setup uncertainty margin had less volume than PTVs from spiral CT images with a 10-mm generalized margin or an individualized margin determined at fluoroscopy. CONCLUSIONS: A technique of determining the ITV using gated-CT images was developed and was clinically implemented successfully for fractionated stereotactic lung radiotherapy.

Algorithms↗

Physics and imaging for targeting of oligometastases.

Oligometastases refer to metastases that are limited in number and location and are amenable to regional treatment. The majority of these metastases appear in the brain, lung, liver, and bone. Although the focus of interest in the past within radiation oncology has been on the treatment of intracranial metastases, there has been growing interest in extracranial sites such as the liver and lung. This is largely because of the rapid development of targeting techniques for oligometastases such as intensity-modulated and image-guided radiation therapy, which has made it possible to deliver single or a few fractions of high-dose radiation treatments, highly conformal to the target. The clinical decision to use radiation to treat oligometastases is based on both radiobiological and physics considerations. The radiobiological considerations involve improvement of treatment schema for time, dose, and volume. Areas of interests are hypofractionation, tumor and normal tissue tolerance, and hypoxia. The physics considerations for oligometastases treatment are focused mainly on ensuring treatment accuracy and precision. This article discusses the physics and imaging aspects involved in each step of the radiation treatment process for oligometastases, including target definition, treatment simulation, treatment planning, pretreatment target localization, radiation delivery, treatment verification, and treatment evaluation.

Dose Fractionation, Radiation↗

The correlation evaluation of a tumor tracking system using multiple external markers.

The purpose of this study is to evaluate the correlations between external markers and internal targets for radiation therapy of lung cancer patients. Using an infrared camera system coupled with a clinical simulator, the simultaneous motions of multiple external markers and an internal target were obtained. The correlation between external and internal signals was analyzed using a cross-covariance function. A linear regression model was employed to generate a composite signal from multiple external markers in order to predict the internal target motion. The external and internal signals, and their correlations, demonstrated a wide range of variation with respect to marker location, motion dimension, and breathing pattern. The performance of the composite signal indicates that when more external signals were taken into account, the mean correlation between the composite signal and internal signal was improved. This implies that a combination of multiple external signals might be an improved way to predict internal target motion. Also, since the characteristics of respiratory signals can vary significantly, certain methods of preprocessing and external signal combination are necessary.

Artifacts↗

A quality assurance program for the on-board imagers.

To develop a quality assurance (QA) program for the On-Board Imager (OBI) system and to summarize the results of these QA tests over extended periods from multiple institutions. Both the radiographic and cone-beam computed tomography (CBCT) mode of operation have been evaluated. The QA programs from four institutions have been combined to generate a series of tests for evaluating the performance of the On-Board Imager. The combined QA program consists of three parts: (1) safety and functionality, (2) geometry, and (3) image quality. Safety and functionality tests evaluate the functionality of safety features and the clinical operation of the entire system during the tube warm-up. Geometry QA verifies the geometric accuracy and stability of the OBI/CBCT hardware/software. Image quality QA monitors spatial resolution and contrast sensitivity of the radiographic images. Image quality QA for CBCT includes tests for Hounsfield Unit (HU) linearity, HU uniformity, spatial linearity, and scan slice geometry, in addition. All safety and functionality tests passed on a daily basis. The average accuracy of the OBI isocenter was better than 1.5 mm with a range of variation of less than 1 mm over 8 months. The average accuracy of arm positions in the mechanical geometry QA was better than 1 mm, with a range of variation of less than 1 mm over 8 months. Measurements of other geometry QA tests showed stable results within tolerance throughout the test periods. Radiographic contrast sensitivity ranged between 2.2% and 3.2% and spatial resolution ranged between 1.25 and 1.6 lp/mm. Over four months the CBCT images showed stable spatial linearity, scan slice geometry, contrast resolution (1%; <7 mm disk) and spatial resolution (>6 lp/cm). The HU linearity was within +/-40 HU for all measurements. By combining test methods from multiple institutions, we have developed a comprehensive, yet practical, set of QA tests for the OBI system. Use of the tests over extended periods show that the OBI system has reliable mechanical accuracy and stable image quality. Nevertheless, the tests have been useful in detecting performance deficits in the OBI system that needed recalibration. It is important that all tests are performed on a regular basis.

Equipment Failure Analysis↗

Postoperative radiosurgery for malignant spinal tumors.

OBJECTIVE: Although, as a primary therapy, radiosurgery for spinal tumors is becoming more common in clinical practice and is associated with encouraging clinical results, we wanted to evaluate outcomes after radiosurgery in a series of postoperative patients. METHODS: We examined the medical records of 18 postoperative patients who received radiosurgical treatment to their residual spinal tumors: metastatic carcinoma (10), sarcoma (3), multiple myeloma/plasmacytoma (4), and giant cell tumor (1). Marginal radiosurgical doses ranged from 6 to 16 Gy (mean, 11.4 Gy) prescribed to the 90% isodose line. All regions of the spine received treatment: 2 cervical, 15 thoracic, and 1 lumbosacral. The volume of irradiated spinal elements receiving 30, 50, and 80% of the total dose ranged from 0.51 to 11.05, 0.19 to 6.34, and 0.06 to 1.73 cm, respectively. Treatment sessions (i.e., patient in to patient out of the room) varied between 20 and 40 minutes. Follow-up ranged from 4 to 36 months (median, 7 mo). RESULTS: Even though significant doses of radiation were delivered to all regions of the spinal cord and nerve roots coincidentally involved in the treatments, only one patient in this series developed progressive symptoms possibly attributable to a toxic effect of the radiosurgery. Of those patients initially presenting with neurological deficits, 92% either remained neurologically stable or improved. CONCLUSION: Our observations suggest that radiosurgery as prescribed in this series of postoperative patients with residual spinal tumor is well-tolerated and associated with little to no significant morbidity.

Adult↗

Adaptive prediction of internal target motion using external marker motion: a technical study.

An adaptive prediction approach was developed to infer internal target position by external marker positions. First, a prediction model (or adaptive neural network) is developed to infer target position from its former positions. For both internal target and external marker motion, two networks with the same type are created. Next, a linear model is established to correlate the prediction errors of both neural networks. Based on this, the prediction error of an internal target position can be reconstructed by the linear combination of the prediction errors of the external markers. Finally, the next position of the internal target is estimated by the network and subsequently corrected by the reconstructed prediction error. In a similar way, future positions are inferred as their previous positions are predicted and corrected. This method was examined by clinical data. The results demonstrated that an improvement (10% on average) of correlation between predicted signal and real internal motion was achieved, in comparison with the correlation between external markers and internal target motion. Based on the clinical data (with correlation coefficient 0.75 on average) observed between external marker and internal target motions, a prediction error (23% on average) of internal target position was achieved. The preliminary results indicated that this method is helpful to improve the predictability of internal target motion with the additional information of external marker signals. A consistent correlation between external and internal signals is important for prediction accuracy.

Algorithms↗

Dosimetric study using different leaf-width MLCs for treatment planning of dynamic conformal arcs and intensity-modulated radiosurgery.

This paper systematically studied the dosimetric difference between a 3 mm micro multileaf collimator (MLC), a 5 mm MLC, and a 10 mm MLC for stereotactic radiosurgery using the Brainscan treatment planning system. Thirty-four cases treated with the dynamic conformal arcs technique and 20 cases treated with the intensity modulated radiosurgery/fractionated radiotherapy (IMRS/ IMRT) technique were retrospectively studied. The conformity index, the percentage target coverage, and the dose-volume histogram (DVH) for organs-at-risk (OARs) were used for dosimetric analysis and comparison for different treatment techniques, target volumes, and treatment sites. For the dynamic conformal arcs technique, there were statistically significant differences in the conformity indices between different leaf-width MLCs. The ratio of the conformity indices between different MLCs depended on the target volume. The average conformity index ratios between the 5 mm MLC and the 3 mm MLC were 1.37+/-0.09, 1.12+/-0.04, 1.08+/-0.02 and 1.04+/-0.01, respectively, for patients with the target volume (V) in groups: (1) V< 1 cm3, (2) 1 cm3 < V< 8 cm3, (3) 8 cm3 < V< 27 cm3, and (4) V> 27 CC. The average conformity index ratios between the 10 and 3 mm MLCs were 2.00+/-0.33, 1.45+/-0.09, 1.28+/-0.09, and 1.18+/-0.05 for patients in these four volume groups, respectively. No statistically significant difference was found for the target coverage among different MLCs. For the IMRS/IMRT technique, the average conformity index and target coverage ratios were 1.01+/-0.05 and 1.00+/-0.02, respectively, between the 5 and 3 mm MLCs, and were 1.04+/-0.07 and 0.97+/-0.02, respectively, between the 10 and 3 mm MLCs. The 3 mm MLC showed slightly better overall OAR DVHs than the 5 and 10 mm MLCs, especially for the cranial site with small-volume OARs defined. The results suggest that for the dynamic conformal arcs technique, the narrower leaf-width MLC provides better dose conformity than the wider leaf-width MLCs. This advantage decreases when the target volume increases. For the IMRS/IMRT technique, the narrower leaf-width MLC could have better sparing of small OARs than the wider leaf-width MLC.

Body Burden↗

Effects of x-ray and CT image enhancements on the robustness and accuracy of a rigid 3D/2D image registration.

A rigid body three-dimensional/two-dimensional (3D/2D) registration method has been implemented using mutual information, gradient ascent, and 3D texturemap-based digitally reconstructed radiographs. Nine combinations of commonly used x-ray and computed tomography (CT) image enhancement methods, including window leveling, histogram equalization, and adaptive histogram equalization, were examined to assess their effects on accuracy and robustness of the registration method. From a set of experiments using an anthropomorphic chest phantom, we were able to draw several conclusions. First, the CT and x-ray preprocessing combination with the widest attraction range was the one that linearly stretched the histograms onto the entire display range on both CT and x-ray images. The average attraction ranges of this combination were 71.3 mm and 61.3 deg in the translation and rotation dimensions, respectively, and the average errors were 0.12 deg and 0.47 mm. Second, the combination of the CT image with tissue and bone information and the x-ray images with adaptive histogram equalization also showed subvoxel accuracy, especially the best in the translation dimensions. However, its attraction ranges were the smallest among the examined combinations (on average 36 mm and 19 deg). Last the bone-only information on the CT image did not show convergency property to the correct registration.

Algorithms↗

Time delay measurement for linac based treatment delivery in synchronized respiratory gating radiotherapy.

A time delay in a respiratory gating system could cause an unexpected phase mismatch for synchronized gating radiotherapy. This study presents a method of identifying and measuring the time delay in a gating system. Various port films were taken for a motion phantom at different gating window levels with a very narrow window size. The time delay for the gating system was determined by comparing the motion curve (the position of a moving object versus the gating time) measured in the port films to the motion curve determined by the video cameras. The measured time delay for a linac-based gating system was 0.17+/-0.03 s. This time delay could induce target missing if it was not properly taken into account for the synchronized gating radiotherapy. Measurement/verification of the time delay should be considered as an important part of the accepting/commissioning test before the clinical use of the gating system.

Equipment Design↗

A technique for on-board CT reconstruction using both kilovoltage and megavoltage beam projections for 3D treatment verification.

The technologies with kilovoltage (kV) and megavoltage (MV) imaging in the treatment room are now available for image-guided radiation therapy to improve patient setup and target localization accuracy. However, development of strategies to efficiently and effectively implement these technologies for patient treatment remains challenging. This study proposed an aggregated technique for on-board CT reconstruction using combination of kV and MV beam projections to improve the data acquisition efficiency and image quality. These projections were acquired in the treatment room at the patient treatment position with a new kV imaging device installed on the accelerator gantry, orthogonal to the existing MV portal imaging device. The projection images for a head phantom and a contrast phantom were acquired using both the On-Board Imager kV imaging device and the MV portal imager mounted orthogonally on the gantry of a Varian Clinac 21EX linear accelerator. MV projections were converted into kV information prior to the aggregated CT reconstruction. The multilevel scheme algebraic-reconstruction technique was used to reconstruct CT images involving either full, truncated, or a combination of both full and truncated projections. An adaptive reconstruction method was also applied, based on the limited numbers of kV projections and truncated MV projections, to enhance the anatomical information around the treatment volume and to minimize the radiation dose. The effects of the total number of projections, the combination of kV and MV projections, and the beam truncation of MV projections on the details of reconstructed kV/MV CT images were also investigated.

Humans↗

A novel needle-based miniature x-ray generating system.

The basic concept, design and performance of a novel needle-based x-ray system for medical applications are reported. The main principle of the system is based on a two-stage production of x-rays. The system comprises a conventional x-ray tube with an Ag anode, any known type of conditioning optics and a 2.2 mm diameter hollow needle with an interchangeable Mo target. The target can be moved along the needle axis and rotated around the needle axis. The needle x-ray device allows for adjustment in energy and flux intensity of the x-rays emitted by the target. The depth dependence of the intensity, dose rate as well as spatial and energy distribution of the radiation emitted by the target have been experimentally measured. The depth dose rate results have been compared with theoretical calculations using a Monte Carlo simulation of the x-ray production process. These studies have experimentally confirmed that the concept of this x-ray system is correct. Further improvement of the device can increase the dose rate up to the levels required for clinical applications.

Brachytherapy↗

Novalis radiosurgery for metastatic spine tumors.

It is logical to anticipate that the field of spinal radiosurgery will evolve in a fashion similar to that seen for intracranial radiosurgery. Given the frequency of various pathologic entities that affect the spine, including those that have proven to be largely intractable to surgery, radiation, and chemotherapy (eg, sarcomas), and the serious clinical, economic and quality-of-life consequences of paraplegia, radiosurgery offers new hope as an adjuvant or primary therapy. The meticulous application of well-designed investigations of relevant clinical outcomes will be critical to the appropriate and effective use of this technology.

Humans↗

Image-guided radiosurgery of head and neck cancers.

OBJECTIVES: Radiosurgery precisely delivers a single high dose or a few fractionated doses of radiation to a localized tumor via the stereotactic approach. Some head and neck sites are suitable for radiosurgery since there is minimal or no organ motion. The clinical studies were carried out to determine the accuracy of stereotactic radiosurgery and to demonstrate the effectiveness of radiosurgery in head and neck cancers. MATERIALS AND METHODS: Thirteen patients were treated with either single-dose or fractionated radiosurgery to the tumor. All patients except one with cancer of the lip had received prior treatments including surgery, radiotherapy, and chemotherapy for the primary cancers. The dose ranged 12 to 18 Gy for single-dose radiosurgery and 30 Gy in 5 or 6 fractions twice a week for fractionated radiosurgery. Tumor localization was achieved via the stereotactic approach. RESULTS: Accuracy of radiosurgery was within 1.5 mm. Despite the recurrent disease from previous heavy treatments, 9 patients (70%) showed a significant response (complete or >50% tumor reduction) to radiosurgery, and 3 patients had stable disease. Complete tumor response was achieved in 6 patients. All patients had excellent pain relief with functional and cosmetic preservation. There was no acute and subacute radiation toxicity detected clinically during the minimal follow-up of 6 months. CONCLUSION: Image-guided radiosurgery is effective in achieving the local tumor control and pain relief. Radiosurgery provided excellent functional and cosmetic preservation with minimal complication. The results indicate the potential of radiosurgery in the treatment of recurrent and selected primary head and neck cancers.

Carcinoma, Squamous Cell↗

A quantitative method for measuring gene expression magnitude and volume delivered by gene therapy vectors.

This study describes a quantitative method to measure the magnitude and distribution of gene expression following local delivery of an adenoviral vector containing the human sodium iodide symporter (hNIS) reporter gene into the canine prostate. Following systemic administration of Na(99m)TcO(4), autoradiographs of prostate sections depicting hNIS-dependent (99m)TcO(4)(-) uptake were digitized and stacked to produce a three-dimensional reconstruction of gene expression. Frequency histograms reflecting hNIS gene expression magnitude and volume were used to quantify hNIS function. The method demonstrated submillimeter resolution allowing for precise measurements of gene expression magnitude and volume in vivo. The method developed here could be applied to other reporter gene systems in which the readout can be digitized from thin tissue sections.

Adenoviridae↗

Adaptive algebraic reconstruction technique.

Algebraic reconstruction techniques (ART) are iterative procedures for reconstructing objects from their projections. It is proven that ART can be computationally efficient by carefully arranging the order in which the collected data are accessed during the reconstruction procedure and adaptively adjusting the relaxation parameters. In this paper, an adaptive algebraic reconstruction technique (AART), which adopts the same projection access scheme in multilevel scheme algebraic reconstruction technique (MLS-ART), is proposed. By introducing adaptive adjustment of the relaxation parameters during the reconstruction procedure, one-iteration AART can produce reconstructions with better quality, in comparison with one-iteration MLS-ART. Furthermore, AART outperforms MLS-ART with improved computational efficiency.

Algorithms↗