PubMed Health⌕ Search

Biomedical subjects

Fani Deligianni

Publications and source records attributed to Fani Deligianni.

6 recordsLinked to original sources

Patient-specific bronchoscopy visualization through BRDF estimation and disocclusion correction.

This paper presents an image-based method for virtual bronchoscope with photo-realistic rendering. The technique is based on recovering bidirectional reflectance distribution function (BRDF) parameters in an environment where the choice of viewing positions, directions, and illumination conditions are restricted. Video images of bronchoscopy examinations are combined with patient-specific three-dimensional (3-D) computed tomography data through two-dimensional (2-D)/3-D registration and shading model parameters are then recovered by exploiting the restricted lighting configurations imposed by the bronchoscope. With the proposed technique, the recovered BRDF is used to predict the expected shading intensity, allowing a texture map independent of lighting conditions to be extracted from each video frame. To correct for disocclusion artefacts, statistical texture synthesis was used to recreate the missing areas. New views not present in the original bronchoscopy video are rendered by evaluating the BRDF with different viewing and illumination parameters. This allows free navigation of the acquired 3-D model with enhanced photo-realism. To assess the practical value of the proposed technique, a detailed visual scoring that involves both real and rendered bronchoscope images is conducted.

Algorithms↗

Nonrigid 2-D/3-D registration for patient specific bronchoscopy simulation with statistical shape modeling: phantom validation.

This paper presents a nonrigid registration two-dimensional/three-dimensional (2-D/3-D) framework and its phantom validation for subject-specific bronchoscope simulation. The method exploits the recent development of five degrees-of-freedom miniaturized catheter tip electromagnetic trackers such that the position and orientation of the bronchoscope can be accurately determined. This allows the effective recovery of unknown camera rotation and airway deformation, which is modelled by an active shape model (ASM). ASM captures the intrinsic variability of the tracheo-bronchial tree during breathing and it is specific to the class of motion it represents. The method reduces the number of parameters that control the deformation, and thus greatly simplifies the optimisation procedure. Subsequently, pq-based registration is performed to recover both the camera pose and parameters of the ASM. Detailed assessment of the algorithm is performed on a deformable airway phantom, with the ground truth data being provided by an additional six degrees-of-freedom electromagnetic (EM) tracker to monitor the level of simulated respiratory motion.

Algorithms↗

Gaze-contingent soft tissue deformation tracking for minimally invasive robotic surgery.

The introduction of surgical robots in Minimally Invasive Surgery (MIS) has allowed enhanced manual dexterity through the use of microprocessor controlled mechanical wrists. Although fully autonomous robots are attractive, both ethical and legal barriers can prohibit their practical use in surgery. The purpose of this paper is to demonstrate that it is possible to use real-time binocular eye tracking for empowering robots with human vision by using knowledge acquired in situ. By utilizing the close relationship between the horizontal disparity and the depth perception varying with the viewing distance, it is possible to use ocular vergence for recovering 3D motion and deformation of the soft tissue during MIS procedures. Both phantom and in vivo experiments were carried out to assess the potential frequency limit of the system and its intrinsic depth recovery accuracy. The potential applications of the technique include motion stabilization and intra-operative planning in the presence of large tissue deformation.

Artificial Intelligence↗

Predictive camera tracking for bronchoscope simulation with CONDensation.

This paper exploits the use of temporal information to minimize the ambiguity of camera motion tracking in bronchoscope simulation. The condensation algorithm (Sequential Monte Carlo) has been used to propagate the probability distribution of the state space. For motion prediction, a second-order auto-regressive model has been used to characterize camera motion in a bounded lumen as encountered in bronchoscope examination. The method caters for multimodal probability distributions, and experimental results from both phantom and patient data demonstrate a significant improvement in tracking accuracy especially in cases where there is airway deformation and image artefacts.

Algorithms↗

Soft-tissue motion tracking and structure estimation for robotic assisted MIS procedures.

In robotically assisted laparoscopic surgery, soft-tissue motion tracking and structure recovery are important for intraoperative surgical guidance, motion compensation and delivering active constraints. In this paper, we present a novel method for feature based motion tracking of deformable soft-tissue surfaces in totally endoscopic coronary artery bypass graft (TECAB) surgery. We combine two feature detectors to recover distinct regions on the epicardial surface for which the sparse 3D surface geometry may be computed using a pre-calibrated stereo laparoscope. The movement of the 3D points is then tracked in the stereo images with stereo-temporal constrains by using an iterative registration algorithm. The practical value of the technique is demonstrated on both a deformable phantom model with tomographically derived surface geometry and in vivo robotic assisted minimally invasive surgery (MIS) image sequences.

Algorithms↗

Patient-specific bronchoscope simulation with pq-space-based 2D/3D registration.

OBJECTIVE: The use of patient-specific models for surgical simulation requires photorealistic rendering of 3D structure and surface properties. For bronchoscope simulation, this requires augmenting virtual bronchoscope views generated from 3D tomographic data with patient-specific bronchoscope videos. To facilitate matching of video images to the geometry extracted from 3D tomographic data, this paper presents a new pq-space-based 2D/3D registration method for camera pose estimation in bronchoscope tracking. METHODS: The proposed technique involves the extraction of surface normals for each pixel of the video images by using a linear local shape-from-shading algorithm derived from the unique camera/lighting constraints of the endoscopes. The resultant pq-vectors are then matched to those of the 3D model by differentiation of the z-buffer. A similarity measure based on angular deviations of the pq-vectors is used to provide a robust 2D/3D registration framework. Localization of tissue deformation is considered by assessing the temporal variation of the pq-vectors between subsequent frames. RESULTS: The accuracy of the proposed method was assessed by using an electromagnetic tracker and a specially constructed airway phantom. Preliminary in vivo validation of the proposed method was performed on a matched patient bronchoscope video sequence and 3D CT data. Comparison to existing intensity-based techniques was also made. CONCLUSION: The proposed method does not involve explicit feature extraction and is relatively immune to illumination changes. The temporal variation of the pq distribution also permits the identification of localized deformation, which offers an effective way of excluding such areas from the registration process.

Algorithms↗