PubMed Health⌕ Search

Biomedical subjects

Fariborz Taghipour

Publications and source records attributed to Fariborz Taghipour.

3 recordsLinked to original sources

Optimizing the rotor design for controlled-shear affinity filtration using computational fluid dynamics.

Controlled shear affinity filtration (CSAF) is a novel integrated processing technology that positions a rotor directly above an affinity membrane chromatography column to permit protein capture and purification directly from cell culture. The conical rotor is intended to provide a uniform and tunable shear stress at the membrane surface that inhibits membrane fouling and cell cake formation by providing a hydrodynamic force away from and a drag force parallel to the membrane surface. Computational fluid dynamics (CFD) simulations are used to show that the rotor in the original CSAF device (Vogel et al., 2002) does not provide uniform shear stress at the membrane surface. This results in the need to operate the system at unnecessarily high rotor speeds to reach a required shear stress of at least 0.17 Pa at every radial position of the membrane surface, compromising the scale-up of the technology. Results from CFD simulations are compared with particle image velocimetry (PIV) experiments and a numerical solution for low Reynolds number conditions to confirm that our CFD model accurately describes the hydrodynamics in the rotor chamber of the CSAF device over a range of rotor velocities, filtrate fluxes, and (both laminar and turbulent) retentate flows. CFD simulations were then carried out in combination with a root-finding method to optimize the shape of the CSAF rotor. The optimized rotor geometry produces a nearly constant shear stress of 0.17 Pa at a rotational velocity of 250 rpm, 60% lower than the original CSAF design. This permits the optimized CSAF device to be scaled up to a maximum rotor diameter 2.5 times larger than is permissible in the original device, thereby providing more than a sixfold increase in volumetric throughput.

Animals↗

UV reactor performance modeling by Eulerian and Lagrangian methods.

A study was performed to investigate the influence of hydrodynamics on the performance of ultraviolet (UV) reactors. Two general UV disinfection models were developed by integrating fluence rate models and inactivation kinetics within a commercial computational fluid dynamics (CFD) software package to predict reactor performances. Both a particle tracking (Lagrangian) random walk model and a volumetric reaction rate based (Eulerian) model were implemented. Simulations were performed for two characteristic annular single-lamp UV reactor configurations, with inlets concentric (L-shape) and normal (U-shape) to the reactor axis. Two fluence rate models, the infinite line source assumption and the finite line or multiple point source summation (MPSS), were used. First-order inactivation kinetics was assumed for disinfection, with rate constants from MS2 bacteriophage assays. The simulation results provided detailed information on the velocity profiles, reaction rates, range of absorbed dose, and areas of short circuiting of the UV reactors. Model predictions based on both the Lagrangian dose distribution and Eulerian concentration distribution were in good agreement with each other at high flow rates but showed some discrepancies at lower flow rates. Experimental verification of the general models was performed by simulating the disinfection performance of an industrial prototype UV reactor. Results from both integration approaches were shown to be in good agreement with the provided biodosimetry data.

Kinetics↗

Ultraviolet and ionizing radiation for microorganism inactivation.

The impacts of UV irradiation, gamma irradiation, and a combination of both on Escherichia coli inactivation in primary and secondary wastewater effluents were investigated. UV doses of 35 and 62 J/m(2) were required for a 1-log inactivation of E. coli in the primary and secondary wastewater samples, respectively. A gamma dose of 170 Gy (J/kg) was required for a 1-log inactivation of E. coli in both wastewater samples. Variation in gamma radiation dose rates did not have a significant impact on the extent of inactivation at a given total dose. Gamma irradiation of previously UV-irradiated samples indicated that particle-associated microorganisms, which are protected from UV, can be inactivated by ionizing radiation at a rate similar to that for free microorganism inactivation. An estimation of the energy required for disinfection indicated that, in general, the required energy and the energy cost for E. coli inactivation using ionizing radiation are considerably higher than those for UV radiation.

Disinfection↗