PubMed Health⌕ Search

Biomedical subjects

Feenix Y Pan

Publications and source records attributed to Feenix Y Pan.

3 recordsLinked to original sources

Efficient testing of segmented aspherical mirrors by use of reference plate and computer-generated holograms. I. Theory and system optimization.

Telescopes with large aspherical primary mirrors collect more light and are therefore sought after by astronomers. Instead of large mirrors as a single piece, they can be made by use of numerous smaller segments. Because the segments must fit together to create the effect of a single mirror, segmented optics present unique challenges to fabrication and testing that are absent for monolithic optics. We have developed a new method for measuring large quantities of segments accurately, quickly, and economically using an interferometric test plate and computer-generated hologram (CGH). In this test, the aspheric mirror segments are interferometrically measured by use of a test plate with a best-fit spherical surface. The aspherical departure is accommodated with a small CGH that is imaged onto the test plates. The radius of curvature is tightly controlled by maintaining the gap between the test plate and the segment. We present a summary of the test and give the basic design tradeoffs for using a single system to measure all of the segments of a large aspheric mirror.

Journal Article↗

Efficient testing of segmented aspherical mirrors by use of a reference plate and computer-generated holograms. II. Case study, error analysis, and experimental validation.

Segmented mirrors present unique challenges to fabrication and testing that are absent for monolithic optics. Since traditional asphere tests do not address segmented optics adequately, we validate a previously developed method to test large quantities of segments accurately, quickly, and economically. In this test, the aspheric shape of each segment is controlled to high accuracy by use of computer-generated holograms, and the radius of curvature is tightly controlled by use of the reference plate. In an adjoining paper [Appl Opt 43, 5303 (2004)] we developed the theory for this test, and now we present a complete system design and optimization for measuring the 1.4-m segments from a 30-m F/1 primary. A complete tolerance analysis predicts a test accuracy of 4.8-nm rms surface and excellent accuracy for controlling the geometry of the segment. In addition, a laboratory demonstration using 30-cm optics is presented that demonstrated 3.9-nm rms surface accuracy.

Journal Article↗

Fabrication and alignment issues for segmented mirror telescopes.

There is a great demand for new telescopes that use larger primary mirrors to collect more light. Because of the difficulty in the fabrication of mirrors larger than 8 m as a single piece, they must be made with numerous smaller segments. The segments must fit together to create the effect of a single mirror, which presents unique challenges for fabrication and testing that are absent for monolithic optics. This is especially true for the case of a highly aspheric mirror required to make a short two-mirror telescope. We develop the relationship between optical performance of the telescope and errors in the manufacture and operation of the individual segments.

Journal Article↗