PubMed Health⌕ Search

Biomedical subjects

Felicity K Sartain

Publications and source records attributed to Felicity K Sartain.

2 recordsLinked to original sources

Holographic lactate sensor.

Measurement of blood l-lactate is used to assess and monitor exercise performance in sports medicine. This report describes the initial development of a holographic sensor, which employs a synthetic receptor, to enable the selective and continuous real-time measurement of l-lactate for eventual in vivo application. Three boronic acid-based receptors have been synthesized, integrated into thin acrylamide hydrogel films, and then subsequently transformed into holographic sensors. Changes in the replay wavelength of the sensors were used to characterize the swelling behavior of the matrix as a function of l-lactate concentration. It was found that the incorporation of 3-acrylamidophenyl boronic acid into an acrylamide hydrogel produced the largest response toward l-lactate. The effects of hydrogel composition, fluctuating l-lactate concentrations, and the response of potential interfering agents to the sensor have been investigated.

Acrylamide↗

Holographic glucose sensors.

A novel holographic sensor system capable of detecting dynamic changes in glucose concentration has been developed. The hologram is recorded within a bio-compatible hydrogel matrix containing phenylboronic acid derivatives. On binding glucose, the colour of the hologram red-shifts to longer wavelengths as the hydrogel expands and this colour change is used to quantify glucose concentration. However, phenylboronic acids are non-selective and bind a wide variety of cis-diols. In blood, glucose is the only sugar found free at high concentration, whilst other sugars are typically found as part of glycoproteins and macromolecular structures. Although glycoproteins have been shown to have no effect on the sensor, phenylboronic acids can bind lactate much more readily than glucose. We have designed two polymer hydrogel systems to increase the selectivity of the sensor for glucose over lactate. The first involved the use of high concentrations of 3-acrylamidophenylboronic acid (3-APB) whilst the second system utilised 2-acrylamido-5-fluorophenylboronic acid (5-F-2-MAPB). Both systems displayed an increased selectivity to glucose over lactate at physiological pH and ionic strength and could be deployed as selective holographic sensors for glucose detection in physiological fluids.

Biosensing Techniques↗