PubMed Health⌕ Search

Biomedical subjects

Felipe A Medeiros

Publications and source records attributed to Felipe A Medeiros.

47 records · Page 3Linked to original sources

Intraocular pressure fluctuations in response to the water-drinking provocative test in patients using latanoprost versus unoprostone.

Impairment of outflow facility in glaucoma causes large intraocular pressure (IOP) fluctuations that have been shown to be a risk factor for disease progression. The water-drinking provocative test (WDT) has been proposed as an indirect measurement of outflow facility to compare intraocular pressure responses of glaucoma eyes to different drugs. This study was a double-masked, randomized, parallel-group clinical trial comparing the IOP fluctuations in response to the WDT in patients using latanoprost versus unoprostone. After completing a wash-out of ocular hypotensive medications, patients with primary openangle glaucoma or ocular hypertension were randomized to receive either latanoprost (N=40) or unoprostone (N=42). IOP was measured before treatment and at 8 weeks after treatment (baseline IOP for WDT), followed by the WDT. IOP fluctuations and maximum IOP after water ingestion were compared between the two groups. Analysis of covariance was used to adjust for the effects of baseline IOP and treatment efficacy. The mean percentage reduction of IOP was 27% in patients using latanoprost, as compared to 13% in patients using unoprostone (p<0.001). Patients on treatment with latanoprost had significantly less IOP fluctuations in response to the WDT, compared to patients using unoprostone. From an overall baseline IOP of 20.0 mmHg and an overall treatment efficacy of 20%, the mean+/-standard error of the mean (SEM) of the IOP fluctuation during the WDT was 5.3+/-0.4 mmHg in the unoprostone group, and 3.6+/-0.4 mmHg in the latanoprost group (p=0.005, ANCOVA). This could represent an additional benefit of latanoprost over unoprostone in controlling the intraocular pressure of glaucomatous patients.

Antihypertensive Agents↗

Confocal scanning laser ophthalmoscopy classifiers and stereophotograph evaluation for prediction of visual field abnormalities in glaucoma-suspect eyes.

PURPOSE: To determine whether Heidelberg Retina Tomograph (HRT; Heidelberg Engineering, Dossenheim, Germany) classification techniques and investigational support vector machine (SVM) analyses can detect optic disc abnormalities in glaucoma-suspect eyes before the development of visual field abnormalities. METHODS: Glaucoma-suspect eyes (n = 226) were classified as converts or nonconverts based on the development of repeatable (either two or three consecutive) standard automated perimetry (SAP)-detected abnormalities over the course of the study (mean follow-up, approximately 4.5 years). Hazard ratios for development of SAP abnormalities were calculated based on baseline classification results, follow-up time, and end point status (convert, nonconvert). Classification techniques applied were HRT classification (HRTC), Moorfields Regression Analysis, forward-selection optimized SVM (SVM fwd) and backward elimination-optimized SVM (SVM back) analysis of HRT data, and stereophotograph assessment. RESULTS: Univariate analyses indicated that all classification techniques were predictors of the development of two repeatable abnormal SAP results, with hazards ratios (95% confidence interval [CI]) ranging from 1.32 (1.00-1.75) for HRTC to 2.0 (1.48-2.76) for stereophotograph assessment (all P < or = 0.05). Only SVM (SVM fwd and SVM back) analysis of HRT data and stereophotograph assessment were univariate predictors of the development of three repeatable abnormal SAP results, with hazard ratios (95% CI) ranging from 1.73 (1.16-2.82) for SVM fwd to 1.82 (1.19-3.12) for SVM back (both P < 0.007). Multivariate analyses including each classification technique individually in a model with age, baseline SAP pattern standard deviation [PSD], and baseline IOP indicated that all classification techniques except HRTC (P = 0.06) were predictors of the development of two repeatable abnormal SAP results with hazards ratios ranging from 1.30 (0.99, 1.73) for HRTC to 1.90 (1.37, 2.69) for stereophotograph assessment. Only SVM (SVM fwd and SVM back) analysis of HRT data and stereophotograph assessment were significant predictors of the development of three repeatable abnormal SAP results in multivariate analyses; hazard ratios of 1.57 (1.03, 2.59) and 1.70 (1.18, 2.51), respectively. SAP PSD was a significant predictor of two repeatable abnormal SAP results in multivariate models with all classification techniques, with hazard ratios ranging from 3.31 (1.39, 7.89) to 4.70 (2.02, 10.93) per 1-dB increase. CONCLUSIONS: HRT classifications techniques and stereophotograph assessment can detect optic disc topography abnormalities in glaucoma-suspect eyes before the development of SAP abnormalities. These data support strongly the importance of optic disc examination for early glaucoma diagnosis.

Adult↗

Corneal thickness measurements and visual function abnormalities in ocular hypertensive patients.

PURPOSE: It has been suggested that a considerable subset of patients currently classified as having ocular hypertension may have thicker than average corneas that result in an overestimation of the true intraocular pressure (IOP). As a consequence, ocular hypertension patients with greater corneal thickness may be at a lower risk for functional damage, such as that detected by short-wavelength automated perimetry (SWAP). The purpose of this study was to evaluate the frequency of SWAP deficits in ocular hypertension patients and to correlate these findings with corneal thickness measurements in the same patients. DESIGN: Cross-sectional observational study. METHODS: Sixty-eight ocular hypertension patients with normal optic disks and 63 normal subjects were included in the study. All participants underwent standard automated perimetry (SAP), SWAP, and central corneal thickness measurements using ultrasound pachymeter. Central corneal thickness measurements in ocular hypertension patients with abnormal visual field test results were compared with central corneal thickness measurements in ocular hypertension patients with normal visual field results. In addition, central corneal thickness measurements in ocular hypertension patients were compared with central corneal thickness measurements in normal subjects. RESULTS: Sixteen of 68 patients with ocular hypertension (24%) demonstrated SWAP abnormalities, whereas four of 68 (6%) showed a deficit on SAP. The mean central corneal thickness in ocular hypertension patients with abnormal SWAP results was significantly lower than the mean central corneal thickness in ocular hypertension patients with normal SWAP results (545 +/- 25 microm vs 572 +/- 35 microm; P =.006). The mean central corneal thickness in the normal group was 557 +/- 33 microm. The mean central corneal thickness in ocular hypertension patients with normal SWAP results was significantly higher than in normal subjects (P =.02). There was no significant difference between mean central corneal thickness in normal subjects and in ocular hypertension patients with abnormal SWAP results (P =.19). CONCLUSIONS: The patients classified as having ocular hypertension but with visual field loss detected by SWAP had significantly lower central corneal thickness measurements than the ocular hypertension patients with normal visual field results. These results suggest that central corneal thickness should be taken into account when assessing risk for the development of glaucomatous damage among ocular hypertension patients.

Aged↗

Axonal loss after traumatic optic neuropathy documented by optical coherence tomography.

PURPOSE: To report longitudinal retinal nerve fiber layer (RNFL) thickness measurements using optical coherence tomography (OCT) in a patient with traumatic optic neuropathy. DESIGN: Observational case report. METHODS: A 14-year-old boy with severe optic nerve trauma had repeated OCT scans of the peripapillary retinal nerve fiber layer at 3 days, 20 days, 40 days, and 70 days after injury. RESULTS: There was gradual loss of nerve fibers as shown by the OCT color-coded map, RNFL thickness profile, and RNFL thickness measurements around the optic disk. At 70 days of follow-up, severe thinning of the RNFL was observable. CONCLUSIONS: These findings suggest that OCT is able to assess and monitor axonal loss after traumatic optic neuropathy.

Adolescent↗

Corneal thickness as a risk factor for visual field loss in patients with preperimetric glaucomatous optic neuropathy.

PURPOSE: To determine whether central corneal thickness (CCT) is a risk factor for visual field loss development among patients diagnosed with preperimetric glaucomatous optic neuropathy (GON). DESIGN: Observational cohort study. METHODS: The study included 98 eyes of 98 patients with GON, with a mean follow-up time of 4.3 +/- 2.7 years. Diagnosis of GON was based on masked assessment of optic disk stereophotographs. All patients had normal standard automated perimetry visual fields at baseline. Criteria for visual field abnormality were derived from a prior study. Several clinical factors (CCT, intraocular pressure, vertical cup-to-disk ratio, refraction, age, gender, family history of glaucoma, high blood pressure, cardiovascular disease, and migraine) were investigated to ascertain whether there is an association with development of repeatable visual field loss. Cox proportional hazards models were used to obtain hazard ratios (HR) and identify factors that predicted which individuals developed glaucomatous visual field loss during the follow-up period. RESULTS: Thirty-four patients (35%) developed repeatable visual field abnormality during follow-up. In multivariate analysis, risk factors that predicted the development of visual field loss were a thinner CCT (adjusted HR = 1.62/40 microm thinner; P =.023; 95% confidence interval [CI]: 1.07-2.45), higher baseline intraocular pressure (adjusted HR = 1.07/mm Hg; P =.022; 95% CI: 1.01-1.14), and larger baseline vertical cup-to-disk ratio (adjusted HR = 1.63/0.1 larger; P =.009; 95% CI: 1.13-2.35). The mean +/- standard deviation CCT of GON patients who developed visual field loss was 543 +/- 36 microm compared with 565 +/- 35 microm of those who did not develop visual field abnormalities (P =.005, Student t test). CONCLUSIONS: Central corneal thickness is a risk factor for development of visual field loss among patients diagnosed with preperimetric GON. It is important to consider CCT when establishing target intraocular pressure of patients with GON.

Cohort Studies↗

Corneal thickness measurements and frequency doubling technology perimetry abnormalities in ocular hypertensive eyes.

OBJECTIVE: It has been suggested that some patients currently diagnosed with ocular hypertension (OHT) may have thicker than average corneas that result in an overestimation of their true intraocular pressure. Consequently, patients with OHT with greater corneal thickness may be at a lower risk for functional glaucomatous damage, including visual field loss measured with frequency doubling technology (FDT) perimetry. The purpose of this study was to evaluate the frequency of FDT perimetry deficits in patients with OHT and to correlate these findings with central corneal thickness (CCT) measurements. DESIGN: Observational case control study. PARTICIPANTS AND CONTROLS: Sixty-five patients with OHT with normal optic discs and normal standard achromatic automated perimetry (SAP) visual fields and 52 normal control subjects. METHODS: All participants underwent SAP, FDT perimetry, and CCT measurements using ultrasound pachymetry. MAIN OUTCOME MEASURES: CCT measurements in patients with OHT with abnormal repeatable FDT test results were compared with CCT measurements in patients with OHT with normal FDT results. In addition, CCT measurements in patients with OHT were compared with CCT measurements in normal control subjects. RESULTS: Fourteen of 65 patients with OHT (21.5%) demonstrated repeatable FDT abnormalities. The mean CCT of patients with OHT with abnormal FDT results was significantly lower than the mean CCT of patients with OHT with normal FDT results (542+/-35 microm versus 575+/-35 microm; P = 0.003). The mean CCT in the normal control group was 556+/-36 microm. The mean CCT in patients with OHT with normal FDT results was significantly higher than in normal subjects (P = 0.008). No statistically significant difference was found between mean CCT in normal subjects and in patients with OHT with abnormal FDT results (P = 0.18). CONCLUSIONS: Patients currently diagnosed with OHT, but with visual field loss detected by FDT perimetry, had significantly lower CCT measurements than patients with OHT with normal FDT results. These findings suggest that patients with OHT with thinner corneas are more likely to develop early glaucomatous functional damage and that CCT measurements should be taken into account when assessing risk for the development of glaucoma among OHT subjects.

Case-Control Studies↗

Fourier analysis of scanning laser polarimetry measurements with variable corneal compensation in glaucoma.

PURPOSE: To apply Fourier analysis to the retinal nerve fiber layer (RNFL) thickness measurements obtained with scanning laser polarimetry (SLP), by using variable corneal compensation, and to evaluate the ability of this method to discriminate glaucomatous from normal eyes. METHODS: The study included one eye each of 55 patients with glaucoma and 52 healthy subjects. RNFL thickness measurements were obtained with a modified commercial scanning laser polarimeter (GDx Nerve Fiber Analyzer; Laser Diagnostic Technologies, Inc., San Diego, CA) so that corneal birefringence could be corrected on a subject-specific variable basis. The shape of the RNFL thickness double-hump pattern was analyzed by Fourier analysis of polarimetry data. Fourier coefficients and GDx parameters were compared between the two groups. A linear discriminant function was developed to identify and combine the most useful Fourier coefficients to separate the two groups. Receiver operating characteristic (ROC) curves were obtained for each measurement, and sensitivity values (at fixed specificities) were calculated. RESULTS: The Fourier-based linear discriminant function (LDF Fourier) resulted in a sensitivity of 84% for a specificity set at 92%. For similar specificity, the GDx software-provided parameters had sensitivities ranging from 24% to 69%. The area under ROC curve for the LDF Fourier was 0.949, significantly larger than the ROC curve area for the single best GDx software-provided parameter, superior average (0.870). CONCLUSIONS: The combination of Fourier RNFL thickness measures in an LDF, obtained using SLP with variable corneal compensation, improved the ability to discriminate glaucomatous from healthy eyes, compared with the GDx software-provided parameters.

Aged↗

Intraocular pressure fluctuations in medical versus surgically treated glaucomatous patients.

The purpose of this study was to compare the IOP fluctuations in the daytime tension curves of glaucoma patients under ocular hypotensive therapy with those of patients previously submitted to trabeculectomy. We also evaluated the IOP peaks and fluctuations for the same patients in response to the water-drinking test (WDT). The study included 30 primary open-angle glaucoma (POAG) patients using ocular hypotensive medications and with no history of previous intraocular surgery (medical group), and 30 POAG patients previously submitted to one or more trabeculectomies though taking no medication at the time of the study (surgical group). All patients were submitted to a diurnal tension curve--DTC (8:30-17:00/3-hour intervals) followed by the WDT. The IOP peak and IOP fluctuation during the diurnal tension curve were significantly greater in the medical group than in the surgical group. The same was observed following the WDT. From an overall baseline IOP of 10.6 mmHg, the mean IOP change following the WDT was 13% in the surgical group and 40% in the medical group. Patients submitted to trabeculectomy have less TOP fluctuations during the diurnal tension curve and following a water-drinking provocative test. This effect could represent an additional benefit of surgery in controlling the intraocular pressure of glaucomatous patients.

Aged↗

Medical backgrounders: glaucoma.

Glaucoma is a leading cause of irreversible blindness in the world. Currently, glaucoma is diagnosed as a progressive optic neuropathy with characteristic optic disc and nerve fiber layer damage, usually associated with loss of visual function. The intraocular pressure (IOP) is the most important risk factor for the disease, although a significant proportion of patients do not have elevated IOP. Other risk factors include older age, African descent, myopia and family history of the disease. The ophthalmoscopic examination of the optic disc is essential to identify the signs of glaucomatous optic neuropathy, such as increased cupping, neuroretinal rim thinning or optic disc hemorrhages. Glaucomatous visual field loss usually starts in the periphery, and loss of central vision does not occur until late in the course of the disease. Visual function is most commonly assessed by standard automated perimetry; however, as many as 50% of nerve fibers can be lost before the appearance of visual field defects in this test. Newer technologies have been developed to find more sensitive ways to detect early glaucoma using both functional (short-wavelength automated perimetry and frequency-doubling perimetry) and structural (scanning laser topography, optical coherence tomography and scanning laser polarimetry) measurements. The management of glaucoma is based on lowering the intraocular pressure to prevent further optic nerve damage. Currently, there are five major classes of medications that are used to lower the intraocular pressure: Beta-adrenergic antagonists, adrenergic agonists, parasympathomimetics, prostaglandin-like analogues and carbonic anhydrase inhibitors. The goal of therapy is to maintain adequate vision for patients during their lifetime, keeping in mind the possible adverse effects of the drugs. If additional lowering of IOP is indicated or if medication fails to sufficiently lower the IOP, laser trabeculoplasty is usually the next step. If IOP is still not adequately controlled, incisional glaucoma surgery is indicated. Neuroprotective agents, which directly protect the optic nerve in glaucoma, are being evaluated in clinical trials.

Glaucoma↗

Short-wavelength automated perimetry can predict glaucomatous standard visual field loss by ten years.

Examination of visual fields using standard achromatic automated perimetry (SAP) is essential for glaucoma management. However, as many as 35-50% of retinal ganglion cells can be lost before a visual field defect is detected. Previous studies have indicated that examination of the short-wavelength (blue) sensitive color system may be able to detect early functional loss in glaucoma. Moreover, it has been reported to detect glaucomatous visual field loss as many as 5 years earlier than SAP. We describe the case of a patient who demonstrated visual field defects on short-wavelength automated perimetry (SWAP) ten years prior to developing visual field defects in SAP.

Female↗