PubMed Health⌕ Search

Biomedical subjects

Feng Fu

Publications and source records attributed to Feng Fu.

12 recordsLinked to original sources

Pseudo-polar drive patterns for brain electrical impedance tomography.

Brain electrical impedance tomography (EIT) is a difficult task as brain tissues are enclosed by the skull of high resistance and cerebrospinal fluid (CSF) of low resistance, which makes internal resistivity information more difficult to extract. In order to seek a single source drive pattern that is more suitable for brain EIT, we built a more realistic experimental setting that simulates a head with the resistivity of the scalp, skull, CSF and brain, and compared the performance of adjacent, cross, polar and pseudo-polar drive patterns in terms of the boundary voltage dynamic range, independent measurement number, total boundary voltage changes and anti-noise performance based on it. The results demonstrate that the pseudo-polar drive pattern is optimal in all the aspects except for the dynamic range. The polar and cross drive patterns come next, and the adjacent drive pattern is the worst. Therefore, the pseudo-polar drive pattern should be chosen for brain EIT.

Brain↗

[A simulation study of electrical impedance scan-imaging based on a phantom].

OBJECTIVE: To testify the feasibility of electrical impedance scanning (EIS) imaging and to classify the factors influencing EIS imaging at the early stage of electrical impedance scanning breast imaging study. METHOD: Based on the EIS experiment workplace, a phantom to simulate the distribution of breast tissue was designed. Using NaCl solution and agar block with different conductance, three kinds of electric fields disturbances were simulated. RESULT: Different electric fields disturbance induced by different conductance distributions bring different imaging effects. CONCLUSION: The imaging based on the theory of EIS is feasible. Initiative factors influencing EIS imaging are confirmed.

Agar↗

[A method of building the finite-element model with the contour line of human brain].

The contour line of human brain was simulated by the curve-fitting methods and then the inner area was discretized by advancing-front methods which was improved at last. The curve-fitting result was similar to the CT picture of the human brain and the discrete result of inner area could be completed quickly by improved advanced-front methods. A finite element model with the contour line of human brain was built primarily which will contribute to the next algorithm study of electrical impedance tomography in human brain.

Algorithms↗

[A data acquisition system for induced current electrical impedance tomography].

Induced current electrical impedance tomography (ICEIT) is a new branch of electrical impedance tomography (EIT). We have designed and set up a high accuracy ICEIT hardware system with 32 electrodes based on physical phantom, and we have brought forward a new method to reduce the additive electromotive force (EMF) in circuit of the electrode leads. By use of the technique of twisted pair wire, the additive EMF in the circuit of the electrode leads has been reduced to 10% of that before use and the precision of the system has been improved. The precision of the final results is better than 0.5% after 1000 measurement data averaged. Applying the reconstructive algorithm, we have obtained preliminary images based on physical phantom.

Algorithms↗

[A bipolar optocoupler isolation amplifier with high precision and wide bandwidth].

To fit the technological requirements in electrical impedance tomography system, an improved bipolar optocoupler isolation amplifier based on single analog optocoupler was realized. The experimental results illustrates that the full power -3dB bandwidth of this circuit is greater than 800 KHz, the equivalent output noise is lower than 50 uV(RMS), and the linearity at +/- 4 V inputs is lower than 0.01%. In addition to these features, the circuit also have the advantages of simple structure and no distortion caused by mismatch between analog optocouplers.

Amplifiers, Electronic↗

[Frequency characteristic of diseased breast tissues detected by electrical impedance scanning].

The rules of conductance parameters on diseased breast tissue, which change with the driven frequency, are studied by use of electrical impedance scanning. This work is intended to provide a basis for further examination of breast. We have obtained conductance parameters' frequency characteristic of three kinds of breast diseases, i.e. invasive ductal carcinoma, neoplastic hyperplasia, and mastopathia. And by comparison, we find that the frequency characteristic of the diseased breast tissues is different from that of the peripheral normal tissues, and the frequency characteristic shows differences among the three kinds of diseased breast tissues. So, we are able to identify the kind of breast disease by its frequency characteristic.

Breast Diseases↗

[An experimental system of induced-current EIT].

Induced-current electrical impedance tomography (ICEIT) is a newly hot research field in electrical impedance tomography (EIT) because of its advantages of contactless exciting. A preliminary ICEIT system with 3 excitation coils has been accomplished. It includes the constant current source (CCS), power amplifiers, excitation coils,physical phantom, measurement-mode setting circuit, signal measuring block, DAC and digital I/O card. The CCS is accomplished with Direct Digital Synthesis (DDS) technique. Its frequency is 46.875 KHz. Its output current is divided into 16 steps from 0.16 mA to 2.56 mA which can be set by computer. The three driving coils have the same diameter of 50 cm, each coil's inductance is 193.5 microH. The power amplifier can provide 800 mA driving current (f = 46.875 KHz) to the coil under +/- 25 V power supplying. The signal from measurement electrodes is switched to measurement channel which includes IA, BP filter and synchronized demodulator, then the analog signal is converted to digital signal by a 12b A/D Card and the data is acquired by DMA mode. Our experiments show that a distinguish change of signal from the surface electrodes can be acquired by the experimental system when different objects are placed in the physical phantom. And 3 x 31 signals for preliminary imaging have been acquired.

Algorithms↗

[The measurement frequency distribution in tissue impedance spectroscopy measurement].

In the research of tissue impedance spectroscopy measurement, the authors constructed a frequency sets that produce angularly equidistant points on the Nyquist loci. The studies of simulation data model demonstrate that, by use of the same quantity of frequency points and in comparison with the frequency sets that are logarithmic and quasi-linear, the angularly equidistant frequency sets can improve the estimate accuracy of tissue electrical model parameters of alpha and fc.

Biomedical Engineering↗

[In vivo measurement of rabbits brain impedance frequency response and the elementary imaging of EIT].

The in vivo measurements of rabbit brain tissue impedance were taken under both normal and ischemic conditions by using two-electrode measurement method in the frequency range from 0.1 Hz to 1 MHz. The dynamic images about the resistivity of cerebral ischemia were reconstructed based on a 16-electrode system. The results of in vivo measurement showed that the ratio of impedance increased can be as high as 75% at frequencies lower than 10 Hz. In the range from 1 KHz to 1 MHz, the ratio showed a constant value of 15%. The electrical impedance tomography (EIT) images obtained suggested that the regions of impedance changes highly correspond to the position of ischemia. It is confirmed that the brain function changes caused by local deficiency of blood can be detected and imaged by EIT method.

Animals↗

[The complex impedance frequency response and the equivalent circuit model of human brain].

The complex impedance measurements of human brain tissue in vitro are made by using four-electrode measurement methods in the frequency range from 0.1 Hz to 1 MHz. The Solartron 1255 B frequency response analyzer is used. The frequency response curves of the imaginary part of human brain's complex impedance do not appear as a single peak curve which other bio-tissues show, and the Cole-Cole diagram of human brain is different from the others as well. The construction of the equivalent circuit model obtained is more complex. However, these characteristics of human brain are all the same as rabbit brain's. The equivalent circuit model obtained will be helpful to constructing the equivalent circuit model of human head in the EIT researches.

Adult↗

[Simulation study of the reconstruction algorithm for electrical impedance tomography based on the sensitivity theorem].

It is the intent of this paper to develop better reconstruction algorithm for electrical impedance tomography (EIT). Simulation study of the reconstruction algorithm based on the sensitivity theorem is made and the reconstruction algorithm is compared with other normal algorithms. The results indicate that sensitivity method as a kind of static reconstruction algorithm has higher accuracy and speed of iteration, so it is worth researching for laboratory modality work.

Algorithms↗

[The impedance frequency response of the human skull].

The human skull impedance was quantitatively measured by means of Frequency Response Analyzer and its software. The impedance-frequency response curves of human skull were obtained. By analyzing the curves, we found that the characteristic frequency of human skull should be around 10 KHz.

Adult↗