PubMed Health⌕ Search

Biomedical subjects

Fernando E Boada

Publications and source records attributed to Fernando E Boada.

6 recordsLinked to original sources

Small tip angle three-dimensional tailored radiofrequency slab-select pulse for reduced B1 inhomogeneity at 3 T.

This work presents a small tip-angle 3D tailored RF slab-select pulse for reducing the B1 field inhomogeneity at 3T. The compensated slice profile was determined from a B1 inhomogeneity map. SNR improvement and degree of artifact reduction were evaluated in a NiCl2 doped phantom and human brains. The technique was found to reduce inhomogeneities as large as 30% of the peak image magnitude in all three spatial directions in the brain using a standard head coil.

Algorithms↗

Algebraic description of spin 3/2 dynamics in NMR experiments.

The dynamics of spin 3/2 systems is analyzed using the density matrix theory of relaxation. By using the superoperator formalism, an algebraic formulation of the density matrix's evolution is obtained, in which the contributions from free relaxation and RF application are easily factored out. As an intermediate step, an exact form for the propagator of the density matrix for a spin 3/2 system, in the presence of static quadrupolar coupling, inhomogeneous static magnetic field, and relaxation is demonstrated. Using this algebraic formulation, exact expressions for the behavior of the density matrix in the classical one-, two-, and three-pulse experiments are derived. These theoretical formulas are then used to illustrate the bias introduced on the measured relaxation parameters by the presence of large spatial variations in the B0 and B1 fields. The theoretical predictions are easily evaluated through simple matrix algebra and the results agree very well with the experimental observations. This approach could prove useful for the characterization of the spatial variations of the signal intensity in multiple quantum-filtered sodium MRI experiments.

Magnetic Resonance Spectroscopy↗

Triple-quantum-filtered imaging of sodium in presence of B(0) inhomogeneities.

Triple quantum filtered sodium MRI techniques have been recently demonstrated in vivo. These techniques have been previously advocated as a means to separate the sodium NMR signal from different physiological compartments based on the differences between their relaxation rates. Among the different triple quantum coherence transfer filters, the three-pulse coherence transfer filter has been demonstrated to be better suited for human imaging than the traditional four-pulse implementation. While the three-pulse structure has distinct advantages in terms of RF efficiency, the lack of a refocusing pulse in the filter introduces an increased dependence on the main magnetic field inhomogeneities, which can sometimes lead to significant signal loss. In this paper, we characterize these dependencies and introduce a method for their compensation through the acquisition of a B(0) map and the use of a modified phase cycling scheme.

Artifacts↗

Variable-density spiral 3D tailored RF pulses.

A variable-density spiral method is presented for reducing three-dimensional tailored radiofrequency pulse duration. Pulse length reductions of 21-32% are possible, with only a small error in the desired excitation profile. The method is demonstrated using simulations, phantom experiments, and T(2)*-weighted images of brain regions with susceptibility-induced intravoxel dephasing. Four 19.7-ms shots were needed to excite a 5-mm-thick slice with reduced susceptibility artifacts in the sinus region at 3T.

Artifacts↗

Detection of sodium ions in anisotropic environments through spin-lock NMR.

A new method for selectively detecting sodium ions in anisotropic environments is presented. A spin-lock (SL) sequence, followed by a coherence transfer pulse, generates rank-two zero-quantum coherences, and converts them into observable transverse magnetization. The quadrupolar polarization is only generated when there are residual quadrupolar couplings in the sample, and provided the SL field strength is comparable to these couplings. This filter has proved to be more efficient than a double-quantum magic-angle (DQ-MA) filter in generating observable signal from ions in anisotropic media in both a nasal bovine cartilage sample and a liquid crystalline DNA sample. Finally, the SL filtering technique does not rely on a flip angle effect for the selection of the desired signal component, as does a DQ-MA filter, and may therefore prove desirable in an imaging experiment, due to its better tolerance to phase and flip angle imperfections.

Animals↗

Multishot 3D slice-select tailored RF pulses for MRI.

A multishot 3D slice-select tailored RF pulse method is presented for the excitation of slice profiles with arbitrary resolution. This method is derived from the linearity of the small tip angle approximation, allowing for the decomposition of small tip angle tailored RF pulses into separate excitations. The final image is created by complex summation of the images acquired from the individual excitations. This technique overcomes the limitation of requiring a long pulse to excite thin slices with adequate resolution. This has implications in applications including T*(2)-weighted functional MRI in brain regions corrupted by intravoxel dephasing artifacts due to susceptibility variations. Simulations, phantom experiments, and human brain images are presented. It is demonstrated that at most four shots of 40 ms pulse length are needed to excite a 5 mm-thick slice in the brain with reduced susceptibility artifacts at 3T.

Brain↗